Document 25VL4yqyqqbZaL23MbmqGzg7

FILE NAME: Eagle-Picher (EP) DATE: 1969 DOC#: EP035 DOCUMENT DESCRIPTION: Sales Literature w . P H ILIP D U C K W O R TH District Manager Fibers Department EA G tE PICH ER e a g l e -p ic h e r INDUSTRIES, INC. 42 W. Stewart Ave Landsdowne, Pa. 19050 215-626-5877 20-1-224-7440 EAGLE-PICHER INDUSTRIES, INC. D ear Sir: Thank you for your recen t request fo rd a ta on Eagle-Picher Industrial Insulations. We are a d . yu h<* ,h*` it gives you the inform ation you want. If you have fu rth er questions on ^ y of the E a g le -P ic h e r Insulations, please do not hesi e,U o . . . We are eager to help you Very truly yours, CHEMICALS and FIBERS DIVISION EAGLE-PICHER INDUSTRIES, INC. )*** 'J L ow ell D. G ra v e s V ice P resid en t - Sales Fibers D epartm ent TYPE: Pipe Covering ' TEMPERATURE: to 1200 F. EAGLE-RICHER C p h C r m 1200 D escription: Eagle-Picher EPITHERM 1200 is a molded pipe insulation composed of high tempera ture mineral fiber bonded together with heat resistant organic binder for all standard nominal pipe sizes up to 24" in diameter. Long, interlaced fibers are coated uniformly with binder and precision molded in 3-ft. long half sections for ease of application. The fibers are oriented parallel to the direction of the pipe to provide high insulating efficiency and high compressive strength. U s e s : Eagle-Picher EPITHERM 1200 Pipe Insula tion is designed to insulate heated piping operating at temperatures up to 1200F. EPITHERM is especially recommended for use in the power generation and process industries. Advantages: Thermal Efficiency: EPITHERM 1200 has a superior "K" Factor compared to other existing types of pipe insulations. Asbestos-Free: EPITHERM 1200 is a completely asbestos-free molded pipe insulation. Handleability: This pipe insulation is produced from long, interlaced mineral fibers and molded in 3-ft. sections for ease of handling. Being resilient, it will withstand normal mechanical abuse and equipment vibration. Due to the unique physical make-up of the product, break age in transit or at the jobsite is minimal. Installation: This light weight, tough, precision molded covering can be applied with minimum effort at reduced installation cost. The insulation can be easily cut with regular applicator's tools in the field to form mitered sections for insulating flanges and valves. On steam and electrical traced lines, the covering can be installed in the same manner generally followed for other rigid type pipe insulation. High Temperature Stability: EPITHERM 1200 does not shrink, warp, degrade or oxidize at elevated temperatures. As the insulation retains resiliency at the maximum service temperature limit, it absorbs the expansion and contraction of the pipe, thus eliminating open air gaps at the longitudinal and circumferential joints. Being a fibrous insulation, the covering withstands ex treme thermal shock without cracking or loss of thermal efficiency. Corrosion: The pH value of the material is approximately neutral, therefore, it does not cause or accelerate corrosion on metallic pipes. Stress Corrosion: EPITHERM 1200 can be manu factured to meet Specification MI1M-24244 (Ships) for application on austenitic stainless steel. Moisture Resistant: This pipe insulation will resist mildew, mold or bacteria attack. Acoustical Efficiency: Having excellent sound absorption properties, the product is highly recommended to control noise generated by mecahnical equipment and air movement in the pipe. Nesting Sizes: EPITHERM 1200 is manufactured in accordance with the Simplified Dimensional Standards to allow nesting sizes for multi-layer applications. iffl S u fletylciA INSULATION RICHER Page 1.5.5 EAGLE-PICHER epitherm 1200 Physical Properties: Service T em perature......................... to 1200F. Density ......................... Nominal 10 lbs./cu. ft. Moisture A bsorption......................................... Nil Water A bsorption.......................................... None C o rro sio n............... Does not cause or accelerate Fire Resistance -............................. Incombustible Linear Shrinkage at 1200F.......................... None p H .................................... Approximately Neutral Compressive Strength* At 5% Deform ation............... 620 lbs./sq. ft. 10% Deform ation............... 690 lbs./sq. ft. Breaking S trength................................. 23.25 lbs. Modulus of R u p tu re ..................33.5 lbs./sq. in. * Based on 2" thickness of board. Average values obtained in accordance with accepted test methods. Thermal Conductivity: Mean Temperature F. "K" BTU-in./hr./ sq. ft./F. 100 .215 200 .250 300 .300 400 .365 500 .440 600 .510 Standard Sizes: L e n g th .............................................................36" Pipe S ize................................................ H" to 24" T hickness......................... . \ ", I A " and 2" ** Pipe Size H" , %" 1" , VA", VA",2 ",2 lA" 3" , 31A",4 ",4 A ", 5" , 6" 7" , 8" , 9" , 10" , 11" , 12" , 14" 15" , 16" , 17" , 18" , 19" , 20" , 21", 22" , 23" , 24" Thickness 1" , VA" 1" , VA", 2" VA", 2" **Pipe Insulation wall thickness is manufactured to fit double and triple layer nesting as specified in ASTM Recommended Practice C585-68. Applicable Specifications: Commercial Standard ASTM Spec. Federal Specs. Military Specs. CS-117 C547-67 HH-1-558B, Form D, Type III, Class 12, 13 MIL-I-2781D, Giade II, Class C, MIL-I-24244 (Ships)*** *** Requires certification, chemical analysis and special handling. Form No. AF-121 E3PICHER Since 1843 Manufactured by EAGLE-PICHER INDUSTRIES, INC. Fibers Department American Building Cincinnati, Ohio 45202 1969 Eagle-Ptcher Industries, Inc. P rin te d in U .S .A . A 2 7 2