Document 2Jjx7agVoeMYa4DLxzR81ojXg

kI INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION technical center dq EIC1X B3bl. SOUTH CHARLESTON WV CS3Q3 To rrsiril r*.J C"vi3*0* ' Lra soon Area H. E. Rucker 2009 512 Qiov i.o B. H. Avashia, M.D. - 23 J. W. Barna - 2009/6 W. L. Browning - 2009 C. P. Maxwell - 701/2 B. R. McMakin - 2009 F. R. Sunderland - 2009 O' ij.< at'i'g l>pt Ai e.* E-L.tecr January 7, 1987 EM&TS - HS&EA Industrial Hygiene Asbestos Exposure Monitoring Attached are the results of the exposure monitoring performed on seven insulators and one laborer while stripping Asbestos from a two-inch pipe. The pipe was located in a pipe rack across the road from the #1 powerhouse inside the Institute plant. All employees were equipped with either an A0R57A or Willson R12 half-face HEPA cartridge respirator. They were also equipped with 2 pair of coveralls, boots, headsock and gloves. Each employee indicated that they were wearing no street clothes under the coveralls, and that each showered or would shower before leaving the work place. The OSHA established Permissible Exposure Level of 0.2 fibers/cc, for an 8-hour workday (TWAg), was not exceeded. However, the Action Level of 0.1 fiber/cc, also established by OSHA, was exceeded on 2 samples. The Area samples indicate no problem with airborne fibers getting outside of the barricaded area. We continue to urge strict adherence to the proper removal procedures and very careful handling, in order to keep the exposure potential at a minimum. Please inform al1 employees of their exposure monitoring results as soon as possible. Please have each sign and date this report and return to M. A. Patel at Building 701-330. If you have any questions or if we can be of further assistance, please feel free to call us on extension 4779 or 3750. WORK BY: APPROVED BY: Vance E. Stover Attachment VES:MAP:rab 1993P P IcA.Xl. /] (ZiJ Manhar A. Patel UCC 024793 ASBESTOS EXPOSURE MDNITCRINS Ccnp. Ref. W2104 Date 12-16-86 Sanple Type/ Eirplqyee Name Personal/ W. S. Tharpson Sanpling Time 4hrs 24min 12-16-86 Personal/ S. R. Erskine 4hrs 23brin 12-16-86 Personal/ C. 8. Clendenin Air Core. Fibers/cc 0.052 0.037 TV% Fibers/cc Job Classi fication Insulator * Insulator * Insulator 12-16-86 Personal/ T. K. Miller - - * Insulator 12-16-86 Personal/ 4hrs Mn 0.0164 k Laborer R. A. Edwards 12-16-86 Area 4hrs lAmin ^0.0025 12-16-86 Area 4hrs lQmn -4 0.0037 - - OOWENTS Collected while removing approx. 4 feet of Asbestos using BWE 5000. Collected while removing approx. 4 feet of Asbestos using BWE 5000. Voided - could not find respirator to fit - did not work on this job on this day. Voided - Punp fell into trench containing water. Collected while cleaning dropped Asbestos, retrieving bags, etc. Collected downwind approx. 15-20 feet frem the barricade tape - West end. Collected approx. 15-20 feet from the East barrier - downwind. *A TWQg was not calculated because it\ras not known if they had Asbestos exposure before this monitoring period. AS8EST0S Permissible Exposure Level TWg Action Level 0.2 fibers/oc OSHA DTI fiber/oc UCC 024794 AS8EST0S EXPOSURE M3NI7CRIN3 Date Sanple Type/ Enployee Name 12-18-86* Area Sarrpling Time Air Cone. Fibers/cc 6hrs 31nrin 40.0038 TWAq Fibers/cc - Job Classi fication - 12-18-86 Area 6hrs 23tain C0.0038 - 12-18-86 Personal/ T. K. Miller 6hrs 18mn 0.078 12-18-86 12-18-86 Personal/ J. R. Meminger Personal/ R. A. Edvards 6hrs 48rrin 6hrs 44min 12-18-86 Personal/ D. R. Sarrples 6hrs 3&rrin 0.040 0.056 0.047 *Water was used as wetting agent for entire day. 0.061 0.034 0.017 0.038 Insulator Insulator Laborer Insulator COMMENTS Collected on south side of barricade near roadway wind swirling. Collected on north side of barricade near tank - wind swirling. Collected while stripping approx. 125-150 feet of Asbestos from a 2 inch line. Sane as previous sanple. Cleaned and bagged Asbestos dropped to ground level under piperack. Collected while stripping approx 150 feet of Asbestos. ASBESTOS Permissible Exposure Level TWAq v Action Level 0.2 fibers/oc OSHA 0.1 fiber/cc UCC 024795 ASBESTOS EXPOSURE MONITORING Ccrrp. Ref. W2107 Date 12-17-86* Sanple Type/ Employee Mane Area Sarrpling Title Air Cone. Fibers/cc 6hrs 55rrrin <0.0028 TWAq Fibers/cc - Job Classi fication - 12-17-86 Area 6hrs 58mn 0.013 12-17-86 Personal/ W. 5. Thorrpson 6hrs 39min 0.166 0.138 Insulator 12-17-86 12-17-86 Personal/ C. B. Clendenin Personal/ R. A. Edwards 6hrs 48nin 6hrs 3Cmin 0.0664 0.0328 0.0564 0.027 12-17-86 Personal/ M. S. Farmer 6hrs 29nin 0.171 0.139 * BWE 5000 was used as vetting agent for entire day. \ ASBESTOS Permissible Exposure level Action Level 0.2 fibers/cc OSHA 0.1 fiber/cc Insulator Laborer Insulator COMENTS Collected just downwind of the East barrier approx 1015 feet from pipe rack. Collected downwind near the west barrier* - but outside - pujp was located on top of fire hose cabinet. Collected while stripping approx. 125-150 feet of Asbestos from a 2 inch line using Bl 5000 as wetting agent. Same as previous carment. Cleaned up and bagged Asbestos that dropped to the ground. Cleaned up and bagged Asbestos that dropped to the ground. 1993P rab UCC 024796