Edward J. Abrams Director-Research & Development Hardman Incorporated 600 Cortlandt Street Belleville, NJ 07109 Dear Mr. Abrams:
In response to your letter of July 7, the D.O.T. classification for "Calidria" asbestos RG-144 is "Asbestos ORM-C." It has no flashpoint as asbestos is inflammable.
We have responded to your letter of April 2, a copy of which is attached. We have no record of having received your letter of April 18. Please send a copy to my attention if additional information is required.
Very truly yours,
Gordon L. Dickson Technical Sales Representative Eastern Region
GLD:dal Attachment CC: Ms. Lesley Baker
1). Trade Name
"Calidria" asbestos RG-144
2) . Chemical Name Chrysotile asbestos
3) . Boiling Point NA
4). CAS Number
1332-21-4
5)'. Amine Value
NA
6) . Composition------------- b
s.._______________
7) . DOT Hazard Classification 0RM-C
8) . DOT Proper Shipping Name asbestos
9) . Equivalent Weight1
10) . Flash PointNA
11) . Mohs HardnessNA
______________________________
13) . Molecular Weight554.27
?
21) . SPl Classification
22) . Supplier Bouffard Associates, 179 Post Rd. West, Westport, CT 06880
23) . Telephone
203/227-7971
24) . Acidity % HCL_____ NA_____________________________
25) . Vapor Pressure NA
2 6) . ViscosityNA________________ _____________
27) . Water %= 2% (typical property)
28) . Weight/Gallon NA
Company Name:
Union Carbide Corporation
Metals Division P. 0. Box 579 Niagara Falls, NY 14302
Z- j)u4<
Gordon Y'. Dickson
Technical Sales Rep Eastern Region
716/278-3371
w t to* *Y W
/
B. L. Ingalls^
Niagara Falls - File
^4 If 4
(/ duilIETil@[J?SSSTOS
UNION CARBIDE CORPORATION MINING & METALS DIVISION
P.0. BOX 579
NIAGARA FALLS, N.Y. 14302 TEL: 716-285-3311
December 14, 1971
Mr. E. Abrams Hardman Incorporated 600 Cortlandt Street Belleville, New Jersey 07109 Dear Mr. Abrams:
Enclosed is the completed hazardous data sheet on 144 as per your request via Mr. Mike Kovach.
Should you have any questions or if you should need any further assistance, please do not hesitate to contact us.
Very truly yours,
B. L. Ingalls Manager - Eastern Region Sales and Technical Service
BLIrcjb Enel.
p g\ r~r\ n a r\ p
Uj
Aii \J INCORPORATED
BELLEVILLE, NEW JERSEY 07109
(201) 751-3000
SUPPLIER
Union Carbide Corp. Plastics l)iv. 935 Allwood Rd.
Clifton, N. J. 07012
PRODUCT Resin Grade 144
HAZARDOUS CLASSIFICATION
Effect on Skin
(Table 1)
Ingestion
(Table 3)
Inhalation
(Table 3)
Percutaneous Absorption (Table 3)
Effect on Eyes
(Table 3)
Flash Point
(Table 5)
Pressure Generating
(Table 5)
Other
SPI -
------ LDso LC50
_LD o Foreign body, as J with any dust
"
Threshold Limit Value 5 fibers > 5 mi cron/ml
OTHER
None Unknown Chronic toxicity equc
Ifl_-asb&s.t ps_ .i nsen e re
None
-
(Estimate if not on current list of ACGIH*)
H. CHEMICAL AND PHYSICAL PROPERTIES
Test Method
Flash Point
~ C. ______________________
Vapor Pressure ______ tnra Hg
Fire Point
"
Auto Ignition
C. C.
ph/Concentration 9.0-9.5 in 4$o aqueous slurry
Under what conditions does material decompose and what are decomposition products?
Thermal decomposition - converts to Forsterite at 750"c anamorphous, non-toxic mineral
List by chemical name and percentage any component of formula which may have
toxic, irritant, flammable or explosive properties: $ge attached
Compound
Approx. %
Toxic
Irritant
Flammable
Explosive
III. STORAGE AND HANDLING
Not below
F.
Not above
F.
Fire Extinguisher ( S)
ABC
CQ2 ________ Other:
In case of container breakage or leakage Avoid br63thing dust ~ remove immediately
I.C.C. regulations on transporting and labelling
Red Label ( * ) ____ Yes _X___ No
Explosive Limits ~ % To ~ % By volume in air
IV. FIRST AID AND PERSONAL SAFETY
Recommended, pre-placement or periodic medical examination (health standard,
clinical test, frequency, etc.) N0rmai pre-placement examination including Xray
Recommended personal protective equipment is Local-exhaust Ventilation to control dust. Respirators if dust control cannot be provide?! Respirators with filter adequate tor asbestos dust.___________________________ _____ !
Antidote and First Aid
Skin Contact
Treat as foreign body as with any dust.
Inhalation Ingestion
Not applicable Not applicable____________________________________________
V. INFORMATION FURNISHED BY
Name B. L. Ingalls_________ _____________ Manager - Eastern Region
Title Sales & Technical Service Mining & Metals Division
Company Union Carbide Corporation
P. '"0"." "Box "579--------------------------
Address Niagara Falls, New York 14302
Date December 14, 1971
Telephone (716 ) 285-3311 Ext. 6661
Area Code
TABLE I TYPICAL CH v..?. r^n11L ANALYSES
Comoonent
MgO Si O? AI2O3 Fe (Total) Fef, as FeO
Fe3+, as Fe?03
L.O.I. at 1000C (water + C02) C as CO? Ni as Mi0 Ba
Total
Product dried at 105C
RG-144
45.25 41.10
0.30 (1.69) 0.81 1.51 13.53 (0.50)
0.20 <0.01
99.70
Analysis*, %
TABLE II
TYPICAL RESULTS CF SPECTR9GR.-PHIC ANALYSIS
Element Detected
Estimated Amount, . RG-144
A1 0.08-0.8 Ca 0.02-0.2 Co 0.008-0.08 Cr 0.08-0.8 Cu Fe 0.2-2
Mg Major Mn 0.02-0.2 Na a
Ni . 0.1-1 Si Major
Ti 0.02-0.2 V 0.001-0.01