Document 216V8gY2q2NKjxQmDg5NvKxr
Air Conditioning
Unit Heaters and Coolers
Grinnell Company, Inc.
Heating, Power and Process Piping, Fittings, Hangers, Unit Heaters, Welding Fittings, Valves, Piping Supplies
Executive Offices: Providence 1, R. I.
Atlanta 2, Ga. Buffalo 6, N. Y. Charlotte 1, N. C. Chicago 9, III. Cleveland 14, Ohio
Billings, Mont. Denver, Colo. Fresno 1, Cal. Long Beach 10, Cal.
Toronto 9. Ont.
Branches Cranston 7, R. I. Houston 1, Texas Kansas Citt 16, Mo. Milwaukee 3, Wis.
GRINNELL COMPANY OF THE PACIFIC Los Angeles 13, Cal. Oakland 7, Cal. Pocatello, Idaho
GRINNELL COMPANY OF CANADA, LTD.
Montreal, Que. Winnipeg, Man.
Minneapolis 15, Minn. New York 17, N. Y. Philadelphia 34, Pa. St. Louis 10, Mo. St. Paul 2, Mjnn.
Sacramento 14, Cal. San Francisco 7, Cal. Seattle 1, Wash. Spokane 15, Wash.
Vancouver, B. C.
THERMOLIER--GRINNELL UNIT HEATERS
Horizontal--Vertical--Textile Types
Horizontal Ddivery Type Regular Construction--finned tubes Textile Construction--udbei tubes
Vertical Delivery Type
Thermolier, the Grinnell quality Unit Heater, is available in three types . . . the regular Horizontal delivery type, the Textile type and the Vertical delivery type. The heating element of the Horizontal and the Vertical delivery types consists of a single header with a series of copper, pitched, finned U-tubes while the Textile type utilizes a single header with a series of copper, pitched, webbed U-tubes.
Basically, all three types incorporate the same quality features. Among these are the patented Internal Cooling Leg.which assures continuous drainage of condensate, and the Single Header U-Tube construction which compensates for expansion and contraction strains.
Thermolier motors are not standard stock motors but are built to exacting speci fications for unit heater duty. This assures maximum life at maximum operating efficiency with the minimum of electrical input. Fans have aluminum blades-with special steel hubs and are made to specifications to insure accurate balance, minimizing noise and vibration.
Supply and return piping are both on the same side of the unit, assuring compact ness, neatness and economy in installation. Each Thermolier is furnished with ad justable swivel couplings which provide an easy and practical method of hanging the unit and facilitate adjustment after erection.
The housings of all units are formed from heavy gauge sheet steel and are finished in attractive artmetal slate gray.
1134
Grinnell Company, Inc.
Air Conditioning Sd'cSSf8
CAPACITIES--GRINNELL THERMOLIER
All based on Standard Basis of Rating (2 lb Steam Pressure and 60 deg Entering Air Temperature)
Horizontal delivery models--for constant speed operation, use bold face figures only --for two speed operation, use both figures
model
rpm at normal speeds
total heat delivered Btu per hr
equivalent direct
radiation edr
cfm at exit air
temp
D21
1725
35,600
148
637
1250 29,700 124 482
D31
1725
48,700
203
689
1250 38,400 160 513
D37
1140
62,200
259
1062
950 54,200 226 874
D41
1725
71,000
295 1271
1250 56,000
233
914
D44
1140
84,100
350 1250
750. 63,000
262
852
D57
1140 101,300
.422
1433
675 84,400 352 1127
D66 1140 128,700 536 2166
625 90,000 375 1340
D71 1140 151,700
632 2716
625 103.000 423 1592
D91 1140 196,000 817 2738
625 127,500 - 532
1551
Dill
1140 640
275,300 195,700
1147 815
5095 3342
Capacity tables for hot water Thermolier on request.
exit air temp F
conden sation lb
per hr
116 37 122 31 133 50 138 40
119 64 123 56 116 73 122 58 129 87 137 65 133 105 138 87
120 133 129 93 116 157 126 107 134 203 147 132
114 285 119 203
air veloc ty at exit--linear ft per min
louvers wide open
louvers set at
45"
velocity nozzle max
786 912 1336 595 690 1011 851 987 1447 633 734 1076
753 620 901 648 887 604 1016 799
779 482 977
673 985 558
949 781 1135 816 1118 761 1280 1007
982 607 1231 722 1241 703
1160 955
1388 998
1366 930
1565 1230
1332 824
1671 980
1684 954
1048 688
1415 929
1803 1183
Vertical delivery models--for constant speed operation, use bold face figures only --for two speed operation, use both figures
model
VA1042 VA1045 VA1065 VAI075 VA1101 VAltll
rpm at normal speeds
1725 1250 1725 1250 1140 625 1140 625 1140 600 1140 640
total heat delivered Btu per hr
50.800 40.100 73,600 59,900 109,400 74,500 145,600 94,200 185.000 122.200 257,000 187.000
equivalent direct
radiation edr
212 167 307 249 456 310 607 392 770 508 1071 729
cfm at exit air temp
1483 1078 1363 995 2869 1630 2609 1402 4510 2517 4921 3105
exit air temp "F
93 96 114 121 97 105 116 129 100 108 112 121
condensa tion lb per hr
53 41 76 62 113 77 151 98 191 126 266 194
air velocity at exit ft./
min
1399 1017 1287 939 1354 769 1231 662 1495 835 1631 1030
Textile models--constant speed operation
model
rpm at normal speeds
total heat delivered Btu per hr
equivalent direct
radiation ' edr
cfm at exit air
temp
exit air temp. "F
TX70
1140
69,800
291 2297
89
TX110
1140
113.700
474
2438
106
Textile Thermolier not available for hot water systems.
conden sation lb
per hr
72 118
air velocity at exit--linear ft per min
'louvers wide open
louvers set at
45
velocity nozzle
mar
826 1041 1412 877 1105 1500
Grinnell Thermoliers are tested and rated in accordance with rules of the Industrial Unit Heater Association adopted January 1930.
1135