Document 299O2vbaY8dLjx351OymY06p

INDUSTRIAL HYGIENE SUMMARY - 1982 - BY J. L. MOREAU, JR. RAILROAD-TANK CAR CLEANING CHEMICAL EXPOSURE RESULTS . NOISE SURVEYS ............................. ACCOMPLISHMENTS ........................ GOALS FOR 1983 ........................ PAGE 1-2 3-11 12 13 MARINE CHEMICAL EXPOSURE RESULTS - BARGES (OTHER THAN BENZENE) ................... 1-2 CHEMICAL EXPOSURE RESULTS - BENZENE BARGES ............................................... 3-4 VINYL CHLORIDE SHIP DISCONNECT EXPOSURE RESULTS ..................................... 5-7 ACCOMPLISHMENTS ................................................................................................................. 8 GOALS FOR 1983 9 ANNUAL REVIEW FEBRUARY 9, 1983 RAILROAD-TANK CAR CLEANING MARINE INDUSTRIAL HYGIENE MEDICAL Oo CQh/p- ID?nT8t98L. DOW CHEMICAL U.S.A JANUARY 6, 1983 LOUISIANA DIVISION P. O. SOX ISO PLAQUE MINE. LOUISIANA 70764-0160 604 389*8000 P. J. PREJEAN SHIFT SUPERVISORS 0. C. DICKERSON BULLETIN BOARD J. M. CRONAN BULLETIN BOARD DANNIE KENNEDY RAILROAD RAILROAD RAILROAD RAILROAD TANK CAR CLEANING/INSPECTION TANK CAR CLEANING INDUSTRIAL HYGIENE FOR YOUR INFORMATION, FOLLOWING ARE PERSONNEL EXPOSURE LEVELS, SHOWN IN PARTS PER MILLION, FROM TANK CAR SAMPLES TAKEN IN 1982 DURING CLEANING OPERATIONS. TLV'S LISTED ARE MAXIMUM ALLOWABLE EXPOSURES. SAMPLES WERE TAKEN WITH PERSONNEL MONITORING PUMPS. J. L. MOREAU, JR. INDUSTRIAL HYGIENE RAILROAD/MARINE AN OPERATINO UNIT OF THE DOW CHEMICAL COMPANY -1- Do 080790 conf 7^NrXAL A. HYLENE CHLORIDE TLV-100 0.13 0.11 7.04 10.03 10.97 13.34 8 HOUR TIME WEIGHTED AVERAGES CARBON TETRACHLORIDE TLV-5 0.47 0.32 0.11 0.11 0.09 0.12 0.22 0.20 16.31 9.28 CHLOROFORM TLV-10 0.29 0.08 7.07 8.17 0.38 0.01 9.43 6.71 PERCHLOROETHYLENE TLV-50 1.81 4.72 0.07 0.10 0.56 10.22 METHYL CHLORIDE TLV-50 0.65 0.63 0.14 0.08 0.05 0.05 ETHYLENE OXIDE TLV-3 0.11 0.12 0.20 0.20 1.16 1.12 METHYLENE CHLORIDE TLV-500 213.63 223.82 386.72 15 MINUTE EXCURSIONS (SHORT TERM SAMPLES) CARBON TETRACHLORIDE TLV-20 2.98 4.46 1.04 0.33 0.09 PERCHLOROETHYLENE TLV-150 (200) 17.96 21.74 30.03 18.38 6.57 VINYL CHLORIDE TLV-5 0.07 0.07 0.08 0.08 0.08 0.08 0.08 0.08 0.07 0.07 0.06 0.07 0.07 0.08 0.06 METHYL CHLORIDE TLV-100 0.65 0.61 0.68 0.19 ETHYLENE OXIDE TLV-50 0.86 5.17 -2- DO 080791 CONFIDENTIAL DOW CHEMICAL U.S.A. ( AUGUST 23, 1982 LOUISIANA DIVISION P. O. BOX 160 PLAaUEMINE. LOUISIANA 70764-0160 604 380-8000 J. E. CAMPBELL - IND. RELATIONS/MTLS. HANDLING P. J. PREJEAN - RAILROAD J. M. CRONAN - TANK CAR CLEANING CHARLIE HALPHEN - INDUSTRIAL HYGIENE DANNIE KENNEDY - INDUSTRIAL HYGIENE JOHN MCBRIDE - SAFETY THE ATTACHED NOISE SURVEYS WERE MADE BY MONITORING EMPLOYEES WITH BRUEL & KJAER TYPE 4431 DOSIMETERS TO DETERMINE THE EXTENT OF NOISE DURING THE NORMAL WORK DAY. 100% REPRESENTS MAXIMUM ALLOWABLE EXPOSURE, EQUIVALENT TO 85 DECIBELS (DBA) FOR A DURATION OF 8 HOURS. MUCH PROGRESS HAS BEEN MADE IN REDUCING NOISE LEVELS. MORE ATTENTION WILL BE GIVEN TO TANK CAR CLEANING WHERE INITIAL LEVELS WERE EXTREMELY HIGH. NEW METHODS ARE BEING IMPLEMENTED IN EFFORTS TO FURTHER REDUCE EMPLOYEE EXPOSURE. J. L. MOREAU, JR. INDUSTRIAL HYGIENE SPECIALIST RAILROAD/MARINE DEPTS. SG COPIES: BULLETIN BOARD - RAILROAD "" - TANK CAR CLEANING AN OPERATING UNIT OF THE DOW CHEMICAL COMPANY D0 080792 CONFIDENTIAL RAILROAD SWITCHING CREW V-.TE 6-23 It Tl tl 11 If tl It II It 11 It DOSIMETER # 839609 839611 839610 839608 839609 839611 839610 839608 839609 839611 839610 839608 NAME G. KLEINPETER L. TILLMAN D. DUGAS L. PARAULT A. HONORE K. LEBOUEF K. BERGERON 0. JACKSON K. DAIGLE L. JACKSON R. SHANKLIN 0. JACKSON JOB DURATION FIELD MAN PIN PULLER FOREMAN ENGINEER ENGINEER FIELD MAN FOREMAN PIN PULLER FOREMAN FIELD MAN ENGINEER PIN PULLER 715AM-245PM tl tl It If tl tl 300PM-1100PM tl tl II II It tl 1100PM-630AM It If It II *' 300AM % ALLOWABLE EXPOSURE 32 49 26 86 88 46 23 58 29 57 67 41 CONCLUSION: SEE SWITCH ENGINES NOISE SURVEY DATED APRIL 1, 1981 - RECOMMEND CONTINUED WEARING OF HEARING PROTECTION BY ANYONE RIDING FRONT OF ENGINE WHEN HORN IS BLOWING. t DO 0B0793 -4 I -'E 6-24 II It It II 11 1! 6-29 VI 7-21 It DOSIMETER if 839608 839609 839611 839608 839609 839608 839609 839609 839611 839608 839610 TANK CAR CLEANING NAME M. OSBORNE L. GRANT W. EDWARDS W. LAYNES ED DOMINIQUE SON TATE W. JOHNSON W. JOHNSON SON TATE W. JOHNSON SON TATE JOB DURATION LABORER II VI ft VI VI IV It Vi II It 745AM- 245PM It VI VI It 300PM- 1100PM VI VI 1100PM- 600AM IV II 300PM- 1030PM II VI 320PM- 1030PM It vt 1 ALLOWABLE EXPOSURE 30 40 20 72 609* 30 84 309** * 198**** 442*** 236***** * ** *** DRIED It It HOPPER 11 It CAR ft ft BOTTOM OUTLETS ft ft 11 ft WITH ft ft 3/4 VI ft IN. AIR HOSE VI ft VI ti ALSO DRIED INTERIORS OF 4 TANK CARS WITH AIR HOSE **** DRIED INTERIORS OF 2 TANK CARS WITH AIR HOSE ***** DRIED INTERIORS OF 4 TANK CARS WITH AIR HOSE (15 CARS) (13 CARS) (12 CARS) CONCLUSION: SEE PREVIOUS NOISE SURVEYS, RECOMMEND CONTINUED WEARING OF HEARING PROTECTION WHEN EXPOSED TO HIGH NOISE LEVELS. DO 080794 CONFIDENTIAL -5- RAILROAD TRACK MAINTENANCE { *E 7-2 II It ft 7-26 II DOSIMETER If 839608 839609 839610 839611 839608 839610 NAME L. FIELDS W. RAY W. ELZY B. WASHINGTON F. WHITE G. MELANCON JOB LABORER It tl FOREMAN LABORER 1 DURATION 730AM-300PM tl ft tl tl tl II 745AM-330PM II II * OPERATED AIR DRIVEN SPIKE DRIVER ** OPERATED TIE PULLER % ALLOWABLE EXPOSURE 72* 41 45 68** 79* 47 CONCLUSION: SEE PREVIOUS NOISE SURVEY. RECOMMEND CONTINUED WEARING OF HEARING PROTECTION WHEN OPERATING OR IN CLOSE PROXIMITY TO HIGH NOISE EQUIPMENT. DO 080795 confidential -6- RAILROAD TIE TAMPER l TE 8-13 11 8-16 8-17 DOSIMETER If 839608 839610 839608 839608 NAME K. BERGERON F. WHITE B. PICKERING P. POLITZ B. PICKERING P. POLITZ JOB IN CAB OPERATOR ON GROUND IN CAB OPERATOR ON GROUND DURATION 730AM-23OPM 11 ft 715AM-200PM 715AM-230PM Z ALLOWABLE EXPOSURE ' 104 88 83 85 CONCLUSION: SEE PREVIOUS NOISE SURVEY. RECOMMEND CONTINUED WEARING OF HEARING PROTECTION BY OPERATOR IN CAB AND ALSO BY MAN ON GROUND WHEN IN CLOSE PROXIMITY TO TAMPER WHEN TAMPER IS OPERATING. NOISE LEVELS COULD BE GREATLY REDUCED BY INSULATING INTERIOR OF TAMPER CAB AND BY INSTALLING AN AIR CONDITIONER. AT PRESENT, FOR OPERATOR COMFORT IN HOT WEATHER, IT IS NECESSARY TO KEEP CAB DOORS OPEN, THEREBY INCREASING NOISE EXPOSURE. 00 080796 CONFIDENTIAL. -7- DOW CHEMICAL U.S.A. MARCH 5, 1982 LOUISIANA DIVISION P. O. BOX ISO PLAQUEMINE. LOUISIANA 70764-01 BO B04 3B6-8000 P. J. PREJEAN - RAILROAD J. M. CRONAN - TANK CAR CLEANING CHARLIE HALPHEN - INDUSTRIAL HYGIENE DANNIE KENNEDY - INDUSTRIAL HYGIENE JOHN MCBRIDE - SAFETY ATTACHED IS A NOISE SURVEY OF THE COMPRESSOR AND PUMP AREA, UNDER ROOF AND OPEN ON 3 SIDES, ON WEST END OF BLDG, 4101. THIS IS ADJACENT TO A WORK AREA AND IS DESIGNATED AS AN AREA OF EXCESSIVE NOISE, WITH HEARING PROTECTION REQUIRED. IN ADDITION TO THE SURVEY USING A SOUND LEVEL METER TO MEASURE INTENSITY, AN OCTAVE BAND ANALYZER WAS USED TO SEPARATE AND IDENTIFY THE COMPRESSOR PROBLEM FREQUENCIES. MAINLY, THE PROBLEM WAS FOUND TO BE IN THE LOWER FREQUENCIES, WHICH SHOULD BE RECTIFIED BY THE PROPOSED BARRIER. IT IS RECOMMENDED THAT A THREE SIDED BARRIER (LEAVING SOUTH SIDE OPEN) MADE OF CONCRETE BLOCK, WITH ONE DOOR, BE CONSTRUCTED. THIS SHOULD PROVIDE A PERMANENT SOLUTION TO THIS NOISE PROBLEM. ALL SURVEY RESULTS ARE IN DECIBELS (DBA). A COST ESTIMATE FROM ENGINEERING IS INCLUDED. J. L. MOREAU, JR. INDUSTRIAL HYGIENE - RAILROAD/MARINE SG AN OPERATING UNIT OP THE DOW CHEMICAL COMPANY -8- DO 080797 CONFIDENTIAL ft ji. iasu i tSL-tsia * * t ** * fid-X fi/uo /b/nP P-X PuAM/At& (fid-2. PaaJfIb op/=) South <t 00 t- <r hz O Uj cc c c >- u. cz cc o lVm> U)iAK PUrmm \S'fPm)n U 39 93 99 94 9S 91 9S 91 9& }___________________________ SlDZbMLK JU)3/lKiA)& % 9? 9/ 92- 91 99 iXfick *H9-Paly Hopped CHdS sP*TT&>. SL dADn}&$ OAf SiDSMkluhRkjfi} meA 7f\k*J 5 FT. fiPflHT A>*T To CHAJ poftfH NOISE SURVEY AIR COMPRESSORS & PUMPS WEST END OF BLDG. 4101 2-19-82 WIND ESE - 9 MPH AC-1 (OLD) AIR COMPRESSOR - RUNNING ALONE DISTANCE 1' 3' 5' 10' 17' NORTH 92 90 88 SOUTH 94 91 90 88 85 EAST 92 90 89 85 WEST 92 90 88 2-23-82 WIND CALM AC-2 (NEW) AIR COMPRESSOR WITH PANELS OFF - RUNNING ALONE DISTANCE r 3' 5' 10' 15' NORTH 105 103 100 97 96 SOUTH 101 99 97 95 93 EAST 107 104 102 99 96 WEST 102 101 100 97 95 AC-2 RELIEF VALVE NOISE AT 31 SECOND INTERVALS (13 ON - 18 OFF) DISTANCE NORTH ALONG SIDEWALK/WORK AREA 5' 106 CORNER - EAST END - 96 CORNER - WEST END - 97 10' 102 WORK PLATFORM - 94 17' 100 (MIDDLE OF CHANGE ROOM DOOR - 88 SIDEWALK) -10- DO 0B0799 ONFTDENTI Al. C 3-5-82 AIR COMPRESSOR AC-2, CHECKED WITH OCTAVE BAND ANALYZER. ALL READINGS MEASURED 5 FT. FROM SOURCE IN ALL A DIRECTIONS. OCTAVE BAND FREQUENCY Hz 31.5 63 125 250 500 1000 2000 4000 WEST 91 81 95 92 94 91 85 80 NORTH 92 85 92 91 96 89 84 80 EAST 92 85 94 90 92 89 85 79 SOUTH 93 87 96 94 95 88 81 77 -11- DO 080000 CONFIDENTIAL ft* DO 0 8 0 8 0 1 C O N F ID E N T IA L . PLANTcgntact- PROSLEM NOISE OVERVIEW 1 t't\rbcA*u* \4UUsM-ri*t*x > jpoc^h/Cit 7- RECOMMENDATIONS sdst-dQ, ,{(f c/< d sv^&l $ d&Z [i- y`0oy ir?o 1~L 100O n&t, acR. j2ui^ u,f.c^ . L 'v s V(fG'~f-4-L^^^~(f ` l'lS"^-' US S/I'S*'-<' r`j RAILROAD - TANK CAR CLEANING ACCOMPLISHMENTS - 1982 EMPLOYEE EDUCATION PROGRAM - 100% PARTICIPATION NOISE SURVEYS WITH EMPHASIS ON PROBLEM AREAS. ZERO NON-COMPLIANCES - COMPOSITE SAMPLER MONITORS 24 HOUR DISCHARGE. 5,000 GALLON TANK TRAILER TO FACILITATE REMOVAL OF GLYCOLS FROM ISOLATED HOLDING PIT TO GLYCOL #2 FOR DISPOSAL. IMPROVED CLEANING PROCEDURE FOR VINYL CHLORIDE TANK CARS REDUCING CLEANING AND PERSONNEL EXPOSURE TIME FROM APPROXIMATELY 18 HOURS TO 10 HOURS PER CAR. ALL PERSONNEL EXPOSURE SAMPLES WERE BELOW TLV. -12- DO 08080? CONFIDENTIAL RAILROAD - TANK CAR CLEANING GOALS - 1983 PROTECTING THE PHYSICAL WELFARE OF EMPLOYEES BY REDUCING CHEMICAL AND NOISE EXPOSURES. CONTINUING EDUCATION OF EMPLOYEES - CONSEQUENCES OF OVEREXPOSURE TO CHEMICALS, SURVEY RESULTS, ETC. COMPLETION OF EXTENSIVE NOISE SURVEYS USING MUFFLERS. CONTINUING MONITORING PERSONNEL CHEMICAL EXPOSURES WITH EMPHASIS ON SUSPECT CARCINOGENS. PIPELINE TO CENTRAL WASTE TREATMENT FOR PERMANENT DISCHARGE OF ALL WASTE OR WASH WATER FROM CLEANING OF RAIL CARS. ZERO NON-COMPLIANCES IMPROVEMENTS TO OR REPLACEMENT OF CONTINUOUS ANALYZER DUE TO HIGH MAINTENANCE COSTS. -13- 00 080803 CONFIDENTIAL R DOW CHEMICAL U.S.A. January 18, 1983 LOUISIANA DIVISION P. O. BOX ISO PLAQUEMINE. LOUISIANA 70764-0160 S04 389*8000 A- R. Kirby D. R. Fabre Shift Supervisors Bulletin Board Dannie Kennedy Marine Marine Marine Dock //I Industrial Hygiene FOR YOUR INFORMATION, ATTACHED ARE PERSONNEL EXPOSURE LEVELS, SHOWN IN PARTS PER MILLION, FROM BARGE LOADING AND SHIP DISCONNECT OPERATIONS IN 1982. SAMPLES WERE TAKEN WITH PERSONNEL MONITORING PUMPS. TLV'S LISTED ARE MAXIMUM ALLOWABLE EXPOSURES. J. L. Moreau, Jr. Industrial Hygiene Railroad/Marine tt AN OPERATING UNIT OF THE DOW CHEMICAL COMPANY -1- DO 080804 CONFIDENTIAL 8 HOUR TWA - PERSONNEL SAMPLES - BARGES METHYLENE CHLORIDE TLV-100 36.11 34.78 45.16 0.12 CHLOROFORM TLV-10 0.58 1.01 6.01 5.62 5.29 4.41 12.12 11.66 33.95 18.16 PERCHLOROETHYLENE TLV-50 0.32 0.17 1.24 0.57 ETHYLENE DICHLORIDE TLV-10 0.39 8.22 10.20 8.05 0.06 2.80 0.13 0.06 12.20 0.21 0.91 4.99 0.08 5.27 CARBON TETRACHLORIDE TLV-5 1.55 0.07 0.17 0.78 0.39 0.44 0.39 0.43 DO 080805 CONFIDENTIAt DOW CHEMICAL U.S.A JUKE 22, 1982 LOUISIANA DIVISION P. O. BOX ISO PUAQUENIINE. LOUISIANA 70764-0150 604 389-8000 DR. K. J. FLANAGAN - MEDICAL TONY EKKER - MARINE AL KIRBY - MARINE CHARLIE HALPHEN - INDUSTRIAL HYGIENE DANNIE KENNEDY - INDUSTRIAL HYGIENE ATTACHED IS A BENZENE MONITORING SURVEY OF BARGE LOADING EXPOSURES SHOWING RESULTS OF BOTH PERSONNEL PPM AND URINARY PHENOLS FOR COMPARISON PURPOSES. THE DIFFERENCE BETWEEN PHENOL A.M. AND P.M. LEVELS DETERMINES EXPOSURE, WITH ANY NUMBER BELOW 16 MG BEING CONSIDERED NORMAL. A LEVEL OF 75 MG PHENOL CORRESPONDS TO AN AIR LEVEL OF 10 PPM BENZENE, WHICH IS THE OSHA STANDARD. WITH THE POSSIBLE EXCEPTION OF THE THREE HIGH PHENOLS, THESE FINDINGS INDICATE THAT EMPLOYEES ARE USING RESPIRATORS PROPERLY. J. L. MOREAU, JR. INDUSTRIAL HYGIENE - RAILROAD/MARINE SG AN OPERATING UNIT OF THE DOW CHEMICAL COMPANY -3- 00 080806 CONFIDENTIAL BENZENE BARGE PC 7506 V If 1 DC-372 1 PC-2506 tl ff ft PC-2506 II tt DC-306 II tt DC-310 It 11 DC-306 tl tt DATE 1-22-82 ft ft tl 1-28-82 ft 2-10-82 VI ft VI 3-17-82 tt VI 3-23-82 II ft 3-26-82 tl It 4-13-82 " If NAME STEVEN PREJEAN . CALVIN YOUNG EDWARD ALTAZAN FRANCIS BARLOW C. J. WOODS T. T. HAMMONDS B. W. BOLYER A. C. WILSON R. C. WATTS N. WASHINGTON CALVIN YOUNG MARTIN GEHLING FRANCIS BARLOW J. H. LEFEBVRE R. J. DUHON GARY BENSON MARK HUTSON O'NEAL BOSLEY FREDERICK JACKSON PHILIP DOIRON KEN BARTHEL HARVEY CAVALIERE S.S. NO. 437-04-4550 438-56-9003 437-02-3076 437-58-8467 438-11-9731 436-04-4137 435-84-9657 437-13-2018 439-19-5274 434-64-8694 438-56-9003 437-02-0936 437-58-8467 435-17-5371 436-76-7683 435-23-5281 433-04-8585 439-90-9452 437-90-8525 439-23-5347 437-70-9689 435-80-5906 PERSONNEL SAMPLE PPM 8.07 0.06 26.45 0.66 0.07 4.56 3.64 2.96 3.49 0.04 7.23 9.52 8.49 4.26 1.31 35.90 17.47 0.05 23.96 16.77 53.08 0.46 MG PHENOL AM-PM 2-10 NORMA] 1-5 2-8 1-1 " 1-1 " 1-1 3-4 " 1-34 HIGH 3-25 " 24-13 1-5 NORMAL 1.5-1 1-6 15-11.4 " 1.8-2.8 " 0.5-3.7 " 5-15 " 1-3 1-4 " 7-3 11-1 2-1 " DO 080807 CONFIDENTIAL -4- - MARINE DOCK //I VINYL CHLORIDE SHIP DISCONNECT EXCURSIONS - PERSONNEL / \ TLV-5 DATE 1/20 1/26 2/8 2/8 3/8 3/8 3/20 3/22 4/14 4/20 kill 5/9 6/17 7/8 7/26 8/1 SHIP PRINS FREDERIK HENDRIK OSCO BELLONA GP-801 GP-802 GP-801 GP-802 EIRIK RAUDE OSCO BELLONA PRINS FREDERIK HENDRIK SOFIE MAERSK SVENDBORG MAERSK AMELIA PRINS MAURITS PRINS MAURITS PRINS MAURITS OSCO BELLONA TOP DECK ONLY NO RESPIRATORY PROTECTION 0.13 0.0 0.19 0.07 WORKED DISCONNECT USED BREATHING AIR 1.08 1.99 1.16 12.25 0.16 0.0002 0.0002 27.57 0.06 3.1 30.51 85.25 49.15 4.0 25.19 9.15 6.0 9.16 0.11 0.10 0.38 32.5 1.18 0.21 0.20 30.98 3.9 0.32 0.08 0.095 0.49 0.20 21.76 1.23 8.09 125.55 2.86 0.26 7.04 8.11 0.41 0.35 4.03 -5- DO 080808 CONFIDENTIAL 38.5 1.3 MARINE DOCK if 1 (cont'd) VINYL CHLORIDE SHIP DISCONNECT EXCURSIONS - PERSONNEL TLV-5 DATE 8/31 SHIP SOFIE MAERSK 9/19 SUNNY PRINCE 9/27 OSCO BELLONA 9/29 REINA DEL RAMA 10/20 ZETA GAS TOP DECK ONLY NO RESPIRATORY PROTECTION 1.31 0.21 0.7 7.17 7.27 WORKED DISCONNECT USED BREATHING AIR 3.67 2.91 11.98 15.52 18.46 23.49 0.34 1.93 20.4 20.9 -6- DO 080809 CONFIDENTIAL MARINE DOCK #2 VINYL CHLORIDE SHIP DISCONNECT EXCURSIONS - PERSONNEL TLV-5 DATE 1/26 GAZANA SHIP 2/20 GAMBADA 2/23 OS CO BELLONA 5/26 6/24 GAZANA GAMBADA 9/3 TARQUIN ROVER 10/1 SUNNY PRINCE 10/7 GAZANA 10/18 GARBETA 11/8 SUNNY PRINCE 11/12 SOFIE MAERSK 11/21 12/1 GAMBADA GAMBADA 12/8 MERWE GAS 12/16 . BERGE FISTER 12/29 BERGE FISTER TOP DECK ONLY NO RESPIRATORY PROTECTION 10.1 1.25 4.81 0.19 0.04 0.45 0.0 0.0 97.5 2.96 0.0 0.43 0.39 0.0 0.21 58.4 0.31 -7- WORKED DISCONNECT USED BREATHING AIR 34.0 46.3 17.1 2.94 2.64 9.13 1.52 0.19 0.83 0.94 12.1 8.3 58.3 57.4 864.0 900.0 0.82 5.99 47.1 29.6 100.05 20.72 2.40 1.38 2.78 1.68 41.4 319.0 308.0 257.0 32.4 76.8 DO 080810 CONFIDENTIAL MARINE ACCOMPLISHMENTS - 1982 EMPLOYEE EDUCATION PROGRAM - 100% PARTICIPATION CONTINUOUS AIR MONITOR IN SERVICE - DOCK it2 PERSONNEL MONITORING OF BENZENE EXPOSURES IN CONJUNCTION WITH PHENOL SURVEYS. MORE SELECTIVE PERSONNEL MONITORING DETERMINED BY PREVIOUS EXPOSURE DATA. MONITOR FOR FRESH AIR INTAKE TO CONTROL ROOM DOCK #2. DO 080811 -8- CONFIDENT! Al MARINE GOALS - 1983 PROTECTING THE PHYSICAL WELFARE OF EMPLOYEES BY REDUCING CHEMICAL EXPOSURES. CONTINUING EDUCATION OF EMPLOYEES - CONSEQUENCES OF OVEREXPOSURE TO CHEMICALS, SURVEY RESULTS, ETC. IMPROVEMENTS TO FAN BLOWER VENT SYSTEM - USED TO VENT BENZENE VAPORS AWAY FROM PERSONNEL LOADING BARGES - DOCK 112. CONTINUING SELECTIVE MONITORING WITH EMPHASIS ON PERSONNEL EXPOSURES TO SUSPECT CARCINOGENS. RESCUE BOAT,AND MOTOR - DOCK HI REBUILDING DOCK #1 - FOUR YEAR PROGRAM CONTINUING EMPHASIS ON LOWERING VINYL SHIP DISCONNECT EXPOSURES. -9- DO 08081? CONFIDENTIAL