Document 1aMOd2w485orE8Nqq9J8GzBE
46C.O-Safety-Asbestos Air Monitoring Results
PLAINTIFF'S EXHIBIT
Dallas, May /< , 1991
L ,, vu iiw/'ii revu-i... O0tc
(k.d stamp denotes file copy.)
DISTRICT MANAGER-ARCHITECTURE & BUILDING OPERATIONS - San Antonio: DISTRICT MANAGER-ARCHITECTURE & BUILDING OPERATIONS - Houston: DISTRICT MANAGER-ARCHITECTURE & BUILDING OPERATIONS - Dallas:
Attached are asbestos air monitoring results through April, 1991.
--
All buildings with asbestos surveys completed and having "friable" asbestos are presently being monitored semi-annually (see attached). Please forward a copy of these results to the appropriate building manager.
I* you have any questions, feel free to call or contact Joey Grubbs, Manager-Safety, on 214 464-8652.
.1
Judy McCallum
ristrict K`anager-Human Resources
Attachment
Operations Staff DM-Human Resources
004785
Asiest: C**59. *icr:r. 'eiii
Bldg LOC
Address
Mgr "e! Mo.
Sched.
COUP. X AsP
1. Ati'ene Orchard XF4075 356 Cypress
AddiSon744263
14653 Oils rkiy
3. Aiiarillt To" XF2124 3120 Eddy
4, Arlington Coin 738143 303 110th
5. Arlington East T30G33 400 1. South
5. 3ig Spring XP473G
501 Funnels
( 5o,ia 735521
310 l. Tarrant
5. Oil las Connors 743072 1446 Connors
3. Dallas Mockingbird T44103 5331 E Mcckmgbird
10. Dallas 3 5611744205
505 5. Akard
11. Dallas Khiunall 743175 214 H. 5th
*2. El Faso Mam XAC030 13. El Faso Plant XAGG8G
510 Te*as 11253 Pelllcino
14. ElFaso Southeast XA0040 5045 Srens
15. Ft. Worth Edison 734531 1116 Houston
15. Ft. north lest 135143 3501 3.1. Loop 320
1?. Grand Prairie 743020 1425 Siall
13. Hillsboro XF3405
215 E. Franklin
15. Hurst 730215
1240 Park Place
30. Lubbock XF5505
1405 item
21. McKinney 735552
307 K. Kentucky
2. Midland <F5511
410 M. Missouri
23. Odessa XP2400
801 M. Lincoln
25. Semnoie XF4345
307 5.1. 3rd
25. 7yler 733525
611 1. El*
25. Waco XF2317
325 Mashington
21. Wichita Fails 735510 352 5th st
23. icharasort 746005
200 E. T.ler
23. Dallas 4 Bell 741080 311 3. Akard
30. Grand Prairie 641 743013 2513 Sfterian
31. Dallas 7alor 745555 4211 Bryan
32. Dallas (ianoton 743014 2301 3. Hanoton
33. Dallas E*erscnT46G6: 3643 Hillcrest
34. Arlington '274J 730065 312 4. Apra*
35. Dallas Melrose '*4033 750 Mocningbiro
35. Dallas East 743125
1130 Seachvie,
37. Dallas K. u1st Oft 745D55 1500 srestcn Forest
33. E: Paso Hacienda
7345 Parrel
Elascyk Carranco Sanoai1 Hunter Hunter
Causey Foss Foss Hoge Garra Foss HaraOie Marable MaraPle McCloud Barron Thornshurg Hansen Fiy 31lions Goodian
Causey Causey Causey Tenpenny
Thoias Henry Dosier Soloion Thornshurg Hogue Thornshurg Hogue Hunter Carranco Dosier Cosier Haraole
515-675-3073 214-344-6041 506-373-0455 317-453-5461 617-453-5451 315-534-153: 214-544-6041 214-544-5041 214-464-7517 214-464-4373 214-544-5041 315-542-4574 515-542-4674 315-542-4674 117-333-6033 317-333-5643 214-544-6517
214-544-3150 317-338-5656 306-741-6250 214-457-2020 315-534-1635 515-634-1635 315-534-1835 214-531-3430
817-757-7511 817-766-7182 214-484-7517 214-464-3071 214-344*6517 214-464-731? 214-344-6517 214-464-751? 317-453-5451 214-544-6041 214-464-7517 214-454-731? 315-542-4674
06/51-12/31 02/31-03/51 03/51-05/31 04/31-10/51 04/31-10/51
05,31-12/3; 05/31-11/51 04/51-1C/31 04/51-10*51 02/51-03/31 ' 03/31-03/31 05/31-12/31 06/31-12/31 35/31-12/31 82/31-08/31 02/51-08/31 04/51-10/31 05/51-11/51 04/31-10/31 06/51-12-31 02/51-08/31 32/51-03/51 32/31/08/31 36/51-12/31 02/51-03/51 05/31-11/31' 05/31-11/51 02/51-03/31 02/51-03/51 02/51-03/51 02/51-03/31 02/31-03/51 02/31-05/51 32/31-08/51 02/31-08/51 32/31-33/31 03/31-05/31 06 - 51-12/31
02;05/51 02/14/31
04/22/51 04/24/31 02/23/51 03/05/51
03/04/51 uu'Auft /*ft\* 04/30/31
04/25/51
03/81/31 02/20/51 02/20/51
02/25/31 03/06/31 02/21/51 02/27/5! 02/15/51 02.-14/31
82.-.3t Dj;06. 3` 03/07/51
'.235 .005
. 005 ..005 .033 .005
.805 .322 <004
.006
.008 .005 .006
1.005 .005 .003 ,.005 i.305 :.005
, ll*
. J3:
ASteStOS 4ir asBO'Uig; South Te/dS
Sldg Lot
Address
Hgr Tel Ho.
Sched.
Cone. x asp
T. SA CdDitoI
105 Aud Oir
b: $A 4*13 Braad.ay 415021 4115 Broadid)
rl. SA Pershing 412030
110 Varner
Sutmrez Jennings Enbry
512-226-4524 05,31-11/31 512-320-5712 05,31-11/31 512-320-5332 05/31-11/51
A. ACS Sm.ood 4F2530
305 Colorado
Benavides 512-570-2315 05/31-11/31
5. Alio Hickory Ar2535
201 Cunher'ano Benevadies 512-370-2315 05/51-11/31
5. AOS Hoiestedd AP3510 ( . 00 Tulip 412080
3`T H. Loos
ill liaison 312-870-2433 05/31-11/3!
406 K. Caranchua Hon roe 512-881-7330 03/51-05/51
5. Seguin XI3055
4ua o. mer
Carlian 512-370-2300 05/31-11/3!
3. Broinstille 412045
736 E. Haddington Lopez
512-421-7134 04/31-10/31
15. Victoria 414205
205 rt. Bridge House 312-575-3427 03/51-03/3!
n. Sen Benito 412056
251 Reagan
Lope: 512-421-7134 03/31-03/31
12. Hoy Ham 445i02
3100 Ham
Hernandez 713-521-7403 33/31-35/31
13. Harlingen 412051
401 E. Van Suren Lopez
512-421-7134 04/31-10/31
U. Houston CdDitoI WK57C+ 1121 Capitol
Brandenburg 713-520-0633 05/51-11/31
15. Houston O'd) 442313
1200 Olay
Brandenburg 713-520-063! 05/31-11/51
16. HOuStOfi JaCkSOn 44606: 1310 Richiond
Brandenburg 713-520-0638 05/51-11/31
IT. Houston Kiss ion 443110 <a*i uOOnn
Aragon 713-320-4374 04/51-10/31
13. Houston Kational'436052 2310 Vest Lane Sohr
713-521-0252 04/51-10/3!
15. Houston effort 473060 710 Serry
Vi Ison 713-353-4813 05/31-11/51
25. Houston r1uB Creek 444001 2522 rlui Creek Aragon 713-320-4974 04/31-10/5!
21. Houston ialnut 447130 3745 Harnsfiurg Brandenburg 713-520-0833 05/51-11/31
22. Klein Adiin Bldg. 4L7054 7533 Spring Cypress koiaginezak 713-443-3113 04/31-10/51
23.- Orange 4Z7270
704 4. Eli
Latino 403-335-6105 04/31-10/51
24. Houston 4esidrdn 436431 3303 Veslayan
Gohr
713-521-0252 04/51-10/31
25. 0ai*eston 445155
322 25th St.
Quiroga 405-763-7750 04/51-10/31
25. Houston Hedical 432184 7330 Fannin
Hofstetter 713-750-7626 04/31-10/51
27. Houston Prescott 437015 8303 Brae Acres Wilson 713-363-4813 03/31-03/31
23. Beduiiorit 423125
220 Ham
Latino 403-533-6106 03/31-03/31
23. Houston Apollo 4430*2 623 El Dorado
Faspua 713-336-3145 03/31-03/31
30. Beet 11'e 433034
300 Corpus Christ! House
='2-576-3427 03/31-33,31
31. Houston Sunset 435012 2533 Fonoren
Wilson 713-663-4313 03/31-03/31
32. 3ELLVILLE 433034
`04 4, LtiBN
Holly 713-521-6132 05/31-11-51
33. Liberty
520 Fannin St. Hiuerson 403-231-3436 05/31-11*31
34. Tdr'or
SCO Tatbut
Brignan 12-341-0:33 05/31-11/31
35. Cc'udOuS
1213 Austin
Holley 713-521-6132 05/31-11/31
35. Houston ffeoub < ic
3301 Jutland
Aragon 713-520-437* 54,31-:0/31
37. Haller
1313 Siith
Holley 713-62*-6182 05/31-11/31
33. Brenhdi A 4 Eagle Lake
206 H. Saylor 302 4. Ham
Holley Holley
713-521-6152 :s/si-ii/s; 713-521-6132 05/31-11/31
40. 3A 4et*ore 454 office 17213 San Pedro
34/03/51
04/25/31 04/25/31 04/25/51
04/25/3!
02/01/31 02/25/51
33/01/3! 04/16/31 04/02/31 04/08/31 04/13/9! 02/21/31 02/26/31 34/02/31 02/27/31 04/03/31 32/25:31
'.003
'..003 -.002 *'.005
.005
:.004 .004
7.004 ,004 .004 .004 .003 <.004 i.004 :.304 .005 :.3C3 ..004
004787
SwL
SOUTHWESTERN LABORATORY INC
Construction materials testing, analytical chemistry and geotechnical engineering P.0. Box 224227 2575 Lone Star Drive Dallas, Texas 75222 214/631-2700
May 1, 1991_____________File No.
Report of: Reported to:
Air Monitoring
Southwestern Bell Attn: Joey Grubbs One Bell Plaza, Room 910 Dallas, Texas 75202
Date received: Identification:
4/30/91 1423 Small Street, Grand Prairie, Texas
On April 30, 1991 a representative from Southwestern Laboratories Inc., (SwL) was at the Southwestern Bell Facility located at 1423 Small St. in Grand Prairie, Texas to provide prevalent air monitoring during normal work activities. The results of the air samples collected are as follows:
Sample No.
043091 SWB 01
Location Field Blank
Volume (L)
Fibers per GC <0.0/100 fids.
043091 SWB 02
Field Blank
<1.0/100 fids.
043091 SWB 03
Chief Switchman's Office
1200
<0.004
043091 SWB 04
043091 SWB 05
1st Floor, Switchroom
2nd Floor Switchroom, West Side
1200 1240
<0.004 <0.004
043091 SWB 06
Basement, Boiler Room
1200
<0.004
043091 SWB 07
2nd Floor Switchroom. East Side
1200
<0.004
004788
Lab. No. D9104282
.l {
Samples are discarded 30 days after reports are mailed unless priorarrangements are made in writing. A storage fee will apply on samples held over 30 days.
Our letters and reports are for the exclusive use of the client to whom they are addressed. The use of our name must receive our prior written approval Our letters and reports apply to the sample tested and/or inspected, and are not necessarily indicative of the qualities of apparently identical or similar products.
SOUTHWESTERN LABORATORIES, INC.
Report of:
Air Monitoring
Reported to: Page ^ Qf
Southwestern Bell
2 1423 Small St., Grand Prairie, Texas
Sample No.
043091 SWB 08
043091 SWB 09
043091 SWB 10
Location
Basement, Breakroom
1st Floor Switchroom, East Side
Basement, South End
Volume (L) 1270 1230 1200
Fibers i <0.004 <0.004 <0.004
Method: Analyst:
NIOSH 7400 DP
Distribution of report:
Respectfully submitted,
1C: Southwestern Bell
SOUTHWESTERN LABORATORIES, INC. Per: /fa#
Bob Garrett, Manager
Environmental and Analytical Service Lab. No. D9104282
Samples are discarded 30 diys after reports are milled unless prftSr arrangements ire made in writing. A storage fee will apply on samples held over 30 days.
Our letters and reports are for the exclusive use of the client to whom they are addressed. The use of our name must receive our prior writien approval. Our letters and reports apply to the sample tested and/or inspected, and are not necessarily indicative of the qualities of apparently identical or similar products.
Xl
004789
SwL
SOUTHWESTERN LABORATORIES
Materials, environmental and geotechnical engineering, nondestructive, metallurgical and analytical services
P.0. Box 224227 2575 ton* Star Drive Dallas, Texas 75222 214/631-2700
Date: Report of: Reported to:
April 30, 1991
Air Monitoring
Southwestern Bell Telephone Attention: Mr. Joey Grubbs One Bell Plaza, Room 910 Dallas, Texas 75202
Date received: 4/25/91
Identification: 1240 Park Place, Hurst, TX
On April 25, 1990 a representative from Southwestern Laboratories Inc., (SwL) was at the Southwestern Bell facility located at 1240 Park Place in Hurst, Texas to provide prevalent air monitoring during normal work activities. The results of the air samples collected are as follows:
Sample No.
SUB-01 042591
Location Field blank
Sotefi--(L).
Fibers per CC . 2.0/100 fids.
SUB-02 042591
SWB-03 042591
SUB-04 042591
Field Blank Breakroom Mid Cities Maintenance Center
1200 1200
0.0/100 fids. 0.006 <0.004
SUB-05 042591
Directory Assistance Operator area
1200
<0.004
SUB-06 042591
SUB-07 042591
Waiting Room NDS Conference Room
1200 1200
<0.004 <0.004
Method: NIOSH 7400 Analyst: DP
Respectfully submitted,
SOUTHWESTERN LABORATORIES, INC.
Lab No. D-9104245
Bob Garrett, Manager Environmental and Analytical Services
004790
S/L
SOUTHWESTERN LABORATORIES
Materials, environmental and geotechnical engineering, nondestructive, metallurgical and analytical services
P.0. Box 224227 257S Lon* Star Oriv* Dallas, T*xas 75222 214/631-2700
Date: Report of: Reported to:
March 20, .1991
Air Monitoring
Southwestern Bell Telephone Attention: Mr. Joey Grubbs One Bell Plaza, Room 910 Dallas, Texas 75202
Date received: 2/22/91
Identification : 3901 S. W. Loop 820, Fort Worth, Texas
Samole No.
SWB-01 022291
Location Field blank
folMt (L)
SWB-02 022291
Field blank
SWB-03 022291
Basement, breakroom
1150
SWB-04 022291
Basement, mechanical room
1200
SWB-05 022291
Basement, boiler room
1200
SWB-06 022291
Basement, air handler room
1083
SWB-07 022291
1st floor, billing office
1370
SWB-08 022291
2nd floor, air handler room
1026
SWB-09 022291
1st floor, breakroom
1150
Fibers per GG 2.0/100 fids. 1.0/100 fids. 0.007 0.008
<0.004 0.005 0.009 0.016 0.008
Lab No. D-9102182
004791
SOUTHWESTERN LABORATORIES, INC
Report of:
Reported to: 2
Page.____ of
Air Monitoring Southwestern Bell Telephone 2
Sample No.
Location
Volume CD
SWB-10 022291
2nd floor, new order business office
1100
SWB-11 022291
Air Handling Room
1000
SWB-12 022691
Second floor, air handler room
1026
SUB-13 022691
Second floor, new orders business office
1000
Fibers, per GC 0.022
<0.005 * *
These two samples were analyzed by Transmission Electron Microscopy. These two samples were recollected and analyzed due to the previous results obtained on February 22, 1991. No asbestos structures were observed on these samples.
Method: NIOSH 7400 Analyst: DP
Respectfully submitted,
SOUTHWESTERN LABORATORIES, INC.
/%&
Bob Garrett, Manager
Lab. No.
D-9102182
_ Mkz
Environmental and Analytical Services
Simples are discarded 30 days after reports are mailed unless prior arrangements are made in writing, A storage fee will apply on samples held over 30 days
Our letters and reports are for the exclusive use of the client to whom they are addressed. The use of our name must receive our prior written apprv*i- Our
letters and reports apply to the sample tested and/or inspected, and are not necessarily indicative of the qualities of apparently identical or similar prooucts.
114 004792
S<L
SOUTHWESTERN LABORATORIES
Materials, environmental and geotechnical engineering, nondestructive, metallurgical and analytical services
p.O. Box 224227 2573 Lon Star Driv* Dallas, Texas 75222 214/631-2700
Date: Report of: Reported to:
February 27, 1991
Air Monitoring
Southwestern Bell Telephone Attention: Mr. Joey Grubbs One Bell Plaza, Room 910 Dallas, Texas 75202
Date received: 2/21/91
Identification:: 2513 Sherman, Grand Prairie, Texas
Sample No.
Location
Volume (LI
Fibers per CC
SWB-01 022191
SWB-02 022191
SWB-03 022191
Field blank Field blank Basement, mechanical room
1050
2.0/100 fids. 3.0/100 fids. <0.005
SWB-04 022191
Basement, Lounge area
1050
0.008
SWB-05 022191
1st floor, Switch room
1150
<0.004
SWB-06 022191
1st floor. Room 103
1200
<0.004
SWB-07 022191
1st floor, Air handler room
1200
<0.004
SWB-08 022191
2nd floor, Business office
1000
<0.005
SWB-09 022191
2nd floor, Lounge area
1000
<0.005
Method: NIOSH 7400 Analyst: DP
Respectfully submitted,
SOUTHWESTERN LABORATORIES, INC.
Lab No. D-9102175
Bob Garrett, Manager kz Environmental and Analytical Services
004793
SOUTHWESTERN LABORATORIES
PREVALENT AIR MONITORING FOR
1116 HOUSTON STREET FORT FORTH, TEXAS
FOR
SOUTHWESTERN BELL TELEPHONE ONE BELL PLAZA
DALLAS, TEXAS 75202
Prepared by Southwestern Laboratories, Inc.
2575 Lone Star Drive Dallas,Texas 75212
ISoI 0c6 Tic:ON 131
IH'l' 1P1S
;QI C.S :?I
It `
004794
OUTHWBST6RN LASONATOniSH
TABLE OF CONTENTS
SECTION 1: SECTION 2:
REPORT PREVALENT AIR SAMPLE RESULTS
ZOd 1
TbST 036 FT3:QN "131
004795
Ihq. ms
:.2I ,,:?! HH1 To.-lC'-dTl;
SECTION 1:
REPORT
ilia
T68T 0?b ric:ON 1H1
"M `ins
004796
:ai 6 ='?T HH1 Ib.-wO-d^U
outhwebtebn laboratorih
PREVALENT AIR MONITORING for
Southwestern Bell Telephone ' One Bell Plaza, Room 910
Bellas, Texes
INTRODUCTION
Prevalent level air monitoring for Southwestern Bell Telephone is designed to evaluate the existing air quelicy in the area sampled in the building located et 601 N. Lincoln, Odessa, Texas. Air monitoring was conducted to establish prevalent fiber levels in the building. The procedure used to evaluate the air samples collected is an established procedure developed by NIOSH.
PROCEDURES
Prevalent level air monitoring was performed in accordance with procedures contained in the National Institute for Occupational Safety and Health's (NIOSH) "Manual of Analytical Methods, Third Edition, Method No. 7400", and recommendations contained in "Guidance for Controlling Asbestos-Containing Materials in Buildings", EPA 560/585-024, June, 1985. The analyses were performed by Phase Contrast Microscopy (PCM).
Prevalent Level air samples were obtained by means of high flow sample pumps equipped with a critical orifice to control air flow rate. Samples were collected on open faced cassettes containing 25 millimeter (mm) diameter cellulose ester membrane filters equipped with extension cowls. The high flow rate samplers (10 liters per minute) were utilized to enable a large volume of air to be sampled within the designated sample period, thus yielding a lower reliable quantitation limit.
The pump/filter arrangement enabled SwL to achieve a Reliable Quantitation Limit of 0.005 fibers per cubic centimeter of air sampled. "Aggressive Sampling" (as contained in the aforementioned E?A Guidance document) was not utilized during this test program, however, normal air flow from air conditioning units was not restricted.
The sampling protocol followed was designed to test at least 502 of the building (ie: one-half of the total number of floors). In addition, air samples were collected in areas where previous abatement had occurred or potentially damaged ACM was located.
&Jd ilbft
T68I 0S6
:QN 131
1W. IMS
004797
:<1I S3:ST flHl 18.
ouTHWESTeniu uABonATontea
At the conclusion of the sampling periods, each filter was sealed and carefully labeled. . The air samples obtained and the blank filters were submitted to SwL's accredited laboratory in Dallas, Texas, for analysis utilizing Phase Contrast Microscopy (PCM) at 400 X magnification by an analyst who has completed the NIOSH (582) training course for evaluation of airborne asbestos dust. SwL participates in the Proficiency Analytical Testing (PAT) program for airborne asbestos by PCM, sponsored by NIOSH. The PCM technique (utilizing NIOSH methods) does not distinguish asbestos fibers from other fibrous particulate (ie. fiberglass, cellulose).
RESULTS
Prevalent level air monitoring results are shown on the attached reports.
Initial analysis of sample SWB-14 (15th floor air handler room) yielded results greater than 0,01 fibers/cubic centimeter. This area and the office area which is serviced by this air handler, were resampled on 3-4-91. All of the samples collected on 3-4-91 yielded results below 0.01 fibers/cubic centimeter.
The reason for the initial, aberrantly high value (SWB-14) was found to be the result of a technician sampling error, The sampling cassette fell to the floor in the 15th floor air handler room during sample collection. Asbestos debris was noted (and confirmed by PLM analysis) in the specific area where the sample cassette had fallen. This debris originated from thermal insulation on a chill water pipe. The fiber count for this sample was therefore biased due to fiber contamination from the debris on the floor. This sample was not representative of prevalent level fiber concentrations on the 15th floor office area or air handler room.
LIMITATIONS
The prevalent level asbestos results are representative of their respective sampling period only, and there Is no guarantee that the levels will not change with time and building use.
IbST 0cb tT?:0N 131
IH'l H'lS
:QI
004798
TlHl If.
SECTION 2:
PREVALENT AIR SAMPLE RESULTS
T66T 0c t T c : ON 131
004799
nya'ii'is
. "f T eii'rt flHi T3 .--C-rrl.
Su>L
SOUTHWESTERN LABORATORIES
Matatiah, twiroamntal and gteteckmcal aagiimrm& madextructm, mtaUargieai and analytical nrriett P.0. Bex 214227 2575 lorw Star Drtva alias, Texas 75222 a 214/511-2700
Date: Report of: Reported to:
March 1, 1391
Air Monitoring
Southwestern Bell Telephone Attention: Mr. Joey Grubbs One Bell Plaza, Room 910 Dallas. Texas 75202
Date received: 2/27/91
Identification: 1116 Houston St., Fort Worth, Texas
Sample No,
Location
Volume (L)
SWB-01 022691
Field blank
SWB-02 022691
Field blank
SWB-03 02269 L
Basement, Boiler Room
1000
SUB-04 022691
Basement, Mechanical Room
1010
SWB-05 02269L
1st floor, Switch Room, Air Handler Room
940
S V? - 0 6 022691
1st floor, Switch room column #L9. i
970
SUB-07 022691
2nd floor, Mr handler Room 219
1070
SUB-08 022691
5th floor, Room 538, Special Services
1020
SWB-09 022691
7th floor, 737 Room, Storage Room
1180
SUB-10 022691
9th floor, Emergency Generator Room
1240
SUB-11 022691
ilth floor, Air handler room
1230
HMh.pt cc 0.0/100 fids. 1.0/100 fids. -
<0.005 <0.005 <0.006 <0.005 <0.005 <0.005
0.005 <0.004 <0.004
Lab No. D-9102210 SOd 1681 0S6 rI3:0N 131
nya nns
004800
aI OQ'-Lt fiHl IS .-wO-dfl I
SOUTHWESTERN LSBCIATORiE88 8NC.
Report of: Reported to: Pape ^ of
Air Monitoring Southwestern Bell Telephone 2
SaiRle.3,
SUB-12 022691
SUB-13 022691
SUB-14 022691
SUB-15 022691
SUB-16 022691
SUB-17 022691
foltane (LI 11th floor, #1140, Northwest corner 1110
13th floor, Operators Room
1190
15th floor, Air handler room
1110
14th floor, Air handler north side
12th floor, North-south hallway near Room 1225
8th floor, Office 800
1000 1060 1000
rifr.tTt-Fr S <0.005 0.006 0.040 <0.005 0.005 0.009
Method: NIOSH 7400 Analyse: JG
Respectfully submitted, SOUTHWESTERN LABORATORIES, INC.
004801
Jlw\
Bob Garrett, Manager
Lab. .No.
D-9102210
\}kz
Environmental and Analytical Services
Samples are discarded 30 days after reports are mailtd unleu prior arrangements are made in writing. A storage fa* will apply on samples held over 30 da
Our letters and reports are for the exclusive use of the client to whom they are addressed- The use of our name must receive our prior written approval. (
letters and reports apply to the sample tested and/or inspected, and are not necessarily indicative of the qualities of apparently identical
"
il4 60d
1681 036 RI3J0N 131
nya-'ins
:>3I 00:It PHI 16 .-10-3*711
&tu
SOUTHWESTERN LABORATORIES
Materials, eitrironmental and gtettcknkel tngltmrmg, Madmntctite, mstaMssrgieal and analytical strricst 7.0. Box 224127 2575 Lon* star Orfva Datlaa, Taxaa 75222 214/431*2700
Date: Report o: Reported to:
March 5, 1991
Air Monitoring
Southwestern Bell Telephone Attention: Mr. Joey Grubbs One Bell Plaza, Room 910 Dallas, Texas 75202
Date received: 3/4/91
Identification: 1116 Houston St., Fort Worth, TX
Sample Ho.
Location
Volume ID
SWB-01 030291
Field blank
SWB-02 030291
Field blank
SUB-03 030291
Room 1502
1545
SUB-05 030291
SUB-07 030291
Room 1509 Room 1508
1017 1607
SUB-09 030291
Room 1510
1587
SUB-11 030291
Room 1506
1779
SUB-13 030291
Conference Room, Room 1514
1647
SUB-15 030291
Hallway near Room 1508
1515
yifrra pey CC 1.0/100 fids. 0.0/100 fids.
<0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003
Lab No. D-9102210
Old S4SB
T63T 036 VISION 13J
lyil/ins
004802
TO:,:! OHl T 6..-="
SOUTHWESTERN! LABORATORIES INC,
Report of: Air Monitoring
Reported to: Southw*tern Bell Telephone
_L of 2
^ MsMiisn
MfflliU
Zttin per cc
SWB-17 030291
SWB-X9 030291
Supply Room near Room 1509 15th floor, Air Handler Room
1312 1638
<0.004 0.005
Method: NIOSH 7400 Analyst; DP
Respectfully submitted,
SOUTHWESTERN LABORATORIES, INC.
004803
Bob Garrett, Manager
Environmental and Analytical Services
Sample* ar* discarded 30 day* after report? are mailed unleaj prior arrangements are made in writing A storage fee will apply on samples held wet 30 days.
Our letters ind reporti are for the exciisive uie of the client to whom they are addressed. The ute of our name muit receive our pnor written approval Our tetters end reports epply to the sample tttted and/or inspected, and are not necessarily indicative of the qualities of apparently identical or similir producti.
114
TTd S4S8
T6ST 036 813:014 131
iua nns '31 I0:j.T nHl T