Document 2J95VmX63kK1MkeqE289VDEVp

*t '" . -' 1. Detailed below is a complete tabulation of the data from the subject program. Although the survey ended April 28, 1972, all the data was not reported until May 15, 1972. 2. It is significant to note that only 1 of 520 samples (or 0.19 of the total) exceeded the temporary tolerance of 2.5 ppm (fat basis) established for PCB's. 3. Total Samples Requested Total Samples Received % Total Samples Received Milk Samples Containing PCB's1' % Mllie Samples Containing PCB's 515 520 , 101.0 27 5.2 A breakdown of the sample results by bottling or manufacturing milk is as follows: Bottling Milk Samples Requested Bottling Milk Samples Received % Bottling Milk Samples Received Bottling Milk Samples Containing PCB's % Bottling'Milk Samples Containing PCB's Range of PCB Findings - Trace to 2.8 ppm Sample Results (fat basis) PCB No. Samples Levels 3T 1 T(0.49 ppm) 1 0.2 ppm 3 0.4 ppm 2 0.5 ppm 1 0.6 ppm 1 0.7 PPm 1 0.8 ppm 369 360 97.6 21 5.8 Aroclor 1254" 1254 1254 1254 1242, 1254 1254 1254 1254 MONS 044171 oo Page 2-R. e. Duggan * No. Samples - ~2 1 2 1 1 1 -sr* PCB Levels 1.0 ppm 1.4 ppm 1.49 ppm 1.6 ppm 1.9 ppm 2.8 ppm Aroclor ""I554- 1254 1254 1254 1254 1254 Manufacturing Milk Samples Requested Manufacturing Milk Samples Received Manufacturing Milk Samples Received Manufacturing Milk Samples Containing PCB's % Manufacturing Milk Samples Containing PCB's Range of PCB Findings - Trace to 1.8 Sample Results (fat basis) 146 160 109.6 6 3.8 No. Samples PCB Levels Aroclor 1 T(0.49 ppm) 1254 1 0.5 ppm 1254 1 0.7 ppm 1254 1 0.9 ppm 1254 1 1.3 ppm 1254 1 1.8 ppm 1254 The distribution of PCB's follows: milk by FDA District is as District No. Samples Containing PCB BUP 1 BOS 1 DET 2 PHI 2 SKA 16 ~TT "IBo 3.7 3.7 7.4 7.4 59-3 iuu.0 , 41 HONS 044172 oo rage 3-R.S. Duggan 4. C. F. Jelinek, Ph.D., Program Manager, Industrial Chemicals and Heavy Metals, reports that there is a question of the validity of the reported findings down to the levels given. Since the directive for the survey specifies methodology in which "the limit of detection for PCB residues in milk fat is approximately 1.5 PP (as Aroelor 1254) when using a 3 mg. sample injection and EC-QLC operated at the above conditions." He states that if some of the analysts used a large sample size, the lower values reported would have more validity, but this could only be determined by a more detailed examination of all the data. He also Indicates that the findings of Seattle District merit further investigation. Seattle reported PCB's in 16 (or 7S%) of 21 samples examined. On the other hand, the other Districts reported PCB's in only 11 (or 2.2j<) of the 499 samples examined. Either Seattle has a very wide spread problem of PCB contamination of milk which should be looked into, or their reported findings need some other explanation. 5. A copy of the Compliance Program, Survey: Polychlorinated Biphenyls in Milk is enclosed for your review. 6. If we can be of any further assistance, please let us know. Enalosure cc: CC-4 (Vessel) BP-420 (Jellnek) BP-300 RF BP-320 RF BF-323 (FT,DDT) DDTolen: vem 5/16/72 Virgil 0. Wodlcka MONS 044173