SENT BY:KELLEY DRYE & WARREN ' 2-28-92 = 12-53 KDW 101 PARK AVE 403 348 5313:# 2/10 rrrry.'c:-------------- wt i - INTERNAL CORRESPONDENCE CHEMICALS AND PLASTICS to (ramij CitMPAMV .ouatiom Gfv re. Mr; R- S Corkvtan Or. D. H. Olenn Mr. N. H. Keteham - SI l Mr. h. 0. McMullen - 510 Mr. C. W. Parry - 515 Mr. S. T. Stabile - 519 Mr. R. J. Taylor - 511 Mr. G. Townsend - 529 ^ o*r* *>. e- so* >*. riMs crr. rx >--n Juno 30, 1972 *uiter Asbestos Semolina Equipment Gentlemen: Attached U a list of necessary equipment for personnel sampling oI asbasto* dust ae per the June 7, 1972 OSKA atenderd. Some items you may already have oa head. Please review this list and acquire the needed items so that samples can be takes when I visit. The slides can be prepared and transported to Texas City for counting. After the Initial study, the local plant Industrial hygiene teehnielan should ha ready to sample and prepare the slides on his own and transport them to us for counting. Vary truly yours. OZDtrr Attachment D. X. Oaese Senior Industrial Hygienist Gulf Coast Area UCTC 07280 13-00 : KDW 101 PARK AVE - 409 948 5313-* 3/10 SENT BY KELLEY. DRYE 4 WARREN : 2-28-92 p.7 fINDUS TRIAL HY6IENE D EPT ASBESTOS FIBERS BY PHASE CONTRAST MICROSCOPY Equipment tor Air Sampling and Mounting Mllliporc Filter* /Jdlllipore Field Monitor Case* (Complete) ^ Cat. No. MAWP 037AO IdUlipore Filter* (with pads) , 1/ Cat. No. AAWF 037PO ) Idililpore Filter Corp. (/'Bedford, Mass. 07130 ** . J/dJnieo Mtcronatr Personnel Air Sampler (Part No. 3900-10} J Unieo Environmental Instruments Inc. i/. O. Box 590 v Fall River, Mast. 02722 ** \J&methyl Pthalata K075 ,*H*thyI Oxalate H 888 ^ /. ` ly*T. Baker Chemical Co. iPnUUpsburg, N. J. *** Land Paper ^Cat. No. 268-425 Cdi4ht Scientific Co. ^ousfeon, Texas ee* Stainless Steel Foreeps \S Cat. No. 7050 . | fSelmea Instrument Co. v Ann Arbor. Mich. *** Cejpftng Micro Slides No. 2947 Wethesen Cat. No. 50585-10 / / Cevrtr Class Gold Seal 25 mm / Mffstheion Cat. No. 50507-25 Bar^.Parker Scalpel .Handle - Matheson Cat. No. 19652-10 Yblades - Matheson Cat. No. 19658-20 ttheson Scientific \dtoueton, Texas **e . iWWaton Balaam Bottle XfCj*. No. 034-67$ \mtin 8cU^' UCTC 07281 \ SENT BY:KELLEY-DRYE-VJA^E^ ;. 22--2288--992- ' 13;00 : y^*t- r&*. KDf 101 PARK AVE - 409 948 3313:# 4/10 P.3 INTERNAL LORRE SPONUEII CHEMICALS AND PLASTICS ...mu ; /Mr. Gran Town*end BROWNSVILLE PLANT cc: Mr. R. E. Cork>aa.n Or. O. H. Glenn Mr. R. C. Gluck - 326 Mr. N. H. Keecham -511 Mr. C. W. Porry Mr, R. L. Yolton November 17. 1972 Asbestos Monitoring Otar Grant Thla confirms your telephone retmest for our poelfton nUtiw to ^rovljiwf aahastos fiber count* fur samples collected by Brown and Root personnel. Aher contlderillBR, aft Willing to provide this Service within ibnltations, that U until the work lead prevents it. 8everl thoughts are worth noting. 1) How and when samples are toller lad are extremely Important. Unless the sample Is representative It cannot ba mads so under the microscope. It follow* that the person collecting the sample must be properly trained and supervised to insure representation. 2) Conserving your time by having someone else take aamplas ha# definite limitations from our point of view, especially since mere time may be required to eount the sample than to eollect it. Our work load will no doubt reach a Saturation point where we will need to have additional manpower or terminate the eervtee. 3) The long-range extrapolation of this precedent could very welt precipitate problems with ether materials for which monitoring requirements ere urcly forthcoming. UCTC 07282 : 2-28*92 ' SENT BY:KB1EYK*JP^EN Mr. Oran Town*end KDW 101 PARK AVE 13:00 : 2- - 409 948 5313'-- 5/10 November 17. 1972 4} You may do well to retain duplicate record* with Brown sad .Root lor future reference. 3) You may want to conault the Legal Department relative to liability assumption, Plaaaa contact at when we en l>e of aervie*. Very tsoly your*. DED/Jp D. . Dee** Industrial Hygienist UCTC 07283 KDW 101 PARK AVE - 409 948 5313-* 6/10 P.5 How--bar t. 1871 aSISSTM 1910.93* - TLV 5 flb*/c*3 July 7, 1972, to July 1, 1976 2 fiber#/cn* juiy i, 1976 10 fiber*/cm* Max. 1. Monitorinn (i) bvltmaioMl (b) Personal 2. dacotd Kaaplra of Monitorial (a) Envir--ue <b) Forsoul 3. faployae notification * Mf^al iMpfryHon (a) inpUuim (b) Annual () Tamlaacian 3. Fareonal Froteotlva Egalpweat (a) Eatabllab reeplrator frogn (b) Epeoial Clocking (c) Change loon* (4) Clotboe laekuf (a) Laundering 6. Caution Sian# and Ufeelt t. Honaakeapiag (1) Cleaning (2) Uaata Disposal ^ Practice# (1) Vat Macboda (2) Unpacking (3) Spraying, daaolltion or --novel 9. Traialna Saaalona UCTC 07284 SENT BY-KELLEY DRYE_& WARREN : 2-28-92 ; 13-01 KDW 101 PARK AVE 409 948 5313- 7/10 P.Zi ye <- i internal correspondence CHEMICALS AND PLASTICS CVMPARV ! OCATI0N Mr. G. Townsenc BROWNSVILLE PLANT utc P. 0 BOK 171. HXAH CITY. TtXAS T7^ August 3, 1973 co?r ru Mr, R. C. Clock Mr. G. M. Juneman Mr. W. W. McMaau* Mr, T. L. Rapp Mr. L, T. W indrIt ijktr Brownsville Plant Industrial Hygisnk Visit. Jmv 11-12. 1973 y Dear Gran; As always, my visit to the Brownsville Plant was very enjoyable. In general, environmental improvements were noted. Mr. Lee Windell requested plans for the plant Industrial Hygiene Program including ob jectives and frequency of analyses. The following is a list of projects! Asbestop-'- iy. K. 1910.93a) required sampling SnSast each six month*. This includes gaskets, fitter aides, or other sources. (Texas City Lab will continue to do fiber counting). 2. Noise - Area Sound Pressure Levels - Annually, Audio-dosimetry - Daily. Work areas where audlodosimeter readings exceed 100% need an 05HA Com* ulianee Plan based on Engineering or Administrative control. The criteria document of NIOSH is antici pated to be adopted by DOL - namely, 90 dBA for eight hours and 85 for 16 hours to be reduced in five years to 85 dBA far eight hours and 80 for 16 hours. All new facilities and equipment would be requirod to moot the 85 dBA level, (Reported by Mr, II. Adrian, Chief Industrial Hygiene Programs, Texas Department of Health). VCTTC 07285 SINT BY:KELLEYJ)RYE &J?ARREN : 2-28-92 ; 13 01 KDW 101 PARK AVI - 403 348 5313-* 8/10 P.22 Mr. C. Townsend August 3, 1973 Page 2 3. Sandblasting - Respirable Silica Dust - 6 months. Oil Mist - . months Carbon Monoxide - weekly Check breathing air pumping - weekly (F.R. 1910-94*. 6} 4. Welding Fume - A limited number of welding exhaust systems arc recommended. (Mr, Frank Northcutt at S*adrift has detailed drawings of Rutmelin systems.) All MIG welders should be equipped with commercial exhausters attached to torches. Fume control should be monitored on a six month basis. 5. Spray Painting - Provide approved enclosed spray booths that will collect exhaust spray (F.R. 1910. 107b <!-4)(6-l0) ANSI Z 9.2-1960). Monitor painter's breathing xone for lead and nine 6 months. 6. Wood Shop - Provide approved guards and exhaust hoods lor all woodworking machines. (F.R. 1910. 213 (r)(4) 7. Heat Stress - Reference is made to your letter dated June 15, 1973. We endorse your recommendations. Dr. Joyner recommended in 1959 that "it would seem wise to Jirmt human exposures to A maximum water temperature of 11 5F. " Me found that "meet subjects were unable to hojri their hand against a surface when it reached u temperature in the range of 13) to 140OF." I question that anyone should ascend and descend the fourth level ladder every 15 minutes. Perhaps an teepack suit should be considered during potential long term exposures. 8. Breathing Atr - Reference is made to "Safety Proce dure Guideline" dated July 2, 1973 from R. hi. Gracbcrt. I recall that "crc>w<`-feet'' type hose connectors were m use in the Sandblast Area, `t hese should be exchanged for lock typeHansen connectors or others that arc In compatible with any other system. 9. Toxic Materials - NIOSH Criteria Documents have been published recently for Rcmoenc, Toluene, TDI, and Chronic Arid, you will wish to order them I'm sure. The now TI.V for Toluene is 100 ppm. UCTC 07286 SENT BY:KEU_EY_DRYE WARREN : 2-28-92 : 13:02 KDW 101 PARK AVE - 409 948 5313:# 9/10 Mr. G. Town*end August 3, 1973 Pag* 3 10. Barget Docks - Acetic Acid and Acetic Anhydride vapors should be monitored as a hast* for control evaluation, 11. Brownsville was included as a part of the Gulf Coast Area Industrial Hygiene Laboratory in the Accreditation application. This is to fulfill our obligation under the 19b7 Clinical Laboratories Improvement Act. 12. Budget - $2, 000 was the 5% Brownsville allocation of .the Gulf Coasl Industrial Hygiene Budget. Brownsville trips were pledged on a four month schedule. 13. Membership m the American Industrial Hygiene Association Since you have uron active for at least two years, you ars eligible. encourage you to apply and shall be happy to write the required letter of endorsement. 14. Request* - Last but not least, requests from units and individuals will continue to occupy a large part of your Industrial Hygiene program. This list of subjects Is only a guide since the Department of Labor may change monitoring irequency with the adoption of each per* manent standard. Please contact us if there are questions or if we can be of further help. Very truly yours, D. L, -Deese Senior Industrial Hygienist Gulf Coast Ares tit UCTC 07287 SENT BY:KELLEY DRYE 4 WARREN : 2-28-92 : 13;02 : KDW 101 PARK AVE - 409 948 5313:*10/10 1 * t INDUSTRIAL HVfilENE DEPARTMElB jlRBESTQS DUST STUDY fWprtmant /^fcx^,rfifl62g-- Bldg SfiJ&MVrf Tire. /3 Sampled y A# Analysed By: C A&tY------Iftthod: 4M2&L General Conditions:, 'Tentp. 2armflstii A> firnr/> Sf-fas* ti/t/d AoaiMis- f*> jA'jafcj- ,sx*wJ -Z&2 .W//j&&Sjt- 'afootaL---------------------- & ssestS. 2*/*.Tb*J'J*-/?4su ^.>S&ui ----------------- -- ._ ------ TIBER COUNT (Fibers > 5/t in Lenflthl Slide I . I___________ II 2 _______ 12 3 _______ 13 V ______ IK 5 _____ IS 6 _____ IS 7 ______ 17 e ______ 18. 9 ______ 19 10 20. Avg_ - Slide 2 I_ 2_ 3- M_ 6. 6. 7. 8. 9. 10. Total. II . 12- 13IU. 15. 16. 17. 18. 19. 20, Avg. OLCUUTIBB SAhffLE VOLUME: 30 Min. 9 LPM = & LITERS It.g.f ibtr Coimt-^g,,Blank {Total filter trL C*ntr.tinn,Fib.r./CC > 5A (Counting Area)(VoI.A1 r-Ltters)< 10001 ( ( #0Zs- & .C* Tt r y )( 1L40i/yrlU'WI V = Fibers/ CC > 5A .( JLL ( )( pecial Conditions:. 1 )(1000) Fibers / CC > 5A fewerka: _ /to C#*r/e*4 -- v* 2(m) _____ ______________________________________ ___ _ UCTC012W