Document 2JOvDrxjDQoZe98LO2nNV5p7L

CC ST0000704 Harold Eosscher, Manager Midland Division 47 Building SUMMARY ON ASBESTOS IN THE MIDLAND DIVISION Since the recognition of health hazards associated with the use of asbestos, the following steps have been taken. Environmental Health conducted ?. study of pipe covcrers on the job and determined the exposure to dusts from insulating materials in use. By determining how long and hovr often the various activities wore performed a time-weighted exposure was established. From this information, the' minimal respiratory protection was established for each type of insulating material anc each activity in the pipe eoverers job. During August, 1969 the results of this study were presented to the pip covcrers, maintenance supervisors and production representatives. Additionally, the Medical Department explained the health hazards involved and the effects of smoking as a habit which enhances the chances of developing cancer of the lung. The maintenance group explained what would be required for respiratory protection and when it was to be worn. The use of fiberglass as a replacement for aircell was discussed. Since August, 19&9* the use of aircell has been discontinued and replaced with fiberglass (100``? - 350CF), Carey temp 1500 has been introduced as the replacement for calcium silicate type .insulations up to lbOCf'F. Purchasing v.'ill not buy an insulation containing asbestos without notifying the Maintenance Technology Center and insuring, that there is no other material that will do the job. Careytemp is more difficult to work with and install than some of the calcium silicate insulations. Because of this, there is probably a 9 to 10;' extra cost in using Carey temp. As the" covcrcrs become more experienced with Careytemp, this should drop. Work is underway with the manufacturer to improve the 'product. Present technology docs not give us a :a;b:vki tute for asbestos at high temperatures ). Ceramic foam " may effor a possibility for high temperature use. Insulating cements are also a problem urea. Until substitutes can be dove loped, careful handling procedures must be followed during the mixing. The introduction of additional ashes to:; containing insulation into the Division has boon vastly reduced. In the coming years, the prime .source of asbestos exposure will be the removal, transportation and disposal of old asbestos insulation. Procedures for-handling and sending old insulation to disposal must be developed. The other major use of asbestos is the chlorine cell maintenance area in the manufacture ' dUreh rarms for chlorine colls. The asbestos is re* ved in 50 lb bags and dumped into a mix tank. About 1150s lbs3 is rnoul red for a diaphragm, for the present cells and '-50 - 500 lbs will be required par dianh rages In the new plant. The new plant will use about 50,000 3bs/yr' of asbestos for this purpose. ST0000705 The operation has been studied by Environmental Health and the proper respiratory equipment ha been specified for the mixing operation. In the old cell maintenance a__r_e_s only full bags of asbestos .....r..c.....h..a..nd.led and use of partial bags is avoided which reduces expeosurc. The mixing is an intermittent operation which also reduces personnel exposure. The new plant will h:xve a comp]etc ventilation system above the mix tank v:hi e h will go to a filter unit and then to a scrubber or beag filter. In the cell buildings asbestos is handled in small amounts by the operators. It is dumped directly into the cell to plug holes in the diaphragm. This operation requires respiratory protection, for the long tom solution, a new material of construction for diaphragms is being Considered but a likely successor has not yet been found. In the cell maintenance area as the old diaphragms arc washed with high pressure viator, of the asbestos is recovered on a set of vibrating screens and is; cent to land fill. The remainder is recovered at the treatment plant on the centrifuges. Environmental Health is making a complete inventory of uses of asbestos and recommended disposal techniques. The Maintenance Technology Center will viork with Waste Disposal and Environmental Health to develop procedures for handling and disposal of covering,. , /I n<y.-ijA-- Vf. A. Snodgrass Maintcnancc Technology Center Oj^l Building rwh