Document 1gM2qq8RnZo1NnRDzq0pbOk7j
I
f 91k ^
I Vj2jJ!
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY
WASHINGTON. D C. 20460
November 25, 1974
Mr. C.L. Stratton, Chief
Technical Services
P.0. Box 13454
University Station
'
Gainesville, Florida 32604
. .
. . .
'
Dear Mr. Stratton:
^
This letter confirms our recent phone conversation and authorizes activity to be undertaken as task I under contract WA-74-R318 entitled "Sampling and Analysis of Selected Toxic Substances." Kindly initiate efforts to develop a sampling and analysis protocol to determine the concentration of PCBs in air, water and soil from samples obtained in the immediate vicinity but not on property owned by the following
industries:
Monsanto Chemical Co.
Krumudge Plant Sauget, Illinois
Manufacturing Co
General Electric Co. Hudson Falls, N.Y. Port Edward, N.Y.
Transformers Capacitors
Yates Manufacturing Co. 1615 West 15th Street Chicago, Illinois
Waxes, Investment Casting Co.
Hitchner Mfg. Co. Milford, N.H.
True Temper Corp. 1623 Euclid Ave. Cleveland, Ohio
Investment Casting Co. O
Investment Casting Co.
Valcast 2741 Elliott Troy, Mich.
Investment Casting Co.
os**10*68
STLCOPCB4076912
-2-
f
Polychlorinated biphenyls (PCBs) are synthetic organic chemicals ' used principally as industrial heat transfer fluids. Their stability
under environmental conditions, propensity for bioconcentration and .. ; i known toxic potential have given rise to substantial concern about
.: : Uncontrolled release into the environment. Despite this long term
.; : regulatory concern, a major question remains to be answered, "Are Voluntary controls established by the industry effectively eliminating
, the environmental release of PCBs known sites of manufacture or use?"
' Hie following guidelines will be considered in establishing
sampling sites.
.
.
Air sampling sites will be established within each quadrant
around the industry. Samples will be taken at an elevation of 3-6 feet
above the ground. Exact sitings will be determined by theoretical
pollutant behavior upon liberation into the environment. Monitoring
euqipment will be placed at the hypothetical point of maximum concentration
in neighborhoods adjacent to the plant. Two consecutive 24 hour
composite samples will be collected from a minimum of 1 site within each
quadrant around the industry. Air samples collected from each site
will be analyzed separately..
.
Surface water sampling sites will be established up and down stream of effluent discharged toy the selected industries. Water sampling will be,concomitant with air sampling and shall employ techniques to insure the integration of horizontal and vertical distribution patterns in the aquatic environment. Two consecutive 24 hour composite samples will be collected at each of the paired sampling sites. If industrial waste is discharged into a sewer system, composite samples will be obtained from that sewer system at a convenient point closest
to the property line.
/Samples of the top 1" soil will be collected along_two transects Which bisect the selected industry forming a rightTangle at i:heir
intersect. Each transect shall extend for 1 mile on either side of jthe industry and samples shall be taken at 1/4 mile intervals.
Sample preservation and detection shall be specific for the .
polychlorinated biphenyls and sensitive to environmental levels of
one (1) ppb.
'
If precipitation can be collected during the sampling period, analysis shall be performed on this matrix.
The protocol for sampling and analysis of PCBs shall be completed within thirty (30) days of the receipt of this letter and submitted for approval by the Project Officer. The report shall contain a detailed statement of the methodology employed and the rationale for selection of specific sampling locations.
OS***0169
STLCOPCB4076913
#
/
DSW 330270 STLCOPCB4076914
STLCOPCB4076915