Document 1gNzDK4rnm5ZoEzKJL0E3JD4a

DOW CHEMICAL U.S.A. OCTOBER 16, 1985 LOUISIANA DIVISION P. O. BOX ISO PLAQUEMINE. LOUISIANA 707S6-O160 604 38B-S000 HUGO ANDRICAIN - MAJOR MANAGER TONY GRANT - RAILROAD BILL HERRIN - RAILROAD 0. C. DICKERSON - RAILROAD GLYNN SMITH - TANK CAR CLEANING DANNIE KENNEDY - INDUSTRIAL HYGIENE CHARLIE HALPHEN - INDUSTRIAL HYGIENE JOHN MCBRIDE - SAFETY THE ATTACHED NOISE SURVEYS WERE MADE BY MONITORING EMPLOYEES WITH BRUEL & KJAER TYPE 4431 DOSIMETERS TO DETERMINE NOISE EXPOSURES DURING THE NORMAL WORK DAY. 100% REPRESENTS MAXIMUM ALLOWABLE EXPOSURE, EQUIVALENT TO 85 DECIBELS (DBA) FOR A DURATION OF 8 HOURS. DUE TO INCREASED WORK LOAD AND THEREFORE MORE NOISE EXPOSURE, NEW METHODS HAVE BEEN IMPLEMENTED TO REDUCE EMPLOYEE EXPOSURE. ATTENTION HAS BEEN GIVEN TO PROBLEM AREAS, POSITIVE ACTION HAS BEEN TAKEN, AND MUCH PROGRESS HAS BEEN MADE IN NOISE CONTROL. IT IS THE RESPONSIBILITY OF SUPERVISION TO ENFORCE THE WEARING OF PROPER HEARING PROTECTION BY ALL PERSONNEL DURING NOISY OPERATIONS. J. L. MOREAU, JR. INDUSTRIAL HYGIENE SPECIALIST RAILROAD/MARINE DEPTS. Irj CC: BULLETIN BOARD - RAILROAD " " - TANK CAR CLEANING AN OPERATING UNIT OF THE DOW CHEMICAL COMPANY DO 087908 CONFIDENTIAL. RAILROAD SWITCHING CREW DATE 7/9 H If !l 7/9 It ft If 7/11 It ft 7/11 1? ft 7/12 1? u DOSIMETER # 839610 839611 839609 839608 839610 839611 839609 839608 839610 839608 839611 839608 839611 839610 839611 839608 839610 NAME JOB J. DUNN FOREMAN R. CHEMIN PIN PULLER D. WELLS FIELDMAN L. PUGH ENGR. K. DAIGLE FOREMAN C. NEW PIN PULLER J. RICHARD FIELDMAN L. JACKSON ENGR. L. PARAULT FIELDMAN C. MATTHEWS FOREMAN T. DENTON ENGR. J. QUEBEDEAUX ENGR. D. DUGAS FOREMAN R. FALLIN PIN PULLER L. PARAULT PIN PULLER P. POLITZ FOREMAN T. DENTON ENGR. DURATION 700AM-300PM t It It 715FM-305AM ft It n 700AM-300PM tf 740PM-215AM tl It 700AM-300PM tt It .7 ALLOWABLE EXPOSURE 104 106 30 97 72 99 41 120 44 26 99 103 50 54 89 26 127 CONCLUSION: RADIO EQUIPPED HEAD SET HEARING PROTECTORS HAVE BEEN ORDERED AND . WILL BE WORN BY ENGINEER. RADIO EQUIPPED EAR PLUG TYPE HEARING PROTECTORS HAVE BEEN ORDERED AND WILL BE WORN BY SWITCHMEN. THESE HAVE BEEN TESTED IN THE FIELD AND PROVEN EFFECTIVE AND CONVENIENT FOR THIS OPERATION. AS IN PREVIOUS NOISE SURVEYS, IT IS STILL RECOMMENDED THAT HEARING PROTECTION BE WORN BY ANYONE RIDING FRONT OF ENGINE WHEN HORN IS BLOWING AND ALSO IN OTHER AREAS OF HIGH NOISE LEVELS. DO 087909 GONFTDENTTAl TANK CAR CLEANING DATE 9/10 fl ft 91 9/11 99 ft 99 9/12 99 19 9/13 |l 99 19 9/16. 99 " DOSIMETER # NAME ' JOB 839608 KEVIN ENNIS LABORER 839609 H. WALKER 839610 ERNEST DOMINIQUE " 839611 W. LAYNES 839608 H. WALKER 839609 K, ENNIS " 839610 W. LAYNES " 839611 ERNEST DOMINIQUE " 839608 L. JACKSON 839609 W. JOHNSON 839610 M. OSBORNE 839608 EDWARD DOMINIQUE " 839609 W. EDWARDS " 839610 W. LAYNES " 839611 839609 ERNEST DOMINIQUE " W. JOHNSON 839610 839611 W. LAYNES ERNEST DOMINIQUE " DURATION 730AM-300PM It II II 715AM-300PM IT IT 1 730PM-300AM It II 715AM-315PM It II " 700PM-300AM IT TT % ALLOWABLE EXPOSURE 55 13 9 28 39 86 102 24 51 23 195 30 293 132 35 33 298 50 CONCLUSION: AS IN PREVIOUS NOISE SURVEYS, RECOMMEND CONTINUED WEARING OF HEARING PROTECTION WHEN EXPOSED TO HIGH NOISE LEVELS. EXPOSURES CAN BE REDUCED BY ROTATING EMPLOYEES IN HIGH EXPOSURE JOBS. ENFORCE THE USE OF MUFFLERS WHERE APPLICABLE. 087910 CONFIDENT TAI. RAILROAD TIE TAMPER DATE DOSIMETER # 10/4/85 839608 NAME JOB W OaB- B. PICKERING OPERATOR 7. ALLOWABLE DURATION EXPOSURE 755AM-310PM 26 OUTSIDE- H 839611 F. WHITE ON GROUND It 122 10/9/85 839608 IN CABB. PICKERING OPERATOR 710AM-310PM 31 n 839611 F. WHITE OUTSIDEON GROUND If 122 CONCLUSION: RECOMMEND CONTINUED WEARING OF HEARING PROTECTION BY MAN WORKING ON GROUND WHEN IN CLOSE PROXIMITY TO TAMPER WHEN TAMPER IS OPERATING. DO 087911 CONFIDENTIAL DATE 7/17 It ft 7/18 II It 7/22 tl VI 7/24 tt tl RAILROAD TRACK MAINTENANCE i DOSIMETER # NAME EQUIPMENT OPERATED/JOB ^ALLOWABLE DURATION EXPOSURE 839608 EUGENE VALLERE TRACK WORK 700AM-330PM' 75 839610 LEONARD FIELDS BULLDOZER If 106 839611 SAMUEL MARTIN SPIKE DRIVER VV 251 839608 LEONARD FIELDS TIE PULLER 700AM-330PM 139 839610 HOWARD DUPLECNAIN SPIKE DRIVER IV 227 839611 B. T. WASHINGTON FOREMAN IV 102 839608 FRANK WHITE TIE PULLER 700AM-330PM 71 839610 CARLTON SAM SPIKE DRIVER II 176 839611 GLOSTER MELANCON SPIKE DRIVER VV 156 839608 EUGENE VALLERE TRACK WORK 700AM-330PM 60 839610 B. T. WASHINGTON FOREMAN It 87 839611 HOWARD DUPLECHAIN TRACK WORK tt 75 CONCLUSION: RECOMMEND CONTINUED WEARING OF HEARING PROTECTION WHEN OPERATING OR IN CLOSE PROXIMITY TO HIGH NOISE EQUIPMENT, PARTICULARLY SPIKE DRIVER AND TIE PULLER, AS OUTLINED ON NEXT PAGE. ROTATE EMPLOYEES IN HIGH NOISE LEVEL JOBS TO MINIMIZE EXPOSURE. DO 087912 CONFTOCNTTAl RAILROAD TRACK MAINTENANCE EQUIPMENT RESULTS SHOWN IN DECIBELS INSTRUMENT USED B&K SOUND LEVEL METER TYPE 2219 PORTABLE AIR COMPRESSOR 7/22/85 NORMALLY NO ONE CLOSE AFTER STARTING COMPRESSOR 3 FT. 6 FT. 9 FT. IDLING 92 85 82 UNDER LOAD 96 88 86 SPIKE DRIVER (AIR DRIVEN) 7/18/85 TWO MEN LINING TIES & SETTING SPIKES WITHIN 5-6 FT. OF OPERATOR OPERATOR HEARING ZONE 5 FT. 10 FT. 15 FT. 20 FT. 25 FT. 30 FT. 35 FT. 109 106 103 97 95 92 88 85 TIE PULLER (GAS DRIVEN) 7/24/85 2 OR 3 MEN GUIDING TIES WITHIN 6-8 FT. OF OPERATOR IDLING UNDER LOAD PULLING TIE OPERATOR HEARING ZONE 5 FT. 8 FT. 10 FT. 15 FT. 84 81 77 75 98 94 91 89 85 LIFT TRUCK OPERATOR HEARING ZONE IDLING 76 7/24/85 UNDER LOAD LIFTING 80-87 LABORER DRIVING SPIKES WITH SPIKE MAUL - AT HEARING ZONE 78-84 LABORER SHOVELING ROCK TRACK BALLAST - AT HEARING ZONE 88-92 00 087913