Document 1gY75wD6qMZ2wD4q2bv1aDp2q

E C KN I CAL BULLETIN PYDRAUL 312 FIRE-RESISTANT HYDRAULIC FLUID Pydraul 312 Fire-Resistant Hydraulic Fluid ... a synthetic fluid that gives you the performance of premium grade petroleum oils -- plus safety -- at the price of water/glycols. [J jj [1 M I'AtOiwfilTlM LjvO TOWOLDMONOQ26427 J PYDRAUL 312 FIRE-RESISTANT HYDRAULIC FLUID Pydraul 312 Fire-Resistant Hydraulic Fluid . . . a synthetic fluid that gives you the performance of premium grade petroleum oils -- plus safety -- at the price of water /glycols. * TECHNICAL BULLETIN O/FF-7 o ~Nothinttn1lindN*t*initlob*cnitimdsiiiscemmn6i1wntftHUSftP'diKtin tnAKtrth nrMttnl. MONSANTO MAMS NO WARRANTl[S AS 10 IHt HI MSS OR MlRCHANTASll ITT OF ANT PRODUCTS RUIRRID TO. ns (sionln s' utuUder, i.iuilt liom isl.sncs upon tenlAinsd inli(n*lnw (scsnimrndiliOAt, *nd diKUni si lisbiiily Im sni itivMini Iniw KatMsisd TisdsmiA sf Msnunls Csmssny Organic Chemicals Division/800 N. Lindbergh Bfvd./St Louis, Missouri 63(66 02Z1B0A 1 TOWOLDMONOQ26428 Table of Contents Page INTRODUCTION....................................................2 PROPERTIES Inspection........................................................ 3 Corrosion and Stability.................................. 4 Fire-Resistance................................................4 Performance....................................................4 CHANGE-OVER PROCEDURES.......................... 7 HANDLING AND STORAGE.............................. 8 Introducing Pydrauf 312 Hydraulic Fluid Pydraul 312 is the first of Monsanto's new high performance low cost fire-resistant hydraulic fluids. This synthetic is the latest innovation in Monsanto's internationally accepted and growing line of fire-resistant hydraulic fluids and lubricants. In 1951 Pydraul hydraulic fluids first began work ing to protect hydraulic operations from fire. Now, well over a decade later, the seven Pydraul fluids have performed millions of machine hours of service without contributing to a single fire . . . not even when sprayed from ruptured highpressure hydraulic lines onto white-hot metal. And besides fire-resistance, the Pydraul fluids have always offered . . . ... lubrication as good as premium grade oils ... freedom from corrosive action and foam ... ease of maintenance .. . and permanence -- they don't "wear out" Where does new Pydraul 312 fit into this well established picture? Pydraul 312 hydraulic fluid is a unique marriage of synthetic fluids with specially chosen petroleum fractions. The result is a fire-resistant hydraulic fluid that matches or excells the properties of existing hydraulic fluids -- including synthetics premium grade petroleum oils, and water-contain ing fluids -- but sells in the same price range as water/glycol fluids. They offer up to 10% savings over other water-free, fire-resistant hydraulic fluids. 0221805 I TOWOLDMONOQ26429 Inspection Properties ... Viscosity, SSU < 40F Viscosity, SSU (ri 100F Viscosity, SSU & 210F Viscosity Index Pour Point. F Density 25/25C Grams/cc pounds/gal ASTM D-892 Foam Test Sequence I Sequence II Sequence III 4200 312.0 50.9 +77 -10 1.095 9.26 Pass Pass Pass The viscosity and viscosity index of Pydraul 312 are very similar to those of a high quality R&O (rust and oxidation inhibited) type petroleum hydraulic oil as the following comparative vis cosity curves indicate. TEMPERATURE, DEGREES FAHRENHEIT \ 022X 606 -------------1 TOWOLDMONOQ26430 Corrosion and Stability ... The corrosion and oxidation stability properties of Pydraul 312 are equal to those of the best petroleum hydraulic fluids. Pydraul 312 will not rust or corrode any metal in a hydraulic system even when over-heated to 250F. In the ASTM D-665 Rust Test Pydraul 312 showed no rust at all, and in use Pydraul 312 does not lose its anti-rust properties. Good hydrolytic stability is a basic characteristic of Pydraul 312. If water somehow enters your hydraulic system, Pydraul 312 won't hydrolyze to foam acidic or corrosive products. Beverage Bottle Test (Pydraul 312 plus water aged @ 200F for 168 hours with a copper strip through both phases). Neutral No. change, mg KOH/mg Viscosity change, % & 100F %<8',2m Insolubles Weight loss, Cu strip, mg/cm2 0.04 --0.6 -1.3 none none Fire Resistance ... Pydraul 312 is an industrial fire-resistant hydrau lic fluid listed by Underwriters' Laboratories. Miscellaneous Fire-Resistance Tests ASTM D-286, Auto. Ign. Temp F 940 High Pressure Spray Test (AMS-3150C and Federal Test Method STD791). Test fluid sprayed at 1000 psi through orifice, passing through flame of oxyacetylene torch, 6000F. Intermittent flashing but self-extinguishing. Low Pressure Spray Test (AMS-3150C). Test fluid sprayed at low pressure over ignited, oil-soaked rags to determine degree of increase in flame intensity. Slight increase in flame intensity, Hot Manifold Test (Federal Test Method STD791) Test fluid dripped on tube at 13Q0F. intermittent flashing but does not propogate to pan below. Molten Metal Ignition Test. Test fluid exposed to the surface of aluminum alloy at 1200F to test for spontaneous ignition. Does not ignite spon taneously. Flashes intermittently with ignition source. Your Monsanto representatives will be glad to show you color motion pictures of the performance of Pydraul 312 in these tests. To test fire-resistance under working conditions, Pydraul 312 was sprayed on actual ignition sources in operating plants. In no case was a fire carried from the immediate source of ignition. In one plant, a line rupture on a die-casting machine sprayed Pydraul 312 onto molten aluminum in a holding furnace and over the surrounding area. Flame was confined to the furnace, no plant per sonnel were injured, and there was no fire damage. Performance Properties ... Pydraul 312 has good viscosity and viscositytemperature (V I ) properties. These properties are permanent. Pydraul 312 will not shear mechanically to degrade viscosity. The following chart shows viscosity of Pydraul 312 before a Vickers Hydraulic Pump Test... and practically the same viscosity after the test. e 0221807 TOWOLDMONOQ26431 TEMPERATURE. DEGREES FAHRENHEIT JO 000 to jo oo too no in no 10 000 A.S.T.M. STANDARD VISCOSITY-TEMPERATURE CHARTS 1000 41000000 FOR LIQUID PETROLEUM PRODUCTS (D 341) CHART B: SAYBOLT UNIVERSAL VISCOSITY, ABRIDGED Pydraul 312 Sayboft Viscosities ---------- C efore Vickers Pump Test * s ---------- After Vickers Pump Test N S -*> t to oo ioo no in no uo iso iw no iso no joo no j?o no no ?so no no no no no TEMPERATURE, DEGREES FAHRENHEIT Pydraul 312 lubricates as well or better than High Quality RtfcO and antiwear type petroleum hydraulic oils. Vickers Hydraulic Vane Pump Test (V-105E pump, 1000 hours, 140F, 1000 psi). % Viscosity change <& 100F (. 210F --4.3 -1.0 Weight loss of pump parts, mgs bushings, 201$ bushings, 2016 ring vane nil --5.7 --1.3 --2.1 r Premi m R & 0 Oil i __ 1 Pump Type: Vickers V105C 8 GPIVI Fluid Viscosity at test temperature: 70 SSU Fluid Temperature: Adjusted to give 70 SSU viscosity Pump Pressure: 1800 PSIG Pump Speed: 1200 RPM Ant wear 0 1 No. 1 ^1 Antiwear Oil No. 2 1 Pydraul 312 l 50 100 150 200 250 TEST TIME, HOURS 0221806 TOWOLDMONOQ26432 Four Ball Wear Test (620 rpm, 1 hour, 167F) Steel on steel, mm scar diameter 4 kg load 10 kg load 40 kg load 0.24 0.25 0.44 Steel on bronze 10 kg load ' 0.87 Oilgcar Radial Piston Pump Test (DS 425 pump, 1000 hours, 130F, 3000 PSIG, pump speed 1200 RPM). Pydraul 312 Fluid % Viscosity change <js 100F 210F Acid No. increase mg KOH/g 12.3 4.9 0.9 Premium HVI Oil % Viscosity change ( 100F Cri) 2)0F Acid No. increase mg KOH/g --4.2 -1.0 0.7 See results below: Timken Test Timken OK load, lbs. 65 Pydraul 312 lubricates under extreme pressure as well as high-quality industrial gear lubricants. Field Tests In addition to the laboratory tests, field tests in varied equipment such as automatic multi-welders, die casting machines and mobile steel mill equip ment indicate Pydraul 312 will give years of trouble-free pump service . . . the same or longer pump life afforded by petroleum hydraulic oils. And Pydraul 312 doesn't wear out. Except for normal "make-up", ... you don't add water . . . you don't have "drain and change" periods .. . you don't have to check it daily ... or perform most of the other-time-consuming maintenance necessary with water-containing fluids. o Ll. S 10.0 o UoJ 2 ________ - HVI Oil 550 SSU @ 100" F (119cs) PYDRAUL 312 312 SSU @ 100 F (67cs) 6.0 200 400 600 800 1000 TEST TIME, HOURS CONDITION OF PUMP AFTER TEST: Generally good in all cases. CONDITION OE OIL AND FLUID AFTER TEST: Properties not substantially changed. # 0221809 6 TOWOLDMONOQ26433 Change-Over Procedures Converting to Pydraul 312 hydraulic fluid is easy. Virtually every type of equipment that uses fireresistant hydraulic fluid has been converted to Pydraul fluids. Equipment manufacturers are, therefore, experienced in Pydraul fluid conversions and should be consulted. ' If changing seals is necessary, equipment manu facturers can tell you what seals to change, and most even carry a supply of correct seals. Labo ratory tests show that Viton and silicone seals are best for Pydraul 312. To replace other Pydraul fluids with Pydraul 312 where compatible seals are in the system, it is only necessary to add Pydraul 312 as make-up fluid. It is not necessary to drain or clean. When you convert from petroleum oils, non-Pydraul synthetic fluids, water/glycol fluids, or water-in oil emulsions, we recommend the following steps. These steps conform to National Fluid Power Association Standards. Your Monsanto representative will assist you any way he can, or you can telephone our technical specialists in St. Louis directly. Changing from Phosphate Esters (other than Pydraul) (1) Drain the system completely. (2) Cleaning is unnecessary. (3) Generally, seal changes are unnecessary. Changing from Petroleum Oil 1. Completely drain and clean the system. Small amounts of oil will not interfere with the per formance of Pydraul 312, but resistance to fire is reduced by the amount of oil left in the system. Iradtnwk ft (. I. <iNM 4* Ntaiwft I Cfc, lac. 2. Drain and blow out pipelines. Manually clean valves and reservoirs. 3. Open or remove and drain valves. Replace gaskets, packings, and seals with those com patible with Pydraul 312. It is particularly important to change dynamic seals. Static seals do not necessarily have to be changed if there is no objection to replacing them each time hydraulic components are serviced. 4. Remove pumps, accumulators, and cylinders, if necessary, for draining. Replace packings, seals, gaskets, and bladders with those com patible with Pydraul 312. 5. Check component functions before the system is closed and fluid is added. 6. If your system cannot be completely drained, you may have to flush it with a small amount of Pydraul 312. Changing from Water/Glycol or Water-in-Oil Emulsion 1. Drain and clean system thoroughly. Remove all traces of water. Empty all lines and low points or dead pockets in components. 2. Clean with steam or warm water. Follow by blowing with dry air. 3. Check sealing materials, hoses, and accumu lator bags. Replace if necessary with compatible materials. 4. Install a minimum charge of Pydraul 312 and operate the system from 16 to 24 hours. During this period, inspect the reservoir. If water or other contaminants float to the top, skim them off. 5. Drain the flushing charge immediately after shut-down while the fluid is warm. Drain all isolated points or parts which do not drain back to the reservoir. If water is apparent in fluid clinging to walls, wipe down all accessible parts. OZZ*810 TOWOLDMONOQ26434 Handling and Storage , As with all specialized industrial fluids, certain precautions are advisable when handling Pvdraul 312. No problems will arise when Pydraul 312 is list'd as recommended. Avoid repeated or continuous skin contact. Re peated or prolonged contact can lead to drying and skin "chapping". Where prolonged skin con tact cannot be avoided, gloves should be worn. At room temperature there is no significant vapor inhalation hazard from Pydraul 312; however, in halation of vapors produced when the fluid is at high temperatures should be prevented. Single G-hour exposures to an atmosphere saturated with vapors at ambient temperatures produced only mild discomfort in experimental animals and they survived the 10-day subsequent observation period without ill effect. Although eye irritation studies using Pydraul 312 at full strength indicate Pydraul 312 is a mild irritant, there is no evidence to show Pydraul 312 causes permanent damage to eye tissue. If Pydraul 312 is splashed or sprayed into the eyes, eyes should be thoroughly flushed with water and the workman referred to a physician. To relieve irri tation, physicians have used 1% tetracaine solu tions, as well as ophthalmic cortisone acetate solution. Pydraul 312 hydraulic fluid can be stored at sub zero temperatures without fluid damage. Before using, simply allow the fluid to warm to 20 -- 30F. Drums stored outside should be sealed tightly and placed in a horizontal position to keep out moisture. 8 DISTRICT SALES OFFICES ALL DIVISIONS ATLANTA. GEORGIA 30326 Lenox Towers East 3400 Peachtree Rd. N. E. - Suite 1711 Tel. (404) 577-2260 BOSTON, MASSACHUSETTS 02149 Everett Station Tel. (617) 387-5010 CHICAGO, ILLINOIS 3158 Des Plaines Ave. Des Plaines, Illinois 60018 Tel. (312) 296-6688 CINCINNATI, OHIO 45206 1501 Madison Road Tel. (513) 751-6707 CLEVELAND, OHIO 44122 3645 Warrensvi/le Center Rd Tel. (216) 991-5400 DETROIT, MICHIGAN 48235 500 Northland Towers East Tel. (313) 357-0910 HONOLULU, HAWAII 96812 205 Pacific International Bldg. 677 Ala Moana Blvd., P. 0. Box 3824 Tel. (808) 512-744 HOUSTON, TEXAS 77002 1300 Main Street Tel. (713) Capitol 3-4011 LOS ANGELES, CALIFORNIA 90022 6670 E. Flotilla St. Tel. (213) 723-2492 MINNEAPOLIS, MINNESOTA 55402 912 Northstar Center 110 S. Seventh St. Tel. (612) 339-4651 NEW YORK, NEW YORK 10017 277 Park Avenue Tel. (212) 922-4111 PITTSBURGH, PENNSYLVANIA 15222 No. 4 Gateway Center Bldg. Room 534 Tel. (412) 261-2156 ST. LOUIS, MISSOURI 63166 600 N. Lindbergh Blvd. Tel. (314) Oxford 4-1000 SAN FRANCISCO BAY AREA 2710 Lafayette, Santa Clara, Calif. 95052 Tel. (408) 243-0414 SEATTLE, WASHINGTON 98104 911 Western Avenue Tel. (206) Main 2-4203 SPRINGFIELD, MASSACHUSETTS 01101 730 Worcester Ave. Tel. (413) 788-6911 WILMINGTON, DELAWARE 19803 2005 Concord Pike, Fairfax Tel. (302) Olympia 8-6531 MONSANTO. 800 N. LINDBERGH BLVD.. ST. LOUIS, MISSOURI 63166 0221 dll 0 TOWOLDMONOQ26435 TOWOLDMONOQ26436