Document 1yrG5E1x4xnZex44Y3mv39ygX
Air System Equipment Fans and Blowers
American
Corporation
3604 Mayflower Street, Jacksonville 3, Florida
Exhaust Fans and Related Equipment for Industrial and Home Cooling
Authorized Distributors and Dealers in Most Communities
District Representatives:
Atlanta, Ga.--John L. Underwood Co- Inc., 655 Whitehall St., S.W.. Atlanta 3, Ga. Phone Main 7878 Cincinnati, Ohio --Halsey E. Kendrick, 5167 Valley Ridge Road. Cincinnati 1!, Ohio, Phone Humboldt
4573 Dallas, Texas--J. D. Clower, Whitewright, Texss. LD Phono, Whitewright 919F2. Jackson, Miss.--Bert White, P.O. Box 4264, Jackson 6, Miss., Phone 6-4853 New Yobk, N. Y.--E. R. Dexter, 117 N. Middletown Rd., Pearl River, N. Y., LD Phone Pearl River 5-2725 Washington, D. C.--Robert A.Magee, 7402 Columbia Ave., College Park, Md., Phone Warfield 1480.
COOLAIR BELT DRIVE FANS are specifically engineered to move large volumes of air quietly and at low cost. Certified Ratings: Coolair Fans are rated in accordance with the ASHVE Standard Test Code for Centrifugal and Axial Fans (1938). In addition, most sizes up to and including 62-inch are rated by the A&M College of Texas. Exclusive Ball Bearing Hub with sta tionary shaft and ball bearing motors insure long life and permit mounting in any position.
Single or Twin Units--To simplify space problems Coolair Fans through the 50inch size are available in twin units driven by a single motor (U. S. Patents 2109838 & 2191418).
Types H and HT (Twin)--For home and commercial use where ultra quiet opera tion is required, these slow speed units with integrally mounted spring suspen sion (U. S. Patent 2191418) are recom mended. Most models available with 2-speed motors. Types C and CT (Twin)--For heavy duty commercial and industrial applications, these rigid frame, high output units are indicated. Available without motors or fitted with standard semi-enclosed, en
closed, and explosion proof motors for all types of service.
Types S and SX--Recommended for large industrial applications where large vol umes of air must be handled. Heavy duty, double frame construction with special pillow-block, ball bearing drive. Small Fans and Accessories--A complete line of Window Fans, Direct Drive Fans, Attic Packages, Ceiling Shutters, Wall Shutters and Guards. Write for descrip tive bulletins.
CONDENSED PERFORMANCE DATA and DIMENSIONS
Coolair V-Belt Drive Exhaust Fans
TYPE H (Ultra-quiet, spring-mounted)
ej __ Overall Dim.
ja *3 r\
hp
5
rpm
cfm (inches) Hfc Width
26 X
490
4350 30** 304*
32 54 420, 475 7730, 8620 3654 36V*
38 , 331, 371 9800, 11050 4244 42V*
44 54, X 291, 326 13300, 14670 49
49
50 54,54 284, 318 17250. 193C0 55H 55Vr
56 55. 54- 242, 272 20000. 22500 61V* 61X
62 54.54 216, 241 24400, 27200 6754 6744
Two-speed units available in all sizes
TYPE HT (Ultra-quiet TWIN UNITS)
26 32
468
8400
3054
X.X 361, 420 13000, 13460 3654
6154 73 54
38 X
326
19300
4244 85ki
44 %
317
28800 49 98
50
284
34500
55** 110V*
Two-speed units available in all sizes below 1 hp
TYPE C (Commercial, Rigid Frame).
26 X to x 612 to 780 5450 to 7200 3054 32 X to 54 485 to 651 8200 to 10456 3644 38 X to I 355 to 552 10000 to 14670 4244 44 XtolX 330 to 494 13250 to 19450 49 50 H to 3 318 to 496 19300 to 30000 55V* 56 X to 2 272 to 370 22500 to 30000 61V* 62 1 to 3 261 to 369 29300 to 41500 6754
3054 3654
4254 49
5654 6154 6754
TYPE CT (Commercial Twin Units)
x,x26 557, 612 9800 to 10900 3054 6154
32 54.54 441, 523 14600 to 17100 3654 73V*
38 54,54 334, 378 18200, 20600 4254 8554
44 H. l 309, 330 24800. 26500 49
98
50 1 to 2 284 to 351 34500 to 42600 5554 11054
TYPE S (Industrial Units)
72 |1 to 5 1155 to 270135000 to 600001 75tf I 75K 84 |2 to 7V*ll70 to 270158000 to 85000l 87 I 87
TYPE SX (Industrial Units)
96 3 to 10 150 to 225 80000 to 120000 99
108 5 to 15 150 to 215 110000 to
11154
154000
99 11154
1276
Air System Equipment *nd Blower,
Bayley Blower Company
1821 S. Sixty-Sixth Street Branches in Principal cities Milwaukee 14, Wis.
Engineers'and Manufacturers of Fans, Washers, Heaters and Other Air-Handling Equipment
CENTRIFUGAL FANS
Bayley offers a complete selection of types, sizes and arrangements of centrifugal
fans for ventilating, conditioning, industrial, and mechanical draft service, with
slow-speed, power-limiting, or medium speed wheels. Made in single or double
widths, with capacities up to 300,000 cfm or more. Smaller sizes have reversible hous
ings for convenience and economy.
INDUSTRIAL FANS
Bayley Industrial Fans are available in a wide range of sizes and constructions from
which to select the unit best fitted for any application in exhausting, conveying,
cleaning, drying, blast, draft, or similar duties. Type "EX" is proportioned primarily
for medium pressures and capacities usually encountered in materials handling or
exhaust. Type "H" is similar, but proportioned for relatively higher pressures and
smaller volumes. Designs are adaptable to suit virtually any requirement of tempera
ture, corrosion-resistance or other severe operating conditions.
VENTILATING FANS
Type "F" FanB are equipped with wheels having forward-
curved floats, effecting a slow-speed characteristic. The floats
of the wheels supplied with Type "A'P" Fans are backwardly
inclined, producing a non-overloading characteristic. Choice
of fans is determined by the design conditions of the individual
installation. VENTILATING SETS--Compact, unitary Ventilating
Sets are manufactured with drive complete, ready to use,
direct-connected and belted styles with capacities to 15,000
cfm. These handy units serve a wide variety of applications in
ventilation and exhaust, for kitchens, lavatories, gymnasiums,
restaurants, garages, halls, hospitals, laboratories, industrial
plants, and many other locations. May be used for supply,
exhaust or both. They can be equipped with weather-protection
hood for outdoor or penthouse installation. Carefully engi
Type
Wheel
neered and sturdily built to give long-lasting, efficient service.
AIR WASHERS
Because Turbo washers atomize by mechanical means, they cannot clog, hence are admirably suited to handling air contaminated with particulate mat ter. Standard pressure-nozzle washers also available for use where dust content is light.
Turbo Washer
BLAST HEATERS--The finless, long-lasting iron pipe coils of Chinook Heaters will not clog, therefore maintain full capacity longer. Pipe-within-a-pipe arrangement has single header for supply ana return, cannot short-circuit, and absorbs expansion and contraction without damaging stresses. A size and type for
any blast heating application. Chinook Healer
1277