Pumps
CHICAGO PUMP COMPANY
SEWAGE-CONDENSATION-CIRCULATING BILGE- FIRE-HO USE-VACUUM
2330 Wolfram Street - BRUnswick 4110 - Chicago
PRODUCTS--Vacuum and Boiler Feed Pumps, Condensation,
House, Booster, Fire Pumps, Circulating, Brine, Sewage,
Bilge, Sludge, Pneumatic Tankless Water Systems and
Automatic Alternator.
>
WE DO OUS MKT
Condensation Pump and Receiver for Low; Medium and High Pressures
Systems up to 150,000 Sq. Ft. Radiation
"Sure-Retum" Condensation Pump
for Low and Medium Pressure, and Systems up to 35,000 Sq. Ft. Radiation
Fig. 1946
Fig. 1931--F. C Condonation Pump
"Chicago1' Condensation Pumps are built for systems ranging from 2,000 up to 150,000 sq. ft. of radiation, and for boiler pressures up to 200 lbs. Units are built in either single or duplex--the duplex being alternated in their operation by the Automatic Alternator. For tables and com plete description ask for Bulletin 129.
Vertical Condensation Pump
for Low and Medium Pressure for Systems up to 100.000 Sq. Ft. Radiation
The vertical condensation pump is designed to re ceive returns from lowest radiation. The receiver is placed underground--an ordinary hole sufficing if necessary -- and requires very little floor space. Unit is shipped complete, easy to install, assembled so as to prevent steam leaks. Special bearings will stand up under hot water for several years. A special float mechanism is guaranteed not to leak or stick in stuffing box. Complete data and descrip tion in Bulletin 138.
"Sure Return" Condensation Pumps and Receivers are built for systems up to* 35,000 sq. ft. of direct radiation and for low and medium pressures. Built in either single or duplex units. Duplex units are alternated in their operation by the Auto matic Alternator. Complete data in Bulle tin 131.
Horizontally Split Pumps for all Services
Fig. 1831--Single Stage Type "D" Pump
For any service (such as boiler feed, water supply, tank filling, circulating, fire protectipn, etc.). Chicago Pump Co. builds a line of horizontally split case centrifugal pumps in both single and multistages. Completely bronze fitted (except where special fittings are required) ball bearings, internal water seal, oil is filtered. "Chicago" Horizontal Pumps are built for efficient performance and long life.
728
Chicago Pump Company
"CONDO-VAC"
Return Line Vacuum and Boiler Feed Pump
Pumps
Automatic Alternator is available on Duplex Return Line Vacuum
and Boiler Feed Pumps
"Sure Return" Engineering Table
Maximum square feet direct radiation
1
Pounds pressurepump w ill discharge against Horse power motor furnished Size of discharge in inches Size of return inlet in inches ' Capacity of pump in gallons per minute Capacity of receiver in gallons Height of inlet in receiver from floor level in inches 1 Approximate shipping I ) weight--Single 11
6 Z
5
8 -SR602 2,000 10
SR604 27
SR606
50
SR609 4,000 10
SR611 SR613
8
21 50
SR6I6 6,000 10
SR6I8 *
18
SR620 * 50
SR623 SR625
SR627 SR629
SR631 SR633
8,000
*
*
"
10 17 17
22 29 35
SR636
SR638 SR640 SR642
1.0,000 "
SR644 5R646
"
10
15 16
21 29
35
SR651 SR653
SR655 SR657 SR659
15,0. 00 " "
10
17 20 28
34
SR662 SR664
SR666
SR668
20,"000 *. *
SR670
10
16 19
26 33
SR673 SR675
25,"000
SR677 SR679
SR68I
"
(0 15 18 25
30
SR684 35,000 SR666 SR688
SR689
12 15
22 27
8v. 1
Vi 1
2
.
:
3 8-
186 .
a Vt
21V? 300 350 400
v. 1
A1
28
68
186
2l'/2
300 350
A Vt
400
A1 A1
28
9 8
`/a Vt
m
16 21V? 300 8 350 " 425
12
1 AVt tv.
2.
1 IV.
"
*
8888
"
182 189
88 88
88 *
23
88"
8
300
350 3/5 400
500 525
Vi A A
1 IV? 2
1 1
>A
" 8
28 88 8
185 189 88 88 "8
283 88 "
350 400
425 450
550 5/5
Z%z
1 IV? 2
IV.
8
8
8388
28881
. 5"89
8
"
3880
" "
450 510
550 650 675
AA IV,
1
IV,. 2
8 8
3
8
380 5"9 8
3"0 8 8
475 510
550 650 675
AA
IV,
38 8
IV? 2
8
8
385 59 8 8
380 88
475 510 550 650 675
Vt 1 3 50 59 30 510
8\ "
550
8 8IV? 650
2 675
Units marked with asterisk run at 17S0 R.P.M. All other units listed on this sheet run at 3500 R.P.M.
729
Fig.-tWO--Single "Condo-Vac" _ .
No vacuum on stuffing boxes,, ample clearance in rotating member. It costs less to operate a Condo-Vac. CondoVac reduces corrosion in piping and boiler to minimum--because pump does not take in air from atmosphere and entirely eliminates all air coming back from system. Condo-Vac is quiet, has a low inlet, entirely automatic, fool-proof, easy to maintain. Ask forBulletin 137, learn more about the modern vacuum pump with the long life principle of operation.
"Condo-Vac" Engineering Table
Single Standard Capacity, with Double Automatic Control and Receiver. 20 Pounds Discharge Pressure
Simultaneous Water and
Saturated Air Capacity at
160 F
Square Feet Direct Radiation Horsepower of Motor Furnished Capacity for Water only, at 160 F. GPM Water GPM AirCFM I
at 5 '// !
Pump Discharge in Inches Approxinate Shipping Weight in Pounds
2,500 '/2 3.8 *5,000 Vt 7.5
10,000 !
15.0
15,000 l'/2 22.5
20,000 2 . 30.0
25,000 2 37.5
30,000 3 45.0
40,000 5 60.0
65,000 7V? 97.5
100,000 10 150.0
150.000 15 225.0
1.3 2.5 5.0
7.5 10.0
12.5 15.0
20.0
32.5 50.0 75.0
1.3 2.5 4.0 5.4 6.8 8.3 9.7 12.6 19.8 30.0 50.0
>/. .500 525
8` 550 8 1,000
74r 1,200 1,300
" . 1,450 2 1,700 ' 8 ' 2,200
83 3.000 . 4.000
Vertical Style Condo-Vac (Fig. 2120) operating at 3500 R.P.M.