Document 2Eopk1kk5ZJaqKxe9qdD2vJL

ABD00313328 VINYL 1985 SAFETY PROGRAM I. Monthly Safety Meetings A. Have two meetings dedicated to writing and discussing Job Safety Analysis. B. Have one meeting discussing home safety and home emergency preparedness. C. Have the Safety Department give the required annual respirator training to provide shift-to-shift consistency. D. Prepare the monthly meetings so that there is more operator participation. E. Have a meeting to review the recently revised power failure procedure. II. On-Shift Meetings A. Develop the use of short on-shift meetings to discuss recent safety problems, operational problems and review new or existing procedures. B. These meetings would also be used to get operator feedback on developing operational problems. III. Training Needed A. Train the "A" operators to assist in permit procedures by learning to clear equipment and prepare for maintenance. B. Have a training session for the Shift Supervisors and Chief Operators on the VCM tank farm. This would cover the railcar unloading operation and environmental/safety systems at the tank farm. A* ABD00313329 VINYL SAFETY REVIEW 1) 1984 REVIEW a) INJURIES b) VCM EXPOSURE 2) 1985 DEPARTMENT GOALS 3) YARD SUPPORT 4) 1985 SAFETY PROGRAM A ABD00313330 VINYL INJURIES Lee Childers - 12/22/84 - OSHA - bruised/fractured heel and strained knee fell off ladder while trying to open valve. Mike Nathan - 7/9/84 - OSHA - cut finger on insulation band - not wearing gloves. Milton Threadgill - 7/8/84 - FA - got a bug in his eye. Sammie Stokes - 8/2/84 - FA - Skinned his knee - Climbed up on the old unit dump box to open a valve. DATE 84/01 NAME Reactor Operator Reactor Operator Lead Operator ABD00313331 VINYL VCM EXPOSURE EXPOSURE 1.2 ppm-- respirator 1,4 ppm- respirator 1.5ppm- no respirator 84/02 84/03 84/04 84/05 Shift Supervisor Chief Operator Chief Operator Reactor Operator Reactor Operator Reactor Operator Reactor Operator Chief Operator Reactor Operator Reactor Operator Reactor Operator 2.4ppm- respirator 29.1 ppm - respirator 454 ppm- respirator 3.7 ppm- no respirator 3.8 ppm- no respirator 1.4 ppm- respirator 145.6 ppm- respirator 16 ppm-- no respirator 1.8 ppm- respirator 6 ppm- no respirator 3.7 ppm- no respirator 84/06 Utility Yard Operator Chief Operator Lead Operator Reactor Operator 10.7 ppm - respirator 2.5 ppm- respirator 3.7 ppm- respirator 4.8 ppm- respirator 3.9 ppm- respirator SOURCE Changing VCM filters in old unit. Conducting a VCM leak check in old unit. Worked in control room when pressurization was not working. Checking VCM filter packs in both units. Helping change VCM filter pack. Helping control emergency VCM release at tank farm. Routine duties. No specific cause identified. Routine duties. No specific cause identified. Checking for leaks in the old unit. Changing VCM filter packs. Disconnecting and unplugging lip seal line on D300. Changing VCM filter pack. Routine duties. No specific cause found. Painted handrails at incinerator and helped label breakers in VI1 dryers. No cause found. Monitoring blend tank level during pond resin pump up. Helped mechanics work on Corkens at tank farm. Blocking in VCM pump with blown seal. Pumping pond resin. Changing VCM filter packs. Page 1 DATE 84/08 84/09 84/10 84/11 84/12 NAME Lead Operator Yard Operator Chief Operator Reactor Operator Reactor Operator Reactor Operator Utility Yard Operator Lead Operator Yard Operator Yard Operator Reactor Operator Reactor Operator Reactor Operator Yard Operator Reactor Operator Yard Operator Reactor Operator ABD00313332 VINYL VCM EXPOSURE EXPOSURE 1.3 ppm- no respirator 1.7 ppitr respirator 1.2 ppm- respirator 10.1 ppm- no respirator 1.4 ppm- respirator 2.9 ppm- no respirator 1.1 ppm- no respirator 2.6 ppm- respirator 2.2 ppm- no respirator 1.3 ppm- respirator 1.3 ppm- respirator 23.5 ppm- respirator 2.6 ppm- respirator 16.1 ppm- respirator 4.6 ppm- respirator 1.9 ppm- respirator 2 ppm- respirator 1.7 ppm- respirator SOURCE Spent entire shift in control room. No cause found. Hooking/unhooking VCM rail cars and working on Corken compressors. Changind VCM filter pack. Doing routine job. No cause found. Sampling 745 reactor. Training another operator in old unit. No specific cause found. Training in old unit. No specific cause found. Hooking/unhooking VCM railcars. Working in vicinity of a VCM filter pack being changed. Hooking/unhooking VCM railcars. Hooking/unhooking VCM railcars. Changing VCM filter packs. Rinsing out Chem Wash tank. Changing VCM filter pack. Hooking/unhooking VCM railcars. Washing out Chem Wash tank. Unloading VCM railcars. Looking for leaks in the new unit. Page 2