Document 2JRJGeYd0d0m6agOaQmzaQjXR

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY * pCB Inspection, Monsanto Krumnrich Plant, subject: Sauget, Illinois. DATE: March 9, 1976 FROM: TO: Chief, Air Surveillance Branch, Surveillance and Analysis Division Karl Bremer, Member, Lake Michigan Toxic Substances Committee I A preliminary survey was made of the above Installation to identify (and sample point sources of potential PCB emissions to the atmosphere. :The sampling and analysis were carried out at this source to furnish information to arrive at a further decision that may require an intensive (testing program to quantify the PCB emissions. The sample analysis (revealed the following: . SAMPLING LOCATION NO. OP SAMPLES PCB CONCENTRATION uq/l|3 Steam Ejector - Ground Level, Site #1 2 * 3A - 27.5 3B - 33.9 Steam Ejector - Top Level, Site #2 2 3A - N.A. 3B - N.A. Calculated Storage Tank Emissions Virgin Product . Product Loading and Waste Storage -697.A Kg/year 0.02 Kg/year Monsanto has performed a stack test at the Sauget location quantifying ; the PCB emissions to the atmosphere. Stack-sampling and other reports ' describing process and sampling methodology used at this site are attached. * 3A - Right Side of sampling train - 3B - Left Side tr* ma-< dw.. i-mi HONS 054012 UNITED STATES ENVIRONMENTAL PROTECTION AGENCY SUBJECT: Emissions of PCS from the Incinerator at Monsanto - DATE: February 11,1976 Sauget, Illinois. FROM: R. Edwin Zylstra, Technical Advisor, Special Projects Section TO: Chief, Air Surveillance Branch On January 27-28, 1976 sampling was conducted at the Krummrich Plant of Monsanto in Sauget, Illinois to determine emissions to the air. The samples were taken near the exits of the steam jet ejectors of the non-fractionating distillation process. The exits of the fractionating distillation steam ejector were not sampled because of inaccessibility. The incinerator used to destroy waste PCB's was not sampled because Monsanto had tested the stack and the results were made available to us. 11 have reviewed the test procedures and the data from three stack tests and I feel that the test results accurately indicate the quantity of PCB being emitted into the atmosphere from the incinerator. The Monsanto procedure for stack testing the Incinerator for PCB and particulate is shown in Appendix A. The method is a modified EPA Method 5. The front half is identical to Method S and consists of a sample nozzle, a heated probe, and a heated glassfiber filter. The back half Is as follows: 1. F.lrst impinger empty; 2. Second impinger with 150 ml. of N, N-dimethyl formamide; 3. Third impinger with 75 ml. HaOH solution and 75 ml. Ua2S03 solution; 4. Fourth impinger with 200 g silica gel. Sampling is performed the same as Method 5. To determine the PCB emissions the sample is handled as follow: T. Probe, nozzle and filter are rinsed with hexane. The rinse Is mixed with any condensate from the first impinger and then analyzed for PCB by means of electron capture gas chromotograph. Z. The NN dimethy formamide in the second Impinger is analyzed for PCB by means of electron capture gas chromotograph. The table shows the results of stack tests for PCB on the Incinerator performed by Monsanto. Emission ranged from .00001 to .000248 lbs/hr. Computer printouts of data collected and the results of the last threa tests performed were supplied to us for evaluation. The calculations were checked and no errors were found. Monsanto'-s and our computer printouts are in Appendix B . <n (nunm-Dio-i... (>]) HONS 054013 STACK TESTS 0*J iJOHSAIlTO PCR IHCIKEKATOn Tho following tests were r^de using * modification of Illinois EPA Method 5 and both flow and concsncrations were determined. Data PCB cone" in nq/m* Flow M^/mln. / h/k 7/25/73 3/7/73 8/16/73 8/24/73 10/26/73 11/7/73 11/20/7 3 11/28/73 8/23/74 9/12/74 5/23/75 10/1/75 0.0063 0.0167 0.0176 0.0166 0.0077 0.0056 0.0119 0.0013 0.0149 0.0289 0.0300 0.0181 63.5 94.8 .06.5 .06.8 48.3 58.1 63.8 66.7 71.1 51.1 44.5 92.2 . .S-Jv 2. ? X Z-Vt K, J,JY< .49/ f 4 / 4 -.7/ 4 /.'// /. U<* Z.lXf MOWS 054014 APPENDIX A MONSANTO PROCEDURE FOR STACK TESTING TOR PCBs HONS 054015 5/3 INCINERATOR STACK TEST FOR PC"'S ANT) PARTICULATES SCOPE: This procedure determines the eraount of PCB's and particu lates present in the incinerator stack ga3. ' EQUIPMENT: 1. R.A.C, portable stac'.c gas sampler a. sample box b. unbliical cord 25 feet (2 each) c. -nozzles 0.250 or 0.575 d. clamps (10 each) 23/15 Fisher 5-635? e. 3' combination probe and pitot tube (glass) f. glass connectors (4 each) S. 500 ml Greenburg-Smith impinger each) Fisher Scientific Company, St. Louis, MO cat. no. 9-257, or equivalent. The fourth impinger is modified by replacing the standard tip with a 1/2 Inch ID glass tube extending to one-half Inch from bottom of impinger flask. 2.. Glass orifice to regulate air flow'through pitot tube. (2each) Can be made from broken thermometer. 3. Thermometer 0-220F 4. Thermocouple and potentiometer 3, Nomograph 6. Clip board 7. Air Pump (Dyna pump) 8. Stopwatch (2 each) 9. Tape ruler 10. 3 way plug 11. Stopcock grease 12. 50 ft. of 5/8" rope. 13) . Adjustable wrenches ( 2 each) FOR PARTICULATE TEST ADD: 1. Cyclone and Erlcnmcyer flask 2. Clamps 2 each 23/15 HONS 054016 5H jr Clas3 fiber filter holder l. Class fiber size 7.0 Ci< (Fisher cat. no. 9-07JF) Dry in oven and leave in desioiator. MONS 054017 REAGENTS: a. Sodium Sulfite, Fisher Scientific Company, St. Louis, Mlssour Cat. No, S-tj50 in unstandardized solution. Keicht 63 crams; dissolve in water and maico up to 1 liter. b. N,N-Dlroethyl Formamido, Fisher Scientific CO., St. Louis, Missouri, Cat. No. D-119. o. .Sodium Hydroxide 50?S solution, Fisher Scientific Company, St. Louis, Missouri, Cat. No. S0-S-251*, in unstandardized solution. Add 52. Jt ml to 500 ml distilled water and make up ' to a liter. d. Hexane; nonosrade (Malllnc'.crodt Chemical Works, St. Louis, Missouri, Cat. No. ^4159) 'i S. Silica Cel Grade 938 Darison Code 938-08-08-226 Davison Chemical; Baltimore, Maryland, 21203. t.' Crushed ice. MOMS 054018 SAMPLING PROCEDURE: 1. Measure stack diameter and determine minimum number of sampling points needed. . . ' 2. Measure stack temperature .. ' 3.' Determine percent moisture. Thl3 may be found from previous . . tests. j! !, , A.' Place sample box on duorail and assemble impingers. Leaving ; the first implnger empty. Fill the second implnger with 150 ml of DMF solution. Add 75 ml in NaOH plus 75 ml in NaaSOj lr. ' the third Implnger. The last implnger will contain 200 g silica gel in a modified implnger. (Weigh silica gel for water determination later). - : . v: 5. ' Place the cyclone and glass fiber filter in the hea't chamber and connect to implngers. ; . *. :6. Connect vacuum line of umbilical cord to inlet of meter box and outlet of last Impimger. Plug up the inlet to the filter ' holder and puli 15 in. Hg vacuum to check for leaks. Leakage rate should not exceed 0.02 C.F.M. ' "7. ' Connect glass probe, to cyclone. . .'8. Complete all connections on umbilical cord. 9. Purge air through pitot tube' using tubing which is attached to umbilical cord and connect to air pump. MO. Pack ice around implnger and add water. . ill. Make a traverse`.of stack on one side to determine velocity and 'stack pressure. Be sure you have balanced draft gage before you take your readings, M2. Heat probe and chamber In box to a temperature of 10 higher than the stack temperature. M3. Record temperature at gas meter, (inlet and outlet.) M4, Use Nomograph to determine nozzle size and Isokinetic sampling rate. . US. Record gas meter readings, MB. As soon as heat chamber in sampling box is up to temperature start'your test. , , HONS 054019 SAMPLE TRAIN OPEKATIOK 1,( For each run, record the data required on the example sheet ' shown in Figure 1-2. 2, Determine the time required at each sampling point. A , minimum time of one hour is required for this test. 3, To begin sampling, position the nozzle at the first traverse point with the tip pointing directly into the gas stream. Immediately start the pump and adjust the flow to isokinetic conditions. Sample for at least 5 minutes at each traverse point; sampling time must be the same for each point. . 4, Record temperature at gas meter inlet and outlet, about one minute before it is time to change traverse points.. AI30 be: sure to read temperature'of last impinger.. . 5, Add more ice during test to keep the temperature of gases leaving the last impinger as low as possible and preferably - at 70 F or less. . 6, Turn off pumps at the conclusion of sample run and record final reading. . . . ' T-. Remove probe -from stack and disconnect from impingers. Take pitobe and impingers and prepare them for lab analysis. B. Measure the increase in volume of each impinger plus the increase in weight of the silica gel to determine percent water. Rinse probe and cyclone with hexane and pass rinsing through glass fiber filter. Mix this extract with the water (condensate) from the first impinger. . ' ID. Carefully remove the filter pad plus rubber washer and dry in oven then place in desicator before weighing for particulates. 20. Collect all washings and give to lab for analysis. 32. Upon receipt of analysis from 3a b, record results in grams ' on sheet shown in Figure 1-1 and complete for computer run. HISCUSSIOT;: ^ . M0NS 054020 Ibc collection system in this test may also be used to determine other components of the stack gas. The ones of moot interest would "be HC1, H3PO4, and Cla. To do this have the lab save all aqueous JUiyors from washing used in preparing the solutions for PCD ana.l;/si a. Take the aqueous layer from the first impinger (water condensate) and run for I1C1. and HsPO-i analysis. Analyze the dimethyl formmidc *om the second impinger for Cla and II3P0,. and the KaaS03 impinger for Cla. 'tv i r 771 Numb* r of sets of data (1-2) 2 [ "unbar dtonponents to be analyzed . .. i " 3 iil'Ti? lui uifl 1117)7131 1 11 I- 13loI I ply,I I t7toic"l/iA-l/=lfllAiriff|g| Mrfclcfe|~i~n T I I I (1-12) Date (13-20) Tine (21--^4) Stack Samoled ci* a kill JB Zones 7T?1-Tg>rT1 lnEMZHUhe \q\- \s\7\s\ in. (6p-<t8)Saj rce OpNo. (69-50) (5i-56)StackDlan\.(5Y-gi)Bar. (62_66)Nozzle (67-72-Stack Via R-! 3IZ-/I. ;/) I . \i-5) Process VJt. ETO.ytolsl \mrXltHo\o\R\ I 7 ITI fl I I ITITi M iTTT (6-^0) Units of production per hpur '^1/K.I / \:j !/-!:/1 l<Uv lo i idia[/J/ l^U-lctV-lg|,/jr (1-pC) Sampling dene by: J..LI 1. .L I.1 c |gj7m:M.tigir|glg'k?i i#Ui h'-i loUiiri 1/.-ul->ki*|3I i/kh>\)U-\umis\ I i i i 11 i t (1-63) Sampling Metliod - Indicate modifications x i- v?io i&i "EEEli; Correction Factors Decrcc.n^TTI CEntigrade or FAhrenheit " likll-3| (>l-y^) Orifice (55-53) Pitot (59-30) '. (61-66) Teter .- las Analysis in .Vo)c-Fractions (Identify Component Z If Present bv t'.W. and name or formula) i im RCTi^vi i t i i i 11 i^iVig I I lionoi EvR Erign n 11. (1-5) 02 (6-10) No (11-15) C02 (16-20) CO (21-25)H20 (26-30) Z (31-36)PKZ (35--J*3) r.arc of Z Pfir /fe i'olsturo determination by absorption on Accarite and weighing ' ' Leak test on Sampler kia.Q/!iUc-F- [MiifeiJ i )oiiio)"Hcr7ra7i;Md i f7i?TRr1 (1-6)SariplcVo 1. (7-ll)Tomp. (l2-15)Press (16-23) Tare v/t.. (26-31) Cross wt. (32-36) C?.- aitj'-STJTrreessa Analysis for Components p&iiirii dy !l A-lr pi- id.! . ! 1 | "T1- i i/.iti i' i 1 '< \7 2 i-r Vlrr 71/ 3 0 6> f CM K :) 0 0 .' 0 0 o 1-I1)Kamo of Comp. (12-15) (l6-25)Tare Vt.(c) A ft,.. Ilct ' 3,0,.S' H.tf. T 1S' ,iUW 6 V (v rz 0 t A olo It? 1 / 2 0 , 0 >li> / li h olf 0# 0 J.-L.L (26-35)cfroas Wt.(g) (36-*7)`Kow determined * M0NS 054021 * -I --PltOt staex H Velocity Heed. Tenp. .Deg. St a<sk'?r Qtss in clies h 2() HP '.'S FS SkI f7-7l , XK -rV III )\L!\o\- bb .Vf 7 1/ ,?!, 1/ sb (Mol. Ub n\- ?bb !' <?U7 /.!/) I `viol- b'o J. ?bb 1 'If.3 at "Meter end of Volume iit ZONE end Un . ZONE Cu.ft. 0T_?71 VM _XX(U-20_ n b r/ f0 b lo 73 *!. 9 0O' Jb . 0 01 Tccp. W=Het D=Dry Deg. Inlet at Outlet At start end ZONE at end ZOKE of ZONE In Hg TC TKI TKO PHI . --05=351! f -UtSjHpi- . T 'Of. Ulvi-b rwF Q 6 blrlT oil 0 M| V U -0 s/o\Xo wvi 0 ! ;. ! | 'res s*.ire A t end LC roi s of OrifJice Z GllS I n Hg PI-s2 f HO cc. ;o> tmdDll 1 1 d-1/ o'o. ! 1 3!. k 9\c ;= o', ubio i'vloi. b-o ol. yb b 3!/ , 0 -/ 1 SO '0 *9bi. b vr\. 0 ' 1. i 1 JJ 3!- |7 do. -u f. !/k u T/;<fMeVror <JL frbb !C r. l/bb o\ 7b b dAite'o Tb!. nU (7 i?17W H*7 *U/ do )W\ol db (7 . L/b a .0 PV'O .7 0 Z'Ct o 3.t/W\ G 9 bz . r> 2 Vf/ , 7 b / 0 xc 0 03. '& ro\o\-b :7v?i- 1 ifU. 0 9l3l- \o 0 Q O - 0 1 o\l\M 77 , /, &.Q- 0 rox,J. h Ml O ill! :!'! !!!i n. ii 11 u-l 11 IfSxc m-Jorn j-bb d. fi9\o 'CA -il Vi o Tbi. o t 17 0 or , r> $(M 7 1? (te\- 0 /obi 5 ,0 I i ! 1 1 i si. .713 lo i !1 i :11 ii TIT j ; 1 i `IT i1 1 i1 lI I- 1 1 1 : 1 : l | i 1 !; i i ! i!'j j 1 l.l i > 1 1 1! i 1'i !I !| Is! 1 ! !1!i | i 1!I i1 1 MM . 11 T i ii i 1 1 1i !1 *i 1 1l ^ 1 ; JL ! 1 i ; i! !1 T i ill! i 1 T i im 1! i ; > sill ii j i i r 1 1ii i i1!! 1 ! !N T> i I ! ! si i ' --ij--1Jt--! 1 i i l 1 I j 1 i --"J-- -H|1i1--- T--ji-- 1 i i ! 1M IT i T Mi Tr II i * 1 n) r "*i--I T l i1 --?ji !*. i 5 i 1 Ii ! ! 1 M!i ~1 r ill! 1 Ih! T 1 1!' ; ili ?' ; iS \ %; ii i 11 1 1 1 !1 -: !1 s jj j. 1 ;j 1 :i j i !1 1 . : 1 i1 :11 1!!i ; 1! 1 i1 iI i! 1 Mi 1 ! i [ 1 1 1i ! i MIL i ! 1 i M 1 I! 1 , I i J_L 1 t !1 i11 ;'! !i i i! 1i 11! ;! 1 !1 i: 1 s MM ;. 1 1 \i\ MQNS 1-1 J. L 054022 ~ =L - =k. jl | ' | 1 | | | | 1 | l i t I I l I I ! I I I . I I I I I ' APPENDIX B STACK TEST COMPUTER PRINTOUTS MONS 054023 ..I.KIO INDUSTRIAL CHEMICALS CO. 'I . tvUMMRIDI plant SAUGtT.lL 62201. 10 NO. 63 121 AAC -- LLPT 12 1974 START TIMS 1 :00 PM . SAMPLED- INCINERATOR ' SOURCE OPERATION NO. ill 'L(iiG DONE BY NEIL SULLIVAN AND ED riEUNANN I ' JUG METHOO-EPA METHOD ,75 DMK AnO NA2S03 IKPINUERS I iation of emission hate of aiparticulate B:P.C.B. C:hCL D:H3P04 WEIGHT PaTE= 772.00 POUNDS PER HOUR .SULT: . 1 /ACTUAL CFM AT /STD CFM DRY STO CFM / / STACK CONDITIONS/ AT 70 DtG.F AND 29 .92 IN. HG/ ZK VOLUME 1903.1 1803.8 1711.6 T.MIST .OR GAS CONCENTRATION IN WET 6 DRY STACK GAS AT STD conditio; .PONfc'NT A: a: GRAINS PER CUBIC FT 0.070B 0.0746 LBS; PER MILLION CUBIC FT 10.1163 10.6611 B 0.0000 0.0016 B: 0.0000 0.0019 LBS. PER MGS. PcR parts 1000 CUB IC PER ,BS. GAS METER MILLION 0.1331 162.0406 134.9248 in WK7 o-V* 0.1374 170.7756 142.1910 IN Oi< Y ClA1. 0.0000 ' 0.0289 0.I10C0 0.0304 0.0028 IN 'wffT GA< 0.0029 IN [MY OAi Cl 0.0307 4.3616 0.0576 70.1866 46.4300 IN WET GAS 0! ;0.0323 4.6176 0.0595 73.9665 48.9313 IN OKY GAS D: 0.0827 11.0131 0.1554 169.2287 46.6235 IN w;*: t GAS d: 0.0671 12.4493 0.1604 199.4194 49.1344 IN OKY GAb SSJON RATE: 4SUO lbs. per PMMiNT HOUR AS 1.0948 u s OiOOO? cs 0.4742 DS 1.2785 GRAMS PEN SEC. 0.137? O.OOUO 0.0597 0.1611 LBS. PER UNIT UF PRODUCT ION 0. 0014 0. 0000 0. 0006 o. 0017 MONS 054024 MONSANTO INDUSTRIAL CHEMICALS CO. W.fi. KRUMMRICH PLANT SAUGliT.lL 6X201. ID NO. 63 121 AAC OATF. SEPT )?. 107'. START TIME 1:00 PM STACK SAMPLED- INCINERATOR SOURCE OPERATION NO. 831 FIELD DA TA:i ORIFICE CONSTANT K = 0.506 PITOT TUbE FACTOR FS= 0.03 TEMPS. RECORDED IN Fa DEGREES METER CORRECTION FACTOR* 1.02 j 6AS ANALYSis: Z=NONE ' MOLECULAR WTOF z* 0.0 MOLECULAR WT. OF STACK CAS a 29.AO DRY MOLECULAR WT. OF GAS a 30.02 02 N2 C02 CO H20 Z VOL TW Pw i 0.100 0*102 0.092 0.0 0.051 0.0 AO.630 100.20 29.6A A3. particulate P.C.S. "" HCL H3P0A determined hy DETERMINED OY DETERMINED BY . DETERMINED BY wy weight "HY WEIGHT. BY WEIGHT BY WEIGHT = o.iw. grams a ` 0,0000 GRAMSO.. ' a 0.0816 GRAMS a 0.2200 GRAMS .LEAK TEST ON EQUIPMENTS. 001 CFM AT 15.00 IN.HG -BAROMETER* 29.6A IN.HG5 STACK DIAha 19.000 INTT NOZZLE OIAM a 0.375 . - VEL STACK STACK TIME VOLAT CONU METER TEMP METER PRESS FLOW-: MEAD TF.MP PRESS A TEND END TEMP START FIN OW1FI -ZONE HP 0 0.0 ) 0.060 2 0.080 .3 0.09S A 0.095 :5 0.065 6 0.080 7 0.090 8 0.090 TS 95.0 95.0 95.0 95.0 95.0 95.0 95.0 9S.0 95.0 H20 ZONE ZONE 0.8 0.0 935.30 o.a 8.0 939.71 0.8 16.0 9AA.7A 0.8 2A.0 950.22 O.B 32.0 955.71 0.8 AO.O 960.50 0.8 A8.0 965.28 0.8 56.0 970.65 0.8 02.0 975.93 IN OUT D 90.0 90.0 64.0 98.0 90.0 6A.0 106.0 91.0 65.0 1 11 .0 92.0 65.0 H 1 . (i 94.0 63.0 106.0 95.0 6A.0 1 lu.o 98.0 65.0 113.0 97.0 68.0 11A.0 97.0 HG 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 HG H20 0.0 0.0 0.0 1.16 0.0 1 .58 0.0 ) .AS 0.0 1.(151 0.0 1 .281 0.0 1 .581 0.0 1.751 o.o 1.75c HONS 05A025 MONSANTO INDUSTRIAL CHEMICALS CO. V.C>. KRUKP.RICH PLANT SAUOcT.il 62201. 10 NO. 63 121 AAC DATE SEPT 12 197A ST ANT TIKE HoO PM . . STACK SAMPLED- INCINERATOR SOURCE OPERATION NO. 031 CALCULATION AND EVALUATION: THc ISOKINETIC CONSTANT HO/HP EON THIS EOUIPMFNT IS 23.626A the TAULE BELOW SHOWS.FOR Lack ZONE'YMc METER VOL.- and [HE AVG. ;-.f TFlK ; AND PRESS. IN ARSOLUTE UNITS. FROM THIS IS CALCuLATFl) TiC EQUIVALENT V( STACK CONDITIONS AMO DIVIDED HY TIME TO GIVE THE FLOW IN THE MOTTLE. It compared w ITH The ISOKINETIC FLOW Rate calculated from the STACK veloc PERCENTAGE DEVIATION is wecordeo. SAMPLE/STACK/aVG. PRESS/ AVG. temp/sample vol./sample rate /p.c. ZONE time VEL. METER stack METER stack METER STACK actual ISOMN DEV 1 8.0 13.8 29.7 29.7 552.0 S55.0 A.A *.e 0.60 C.6A -6.3A 2 8.0 16.P 29.8 29.7 566.3 555.0 5.0 5.A 0.68 0.7a -B.00 3 8.0 17.A 29.8 29.7 560.0 555.0 5.5 5.9 0.73 0.80 -8.67 A 8.0 17.A 29.ft 29.7 562.0 555.0 5.5 5.ft . 0.73 .0.80 -rt.b.1 5 8.0 1 A. A 29.7 29.7 561.5 ,555.0 A. 8 5.1 0.6A 0.66 -3.1)8 6 8.0 16.0 29.8 29.7 562.3 S5S. 0 A.8 5.1 0.6A 0.7A-13.60 7 8.0 16.9 29.8 29.7 S6A.5 555.0 5.A . 5.7 0.71 0.78 -6.SI B 6.0 16.9 29.6 29.7 565.3 555.0 5.3 5.6 0.93 0.76 19.39 TOTAL 62.0 16.1 29.8 29.7 560.5 555.0 . AO.6 A3.3 0.70 .G.7A -5.75 <> <> T AV AV . AV AV AV 1 1 AV TOTAL SAMPLE VOL. CORRECTED FROM STACK CONDITIONS TO SID CONDITIONS* 41.06 CUBIC FF. OF WEI GAS TOTAL SAMPLE VOL. CORRECTED TO DRY SIO CONDITIONS * 3ft.9b CUftiC FT. HONS 054026 5* MONSANTO INOUSTRUL CHEMICALS CO. vT.g'. krumm'rich plant saugetTil '6i'2oir'ii) No: M f?7 AAC OATE OCT l 1975 START TIME p.30 PM . STACK SAMPLED- INCINERATOR......... ... ..SOURCE OPERATION NO. SAMPLING DONE BY NEIL SULLIVAN AMD ED HEUMANN ' 831 ' _ SAMPLING METHOD-EPA .METHOD MS .. OMp AND NA2S03 ..IMPIMGERS__________________ DETERMINATION OF EMISSION RATE OF A!PARTICULATE___ . OIP.C.B. C:CL2 PROCESS WEIGHT RATE.=__ 0.90 _ THOUSAND.. POUNDS .PER HOUR TEST RESULT!. ' /ACTUAL CFM AT /STD CFM . DRY STD CFM / STACK CONDITIONS/ AT 70 DEG.F AND 29.92 IN. HG/ STACK VOLUME 3749.6 3257.1 2353.4 DUST..MIST.OR GAS CONCENTRATION IN WET.4 DRY .STACK .GAS.AT..S.TD. CONDITIONS GRAINS LBS. PER LBS. PER MGS.. PER PARTS . PER ... . . MILLION____ .1000. .. .CUBIC____ . PER. COMPONENT CUBIC FT CURIC FT LBS. GAS meter MILLION A* 0.0725 10.3620 0.1494 16S.9B3S 138.2010 IN WET GAS ____ A*_______ __ 0.1,004. ... 14.3408. ...0,1836....229., 7103 . 19I.?679 IN DRY.. GAS B> 0.0000 0.0011 0.0000 0.0182 0.0018 IN WET GAS _ 0.000.0 ,...... 0.0016 .... . 0.0000 .....0.0252.. ... 0.0024 IN DRY GAS C*. .....c*. .. 0.0079 , 1.1335 0.0163 0.0110 . 1.56B7 . 0.0201 10.1570 25.1290 6.1749 IN WET GAS 8.5460 IN ORY GAS EMISSION RATE! 1 ....... LBS. PER COMPONENT HOUR ____ A!______ . 2.02S0 B> 0.0002 C> 0.2215 GRAMS '~LBS. PEr"0NIT PER SEC. OF PRODUCTION . 0.2551............. . 2.2450 0.0000 0.0002 0.0279 0.2456 MONS 054027 vu W.c. KRUMMR1CH PLANT SAU0ET.1L 62201. ID NO. 63 121 AAC DATE OCT 1 1 <>75 START TIME 1:30 PM STACK SAMPLED- INCINERATOR...................... SOURCE OPERATION NO 031 FIELD DATA! ... ___ ___ ___ __________ _________ _______________ _ ORIFICE CONSTANT K=0.506 PITOT TUBE FACTOR FS* 0.83 TEMPS. RECOROEO IN FA OEGREES _ METER CORRECTION FACTOR* 1.02 I GAS ANALYSIS:. Z*NONE. . _________ MOLECULAR. WJ. O.F..Z*___ 0>.0 MOLECULAR WT. OF STACK GAS = 26.83 ORY MOLECULAR WT. OF GAS = 30.2202 02 N2 C02 CO H20 Z VOL TW Pw WC 0.068 0.818 0.114 0.0 0.277 0.0 30.200 70.89 29.90244. PARTICULATE DETERMINED BY BY WEIGHT(ft* = 0.2002 GRAMS P.C.B<... DETERMINED OY _ BY TfrTit/tf-lON.... =0.0000 GRAMS C CL2 DETERMINED BY BY TITRATION = 0.0219 GRAMS LEAK TEST ON EOUIPMENT=O.OOS CFM AT_.15.00 IN.HG BAROMETER* 29.90 IN.MG1 STACK DIAM* 19.000 IN.I NOZZLE DIAM = 0.37S . ; VEL STACK STACK TIME VOLAT CONO METER TEMP METER PRESS Fl.OWME HEAD TEMP PRESS ATF.ND ENO TEMP START FIN ORIFICi ZONE HP TS H20 ZONE ZONF. IN OUT HG HG H20 0 0.0 149.0 -0.4 0.0 428.50 D 64.0. 64.0 - 0.0. 0.0 0.0 .1 0.200 149.0 -0.4 8.0 431.84 51.0 68.0 64.0 0.0 0.0 0.650 2 0.300 149.0 -0.4 16.0 43`J.82 51.0 74.0 64.0 0.0 ...3 0.340 149.0 -0.4 . 24.0 .439.97 53.0 HO.O 65.0 ... 0.0 -4 0.330 149.0 -0.4 32.0 444.11 55.0 80.0 66.0 0.0 0.0 0.960 0.0 1.100 0.0 1.070 5 0:170 149.0 -0.4 40.0 447.29 53.0 74.0 66.0 0.0 0.0 0.569 6 0.230 149.0 -0.4 48.0 450.84 54.0 80.0 .66.0 .. 0.0 0.0 0.740 7 0.300 149.0 -0.4 56.0 454.84 56.0 83.0 68.0 0.0 0.0 0.960 B 0.270 149.0 -0.4 64.0 458.70 58.0 82.0 68.0 0.0 0.0 0.870 HONS 054028 W.G, KRUMMRICH PLANT SAUGET.IL 62201. II) NO. 63 121 AAC DATE OCT 1 1975 START TIME 1:30 PM STACK SAMPLED- INCINERATOR...............................SOURCE OPERATION NO. 031 CALCULATION AND EVALUATION: " the isokinetic constant mo/hp rori this Equipment is 17.0m . THE TArtLE DELOW shows,FOP EACH ZONE,THE METER VOL. and tme AVG. meur AND PRESS. IN:ABSOLUTE UNITS. FROM Turs IS CALCULATED TuE' EOU1 VALEm'yi STACK CONDITIONS AND DIVIDED ILY TIME TO GIVE THE FLOW In THE NO/7LE Ti COMPARED WITH.THE ISOKINETIC FLOW RATE CALCULATED. FROM IHF STACK VtLOCi PERCENTAGE DEVIATION IS RECORDED. ... SAMPLE/STACK/AVG. PRESS/ AVG.. . .TEMP/SAMPLE VOL./SAMPLE RATE /P.c. ZONE TIME VEL. METER STACK METER STACK meter STACK ACTUAL ISOKIN UcV I _2... 3 8.0 27.6 29.9 29.9 525.0 609.0 3.3 5.5 0.69 1.27-46.07 8.0. 33.8 ..30.0. .29.9 527.5 609.0.... .4,0. . 6.5 ... 0.8] ... 1 .56-47,74 8.0 36.0 30.0 29.9 530.8 609.0 4.2 6.T 0,84 1.66-49.10 4* 810 35.5 30.0 29.9 532.0 609.0 4.1 6.7 0.84 1.63-48,65 5..-.. 8.0 25.5 29.9 29.9 531.5 b09.0 .. 3.2 5.2 0.64 1.17-45.00 6 8.0 29.6 30.0 29.9 531.5 609.0 3.6 5.8 0.72 1.36-47.19 7 0.0 33.8 30.0 29.9 534.3 609.0 4,0 ..6.2, 8__ 8.0,_..32.1.. .30.0 ..,29.9 535.3 609.0 ...3.9 6.5 0.81 1.56-48.14 -0.78 ' 1.48-47.35 TOTAL 64 ;0 31.7 30.0 29.9 531.1 609.0 30.2 49.0 0.77 1.46-47.55 T AV AV AV AV AV T T AV AV AV TOTAL SAMPLE VOL. CORRECTED FROM STACK CONDITIONS TO STD CONDITIONS* <2.59 CUBIC FT. OF VIET GAS , TOTAL SAMPLE_VOL.. CORRECTED TO .DRY. STO_CONOITIONS._=_ . 30.78 CUBIC, FT. MONS 054029 MONsAHIO MOUSTkIaL CHEMICALS CO. V.'.G. KT<UHMR[CH PLANT SAUOF.T.IL 62201. 10 NO. A3 121 AAC CATE :aY 23 1975/ START TIKE 10 : )0 AM . STACkVl^pIJElLv-'^InCIMEMA IOH STACK SOURCE 02EWATI0.-I NO. 831 SAMPLING DONE BY NEIL SULLIVAN AND EO H SAMPLING METHOD-EPH METHOD a5 (. UMF AND NA2S03 IMPInGERS DETERMINATION -OF EMISSION RATE OF a:PARTICULATE B:P.C.. ' C:HCL 0: CL2 PROCESS WEIGHT RATE= 1.00 THOUSAND POUNDS PEP HOUR TEST RESULT:, /ACTUAI.. CFM AT /STO CFM DRY STO CD / STACK / VOLU ;.;c STACK COKDITIC'.S / 17)1.6 . AT 70 DEG F 164V. 0 AND 29 .92 In. 1569.5 DG:/ DUST,MI ST, OR GAS C0\,'CENTRAT ION IN WET S. 0 :.y stack AT 5"; c: :' COMPONENT A: A: .GRAILS 1 PER CU.-ilC FT 0.0522 0.0549 LBS. PFR LBS. PEH mgs. PER PARTS MILLION 1000 C'.;1C PL.-; CUBIC FT LBS. GAS ML ; - : 1 ILLI ON 7.4602 0.09*2 119. SOLS 59.4986 i;; 7. T fj \ 7.*383 0.U991 125.5S*0 104.5420 IN oar o B: 0.0000 0.0016 u.oooo 0.0?S7 0.002S It-: ivT 0 .3 8: 0.0000 0.0017 0.0000 0.0270 0.002& iW 0*Y G* 5 C: 0.0027 0.37*7 0.0049 6.06S6 4.0126 iN l-.cT G;.S Ci 0.0028 0.3979 0.0050 6.3731 4.2160 IM 0<Y GmS D: 0.0021 0.2970 0.0038 4.75*0 1.61*1 IN .v/ET c \; 0: 0.0022 0.3121 0.0039 4.9991 1.7001 IN DWY \) - V EMISSION RATE! LBS. PER COMPONENT HOUR . A: 0.7331 Bi 0.0002 C: 0.0375 OS 0.0294 GRAMS PER SEC. 0.0930 o.noon 0.0047 0.0037 LRS. PER UNIT OF PRODUCTION 0.73R1 0.0002 0.0375 0.0294 HONS 054030 HDNrAN It) INDUSTRIAL CHEMICALS CO. ' W.G. KHU.-tMRICII PLANT SAUGCT.IL 62201. 10 MO. 63 121 AAC OATC MAT 23 197S START YImL 10:30 AM STACK SAMPLED- INCINERATOR STACK SOURCE OPERATION MO & 6 31 riCLO OATA: ORIFICE CONSTANT K=n.Sn6 PITOT TUtlC FACTOR FS = 0.B3 TEMPS. RECORDED I'l FA DEGREES METER CORRECT ION FACTOR 1.02 GAS ANALYSIS: Z = N0i\iE MOLECULAR WT OF Z 0.0 MOLECULAR L'T. Or ..STACK GAS = 30.00 DRY MOLECULAR WT. Or GAS = 30.60 ------------------------- ;----------- 02 N2 CO? CO R20 - z VOL TW Pw 0.028 0.82A 0.1A8 0.0 O.OAB 0.0 45.630 11,.90 29.6l LG T PART1CU! P.C.B. HCL Cl_2 DETERMINER AY DETERMINED GY DETERMINED p.y DETFRMI MED OY KY WEIGHT KY WEIGHT KY WEIGHT KY WEIGHT * 0.1517 GHAU-. = ' o.oooo gka.".- r = 0.0077 OR...-.- a 0.0(160 GW a: 3 LEAK TEST ON EGUIiMKMT = O.OOA CFM AT IS.00 IM.HG HAROMETER= 29.64 IN.HGI STACK OIAHs 19.000 IN.: NOZZLE I) I AM 0.375 VEL stack STACK TIME VDLAT CONO METER TEMP METER 19HESS 1 HEAD TEMP PRESS ATENO END 'TcWP START 1FIN I 1 r i Ct ZONE mp TS H20 ZONE 7onf: IN OUT HG HG H20 0 O.o 66.0 O.H 0.0 926.60 0 66.0 o*.o 0.0 0.0 o.o 1 0.0R0 66.0 0.8 8.0 932.60 0.0 1 0 6 0 5*.0 0.0 0.0 1 . V20 2 0.090 86.0 0.6 16.0 938.71 0.0 122.0 1U<*.0 o.n 0.0 2.160 3 0.060 P.6.0 0.8 PA 0 9AA.A8 0.0 132.0 O.o 0.0 1 .^rU 6 0.060 66.0 0.8 32.0 950.04 0.0 1JA.0 ma.n 0.0 0.0 l.'.jfl S 0.9S0 66.0 0.8 40.0 955.7A 0.0 128.0 1 10.0 0.0 0.0 1.2.?0 A 0.070 66.0 0.8 A8.0 960.50 u.o 13a.0 nz.o 0.0 0.0 1 . 7 0 0 f 0.0 70 86.0 0.8 S6.0 967.85 0.0 13A.0 11^.0 ' 0.0 0.0 1.760 a 0.070 66.0 0.8 6A.0 972.23 0.0 13A.0 llfl.O 0.0 o.u 1.700 HONS 056031 MONSANTO INDUSTRIAL CHEMICALS CO. V/.G. KRUMMRICH PLANT SAUGET.il 62201. id NO. A3 121 AAC DATE MAY 23 1975 START TIME 10:30 AM - STACK SAMPLED- .INCINERATOR stack SOURCE OPERATION.NO. 831 CALCULATION ANU EVALUATION.' THE ISOKINETIC CONSTANT HO/mP FOR THIS EQUIPMENT IS 24.7938 THE T AttlC UELOli SHOWS. FOR EACH ZONE.THE METER VOL. AND THE AVG. ME! ER 17 ANO PRESS. IN ABSOLUTE UNI TS. FROM THIS IS CALCULATED TuE EOUIVM.:.:., v.,l STACK CDNuITIONS A.:n DIVIDED RY time TO give THE FLOW IN THE NU22LE. iril compared with the isokinetic, flow ratf. calculated from the stack vElocit PERCENTAGE DEVIATION IS RECORDED. SAMPLE/STACK/AVR. PRESS/ AVG. TEMP/SAMJLE VOL./sample rate /h.;. ZONE T|K VEL. METER STACK METER STACK METER STACK ACTUAL ir>CKiu i:. v 1 M.O 15.7 29. 8 29.7 553.0 546.0 6.0 -6.4 O.on 0.72 1C.2J 2 u.o 16.6 29.8 29.7 566.5 546.0 6.1 6.3 0.79 0.7 7 j.-.-j 3 M.O 13.6 29.7 29.7 575.5 546.A 5.8 5.9 0.71 0.63 17.'.*? 4 *.0 13.6 29,7 29.7 579.5 546.0 5.6 S. 6 - 0.7 r, 0.3 ] ;j. ' .2 S M.O 12.4 29.7 29.7 580.0 54 6.0 5.7 5.8 C.7? 0. b 7 r: 6. . . 6 8.0 14.7 29.H 29.7 581.0 546.0 4.8 4.8 0.6n 0.66-1i. . 3 7 8.0 14.7 29.8 29.7 583.5 546.0 7.3 7,4 0.92 0.6B 2^.7'. R 8.0 14.7 29.0 29.7 585.0 546.0 4.4 4.4 0.55 0.68-13.ia TOTAL . . _ 64.0 14.5 29.8 29.7 575.5 546.0 45.6 46.5 0.73 0.67 9.04 7 AV AV AV AV AV T T AV AV AV TOTAL SAMPLE VOL. CORRECTED FROM STACK CONDITIONS TO STD CONDITIONS; 44.83 CUBIC FT. OF WET GAS TOTAL SAMPLE VOL. CORRECTED TO DRY STD CONDITIONS = 42.67 CUBIC FT. MONS 054032 H.!;i:vir.ti:rr!-..:TAi. imoiy;ci n<.: ,v:;.;:cv !:;kh*;: v aik stack ti:mt i;'u;;u! n':vn:.' .vjKrrm :;,;cri.v: co; it'AiJV________________________________________ stack ihKTnnc.vrioi: vr:r; rx^K'.r.wa!:____________________ ru:i vju 'iir.K____________ ;wYi: ov >;?: nmt. .2, .07a & 1. AiwunC ni water collected (nil'll iicrr.) Voltinc of water vnpop ollcclcd (.'?!) " 63. V2.0Sj7r. 2. Dry j.m notcv volure at .xtcr conditions (cubic rrpt) 40, rj barometric nrcnnure (incbcB of t*ereuv") 2?. f >> Avoray.u "riiice prcMtiure >!ron (Inane* 0/ water) l.fr*'> Avcrnrc netcr tcrpovnture 100 *F 3. Can nntor volune nt ST" (dry cubic feet) 33.72 4. Percentage of roleturc In ina strcim 5.1'' V, 5. Percent composition of c ntrenr.: .1 0>;yr,en....................... 1-0. r-TJ I Nitrogen............. j Cnrbon iUouioe... 9.2f'~ 1 Cnrboo "ono:;5 iv... . 00". C. Poreo:it.v,o of o::coaa air " 100.25E 7. Dry Molecular trelphs .* saa etron.i (li>./lb-r*ole) - 29.?3 Uet molecular wp.ij.u 0/ &a ntrenr* (lb./lb-relc) 2?..73 0, Plttt tub< coefficient (di*.-oo*i<mle.ao) .03 ilunimr of pitot tube i*cadi:*.-3 .0 Avcrny.c o nnuarn roots o: velocity pressure". Average p,i ntrc&n tc-:;>ovntnr (*") * 9.")*" Coo utrcaii velocity (it/noc) lA.10*i Pitot tube roo-.llncsJ .2032 . .06 . 03 . 09 .03 .on ,03 .09 9. Stock dimensions, circular with di.v-.cier (feet) 1.33 . Stock area (square feet) 1.96 Voluixctric flow at STP (cubic fect/min) 1710 M. Soxr.lo dimeter unc.l for snnplinf, (iueben) .273 Coupling tlnn (nimitos) *2.r'3 Ueifikt of portlcnlote matte;* collected (nilli;:r;n) ,03 11. Partleulntc concentration (ib./SCK) ,nnoonop Particulate concentration (5raiu/!Cl) .0OO013 Pnrtlculoto concentration r.orrccln.) to ro 7. oneera air (lb. /CP) .n?ov*nj Particulate concentration corroctoJ to SO 7, execaa air (-vnin/tT) .noon*: 12. Iaoklnetlc rate (7.) - 92.15 . 13. liana cnionion rate (lb./hr) .09 Pat. AX/. / . / 7 i Si-naturc HONS 054033 u.r.. rivi'urriiNr.u. iMtvi'r.ctn>:; .v:;::irv ixm:: v Air. s'un.iui svac< Twsv r.*:vi::w . *>:; cin'AiK____,'t;qa::to________________________________________ stack i:->r::iTiric.vrio:; "O !;:ct:ta___________________ issri mitlu:k__________ n.vn: nr mr; *>v m7r, s'!)1 1. Anonnt of enter collected (nl J.2115 trrs) Volnnc oi water vapor collected (3iY) 4'.70 2.11S73 2. Dry p,ne nctor vnlur.o .it r.ctcr coj.Ut.lonn (citMc foot) 41.43 Baronetric prentnne (laches o uarcvtry) " ?.?..A4 Average orifice proam-iT drop (inches of w.itor) 1.A40 Average rioter tcvperntur* 11A *F 3. Cao rates voluna nt ST? (dry cubic free) - Al.07 4. Porccnt.v.e of noleture in cfls strean - 4. SI 5. Percent composition of gas acreom: - . j Oxygen....................... 2.AT' Nitrogen.................. 32.AT: Carbon Din:;i:ln... 14.ST: ' Carbon llonor.ido.. .09?: * 6. Percentage of excess air - 14.7771 7. Dry nolcculnr weight of gas stream (lb./lb-*vlc) 39.48 Wot iwlocul.it weight of gas stream (lb./lb-role) 29.37 0. Pitot tube coefficient (dinuaslonlcss) * .S3 Dumber of pitot tube readings E Avnragc of square roots of ve.lncit" pressures .2*12 Average gas ntrcin tr-v'eirtuvc (*'.*) Sf.*T On* etrc.i.5 velocity (ft/sec) - li.53'> ritot tube readings: .OS .09 .96 .06 .95 .07 .07 9. Stack cllRonslons, circular with din**ete.r (feat) 1.50 Stncl; aro-i (square foot) 1.93 Volunocrlc flow ac Sir (cubic feet/rin) 1560 .07 10. Wo;:r.le dinnoter used for sampling (laches) .375 Snupllns tine (rlnutcs) 64.00 Weight of particulate natter collected (rllllgrn-.) - .*3 Hi. Pnvtlculnca concentration (lb./SC?) . n-ioo-yv; Particulate concentration (grain/ECF) .001013 Particulate concentration corrected to 50 V. e:;cfii niv (lb./CP) > .nnooniq Particulate concentration correct*):! to 59 ?. excess air (r.nJn/CD " .090999 112. Isokinetic rate <") " 196.64 13.' t'ooe emission ratn (lit./hr) .00 - Dnte_ /./t 7<> HONS 054034 1 co'.n'.\:;v Tlonannf.o stac:;; iij::?rrincATio:; m/:i w* T c ncrntor datu o? iu;:: Oct. 1,1075 1. Amount of water collected (nillilltors) * Volume of water vapor collected (ST") n 244.41 1.1. 59451 2. '. 3. Dry 303 neter volume at Meter conditions (cubic feet) Barometric pressure (Inchon of Mercury) 79,90 Average orifice pressure drop (inches of eater) .340 Average neter temperature ` 71 *F I Cos neter volume at S7P (dry cubic feet) 30.13 3^.20 4. Percentage of moisture in gas stream - 27.75 Z 5. Percent composition of gas stream: . Oxygen......................... Hitvogen.................... Carbon Dioxide... Carbon Uonoxide.. 6. Percentage of excess air - 45.96" 7. Dry molecular weight of gas stream (Itu/lh-nolo) 30.0? Vet jaolccular weight of gas stream (lb,,'IV.-: ole) " 26.73 S. Pitot tube coefficient (cilr'cnsi*nler.3) * .33 .Number of pitot tube readings C Average of square roots of velocity pressures Average gas stream tenpernture (*T) * 143*? Gas stream velocity (ft/nec) * 31.32.5 Pitot tube readings: .513? .20 30 .27 17 5. Stack dimensions, circular vita dianctcr (feet) * 1.53 Stack area (square feet) * 1.96 Volumetric flow at ST? (cubic fcot/nin) 2352 * in. !!ozle dinnotor used for nnrmling (inches) * .375 Sampling tine (minutes) - 64.09 Weight of particulate natter collected (milligram) .02 U. Particulate concentration (Ih./SCV) ,00A0003 . Particulate concentration (y.rain/SCP) .033011 Particulate concentration corroded to 5? 7. excess air (lh./C!S7). '** .'y'r/noo Particulate concentration corrected to 59 7. excess air (grnl.n/C7) ,A?AA1? 12. Isokinetic rate CO - 51.23 13. Mann cr.inr.ion rate (lb./In-) .or) HONS 054035 :>a t e_EL_s_fjj_y_ c_____ _. /yn -<? (V MONSANTO INDUSTRIAL CHEMICALS CO. W.G. KHUMMRICM PLANT SAUGET IL b2201. ID NO. A3 121 AAC DATE MAY 23 19/5 START TIME 10:30 AM STACK SAMPLED- INCINERATOR STACK SOURCE OPERATION.NO. 831 CALCULATION AND EVALUATION: THE ISOKINETIC CONSTANT HO/HP FOR THIS EQUIPMENT IS 20.7938 THE TAMLE BELOW SHOwSFOR EACH ZONE<THE METER VOL. ANO THK AVG. METER TEMP AND PRESS. IN ABSOLUTE UNITS. FROM THIS IS CALCULATED ThE EQUIVALENT VOL. t STACK CONDITIONS and oivioen BY TIKE TO give the flow in the NOZZLE. THIS I COMPARED WITH THE ISOKINETIC FLOW RATE CALCULATED FROM THE STACK VELOCITY. PERCENTAGE DEVIATION IS RECORDED. sahple/stack/avg. press/ avg. temp/samjle vol./sample rate /p.c. ZONE TIME VEL. METFR STACK METER STACK METER STACK ACTUAL ISOKIN1 OEV v----H.0 15.'/ 29.8 29.7 553.0 546.0- --6.0 -6.4- -0.80- 0.72 10.23 2 3 H.O 16.6 29.8 29.7 546.5 546.0 >1.0 13.6 29.7 29.7 575.5 546.0 6.1 5.8 6.3 5.9 0.79 0.71 0.77 0.63 137..3489 4 A. 0 13.6 29,7 29.7 579.5 546.0 . 5.6 5.6 -0.70 0.63 12.42 5 8.0 12.4 29.7 29.7 580.0 546.0 5.7 5.8 0.7? 0.57 26.08 6 8.0 14.7 29.8 29.7 5H1.0 546.0 4.8 4.8 0.60 0.68- 11.06 7 8.0 14.7 29.8 29.7 583.5 546.0 7.3 . 7.4 0.92 - 0.68 36.74 A 8.0 14.7 29.8 29.7 585.0 546.0 4.4 4.4 0.55 0.68- 18.72 TOTAL i ' -- 64*0 14.5 29. B 29.7 575.5 546.0 45.6 46.5 0.73 0.67 9.04 T AV AV AV ' AV AV T T AV AV AV TOTAL SAMPLE VOL. CORRECTED FROM STACK CONDITIONS TO STO COrtOITIONS- 44.83 CUBIC FT. OF WET'GAS TOTAL SAMPLE VOL. CORRECTED TO DRY STD CONDITIONS 42.67 CUBIC FT. HONS 054036 MONSANTO ..IN.D..U.S..T.R..IA_L__C_H_EM.I.C.A..L.S..;..C..O... ... ....... .. w.o. kiiummhich plant 'sauget.il 6?2oT.~"Td no: A3*T?raac OATE OCT 1 197S START TIME 1:30 PM STACK SAMPLED- INCINERATOR ...............................SOURCE OPERATION NO.' SAMPLING DONE OY NEIL, SULLIVAN AND ED HEUMANN I ' SAMPLING METHOD-EPA METHOD *5 ` OMF AND NA2S03. IMPINGE.RS_ ~ 831 DETERMINATION OF EMISSION RATE OF ' A SPARTI CULAT.E. B1P.C.B. , CICL2 PROCESS WEIGHT.RAIE*_,_.0.90. .THOUSAND...POUNDSJ>ER HOUR TEST RESULT! . : i /ACTUAL CFM AT /STD CFM DRY STD CFM / / STACK CONDITIONS/ AT .70 DEG.F AND 29.92 IN..HG/ STACK VOLUME 3749.6 3257.1 23S3.4 OUSTiMISTOR GAS CONCENTRATION IN WET.6 DRY.STACK GAS AT STD CONDITIONS GRAINS . LBS. PER LBS. PER MGS. PER PARTS ..PER ..... MILLION. ........ 1000 .. CUBIC ... PER COMPONENT CUBIC FT CUBIC FT LBS* GAS METER MILLION A* 0.0725 10.3620 0.1494 165.9835 138.2010 IN WET GAS :____a?______ .. P.I004 ... 14.3408. .0.1836 229.7183 191.2679 IN DRY GAS 0.0000 0.0011 0.0000 . . ,.b: . . . .. 0*0000 .. 0.0016 0*0000 0.0182 0.00)8 IN WET GAS 0.0252...... 0.003* IN DRY GAS c. 0.0079 1.1335 o;........ _.. 0.0110 ____1.5687. 0.0163 18.1570 .0.0201 . 25.1290 6.1749 IN WET GAS 8.5460 IN DRY GAS EMISSION RATE: ' LBS. PER COMPONENT' HOUR ___A*;. . 2.0250 0f*: 0.0002 cr 0.2215 GRAMS PER SEC. 0.2551 0.0000 0.0279 LBS. PER UNIT OF PRODUCTION 2.2450 0.0002 0.2456 HONS 054037 W.G. KRUMMRICH PLANT SAUGET.IL 6220]. ID NO. 63 121 AAC ' DATE OCT 1 1075 START TIME 1!30 PM STACK SAMPLED- INCINERATOR SOURCE OPERATION NO. 831 FIELD DATA: ____________________ ORIFICE CONSTANT K = 0.50<i PITOT TUOE FACTOR FS* 0.83 TEMPS. RECOROED IN FA DEGREES ; METER CORRECTION FACTOR* 1.02 GAS ANALYSIS!.Z-NONE_____ `_____ MOLECULAR. W[_0_2? 0.0. MOLECULAR WT. OF STACK GAS = 26.83 DRY MOLECULAR WT. OF GAS = 30.22 02 N2 C02 CO H20 2 VDL TW PW WGT 0.068 0.818 0.11A 0.0 0.277 0.0 30.200 ,70.89 29.90294.61 PARTICULATE P.C.B. CL2 DETERMINED BY DETERMINED BY DETERMINED BY BY WEIGHT G(* * 43Y WTUATION ...a BY TITRATION = 0.2002 GRAMS 0.0000 GRAMS O.o 0.0219 GRAMS LEAK TEST ON EQUIPMENT = 0.005 CFM AT.. 15.00 , IN.HG BAROMETER* 29.90 1N.HGI STACK OIAM* 19.000 IN.t NOZZLE DIAM * 0.37S VEL STACK STACK TIME VOLAT COND METER,TEMP METER PRESS Fl.O'.METEI HEAD TEMP PRESS ATENO ENO TEMP START FIN ORIFICE ZONE HP TS H20 ZONE ZONE IN OUT HG HG H20 0 0.0 169.0 -0.6 0.0 620.50 0 66.0 66.0 0.0 0.0 0.0 * 1 0.200 169.0 -0.6 8.0 631.86 S1.0 68.0 66. A 0.0 0.0 0.650 2 0.300 169.0 -0.6 16.0 635.82 51.0 76.0 66.0 0.0 0.0 0.963 3 0.360 169.0 -0.6 Z6.0 639.9T 53.0 80.0 65.0 ... 0.0 . 0.0 1.100 "" 6 0.330 169.0 -0.6 32.0 666.11 55.0 80.0 66.0 0.0 0.0 1.0/0 5 01170 169.0 6 0.230 169.0 7 0.300 169.0 8 0.270 169.0 -0.6 -0.6 -0.6 -0.6 60.0 667.29 60.0 650.86 56.0 656.86 66.0, 658.70 53.0 56.0 56.0 58.0 76.0 80.0 83.0 82.0 66.0 0.0 .66.0..__ 0.0 68.0 0.0 68.0 0.0 0.0 0.569 o.o 0.740 0.0 0.960 0.0 0.870 HONS 056038 W.G.KRUMMRICII PLANT SAUGET.1L (.2201. ID NO. 63 121 AAC oatf oct i ms start time 1:30 pm STACK SAMPLED- INCINERATOR ,,.......... ................. SOURCE OPERATION. NO. . 831 calculation ano evaluation: the isokinetic constant HO/HP FOR.This EQUIPMENT IS 13.Oil'. THE TAULE OELOW SMONSiFOR EACH ZONE.THE METER VOL. ANO THE AVG. METER TK: and press, in absolute units, from this is calculated the equivalent vol. STACK CONDITIONS and divided by TIME TO GIVE THE flow In the nozzle. Till- COMPARED WITH THE ISOKINETIC FLOW RATE CALCULATED FROM THE STACK VELOCIT1 Percentage deviation is recorded. i SAMPLE/STACK/AVG. PRESS/ AVG. TEMP/SAMPLE. VOL./SAMPLE RATE ZP.C. ZONE time VEL. METER STACK METER STACK METER STACK ACTUAL ISOKIN OtV 1 e.o 27.6 29.9 29.9 525.0 609.0 3.3 . 5.5 0.69 i.27-46.07 __2___ . 8.0. 33.8, .30.0 29.9 527.5 609.0, 4.0.....6.5 0.81 1.56-47,74 3 8.0 36.0 30.0 29.9 530.0 609.0 4.2 6.7 0.84 166-49,10 4 810 35.5 30.0 29.9 532.0 609.0 4.1 6.7 0.84 1.63-43.66 ...5 . .. 8.0.. 25.5., 2.V.9 ?9.9 531.5 609.0 - 3.2 .5.2 0.64 .1.17-45.00 6 8.0 29.6 30.0 29.9 S3I.5 609.0 3.6 5.8 0.7P 1.36-47.19 7 8.0 33.0 30.0 29.9 534.3 609.0 . 4.0 6.5 0.81 1.56-43.14 8 . 8.0 ..32.1 30.0 . 29.9 535.3 609.0 __ 3.9. ....6,2 ...0.78' 1.48-47.35 TOTAL 6410 31.7 30.0 29.9 531.1 609.0 30.2 49.0 0.77 1.46-47.S5 T AV , AV AV AV AV T T AV AV AV TOTAL SAMPLE VOL. CORRECTED FROM STACK CONDITIONS TO STD CONDITIONS* 42.5V CUBIC FT. OF WET GAS TOTAL SAMPLE VOL.. CORRECTED TO CRT STD. CONDITIONS .=_____ 30.78 CUBIC FT. HONS 054039 Facility: Monsanto Company W.G. Krummrich Plant Route 3 ' Sauget, IL 62201 Date of Inspection: January 27, 1976 Participants: i i Monsanto Paul Heisler Clarence Buckley U.S. Environmental Protection Agency ' Edwin Zylstra ' John Connell Charles Miller Background: Monsanto is the sole manufacturer of PCB in the United States. figures for the first nine months of 1975 are listed below: '. ' ! ` Aroclor- | 1016 \ i 1242 : 1254 ' Thousands of Pounds . 10350 5120 6980 Production Starting during the latter part of 1972, the only use for PCB compounds is in the manufacture of transformers and capacitors. Process: The chlorlnator is charged with, biphenyl and ferric chloride (catalyst) arid then heated. Vaporized chlorine is fed into the chlorinator. The contact time varies from 12 to 36 hours, depending on the type of Aroclor to he produced, which determines the degree of chlorination. The vapor from tne chlorinator (HC1 containing PCB) goes to the scrubber where it ts washed with liquid Aroclor, The gaseous HC1 is sent to the purification section of the plant. The crude Aroclor goes to the Blower tank, where tt ts blown with dry air for several hours. The air is scrubbed with water and vented to the atmosphere through a demister, the crude product ts sent to a storage tank, where a few tenths of IX of alkali is added to react with any remaining hydrogen chloride or ferric chloride. MOMS 054040 I -2- The method of distillation of the raw Aroclor varies depending upon the product to be produced. For types 1254, 1242, and 1221, the process is the same. Each is distilled in a vacuum still, the condensate being the finished product and the bottoms being the Montars which are sent to incineration. For Aroclor 1016, the crude aroclor Is distilled in a vacuum distillation tower. The steam from the steam jet ejectors is partially condensed; the condensate being discharged into the plant discharge sump and the vapor exhausted to atmosphere. The overhead from the distillation tower is the product 1016 and is sent to storage. The bottoms are sent through another chlorination and distillation cycle. The overhead from this still is the finished product and the bottoms are the Montars which are sent to incineration. The three possible places where PCB can escape into, the atmosphere are: vapor from jet ejectors, exhaust from the scrubber; and surface area evaporation (in general). . All aroclors are stored at 150F with a layer of nitrogen on top of the liquid. . Incineration: .. There are three points in the process that go to the incinerator: Montars, bottoms from separator sump, collection from all drip pans. In addition waste material from the users of PCB is sent to Monsanto to be destroyed. The type and concentration of these waste are unknown but it is estimated that they contain about 90S! PCB. The amount of contaminated waste disposed of for the first nine months of 1975 is listed below: ' :....................'. Thousands of Pounds Customer returns, records exists Monsanto, records exists * Total receipts Destroyed by incineration 1109 322 1431 2808 The liquid waste stream is steam atomized and fed into the fire box. The feed is incinerated at a temperature above2200F with natural gas used for combustion with 55! excess oxygen and a retention time of 2-3 seconds. The gases go through a quench pot, the exhaust of which passes through a venturi scrubber and then through a packed tower which is irrigated by the weak muriatic acid originating from the quench pot. The exhausts are vented to atmosphere through a demister and are monitored. ) HONS 054041 5?? 3 Loading and Unloading: Th majority of the PCB components and the products made using PCB are liquid and are transported In bulk or In steel drums. Bulk shipments are made in railroad tank car and tank trucks. Waste material shipped in from other locations in 55 gallon drums or tank trucks are unloaded Into a concrete pit; the material In this pit is periodically pumped to one of four 20.000 gallon incinerator waste feed tanks. The waste material that Is shipped In by rail truck is unloaded into a 500,000 gallon storage tank and Is pumped into the feed tanks when required. In the truck or railcar loading area, drainage is directed into a small concrete pit which is periodically pumped into the basins located in the manufacturing area. Relief valve lines and atmosphere vent's are routed through catch tanks or are redirected to underground settling basins. HONS 054042 ' . . . to ,MphUona'i(.ifltN i* \A *>* (U **') >!.* UNITED STATES GOVERNMENT Memorandum : Gerald f! Regan, Chief, Air Surveillance 6 date: March 5, 1976 Branch j '" FROM : Technical Advisor, Special Projects Section Air Surveillance Branch i - SUBJECT: Calculation of PCB Air Emissions from Storage and |! j Dispensing Operations at the Krurcmrlch Plant of Monsanto Potential air emissions from the storage and dispensing of PCB were calculated based on information supplied by Monsanto. The results of these calculations are: ' Storage tanks for virgin product - 597.b kg/year Product loading - 0:0184 kg/year Storage and handling waste aroclors - 0.000&6 kg/year Attachment (Calculations) R. Edwin Zylstra ii i i HONS 054043 Buy U.S. Swings Bonds Regularly on the Payroll Savings Plan Clarence Buckley of Monsanto estimated that storage and loading operations at the plant would displace the following volume of headspace gases: 1. Storage tanks 635,000 ft3 2. Loading 460,000 f13 - Calculation of emissions: From Fig. 2.2 from the Draft Mitre report the vapor pressure of Aroclor 1242 is 3 mm Hg at 100C and I0"1* at 21C. The aroclors are stored at I00*C. It may be assumed that the temp, in the tanks being loaded would be approximately 70F (21*C). From Dolton's law of partial pressure: I x " Px where Bx proportion by volume of a gas component P mix. . Px " partial pressure of gas component and P mix. absolute pressure of gas mixture. Bx - 3 - 0.0039 or 3900 ppm at 100C 1 TrT 1 To change ppm to mg/M3 use the following formula: mg/M? ppm x mol, wt. molecular /olume mol. wt. 261 molecular volume " 30.62 liters/mol. at !00*C rog/M3 - 3900 x 261 33242 30.62 Emissions from storage tanks: Emissions kg/year - Vol. of gas displaced/year x concentration of PCB Kg/yr 635000 ft3 x .0283 m3 x 33242 x 1 kg TtT 10b mg kg/year 597.4 Emissions from loading operations: Bx Px ,, in-4 , ...7 Fsnr. -755- ` K3 x 10 or -'3 ppm mg/MJ - .13 x mg/H3 HONS 0540*4 -2Emission^: K9/jr. - 460,000 x .0283 X 1.Ill X Kg/yr. - 0.0184 Emissions from handling of waste aroclors: ! Total waste material received into plant as reported by Monsanto for 9 mos. of 1975 * I,431,000 lbs. Assume that all this material is received and stored at 70*F and that it displaced an equal volume of tank headspace gas at 70F. Volume of produce " 1,431,000 lbs. x --r1e1--I.5glab--ls. . Xx 3.t..77H85s .l.iter 9*' XIMUttr. . A7t m3 The concentration would be the same as !h the loading operation that is 1.41 mg/M3. Emissions: Kg/yr. 471 m3 x 1.4 mg/M^ x rkg HONS 054045 UNITED STATES ENVIRONMENTAL PROTECTION AGENCY SUDj-CT: PCB Monitoring - Monsanto, Krummrich Plant, Sauget, DATE: f'ffB '.! !? 1078 Illinois. ' FROM: TO: Charles Miller/Ed Zylstra/John Connell, Technical Advisors, SPS I' Gerald F. Regan, Chief, Air Surveillance Branch On January 27, 1976, the SPS field team (Miller, Zylstra, Connell) performed ambient air monitoring for PCB's at the Monsanto Krummrich Plant, Sauget, Illinois. Although Monsanto presently manufactures PCB's at this facility, production of PCB's Is to be gradually phased-out. I After a brief discussion and orientation period with Monsanto officials, ASB and ILDO personnel toured the PCB manufacturing area Includlngthe Incinerator facility. The "plant" area where PCB's are manufactured Is not an enclosed structure per se. It is an open structure constructed of steel grating (floors, stairs), safety railings, a maze of piping, collection and reaction vessels, valves, etc. all of which are completely exposed to the elements. Mr. Claire Buckley of Monsanto was assigned as escort for ASB personnel. Only two locations were deemed appropriate as sampling sites for PCB's. Other possible sites were inaccessible or had recently been tested by Monsanto - ie. - the recent incinerator test results were furnished by Monsanto. These two sampling locations, the cleaning of glassware, equip ment used, sampling procedure, samples obtained, etc. is described below: Site location fl (SEG) - Steam Elector - Ground Level. This steam ejector pipe terminated Just above a grate which covered a recessed concrete trough in the floor at ground level. For collection of the samples, the SPS field team used the glass bubblers, Y-connector with reducer coupling, ll-tube, cold trap and vacuum pump. The H-frame base, end 2x4 manifold support and glass manifold were not used. Sampling was performed for a one-hour period, 1046 - 1146 hours. : Site location #2 (SET) - Steam Ejector - Top level or 2nd Level Above Ground.. These twin steam ejector pipes (somewhat of a candy-cane configuration) terminated out beyond the 2nd level safety railing. Sample collection was performed using the same equipment as at Site Location #1 and included the !H-frame base, one section of 2x4 manifold support, and one section of glass manifold. Sampling was performed for a one-hour period, 1205 - 1305 inours. . Mlhi:U70.4 (... 4.72) HONS 054046 -2 - fit The following narrattve defines the process for cleaning of the sampling glassware, the actual preparation for sampling, and handling of the samples collected in the bubbler train. , The ASB, SPS field team cleaned all PCB monitoring glassware via the following procedure: 1. Thoroughly wash all glassware with a solution of PCB free detergent. The concentration of the detergent is determined by the manufacturer's . 2. |Rinse thoroughly with tap water. 3. ' jRtnse thoroughly with distilled water, 4. Rinse thoroughly with acetone (reagent grade or better). 5. Rinse with hexane, rinse each bubbler three times with 50 ml. of hexane for each rinse and discard. 6. Wrap all small glass parts in aluminum foil and ensure proper sealing, . crimping of the foil. Seal all ball joints of the bubblers with aluminum foil (alternately, appropriate ball joint fittings - sealed on one end and thoroughly cleaned - may be clamped in place instead of using aluminum foil; the purpose of the above is to prevent contamination of the now PCB free glassware). Upon determination of a sampling site location, the sampling equipment supportive framework is set-up and all glassware bubbler box, pump, etc. are positioned. The sampling procedure is as follows: 1. Remove seals (foil or ground joints and clamps) from the bubblers. 2. - Place 300 ml. hexane into bubbler #1, shake, pour into bubbler #2, shake, pour into bubbler #3, shake, pour into a sample bottle appropriately designated as a reagent blank. This procedure is performed for both sides (A,and B) of the sampling train. HONS 054047 -3- 3.. Pour hexane, 400 ml., 200 ml., and 300 ml. Into bubblers 01, 02, and #3, respectively. 4. Connect the entire sampling system - U-tube, manifold, reducer coupling, Y-tube, U-tubes between each bubbler and the copper tee (containing hypodermic needles - one for each side), the quick disconnects between the tee and the cold trap and between the cold trap and the vacuum pump. Ensure that all ball joints are tightly clamped. Do not use any lubrtcunt/sealing compound on the ground glass ball joints. 5. (Fill the plywood box (containing 4 of the six bubblers) and'the I cold trap with crushed dry ice. 6. | Start the vacuum pump; note the time and vacuum gage reading; sample , for one-hour. . 7. At the conclusion of the one-hour sampling period, notavacuum gage reading, tightly double the rubber hose between the copper tee and the quick-disconnect thus stopping air flow, pull both disconnects apart, and release the previously clamped or kinked rubber hose; . shut off the vacuum pump. ' 8. Disconnect the Y-tube from the train. 9'*. Disconnect the bubbler U-tubes and the rubber hose - glass connection from last bubbler to the copper tee on one side of the train. . 10,. Pour the absorbing solutions from one side of the train (3-bubblers) tnto ofie sample bottle appropriately identified. All sample bottle - ' screw caps must have Teflon.liners. Absorbing solutions and rinses '. from each, side of the train must be in separate sample bottles - 1 bottle per side of train, 11, ' Introduce approximately 50 ml, of hexane into bubbler 01 j shake, pour into bubbler #2, shake, pour into bubbler 03, shake, and pour into the appropriate sample bottle from Step 10 above. Repeat this with another 50 ml. portion of hexane. Repeat for the second or other side of the sampling train. HONS 054048 4 ft -.4 12. Introduce 300 ml hexane Into bubbler II, shake, pour Into bubbler 12, shake, pour Into bubbler 13, shake, and pour Into another appropriately Identified sample bottle. This Is also a reagent hlanh.. Repeat for the other side of the train. 13. The bubblers can now be properly filled with the designated amounts of hexane (400 ml., 200 ml., 300 ml.) for the next sampling period. If additional sampling Is not required, the equipment (glassware) must be wrapped/sealed as defined tn Step 16 of the cleaning procedure. Ocj Ttmm tollgren Torrez Zylstra Connell HONS 054049 The table below defines the various samples collected at the Monsanto PC9 manufacturing facility: DATE 1/27/76 1/27/76 1/27/76 1/27/76 1/27/76 ,1/27/76 1/27/76 1/27/76 1/27/76 1/27/76 1/27/76 1/27/76 LOCATION Reagent Blank, Pre (SEG) Reagent Blank, Pre (SEG) Sample (SEG) Sample (SEG) Reagent Blank, Pre (SET) Reagent Blank, Pre (SET) Sample (SET) Sample (SET) Reagent Blank, After (SEG) Sample Reagent Blank, After (SEG) Sample Reagent Blank, After (SET) Sample Reagent Blank, After (SET) Sample ASB DESIGNATION 3A-T27-1 3B-T27-2 3A-T27-3 3B-T27-4 3A-T27-5 3B-T27-6 3A-T27-7 3B-T27-6 3A-T27-9 3B-T27-10 3A-T27-11 38-T27-12 LAB. NO. 76-13656 76-13657 76-13658 76-13659 76-13660 .76-13661 76-13662 76-13663 76-13664 76-13665 76-13666 76-13667 HONS **05 S/ts le>#r/isy ***/ &) HONS 054051 HONS 054052 u.'S. environmental protection ackkcv RCCXOM .V, CENTRAL ItECION'AI. LABORATORY 3l01'3 w. persuing road. cbicago, Illinois cor.oo j Data DATA TRANSMITTAL SLIP Feb. 26, 1976 TO: Chief, Air Surveillanco Branch Surv;. 6 Anal. Division DATA IDENTIFICATION Data - Sample Numbers 136S2--13667 REMARKS FEB 2 7 1976 AIR SURVEILLANCE BRANCH EPA, REGION V FROM T^ ^ MP. i_____________ FDATA COORKDINA:TOR, CENTRAL REGIONAL LABORATORY J RONS 054053 . * x- c ^ * -E11V1RQtIHEHTAL FRACTION AGENCY, REGION V BASIC DATA FORM '<*A **"**?&*, ,^-sr-^ _ Sinpljrajite T/5y HonCD Tear analysts Oajr KonUi Tear 24 of 23 1- v' ',;< v:s:er rrrf!->.'Tt pir W^fffx^rcat3^stnraas-4ef -Mlograw - -- - "a.'.-oo 39504 39508 C?.L Si"rle Ic; x-t*r ..." S?i(-nt - y&. vcStic: A?tW 2A \-- --T /y //" 7- D Aroclor 12<8 39503 Aroc+or i!5* Aroclor 1260 39511 * no ii/l<Ubi 26 7i TOi 'j t- ?A f- 7 IjA S' ' 7. if V`/V7 * 26' 2Z2/ 11 ll. LM 1 M $A / ^--Z--s-r-s-US r^r 1 YW 2/7 r4^/ > //>3 i ---7i ^' i 'ifj 6S^ ' c. /tf/.iTf Uztdpz. vM 74 I==---- /t.8 i> 7i/i ~JS* sN 74 UJW 7.7 3. -2) fi~Osr -V y 7?-Y X/T 1121 1 ......... !.. ____ 'U"s-- /JfO/Ji /j i'/D- -. S/fC/6-a -- - ____ 'I '0/S 3 vfeAees* r- rjt./f'vA fae-s A/* 't ' C/t-</?J's d-rw/* ' - S/i/#S* >7sfst rjirtra \ `AotfA*A / u/so - 1 / - / t " tffrfa-r. Aisf't'/c //To S'r. > zn Jr&t 7 i<- T*s* l<rs / t * a " Gsi/uv SVCtf/tt 7jrec.10 'f - res'ce / ' // ' <. /ir/tT *4o> * i&/Sr /?*td r tfi'/f* I -< 7/(t t/SsA / t- 9SC 11 r, *t ft /?* A*-rr* "/ *r 7fA*l f (/ Teero/?-. tt * i eve u / // O S, // 1 rJA-sc / is/t/t/C . V9o* M0NS 054054 VJ' -- ___ - t! * }/.. ' i: Monsanto-Sauget, Illinois Sampling Location Site #1 Steam Ejector-Ground Level (SEC) Site 2 Stean Ejector-Top Level-(SET) Sample No. Critical Orifice Flowrate nVhour Reagent Blank Values Before & After Each Sample ug/sanple Average Reagent Blank Values ug/sanple Sample Values ug/sample DifferenceSample Minus Ave. Blank Value Final Value ug/m3 76-13658 3A-0.71402 76-13659 3B-0.63602 7.0 / 16.8 4.7 / 3-3 11.9 4.0 . 31.5 25.0 19-6 21.6 27.5 33.9 76-13662 3A-0.71602 N.A. / N.A. 76-13663 3B-0.636C2 12.1 / 8.4 10.3 72.5 N.A. HONS 05405* ' Monsanto Interpretation of the data chart:Column 1- Sampling Location - corresponds to the preceding narrative defining sampling sites. Column 2- Sample Numbers - assigned by ASB and for use by the ana lytical laboratory. Column 3- Critical Orifice Flowrate (m3/hour) - calibrated flowrate of the critical orifice utilised on each side of the sampling train. Column 4- Reagent Blank Values - Before and After Each Sample (ug/ sample_ - defines the analytical results determined for each reagent blank. Column 5- Average Reagent Blank Values - simply the average of the two values in the preceding column. Column 6- Sample Values (ug/sample) - analytical results of the samples submitted. Column 7- Difference - Sample Value Minus Average Blank Value - defines a value representing only the sample. Column 8- Final Value (ug/m3) - defines the final or actual value of PCB's obtained at the particular sampling location; determined by divid ing the true sampling air flowrate into the corrected value (Column 7). MOMS 054056 ' Honsanto Comments: ' It Is unfortunate that Reagent Blank Values (before and after sampling) arc not available for all such samples that were submitted for analysis. Additionally, the loss of one sample (76--13663) occurred as a result of a manufacturing defect (stress/strain) in the particular sample bottle. At this point in time, the only meaningful conclusion that can be made Is that the manufacturer of PCBs has and maintains significantly Superior control of atmospheric emissions during PCB manufacture than does the user or consumer who utilizes PCBs in the manufacture of a PCB containing product. However, the amount of PCBs released is still significant and should be greatly reduced by more stringent controls. However, at this point in time, Honsanto has publicly declared that PCB manufacture will be gradually reduced and eventually phased out. Ip comparing the data for the Sauget and Bloomington monitoring efforts, It Is noteworthy that the accord or agreement between the Sauget reagent blanks and sample values (at the same site) is much improved even though the basic equipment-absorbing solution, sampling and analytical procedures, and length of sampling period were identical. HONS 054057