Document 2J6Z6J0J5J4ZxbROjw73eGJ6R
Region 6 - Enforcement & Compliance Assurance Division
INSPECTION REPORT
Inspection Date(s): Media Program: Regulatory Program(s)
02/09/2023 Water Clean Water Act-National Pollution Discharge Elimination System (Brine)
Company Name: Facility Name: Facility Physical Location:
(city, state, zip code) Mailing address:
(city, state, zip code) County/Parish: Facility Phone Number Facility Contact:
Calgary Energy, LLC
Tidal Osage
Latitude: 36.541029, Longitude: -96.418515
Hominy, OK, 74035
4444 E. 146th St. N
Skiatook, OK, 74070
Tulsa
918-798-4510
Blaine Haag
Co-Owner
bhaag.calgaryenergyllc@gmail.com
FRS Number: Identification/Permit Number: Media Identifier Number: NAICS: SIC:
n/a OKU000893 n/a 211111 1311
Personnel participating in inspection:
Matthew Allen
EPA/Region 6 ECDW
Inspector
EPA Lead Inspector Signature/Date
Supervisor Signature/Date
MATTHEW ALLEN Date: 2023.02.13 16:28:56 -06'00' Digitally signed by MATTHEW ALLEN
Matthew Allen
DAMON
MCELROY
Digitally signed by DAMON MCELROY DN: c=US, o=U.S. Government, ou=Environmental Protection Agency, cn=DAMON MCELROY, 0.9.2342.19200300.100.1.1=68001003655653 Date: 2023.02.14 06:56:47 -06'00'
Damon McElroy (acting)
Date Date
6ENFORM-019-R8.2 (02/12/2020)
1
Section I - INTRODUCTION
Calgary Energy, LLC / Tidal Osage Lease CWA Inspection Date 02/09/2023
PURPOSE OF THE INSPECTION
EPA Region 6 Inspector, Matthew Allen, arrived at the Calgary Energy, LLC / Tidal Osage Lease (EPA ID No. OKU000893) at 12:30 PM on 02/09/2023 for a follow-up inspection. This was an EPA follow-up inspection in response to a National Response Center Spill Report (NRC No. 1357149) which was received by EPA Region 6. The initial spill inspection was conducted by EPA on 01/09/2023 with followup inspections being conducted 01/13/2023 and 02/07/2023. The purpose of the follow-up inspection was to observe any progress which may have been achieved by Calgary Energy, LLC in reducing pollution impacts to waters along the impacted tributary. The inspection was conducted by the authority of the Clean Water Act (CWA) to determine compliance with Environmental Protection Agency (EPA) regulations. There was no other federal, state, or local agency representative present at the time of the inspection.
FACILITY DESCRIPTION
EPA conducted a follow-up inspection at the Calgary Energy, LLC, Tidal Osage Lease where a 4-inch diameter steel/chrome injection line failed, releasing produced saltwater to the land, the spilled saltwater ultimately flowed South into a nearby unnamed tributary of Little Hominy Creek. The NRC Spill Report stated approximately 175 barrels of saltwater was released. The injection line was connected to two separate saltwater pumps in addition to multiple saltwater injection wells.
Section II - OBSERVATIONS
I observed and elevated TDS field reading of 16,411 mg/L (GPS 36.538443, -96.415800) in the main channel of the impacted tributary of Little Hominy Creek, this field reading is documented in Photo No. 1 of Appendix 1 (Photo Log). This was the highest observed TDS field reading of the inspection.
Continuing downstream, I observed an elevated TDS field reading of 5,298 mg/L (GPS 36.538199, 96.415087) in the main channel of the impacted tributary. See photo No. 2.
I observed and elevated TDS field reading of 4,691 mg/L (GPS 36.537469, -96.414301) along the impacted tributary. See photo No. 3.
At the lowermost temporary containment dam, I observed a TDS field reading of 1,875 mg/L (GPS 36.537254, -96.413136) in the unnamed tributary. This represented the lowest observed TDS field reading of the inspection. See photo No. 4.
I observed 4 men conducting cleanup activities, including pumping water from the impacted tributary, and hauling water from the location in a vacuum truck.
2
Calgary Energy, LLC / Tidal Osage Lease CWA Inspection Date 02/09/2023
TDS field readings observed during the inspection were taken with a properly calibrated YSI Pro 30 conductivity meter. Section III - AREAS OF CONCERN Calgary Energy, LLC should ensure an appropriate amount of manpower is maintained daily along the impacted area. Calgary Energy, LLC should continue removing elevated TDS waters from the impacted tributary. The flowpath from the release point to the point of entry should be cleaned. Cleanup activities should continue until background TDS readings are observed along the impacted tributary. Section IV - FOLLOW UP EPA Inspector received no additional information related to spill cleanup after exiting the location on 02/09/2023. EPA Inspector will continue follow-up phone calls and additional site visits until the impacted tributary is restored to background TDS levels. Section V - LIST OF APPENDICES Appendix 1 - Photo Log - 4 photos taken 02/09/2023
3
Calgary Energy, LLC/ Tidal Osage Lease (CWA) Inspection Date: 02/09/2023
Appendix 1 Photograph Log
4 Photos
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY
Photograph Log
Location: 36.541029, -96.418515 City: Hominy
Photo No. 1 County/Parish: Osage
State: Oklahoma
Photo File Name: R0010055 Orientation: NW Date of Photo: 02/09/2023 Time of Photo: 12:39 PM Latitude: 36.538443 Longitude: -96.415800 Photographer: Matthew Allen Description: This was an elevated TDS field reading of 16,411 mg/L taken in the main channel of the impacted unnamed tributary of Little Homing Creek.
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY
Photograph Log
Location: 36.541029, -96.418515 City: Hominy
Photo No. 2 County/Parish: Osage
State: Oklahoma
Photo File Name: R0010056 Orientation: E Date of Photo: 02/09/2023 Time of Photo: 12:43 PM Latitude: 36.538199 Longitude: -96.415087 Photographer: Matthew Allen Description: This was an elevated TDS field reading of 5,298 mg/L taken in the main channel of the impacted tributary.
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY
Photograph Log
Location: 36.541029, -96.418515 City: Hominy
Photo No. 3 County/Parish: Osage
State: Oklahoma
Photo File Name: R0010057 Orientation: WSW Date of Photo: 02/09/2023 Time of Photo: 12:47 PM Latitude: 36.537469 Longitude: -96.414301 Photographer: Matthew Allen Description: This was an elevated TDS field reading of 4,691 mg/L taken in the main channel of the impacted tributary.
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY
Photograph Log
Location: 36.541029, -96.418515 City: Hominy
Photo No. 4 County/Parish: Osage
State: Oklahoma
Photo File Name: R0010058 Orientation: SE Date of Photo: 02/09/2023 Time of Photo: 12:52 PM Latitude: 36.537254 Longitude: -96.413136 Photographer: Matthew Allen Description: This was a TDS field reading of 1,875 mg/L taken at the lower containment dam which had been placed by the operator to prevent further downstream migration of impacted waters.