820 CHAPTER 52 1965 Guide And Data Book called portable firebox boilers, and are the mostjcommonly surface, its distribution, and the temperatures on either used type. They are usually shipped in one piece, ready for thereof, influence the capacity of any boiler. piping connections. Direct heating surface has higher heat transfer rate per unit A packaged steam boiler (also called steam generator or hot of area because it is generally subjected to higher temperature water generator) is a modified boiler unit having all compo differences and because, with solid fuel and certain other nents, including burner, boiler, controls, and auxiliary equip fuels which burn with radiant flames, the direct heAting sur ment, assembled as a unit. Larger packaged boilers or genera face absorbs an appreciable amount of radiant energy. tors are usually of a modified Scotch type. Smaller units are Die-effectiveness of the heating surface depends upon its usually of the fire box type. cleanliness, its location in the boiler, and the size and shape Capacities of steel boilers range from those required for of the gas passages. Where fans or blowers are used to create small residences up to about 17,500 MBh. draft, high gas velocity may be employed to increase heat : 'transfer in secondary heating surfaces. This may be accom Boilers for Special Applications plished by baffles or by nsing small or narrow flue passages. Boilers for hot water supply are classified as -direct, if the Heat transfer from flue gases in the turbulent flow range in' creases with velocity. Where high pressure fang are used for water heated passes through the boiler, and. as indirect, if' the water heated does not come in contact with the water or steam in the bofier, ... '' q draft, the noise level must be considered. Where natural draft is employed, the area of the gas passages must not be so small as to cause excessive resistance .to flow. Direct heater* are built to operate at the'pressures found' in city supply mains, and are tested at pressures from 200 to-' i Heat Transfer Rate 300 psig. The life of direct heaters depends almost entirely on the scale-forming properties of the water supplied and the temperatures maintained. If low water temperatures are . maintained, the life of the heater will be much longer due to decreased scale formation and minimized corrosion. Direct water heaters in some cases are designed to bum refuse *nd garbage. Indirect heaters generally consist of steam boilers in con nection with heat exchangers of the coil or tube types which transmit the heat from the steam to the water. This type of Average overall heat transfer rates, expressed in BTU per sq ft per hr, will range from about 3300 for atmospheric vented hand-fired boilers, to over 8000 for power vented high draft loss boilers. The practical firing rate for any particular boiler depends upon its design and, to a certain extent, upon the method of firing. Some boiler rating codes take into account minimum heating surface, thereby establishing maximum heat transfer rates; other rating codes take into account actual performance determined by test. installation the following advantages: RATING AND TESTING CODES 1. The boiler operates at low pressure. 2. The boiler is protected from scale and corrosion. 3. The scale is formed in the heat exchanger in which the parts to which the scale is attached can be cleaned or replaced. The accumulation of scale does not affect efficiency,- although it will affect the capacity of the heat exchanger. 4. Discoloration of water may be prevented if the water sup ply comes is contact with only nonferrous metal Where a steam or a forced circulation hot water heating system is installed, the domestic hot water may be heated by an indirect heater attached to the boiler. For most satisfac tory performance in the steam system, this heater is placed just below the water line of the boiler. In a forced circulation hot water system, it should'be located as high as practicable with respect to the boiler. BOILER DESIGN CONSIDERATIONS Furnace Design Good efficiency and proper boiler performance are depend ent on correct furnace design. There must-be sufficient vol ume for burning the particular fuel which is used, and there must be means to obtain a thorough miring of air and gases at a high temperature and at a velocity low enough to permit complete combustion of all the volatiles. .For'hand-fired boilers, the furnace volume should be .large enough to hold sufficient fuel for reasonably long firing periods. (See Chapters 18 and 51). Heating Surface - BoOer hasting surface is that portion of the surface of'the heat transfer apparatus in contact with the fluid being heated on one side and the gas or refractory being cooled on the other side. Heating surface on which the fire'shines is known-as direct or radiant surface, and that in contact, with hot gases only, as indirect or convection surface. The amount of heating Hpftting boilers are usually rated according to codes de veloped by the Steel Boiler Institute, the Institute of Boiler and Radiator Manufacturers, the American Gas Association, the Mechanical Contractors Association of America, and the Packaged Firetube Branch of the American Boiler and Affili ated Industries. These test codes have been prepared specifi cally for the purpose of obtaining information required for es tablishing acceptable ratings. The various current rating and testing codes will' be discussed in following paragraphs in which limitations, methods of application, and resulting rat ings will be described. The Steel Boiler Institute has adopted a rating code for boilers designated Table 1 Steel Boiler*, Table 2 Steel Boilers, and Table S Steel Boiler*, and a testing code for Oil-fired Table 2 and Table S Steel Boiler* (SBI Rating Code, Eighth Edition, February 1958). Tables 1, 2, and 3 of this'chapter show the SBI Gross Outputs and Net Ratings of three classes of boilers.- '> The Table 1 boilers (defined as those having 129 to 3571 sq ft of heating surface and formerly' designated as Com mercial boilers) are rated in square feet EDR design load (steam) on the hams of heating surface with limitations set for grate area, furnace .volume, and furnace height. The Table 2 boilers (defined as those having not more than 294 sq ft of heating surface and formerly designated as Residential boilers) are rated on' the baas of heating surface with ratings confirmed by test The Table S boilers (defined as having no limits of minimum heating surface or furnace volume, and having Gross Outputs and Net Ratings listed in Table 3) are rated on the basis of performance under the provisions of Section III, Part 2, of the SBI Rating Code. The minimum stack area dimensions to be cataloged for Table S boilers are shown in' Table 4. Required stack heights are found in the catalogs of the manufacturers. Stoker-fired and gas-fired Table 2 boilers are rated (SBI Net Rating) not in excess of the oil-fired rating. Hand-fired Table 1 .. . SBI Ratings tor Table T.'Stoel BoilersI 41,150' 61,440 62,000 72,000 :Heating Boi!ers, Furnaces, Space Heaters 821 o .a. .E \ti 1 C9 PS 5j Vi- ^ ^ r -r - '* 2 e 2 00 0 d ci o _ 1 ' off -- (- o J -S 2 v I0<"- - a n 5 3 5,-_ = * ci -- ej . 2SSJ !! ill ill cf eo eo C4 -4< C4 CS cS 5 3 ^' 0 0 S|| CO z !- 1 ff -- - ff I*1- -COD W NO eg o 8 ra PgSg So CO CCOO 8O' 8 8 5385 0 o' ss CO CO -c J i & n 1i Sc SS iii ill 11! iiil ff ~ og ec - S* = in ill oo 111 8 88 saa S S S3 S s' s' 'c 6 -- III; !!! zr -- x <o a N 00 o a,, in " a * v* ' s S. gggf . g g E 2ll|i V* X 8S3 , CO CO 8 88 N J C" 8 SSS B 88v^ . ) . 1 Cl Cl S3S .52 88 S 3" 3 isS s 6 T 2 C.U. - -. ' is?*" ' -3^ Sit S sss TU$3-~ ' s I !*, - 2 I O TT g S3 1s S5O ? ff -- 5C5S- ocCToi CaDs S8 ' n " x" - " v g- 3 s s^ s III- - *" -v- ' US CD SCO ; 8 3,C4.; .1 " 1 ff _ s S, *-T as ,,-c. E A J) . 8CO S 8CO >88 .0)0- c c *o III s SIS 00 8 8 8t-g ,rt; 111 c*~ go *o r-T S r2 S' N CO g goCO ci of C4- CO noon KnS8 -rrt 00 CO ill li|| -^ oo C4- , eo O SEC- 8-- 8: 8OO 8-- 8 1 (D V Tf oo O Cl CO %1 I il | *!J HI 28eq 8 '. 0 0 SsS. o CO 00 s 4a s s SSS 8 8SC4 C-* ` - ** . 0o '9! <s -H ills Cc4* CaSl n CaO> . ' 3 13 :I I s J. s -a 2 If! *i1 1i s i || ef co Kg 8 cS.ll1 g r-" aT 0 ci co . 11 it III 3 ^ `SSS. 8 S S5 . :|SS, 88 |'g O CO 2 S SI ! n'n nco I'.ll S-S.S 818. s S '3 | -S; 2. I 2S \ `ZL. 9 J3 ja 5s I!*f. i 3 Ia o r f.