Document 2JnR5Bd04YdYweB5vZwdRrbqR
-----No. 7 IDEAL ARCOFLAME HEATING UNIT
AUTOMATIC OIL HEAT-YEAR-'ROUND HOT WATER
In a single compact unit, the Arcoflame Heating Unit No. 7 provides, at budget cost, all the advantages of oil heating, plus year-'round domestic hot water if desired. Both the boiler and burner are scientifically designed to burn oil at its highest efficiency, thus assuring perfect team-work in providing maximum heat with least fuel consumption.
When specified, the Arcoflame Heating Unit includes a Bilt-inTACO Hearer, which, in conjunction wjrh the Taco-Abbott System, supplies domestic hot water both winter and summer.
IDEAL HEAT LIB-O-RATOR A factory molded combustion chamber av ailable at slight extra cost. Eliminates need for ordinary fire-brick and saves time and labor. Designed especially for No. 7 and No. 11 Ideal Arcoflame Heating Units. The Heat Lib-O-Rator literally wrings all the heat from combustion and directs it to the heating surfaces of the boiler where it does the most good. It assures more economical heat--less waste up the chimney. It pays to use the Heat Lib-O-Rator on all installations.
RATINGS AND DATA
Mudel N Boiler
. Burner
Transmssion Rate 4.250 BTU/Sq. Ft.
Installed Radiation
Mini mum Burner
Capacitj
Lbs.
Ftcam Water Oil/ hr.
Heat ing Surface Sq. Ft.
Firebox Dimensions
Width Inches
At Grate Line
9" Above Grate Line
Height,
Inches Floor to Crown Sheet of Boiler
Chimney
Lgth. Inches
Sire Height Inches Feet
S or W-715-OB CF-7 320 515 8.0 26.3
IS
IS
3-'l4
Hji 8x8
30
Sor W-719-OB CF-r 3S0 610 9.5 31.5
IS
IS
32 M
ISA 6x8
30
S or W-723-OB CF-7
440 705 10.5
35.7
18
18
32^
2111 8x8
30
S or ^ -727-OB CF-7
500 800 12.0
40.9
18
18
32 X
2SA 8x12 30
Sor W-731 -OB CF-7
5C0 895 13.5
45.1
IS
18
32
23 H 8x12 30
Sor W-735-OB CF-7
620 990 14.5
50.3
18
18
32H
32A 8x12 35
Sor W-739-OB CF-7
GS0 1.085 16.0
54.5
19
18
32l-
35H 8x12 35
t Based on oil of 39,-00 B.t.u./lb.
* Installed radiation capacities are braed on net installed radiation and on tbe presence of a quantity of net installed radiation suffitient for tbe requirements of the building. Nothing need be added for norma! piping and pick-up.
When Bi!t-in Taco Heater is installed, add one square foot per gallon of tank capacity to installed radiation on steam boilers and two square feet per gallon of tank capacity on water boilers before selecting boiler size.
^MERICAN
A 62
September l, 1959
No. 11 IDEAL ARCOFLAME HEATING UNIT--
AUTOMATIC OIL HE AT-VEAR-'ROUND HOT WATER
Bilt-m Taco Heater for summer and winter hoc water supply, with I acoAbbott S>stem, when specified.
Specaily dcsicned finned surfaces collect extra heat from hot gases
Arcoilamc Oil Burner concealed inside jacket.
Jacket finished in Arco green baked enamel
Heat y, indestructible, corrugated air ceil asbestos insulation prevents heat waste.
Machmc-cround section contacts prevent short-circuiting of gases, infiltration of air. and escape of odors.
Flame scientifically proportioned to com bustion chamber t^r maximum economy and iguick heating
Front panel of modem design wi eh chromium stripes. Easily removable for access to boiler.
Pyrex sight glass.
Chromium handles for convenience in removing front jacket panel.
Combination pressure and vacuum gauge on .team boilers; altitude gauge and thermometer on hot w a ter boilers, combined with name plate and framed in chromium.
Especially large steam releasing area and steam dome insure dry steam at entrance to piping
Especially large connections (7-inch nipple) between boiler sections insure rapid circulation <>l boiler water, eliminate clumsy outside mani fold piping for domestic hot water
-RATINGS AND DATA
Model No
Transmission Rate [ 4.500 BTU/Sq Ft.
Boiler
Burner
Radiation
mum
Sq. Ft. EDR
Burner Capacity
Steam Water Oil/fc'r.
Heat- ,
mg Surface Sq. Ft.
Firebox Dimensions
Width. Inches j Height,
At Grate Line
9" Above Grate Line
Inches
Floor to Crown Sheet of Boiler
Chimney
Lgth. Inches Site Height
Inches Feet
S or W-rmi-B CF-U2 355 570 8.5 27.3
IS
IS
32j*
14U S*8
JO
S or W-0511-B CF-112 435 695 10.3
33.4
IS
IS
32 M
IS* 8a8
30
S or W'-Ooll-B CF-112 515 825 12.1
39.6
18
IS
32 K
21H 8x8
30
S or W-07I1-B CF-112 595 950 13.5
45 7
18
18
32!*
25* 8x12 35
S or W-0511-B CF-112 675 1.080 14.9
51.S
IS
IS
32 U
23 if 8x12 35
S or W-0911-R CF-112 755 1,205 16.3
58 0
15
IS
32M
32* 8x12 35
Based on oil of 19,700 B.t.u./Ib
f Capacities are based on net installed radiation and on the presence of a quantity of net installed radiation sufficient for the requirements of the building. Nothing need be added for normal piping and pick-up.
W"hen Bilt-in Taco Heater is i nstalled, add one square foot pj gallon of tank capacity to installed radiation on rteam boilers and two souare feet per gallon of tank capacity on water boilers before selecting boiler sire. When Bilt-in Tankless Taco Heater is installed, add fifty square feet steam radiation per bathroom or eighty square feet water radiation per bathroom to installed radiation before selecting boiler sire.
September /, i9S$
A 63
American
/iLmnii iiuimiii
14034
14036
OIL BURNERS OIL HEATING UNITS
14037