Stranded Copper Fire-Retardant Tape* FIREWALL' HI POWER CABLE IUL) TVPE TC Crost-Unked Polyethylene Neoprene Sheath FIREWALL III MULTICONDUCTOR JACKETED, N.E.C. Type TC 600 Volts, Max- Operating Temp. 90 C. CONSTRUCTION: Conductors are stranded tinned copper insulated with flame-retardant cross-linked polyethylene, circuit coded, conductors cabled with fillers as necessary. Cabled conductors are wrapped with fire retardant tape and jacketed with heavy duty, flame-retardant neoprene sheath. APPLICATION: Recommended for power circuits where fire and radiation resistant properties are re quired. Suitable for general use at 90C and recom mended for industrial and utility installations in con duit, tray, duct or direct burial. UL listed as Type TC cable meeting requirements of Article 340 of N.E.C ADVANTAGES: Have excellent electrical and mechan ical properties. They are lightweight, small diameter cable and are operative after radiation exposure m excess of 2 x 10* Rads, followed by post-accident en vironmental conditions. Cable meets IEEE 383-74 in addition to singles meeting UL and IPCEA Vertical Flame Test requirements. Cables will not propagate flame during a cable tray fire and will also maintain electrical integrity long enough to satisfy posi-acoideut safety requirements. No. of Conductors 3 ** 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 Size AW6 or MCM Stranding 8 7/.0486 6 7/.0612 4 7/.0772 2 7/.0974 1 19/.0664 1/0 19/.0745 2/0 19/.0837 3/0 19/.0940 4/0 19/.1055 250 37/.0822 350 37/.0973 500 37/.1162 Insulation Thickness (mils) 45 45 45 45 45 45 45 45 55 55 55 55 55 55 55 55 55 55 65 65 65 65 65 65 Jacket Thickness (mils) 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80 80 80 110 110 no no no no no Nominal O.D. (in.) .68 .76 .76 .89 .91 1.00 1.04 1.15 1.17 1.30 1.26 1.40 1.36 1.50 1.47 1.63 1.59 1.83 1.80 1.99 2.03 2-25 2.31 2.57 Net Weight (lbs./M') 330 450 490 650 730 920 1050 1320 1330 1680 1460 1820 1830 2340 2150 2850 2750 3500 3360 4300 4440 5580 6100 7610 Ampacity* 50 40 70 56 90 72 120 96 140 112 155 124 185 148 210 168 235 188 270 216 325 260 405 324 . "Rating based on one cable in conduit, duct, direct burial or air, 30 C.ambient, 90 C. conductortemperatures. Copyright tJ78 Dy Th Mirmon Croup. In*. RBB 02816 Polyethylene FIREWALL III Triplexed 600 Volts, Max. Operating Temp. 90 C. CONSTRUCTION: Conductors are stranded tinned copper insulated with flame-retardant cross-linked poly ethylene, then jacketed with a heavy duty flame retard ant, impervious chlorosuffonated polyethylene sheath proper''/ '''Jvaoized and firmly bonded to the insulation Conductors are pre-assembiea at tne tauiuiy miu triplexed cables for ease of installation. APPLICATION: Recommended for power circuits where fire and radiation resistant properties are re quired. Suitable for general use at 90C and recom mended for industrial and utility installation in conduit, . Size AWG or MCM Stranding 8 7/.0486 6 7/.0612 4 7/.0772 2 7/.0974 1 19/.0664 1/0 19/0745 2/0 19/.0837 3/0 19/.0940 4/0 19/.1055 250 37/.0822 300 37/.0900 350 37/.0973 400 37/.1040 500 37/1162 600 61/.0992 750 61/.1109 Diameter (in.) insulation Thickness (mils) .146 45 .184 45 .232 45 .292 45 .332 55 .373 55 .419 55 .470 55 .528 55 .575 65 .630 65 .681 65 .728 65 .813 65 .893 80 .998 80 "Cable m air. 40 C ambient. 90 C conductor temperature. tray, duct or direct burial. Sizes 250-750 MCM approved by N.E.C. Article 318 for use in cable trays. ADVANTAGES: Have excellent electrical and mechanical properties. They are lightweight, small diameter cab'es. ar.d a><i operative after radiation exposu*? *n / 10 Rads, followed by post-accident environmental condi tions. Cable meets IEEE 383-74 in addition to Singles meeting UL and IPCEA Vertical Flame Test requirements. Cables will not propagate flame during a cable tray fire and will also maintain electrical integrity long enough to satisfy post-accident safety requirements. Covering (mils) 15 30 30 30 45 45 45 45 45 65 65 65 65 65 65 65 Overall Diameter (in.) Net Weight <lbs./M') .61 240 .74 443 .85 546 .98 810 1.17 1080 1.26 . 1300 1.36 1590 1.47 1950 1.59 2390 1.83 2940 1.95 3450 2.06 2.16 2.34 3970 4490 5480 2.58 2.81 6560 8070 Ampacity* 66 89 117 158 185 214 247 287 335 374 420 464 500 580 650 747 Printed in U.S.A THE ROCKBESTOS COMPANY New Haven, Connecticut 06504 USA of Tht Mirmon Group RBB 02817