Document 1QgeQ9gG6D25wxyM6aGV7XGwq

r-?.::,: james e. hines INGOT CASTING DIVISION ALCOA TECHNICAL CENTER - B TO MEMORANDUM 1979-11-08 DATA LETTER RE: ASBESTOS-FREE MOLTEN ALUMINUM BACKUP INSULATIONS Summary As part of Pittsburgh Mechanical Engineering Division--Furnace Section's and AL Ingot Casting Division's program to better design and construct furnaces and metal transfer equipment, a study was made to find acceptable asbestos-free insulating backup materials to refractories in contact with molten aluminum. Since each application must be considered individually as to the proper amount and type of insulation, this report points out the advantages and limitations of nine commercially available products. Introduction Ref actory insulating materials offer significant advantages in the construction and operation of furnaces and refractory-lined vessels. Proper selection and application of insulation result in important savings of fuel, time, space and weight. In addition, insulation helps maintain close temperature control and contributes to more comfortable working conditions for operators. Savings of fuel is one of the most important reasons for insulating. Heat flows through a wall or roof from an inner hot face to -the outer cold face where it is dissipated and lost by radiation and convection. The amount of heat lost often constitutes a consider able portion of the total heat input required to maintain the desired operating temperature. Such losses would be greatly minimized by building the walls partly or entirely out of hightemperature insulation, either as backing to denser refractories, or when conditions permit, as an inner lining exposed directly to furnace atmospheres. When desirable, the'use of insulation also allows economy of space, weight and time. If used in place of part of an existing dense refractory wall insulation, it may permit thinner walls and the weight of the refractory structure could be significantly reduced. This would permit both a lighter foundation and a lighter furnace superstructure. At a given rate of heat input with available burner capacity, the time required to bring a cold refractory unit to operating temperature depends on the heating capacity of the refractory lining and upon the heat penetrating it. Through the use of insulation, the heat storage capacity is substantially reduced and the time required to bring the unit to temperature could be considerably decreased. APC 003894 Memorandum 1979-11-08 Page 2 When. selecting high-temperature insulation , many' factors,musi te ^ considered. One determining factor;[:when''X'i^ula^i^;:-^!>:used`'f-a^i;;''af backing for a -more refractory' lining-:-materiafcfiS''' the^itterface*' '* temperature. The insulation' obviously must',b$'*-V'"3is, refractory enough at the inteffaca-to'-'Wi|^star^|ti^'J^n^e'ritufe:.:?|t'i!;^;;';', In addition, one must consifd#^'thstmaj.. heat capacity of the working refxictiiiD'ry ;.as vfell^astide^rpctiy^ '........................" ' factors such as duration of heatirigV 'nature 'nbfgjiuiei^^r^ractoiy'^|i;*S;-.j;,'' B -'/ expansion and growth,-'and -fox lowe^ walls* When choosing an insolation-gf6r4a^jmie'lting^r-l;hoi(^Llhg?>iiirnace'i;wliiciv'r1: operates semicontinuously, ^highVlIeatuiatiar^eiih^th^'J^eiracidiii'es^''.- > is a definite benefit because^ofjJitlt!'Cusliioh^fi#^ed^,a|iain^W:;v'^'i:;v^ excessive fluctuations in temperature. The.be^t construction for 'A- i ' * these furnaces jis with, composite-:|wail,s `^^;i^f!^^9hs'istirig*rbf V^X^. , -`J>i den'se refractories- backed with|cpnpreSsibieLM^ ia'-'i-f. ,(6; high furnace temperature <and a high { degree the mean temperature may become higher^,thM`y:that^i^c^thS-<re^rac^.v\;t; tory can withstand. Hence, adding 'ibsuiabi^ntiMyCiIreSua|i^;in^needihg,:`i, a material with higher reiraJctorineisS; arid-iequir^g'fr^^ign^bb^^;.;^: reduce deformation.,/ Therefore, heSt Jsavihgs and other benefits of V - 'V jf'M'* > insulation must be carefully baiahcedagainststhepossibleindreased ' r i ' . I1," . ' -A*.' , - ' 'Sri 1. 11}-L- - ^,1'. I JH'. ` 'Si' -ejiVV f 1 ` i*. " V ! ?. ,i f I|,.' L !' ,.. >. ,* l! costs associated with more rapid upgrading the forking-B-ii$ing*;to * Kigfe4quali-ft^^^ i. , 'V';'' -1, -:'i this type of problem is Xappa56alch<ad;|ln'-*j!^^ , *;+!<!: computerized calculations^ and seie'ction;^^^^^ ^a'-#'- ? t-l*r}\ refractory system -bam -be designed which;; Will give bptimm ;heat , ' < savings and,Service life. [ .> 'f: '*/* ' : (i `7f,' ''X.'Vfn-X i..- - J;/ `..c v. ,`L .*V. Insulation Materials I : .3-*. tiX /- , :r ?: , :4y-'^!-,,LJ-*..u Listed below are the asbestos-free and a brief description of each: finsula`--tvio.* n s; maberiais&e^xaunined^- ,,1 - ' - B,j: fit 41.,!& , A^` Eaqle-Picher PV Supertemp block is composed of mineral wood fibers with specially .prepared^inotgau^^ltoiiidersj^icbi^f^f^}:^ j been one of Alcoa's recommended ^backup insulations for years.;.;. ` Temperature limit is 1040C (1900F); W!- Keene Mono-Block, also a mineral wool- insulatipn',' Ka^liJ^jSy*;;jwhic^;^,l have been I specially '.''inberlock,ed.l:tp ;iigbtw:aigfet^ a*id;^- rigid, yet resilient block. 1040C (1900F). I! ' 1 Temp'>.ey~ ra^ure- like \ipy' ''SupertiexnR''is'< ' i$i\V v T, v-iT.'!'\ - - " ,S,~V ` Jl/ij ^^^r.' /: ' i-'f- ' ^ jr"-' '' lf Keene Delta-T is a felted^:, spun,, ceramic, .clay, --fibers^.pnded'y^ inorganie binders. Temperature ''''limitation il^MgH^ Rim mineral wool,, at 1260 C (23Q0 , |`|v' ; ;.:h <a). r- .1. Products 410-03, a ceramic fiber ------------------------------------------------------------------------- - ' 'r alumina-silica fibers with high -pprubrdituy. c' taHl^uims inmae^ei,Tb yev4.m- b. poenrdaitnugr1e-.t'f:jfV - rating is 1300C (2372F). Thisfinsuiatibh|was mt-o be nonwetting to molten metal, making^thiSi^nsulation-:'/^iy,^, ......,. ti ,7,;, particularly attractive. , , ' ^,'vV-'iiy ; I, ; -^'v> ^ J''*' ,| * ./ : <:; }. i-'i' ' 'V'llly -,- ,(} :', *.' Y -. Memorandum 1979-11-08 Page 3 International Vermiculite IV-19 block insulation is manufactured from vermiculite granules and high-temperature bonding inorganics; like the mineral wool insulations, it is good to 1037C (1900F). International Vermiculite IV-20 block insulation is asbestos-free as are all of these other insulations. IV-20 consists of diatomaceous silica with a hydraulic binder for service to 1093C (2000F). Johns-Manvilie Superex products have been used in combination with Eagle-Picher's PV Supertemp for reverberatory furnaces. A combination of silica, lime, clay and fibers make up these products. Superex 2000, a high-density, low-calcium oxide content block, was designed for low shrinkage and top performance up to 1100C (2000F). Superex 1600, on the other hand, has a high-calcium oxide content and lower density than Superex 2000. This formulation gives better strength and insulating properties for situations where temperatures do not exceed 870C (1600F). Skamol Skamolex PM-10 (formerly Skamolex GX 1000) is also a white calcium-silicate material. This product is distributed by Dolomite Brick Corp. in the United States but manufactured in Denmark. See attached manufacturer sheets for more details. In Table 'I are the chemical analysis and X-ray diffraction data collected for the nine products studied. The purest material is the Rim 410-03 which contains the highest alumina content and is essentially all amorphous. Three insulations--PV Supertemp, Mono-Block, and Delta-T--are montmorillonite (CaMgSiO.) based. Delta-T has the lowest impurities, whereas Fe-O,, MgO and alkali are high for both PV Sumpertemp and Mono-Block. IV-19, as characterized as X-ray diffraction, is largely comprised of talc and silica. IV-20, on the other hand, is identified as a diatomaceous earth composition which has silica and calcite. Cristobalite and alpha quartz forms of silica make up Superex 2000. Superex 1600 and Skamolex PM-10 both are calcium-silicate hydrates. Evaluation and Test Procedure Outside of the compressibility testing, all physical property data were determined using ASTM methods. Bulk Density, linear change, and loss on ignition were all examined. Compression tests were accomplished with a Dillon dynameter. Square samples measuring 50.8 mm (2 inches) were aligned in the Dillon machine and compressed initially to 90% of its original height. (Fibrous materials were positioned so their fibers were perpendicular to the pressing APC 003896 ,Y">'V ; ;) :?$ -/-I. sc v; V .t *'rtv A\f'' M1Y Memorandum 1 1979-11-08 Page 4 'Ar 's f.U -A'?. '.v-r- ...........(3.jJ.c./SCrC;-! direction.) The load was^then'/"-recof. Comp..r.e...s...s..i.o...n... measurements' were continued for every 10% ((deformation up Any fracture or unusual behavior was noted. . v. ,, ..... to,a M-c Ti-r> reduction, of ...... .. \- ,-.j 40%.- . .., ... ..VJIy Corrosion resistance to molten aluminum wasCdei^rmih^%ylAicba^sir(:S C}1 modified B-Immersion test. ./;SimpJtyy.':tii4fs'lt|i^ the sample to 540C (l'P00F>* .jghejv;'immersing length into 7075 alloy at * 7:600C,>'(140b;0,F:)Cfor ^ being cleaned, the percent, -sample weight- regained `i^Sr(tfc(|rdejd'.|-if' If possible and results are warranted, 'taisecbrid.'"cyclef^ieifpierfqrmiBdS -i^r Again, precent [sample, weight retained is^determined;; ayi, ' S >,/ Results `V 'I' it' f"y ' *-( f ^1 *,' \t i - i* . ''if !y'n.<jv I | S .'Vcr yv |! Please refer to Table II.5 for physical property data. .Maximum' recommended service temperatures are recorbed-first. ':'As''':seen, the * higher the temperature' -the* .fewer major drop-off points were at 875C;jY'(<I6^F)|^y?^?e^|^pO:^^Cand; 1320C (2400F) Rim 410-03 had the. highes^'ira^ngl.^ty^lW^'?;^ " (2372F); Deita-T followed at 1275oC i2300"F)s. ; All fthe ptheryi insulations are1' suggested .for >:Jess!'' thanf.lipP 0 'K.f: /; Superex 1600' which is -only rated- atf8I0C V:.` ,I 1' " -.S>b?-.` .Iwli.' If, 1 , ; 1 *c ;$-* >" i'!>> ,v.v,'!* r|' .n Other properties which determine allowable exposure temperatures , include linear [firing 'Shrinkages'^and'^los# on;]];lgnit^ ir measurements, 2i 5 X 2.5 X I5-cm' yi/;';X,'.il X 6ri'iaM),ys^^ " exposed to temperatures of 540C (ibp0F) and 1100?C .(2000.F); - after which they were measured andf^eligHed^yfl^p^bgrapHs^ldlCspnie y of the specimens, after exposure. - V\;\ 540C (1000F) [only slightf;4i.men,ii.brte%;pha^g^M'#^^|^?^^^:i:^:but/ '*' loss on ignitions were high'' for^IV^jlP/^Su^^^x^jl^py^^d^klMab^ex PM-10. (Loss bn ignition measiMemen&sV:giye]^^ weight of chemically bonded water/ :ahd!H^<5a$ibjti^^ * these three materials' .show^ structural' low temperature. At ,:fc- temperature of insulations and Delta-T mreatateinr,iatlhs e'rierm' satirnu']c-rteui^raatli,y] einlyp,eg:uritny'|awff^e%c:vteOcn'5i^^ifR.^^C, 4ipi. rf&P- b!3,;i 1:*v i , " ,,;'f '|;r ,s Crushing strengths, were perforxnedi^"upl'iitb.*ia'';:'d__r_ ij. t 'v v. of 60%. For most backup ihsuiati^ris>;|theYmatbrial|Cshpuild#bb'';yi|pi^:C"^ enough to install- but have a' crushinglsbrength/tb^meetl^re^ac^ry^C^i expansion without bverstre8si<n^.-';ahd|ttlie-f|>xming the,^urn^cb^bu^ide^;,*r shell. Eagle-Pichers's PV Supertemp has:been theperferredmaterial in melting and holding furnace^consjtruc^tipn;.^ It compresses steaaily up to 50% before its strength suddf^y^^'leS'i^At .; the testing did ..the sample,.;fracturel^^^Ker.rin|ui^iphe.;yM9nb-:^:'.',C;; j/ Block, Delta-T, and Rim 410-03) hehaye^|similarly.^)^j^ip^p3>, 1 n; although exhibiting an '"initial ''lower'-letrengtiiy-more.-Iclpseiy^y" resembles the compressibility toft,PV[ Sup<^. jcSf, . insulation. IV-19, IV-20, and Skamolex PMtIO all fractured at n. -i '. 1- ' ` ' f, ' iff ' t4' ,"k' A'% 'Vr!.'-], ' 'rSjv'X ' Memorandum 1979-11-08 Page 5 approximately 34.5 MPa (5,000 psi). The Superex products, although not showing a brittle fracture, had exceedingly high strenghs up to 345.0 MPa (50,000 psi) after only 40% compression, the highest of all insulations. The apparent thermal conductivity of mass insulations is a combination of the following heat transfer mechanisms: thermal conductivity of air, thermal conductivity of the solid components of the insulating structure, the convective heat transfer within the pore structure, the radiation heat transfer within the structure, and the interactions of these mechanisms. The thermal conductivity term itself refers to an intrinsic property of a homogeneous material, but because of these many heat transfer mechanisms it is subject to much theorectical questioning when referring to insulations. For comparison purposes however, the manufacturer's thermal data are given. As shown, the thermal conductivities of all the insulations evaluated are nearly the same. The greatest difference is between IV-20 and PV Supertemp, 0.13 W/m*K (0.89 ^tu*in/h*ft F) compared to 0.10 W/m*K (0.69 Btu-in/h*ft F), respectively. In this regard, the choice of which insulation to use will be dependent upon other factors discussed. In many circumstances, molten aluminum may come in contact with the insulation. Molten metal may penetrate to the insulation through lower wall refractories which crack during installation, dryout or other reasons. To evaluate those conditions, the modified B-Immersion test was used. Results are found in Table III and Figures 1--8. Although all the insulations showed good to excellent to molten aluminum resistance as indicated by the high weight retention, the mineral wool products, PV Supertemp and Mono-Block, did shrink and bowed excessively upon metal contact. In actual service conditions, this type of behavior may leave gaps in the lining allowing further metal penetration. For fibrous products, Rim 410-03 and Delta-T, metal resistance was good; both materials remained intact even though some penetration was seen in the Delta-T. The other materials (IV-19, IV-20, Superex 2000, Superex 1600, and Skamolex PM-10) performed excellently; the metal skull retained coul<3 be easily removed. Safety Statement Although these materials do not contain asbestos, some are composed of free crystalline silica (see Table I for analyses). It is the uncombined silicon dioxide (SiOj) in these insulations which may lead to lung disease. Of primary concern is silicosis, a noncancerous disease of the lungs. Silicates, although consisting of silicon and oxygen, combined with other elements in a complex molecules, with the exception of asbestos and some talcs, silicate dusts should not ordinarily cause disabling lung conditions such as produced by free silica. It is uncombined or free silica APC 003898 Memorandum 1979-11-08 Page 6 however that is most important in industrial dust exposure. To detect an exposure properly, the percentage of uncombined silica must be determined by petrographic analysis, preferably by X-ray diffraction or infrared techniques. It is generally stated that the size of the offending dust particles is of extreme importance in determining the concentration of particles that may be suspended in the air. The size of particles also determines the depth to which these particles penetrate into the lung along with the quantity that may become deposited and retained. Particulates less than 10 microns in size are potentially the most harmful. Generally, when airborne particles are larger than 10 microns, they are not of concern because they are unable to penetrate into the lung where they could be damaging. Instead they are removed and collected by the nasal passages or upper respiratory system. Also, it has been generally stated that the duration of dust inhalation is of extreme importance. Persons who for many years have continuously inhaled free silica dust have a great likelihood of contracting a silica-related disease. Those who only intermit tently inhale the dust have less risk of injury. In addition, those persons who smoke will increase the risk which otherwise exists. It is important to be aware that exposure to silica dust can occur during the installation of some of these products that contain free silica as well as during tear-out and repair of facilities where these products were previously installed. It is recommended that personnel working with these insulations wear respirator and eye protection, and that the area be properly ventilated. Periodic safety monitoring of the free silica should be scheduled also. Conclusions 1. Major insulation materials in the high temperature range are (listed in ascending order of temperature resistance): a. Mineral Fiber, 540 to 1040C (1000 to 1900F)-- PV Supertemp and Mono-Block. b. Calcium Silicate and Silica, 870 to 1100C (1600 to 2000F)--IV-19, IV-20, Superex 2000, Superex 1600, and Skamolex PM-10. c. Ceramic Fibers Based on the A1203--SiO- Systems, 1100 to 1260C (2000 to 2300F)--Delta-T and Rim 410-03. 2. High compression strengths were found for IV-19, IV-20, Superex 2000, Superex 1600, and Skamolex PM-10, whereas fibrous materials (PV Supertemp, Mono-Block, Delta-T, and APC003899 Memorandum 1979-11-08 Page 7 Rim 410-03) show the least resistance to deformation or high compressibility. 3. Thermal conductivity values did not vary significantly between the insulation types examined. 4. Although exhibiting nonwettability, mineral wool insulations (PV Supertemp and Mono-Block) do shrink excessively in contact with molten aluminum. Other products (calcium silicate, silica or ceramic fiber materials) all have good-to-excellent resistance. 5. Products IV-19, IV-20, Superex 2000, Superex 1600, and Skamolex PM-10 have been identified as containing free crystal line silica. Largest contents were found in Superex 2000, IV-20 and IV-19. Recommendations Again, each application must be considered individually when recommending insulation. One must consider the thermal conditions imposed by service along with each particular insulation's qualities of mechanical strength, chemical compatibility, weight, compactness, heat flow resistance, and so forth. In many cases it must be recognized that local availablility and delivery will at times necessitate the use of a product'in a specific class. For ingot melting and holding furnaces, one of the most important developments by Pittsburgh Mechanical Engineering in the past year was the development of a computer program to investigate temperature profiles. On the basis of a computer study and this present work, lower furnace walls are now being backed up with 50.8 cm (2 in.) of Rim 410-03 or Delta-T insulation in place of 50.8 cm of PV Supertemp and 50.8 cm of Superex 2000. This design has established a more realistic metal freeze plane with insulations that are both compressible and molten metal resistant. This construction should prevent frequency of furnace bleedouts and conserve energy. Other ingot applications such as troughing, filter units, etct, are being reviewed, and better materials and designs are being plant tried. With proper design and material selection, improved service life and more comfortable working conditions should be realized. Finally, in handling some of these products studied, particularly Superex 2000 and IV-20, special precautions must be taken to minimize dusting. Without adequate ventilation and respirators, a safety problem does exist. APC 003900 .. o N 4J 01 u *H H 1. rH CO x Mh *. rH /*>, 4J <0 3 tr /--X N* 4J Vi o ft) c <f 44 4H ft) CO 3 N to H o tr U iH O tH a. V U pH e pH to 0> o W3 CO a tr Suw <0 3 a SP ft) to X p Cl r-i Jn *rt H Uh to CM O O CO <0 CM o Vt ft) 4-1 Stop (0 rt cU <C 3 e *u x CL pH (0 fH to pH e PS O VI t_5 H <0 u p PS fH 3 to o 1X cj a. u fH V* O e Vi oCM f* CO o H pH to N pH N pH o ft) 1 fH e e 4J 6 *J 6 X p"\ Ua CO *. Vi to U to eo CN V Q fH IH C ftH W > (0 u3 pH V (0 to 3 pf cr o P ft) Pf o ft) C 4J 4H S^ Vi o (0 3 pH u to Sw H * o 4J 4J s^ tO X u (0 tH x 4-1 to H --< CM cr X > D3 H Cu pH a w pH to 3 CO p tfVi | X G fH C 0 H O ft) pH fH 4J fH iH H U HeO Uo o pH 4-) B pH c W u H o 3 eU BO oO X CM pH 0/m^ CO sp wO CM Oo pH H o to *3- 1 H CO CO ft) 60 o a pH 3 x> o S(4P xO 4-1 CL (0 CM Vf H O o Sh H e u to (0 SpP 1 C5 ft) CM o pH Oc H E (0 xCO (3 0 u p c V) > fH Vt oc o SP c 3 CM o pH fH E fX sO CL O pH sO to H SP to CM CM P**v o oX H to w1 m0 to CM PS Xo rs pH o sO H to sO to B s ft) a CO to to pH to to o H U 4-) 60 w Vi CQ E ft) c hJ o ft) H o > pa *3 > ft) to ft) to o 6 CO ft) ft) eo 60 > 2 p) pj pJ n o tH H <f m to 1 CM pH < sO t ** 1 r-* CM i ANALYSES OF ASBESTQS-FREE INSULATIONS -- MANUFACTURER'S DATA o 00 K 03 CM1 3tfl H> O HH C c < m to o 3u CM u. oo -aI- m I CM I pH CT\ r-f CM A CM ^cin <r COOs Om pUH"i vO Px. pH in mt o <r < pH pH *C in CM m II m O m CM Os oo co II co *h CO so O OS r- Os m 4 4J O 3 > *3 )O 3 Li 4 SL, 3 : "J 3C : to Vi CL ft) 3 X ft) U LJ H Vi CL ft) a ft) 3 pH tO 00 to > Hi cv u 0 pH ra ai L*. O ft) 3 ft* O ^X H 1 3 to Cu 3 pH 3L a tr. 4-1 o 3 *3 G Li m 0- o 1 no , 4 pH (X *T pH 3 c 4J C H o pH f 3 4.1 U n c: G ii L4 Os 3 fj pH L> J c Ip PH pH 3 <0 4.1 c H o pH fH 3 4J 3 to fH c (= Li u O CJ 3 CM 4_l c PH > 1 > PH ARC 003901 00 CM dd Cl 0otO) O HVl o cn cm o o O o VO co SO MT 00 SO CM stf Os rr-* -o CS 3 pH pH o H o >o c CM to X *1* 3 tn Li r. 3 a. *6 3 -> to CM pH 3 pH O H o >X C pH n >: t3 V, kH c3 X CL o3 3 to >? *-H O pH 1 c>i 3 pH Oo nL '3 cj C to to COOI TABLE I tame II PROPERTIES OF ASBESTOS-FREE INSULATIONS o - cl OOC O OO eoo o oo =I tl --c ----** --eCO ----Wv 9 ss ---> oN OOoo (A m O' - 12 N C ^O IS O-o ---- - nO ^O n-- oN o' oooooo -- CO r> * -- - in n o oo o o o -- n* -o me* IN* o * rn hft -- o <* a> *n OOOO -- a --o itao o>e oeo ca4a 0o O' IA \D -- Kl* >l M0 0* M0 K0 0 f Cdl oO d-- o-- o oo ooooo oo oooo o oooo o o--od-- d-- o >J A h <P O e -- oo o o 0 00 0-- dodo moddmvB D *. o --O oooeo r* -- * * sr> w o <- J- >* O ARC 003902 3 js3s(3j oo * rJHt3soJ rXs03H 3 *A4ohuccOJJ* Xu(30 33ac rTCH3Q rJJ0HJJ) X r0H) r*HrJ * CCa6OO *rHa3H) r(H3 CoEcOO. XJ3J xtcaaoo> MO-l 73 JJ r3>O3U>sCC0HHOO)-Txo30a5C3o3Qi rXJC3HJO XUt33o rH0) <CasO0. Jo3HJ z00 "JJu0(a3Oa00JJ)) rH rH JOJ CuCaouOO> . XJ<0>oj MaoH rC3oHoO T3>oe0U3*) rtCc3HHOO rrHH rraHH0. *o3 MiXHCM3mO 0gO) 3 V) m rJHCHJO) u>0o3) XX M>OE3 rS30CHHO)s rH XJ33J , J>E303m jOj 33>3s U3>>> rH J33J X JO3HJ JM3a333J rH3 XH >H X0 JO3HJ JM3J 3338. r3H iiXHH3> z0 . *J30HJ JM33a38J r3H X*3H > XO J0sHJ0 PS CUoou >M3 PMOOm >?M0)s uoo JJ JOJ rr30HH) *OOOo W3OX JJ rrH33H w3XO rrj3HH8j WX3U JJ rrHH83 wX3U rrJ3HH8J w3CXJ JJ rrW33OX3HH MOLTEN ALUMINUM CORROSION RESISTANT INSULATIONS fr-S 3XJ00HJ)0 T*PJ0<03HS3J0)) UJuUt3o3o-Jl xCc3O 7cc3O r-H tU3Ho XjCjO m rH o < rH O X CM p0*0*. <r> a* COMs raHs oas <ONr 0p>0. XX 0r0* rJH3HJ rjH3Hj U3H 3aH a3E* CjMaO3Oj>. > rX*cWmhHa0oC0l1O1)o, raoH XXOco1 *3C33s rHJtH1oJ 3c0) Q3 U3 CO -rOor3Ho1* TCjuuO3H3j *OEHS >su3 rH *U33Orl Or>MH1N MJ3M333J >3MS rH J330HJ COM 33U3 H>1H mJ3J OCOOM rrHH3>3H c3U3Xa3o. xx3O331 HOXrOHC rr*3HH>3H 3 Cux33Q3O. xXtO3-1o} HroHC XP1i rHX30E3 rOE3H co co jM3333j rr3o3HHo cm O jj T333 XO33> J3OJ HXOj30Oejh APC 003903 JE H ines/1979-11-08 TABLE I I I 7 EAGLE PICHER J. P. AUSTIN APC 003904 MONO - BLOCK KEENE CORPORATION . ... r-.^Ta. J DELTA T KEENE CORPORATION APC 003906 APC 003907 [International VERMICULITE CO. fr APC 003908 FIGURE 6 APC 003909 FIGURE 7 APC 003910 FIGURE 8 APC 003911 TYPE: Block TEMPERATURE: Jo 1900 PF PBSCTlptlOTi: Eagle-Picher "PV" Supertemp Block is composed of high temperature mineral fibers bonded with specially prepared binders to form a block insulation having optimum properties during both installation and service. Fibers axe oriented to insure maximum strength and thermal efficiency. The blocks are "wet-sawed" by a patented process to provide precise dimensional tolerances and freedom from dust. "PV" SUPERTEMPBLOCK Uses: Recommended for direct application or refractory back-up insulation in petroleum and process units, power generation equipment, ovens, furnaces, kilns and other related equipment requiring an insulation that is economical, efficient and dimensionally stable. Advantages: Durability: Strong yet resilient, processed to maintain structural integrity during field application. Absorption: Allows placement of castable refractories in direct contact with the block without degradation. Installation:Can be impaled on pins without predrilling. Easily field fabricated with knife or saw. Standard sizes up to 24" x 36" permit rapid installation. Physical Properties: Service Temperature...................... to 1900F. Density....................i... 16-18 lbs./cu. ft. Moisture Absorption..................................... Nil Fire Resistance .......................... Incombustible Corrosion............ Does not cause or accelerate \ Physical Properties' (confd): Linear Shrinkage at 1600F..................... ................ 2.0% 1800F............................................. 2.2% Modulus of Rupture............... 40.0 Ibs./sq. in. Compressive Strength.............2,600 Ibs./sq. ft. at 10% Deformation Thermal Conductivity: Mean Temperature F. "K" (Btu-in./hr./ sq. ft./F.) 200 400 600 800 1000 0.28 0.38 0.49 . 0.59 0.69 iHACLS APC 003912 1.1.2 ,\- ... j-* Ei "PV" SUPERTEMP BLOCK Standard Sizes: -. Thickness: Width: Length: 1" to 454" in 54" increments 6", 12" 18" and 24" 18" and 36" Special sizes and shapes are available and are quoted on request Applicable Specifications: Commercial Standard CS-117 ASTM C612-67T. Class D Federal 11H-I-55S, Form A. Class 5 Packaging: 6x IS 12 x 18 6x 36 12x 36 18x 36 24 x 36 Board Feet per Carton 1" 154" 2'* 214" 3" 354" 4" 454" 48 45 48 45 45 42 48 40.5 48 45 48 45 45 42 48 40.5 48 4S 48 45 45 42 48 40.5 48 45 48 45 45 42 48 40.5 54 54 54 45 54 47.25 54 40.5 48 54 48 45 54 42 48 54 lEACJLS l-- -rr?5' 5//>c iS4j t' Manufactured by s. i* A d! EAGLE-P1CHER INDUSTRIES, Fibers Department APC 009913 INC. sr MONO-BLOCK Mineral Wool Insulation For Service to 1900 F-Asbestos Free DESCRIPTION: MONO-BLOCK is composed of spun mineral fibers and inorganic binders especially formulated for resistance to high temperatures. A patented process interlocks the long mineral fibers to form a lightweight and rigid, yet resilient block which is shaped and fitted. TYPICAL USES: Heat Treating Ovens Boilers Incinerators Chemical Treating Tanks Refinery Equipment Ducts and Breechings Feed Water Heaters Wind Tunnels' Jet Silencers' Fan Housings' 'Acoustical Applications PHYSICAL PROPERTIES: Density -- 12 Ibs./cu. ft. miniumum Compressive Strength -- 10 lbs./ sq. in. @ 10% deformation Flexural Strength -- 40 Ibs./sq. in. Linear Shrinkage after heating 24 hrs. at1900*F Soaking Heat -- Less than 5% Single Face -- Less than 5% THERMAL CONDUCTIVITY: Mean Temp. "F 200 400 600 800 1000 1200 K .36 .42 .51 .62 .75 .90 STANDARD SIZES AVAILABLE: Length -- " 3. 36 inches Width -- 5.12. 24 inches Thickness -- 1 -4 inches in Vi inch increments SPECIFICATION COMPLIANCE: Military: MIL-I-24244A* Federal: HH-I-558B Form A Class 5 ASTM: C612-70 Class 5 Indicate o* z'Ce' v/nen specification compliance :s resuired. THICKNESS VS HOT-FACE -- COLO-FACE TEMP. CHART 1373 Easy to Apply -- Easily cut with a knife. Conforms to slight curvatures or projections such as rivet heads, pro viding a snug fit without cracking or breaking. Can be impaled over welded studs without predrilling holes. High Strength -- Strong because of long mineral fibers and unique manu-' facluring process which uses inorganic binders. This extra strength guards against breakage loss. Low Chloride/Moisture Resistant -- Acceptable for use on austenitic stain less steel. Etlective Acoustical Properties -- High sound absorption elficiency makes this product applicable where acoustical treatment is required at elevated temperatures. KEENE _ : "i o i< aiiom INSULATION iilc.n l*.: KAIAVAZOO. MICHIGAN oooj 3-53fEitfc ut*j:rno:3 APC 003914 Thermal Conductivity Mean Temp. F 200 400 600 800 1000 1200 1400 1600 K .43 .52 .60 .74 .84 .98 1.15 1.30 () NU WO () -Ok) f*i) oOo Oo oOo 2J. *n n ti 2. iCoOk 3 X 3O3 15. 3O75' O @ () 3 ui OO. QO. 9 OQ. to <<* ooo 335- U oa 3o' 53* O -3 (O 5 *D V> T3 (A TtoJ 2 o ac. c (A O 33 C a c -On o 4A a 3CD S3 oS 2. -cr cr <5o* 3=: c5* *. o c Jog* M3 S-o tO A COOO OOO oo ooto o 3o o A -a O o^o cn a01r0o )f0o '-si fo b 03 cn i '* ' rjtf'i* 03 fO |0>; v' NOO3 :AOOo 03 .J ; Oo **:>.. *3 3! o |181 Q. TM D> ffl 5 5* 3 p. w;5 .g ^ 03 t\> '. : *S4 03 *s| V'.-,- (Q 3: e* . cnO 0O3 '.cno. ^ u' V. *./'t3tt <O0P. 3f ;*. ':, o'- m o O CA c. %i <rnsr 3 ? a3 se. a 5 2. 3 NO OQ (A (A =r 3(0 al(,. (A <2. --(A% (ND < SW 3. 5T 2 J3 ?3 2O 33 75* ,, 3 2 .> ? *8o . . iOn o <S023too) H3|iTxJ5S'OoES3LWo3 >c33 o 3 2o g >3 o X 5. (CDL <Q~D. o! *S<L y> o (A V) o (2O.. .o3 >S 3Ot/3 2 o* X(D as H >p c 3& : o3 MMl x (A 2 H 7\. O (/) > IS) o oO 6 o* O Po o' 3-a3OT* s 2o SL !T.. If 25 fO A 03 O 3 <D Q. 2. -2 s.* eg Oe. 5o.. o 3 =r.. : 3o. A A IO fO 03 A cn cn 03 ro <7> A <A Qe. in C 0 R P OR A T I 0 N Building Products Division i*>03 ru'toni S:oc. Kalamazoo. Mch**jnn <0003 ^PC 003915 / Hi-ALUMINA ceramic fiber products are made by bonding alumina-silica fibers with high purity alumina. No starch, silica, clays or asbestos are used. As a result, low den sity insulating products are obtained with high alumina contents.These Hi-ALUMINA products outperform conventional silicabonded products. i Three products are offerred for three tem perature ranges with three markedly differ i ent costs. In this way, users are able to obtain the most economical insulation for any particular temperature range. Also available for the 3000nF range are our ALL-ALUMINA products described in a separate bulletin (AA-320). PRODUCTS AVAILABLE I TypeAH-50 77%A1203 For 1500C (2732F) f TypeAH-30 61%A1203 For 14003C(2552"'F) t Type 410 54%A1 203 For 1300C (2372F) All of the above products are available in the form of boards, tubes, cylinders or special shapes. The products can be varied in size, thickness, degree of hardness and surface finish. j APPLICATIONS | The principal use for these products is as a rigid form of a low density, high temperature insulation. The alumina-insula tion requires 50% less insulation than conventional brick insulation. Fast heat-up, fast cool down and low heat storage j make this insulation ideal because of today's energy shortage. j Among the insulation uses are furnace linings, back-up insulation, heat shielding, induction coil liners, combustion ! chambers, stack insulation and high temperature pipe insulation. The non-wetting characteristics of alumina binderand alumina-silica fibers to molten metal makes these products desir! able for many molten metal applications. Among these are riser sleeves, hot top linings, trough linings and tap out j cones. | The low sodium content and high surface area of the alumina binder makes these products ideal catalyt supports for the ! flameless heater. I. I The low sodium content makes these products ideal for electrical heating element holders and radiant heater pads. I Other uses include burner blocks, expansion joints, kiln furniture, gaskets, peep hole plugs and seals. ^-------- ------- - - ............................................. APC 003916 PROPERTIES Chemical Composition A1203 (%) Si02 (%) Density (Ibs./cu. ft.) Modulus of rupture (psi) Loss on Ignition (%) (Absorbed Water) Linear shrinkage (%)* 1300:C (2372"F) 1400aC (2552F) 1500C (2732F) Thermal Conductivity (BTU-in./sq. ft. hr. F) 1300C (2372F) 1400C (2552F) 1500C (2732F) Melting Point Fibers Binder Recommended upper use temperature Thermal shock resistance Two-hour soak AH-50 77 23 11-12 60 2.3 1.2 2.0 2.5 AH-30 61 39 14-16 75 2.3 2.6 3.1 -- J 410 54 46 16-18 80 2.3 3.6 -- - 1.5 1.7 1.8 Above 3200F 3700F isook: 2732F Excellent 1.4 1.6 -- Above 3200F 3700F T400C 2552F Excellent 1.4 -- -- 3200F 3700F 1300C 2372F Excellent The above information is intended for use by persons having technical skill, at their own discretion and risk. It should not be taken as a warranty nor as a license to operate under, or recommendation to infringe any patent. Some of the above values are averages obtained on developmental material and are subject to change. They should not be used for specifi cation purposes. APC 003917 IV 19 Block Insulation Product Data Sheet IV-19 Block Insulation is an asbestosfree insulation, manufactured from vermiculite granules and high temperature bonding materials. It is a versatile product available in a wide range of sizes. Because of its low conductivity, IV-19 is an economical, energy saving insulation. It exhibits minimal shrinkage at top temperature limits, and will not decompose even when exposed directly to flame at or beyond maximum service temperature. IV-19 is zr. excellent back-up insulation as well as a highly efficient hot-face insulation for temperatures at or below 19C0 - F (1037 C). It's unique composition and hard surface helps insure strong adhesion of cement finishes, and provides superior handling qualities. IV-19 can be manufactured with either straight or beveled edges to meet customer specifications. Standard sizes and weights are listed on the price sheet. Prices for custom size blocks will be quoted upon request. Asbestos-free Apc 003918 Product Data Sheet IV 19 Block Insulation Physical Properties: Temperature 1900 F 1037 C Conductivity 0.56 "k" at 200 F (.0808 W/mK at 93 C) 0.64 "k" at 400s F (.0923 W/mK at 204 C) 0.72 "k" at 600F (.1038 W/m*K at 315.6 C) 0.80 "k" at 800s F (.1154 W/m-K at 425.7 C) . 0.88 "k" at 1000 F (.1269 W/mK at 537.8 C) Linear Shrinkage At 1900s F (1037s C): 2.25% Chemical Analysis Vermiculite, the basic component of IV-19, is a magnesium, aluminum, iron silicae. It contains no free oxides. Al*0, 9.19 CaO 11.51 Si02 54.38 KzO 3.72 As Silicate CraO,, TiOj Fe, 0, 5.35 Na,0. Mn,04 0.86 Mg 0 . 13.16 CombinedH20 1.84 Shipping: Carton I )' IV-19 is available in ' ^3f J standard block thicknesses of 1 " to 6" in Vi" increments with the other dimensions measuring 6" x 18", 6" x 36", 12" x18" or 12" x 36". Special sizes available on request. Density Cold: 20.5 Ib/fi* (323.4 kg/mJ) At 1900 F/1037 C: 19 lb/ft* (304.4 kg/m>) Crushing Strength Cold: 125 PSI (.0878 kg/mm*) At 1900 F (1037 C): 51 PSI (.0359 kg/mrn*) Area of Application: End/Sidewalls B PI IV-19 has a wide variety LJ of uses in high 1 1 temperature industrial furnaces including end and side walls of various heating furnaces ... soaking pits, reheat furnaces, carbonizing furnaces and other annealing furnaces. IV-19 is applied as backup insulation as well as hot face material at temperatures of 1900 F (1037 C) and below, for example IV-19 could be used in duct or flue linings and cyclones. V Modulus of Rupture Cold: 73.5 PSI (.0517 kg/mm*) At 1900s F (1037" C): 51.5 PSI (.0332 kg/mmi) Method of Application: Block Construction Install, using standard procedures for block construction. AFC 003919 .. f >__ o*.., ec/ .a eoc^n/017.07.oiao 1A477-0S 7 -7 3 IV-20 Block Insulation Product Data Sheet 3 IV-20 Block Insulation, mads from diatomaceous silica with a hydraulic binder, is a superior high temperature insulation for service to 2000 F (1093 C). According to ASTM testing procedures, IV-20 exhibits extremely high resistance to breakage at 2000 F (1093 C). Long maintenance-free service and maximum operating efficiency is assured by IV-20's unique combination o' low conductivity and high stability. IV-20 is also very low in sulfur and iron, making it highly resistant to attack from atmospheric conditions and greatly reducing the possibility of product contamination. Like other International Ver. .iculite products, IV-20 is produced in a wide range of standard block sizes, available with either beveled or straight edges. This product can also be manufactured in special shapes to fit customer specifications, saving money on both installation and energy costs. Area w rv, Shipping \ -a J.t-2 KI..-. y APC 003920 7 Product Data Sheet 1V-20 Block Insulation Physical Properties: Temperature 2000 F 1093 C Conductivity .65 "k" at 400F 1- .n (.0938 W/m*K at 204.4C) in .70 "it" at 600"F (.1009 W/m-K at 315.63C) .77 ,,k'' at 800 F (.1111 W/m*K at 426.7C) .89 "k" at 1000F (.1284 W/mK at 537.8C) Density- Cold: 24.5 !b/ft' (392.2 kg/mJ) At 2000 F (1093 C): 23.5 Ib/ft* (376.4 kg/m>) Crushing Strength Cold: 176 PSI (.1237 kg/rnrns) At 2000 F (1093 C): 150 PSI (.1055 kg/mm1) Modulus of Rupture Cold: 55 PSI (.03857 kg /mm*) At 2000 F (1093 C): 90 PSI (.0633 kg/mm>) Linear Shrinkage ; *Jr 4M \-:ssj3 at 2000 F Mail (1093 C): Z8% Si02 AijO* CaO Chemical Analysis IV-20 is made from diatomaceous silica with hydraulic binder. 79.0% MgO 3.8% 3.9% FejO, ' 1.3%' 6.8% Ignition loss 5.1% Shipping: Carton IV-20 is available in standard block thicknesses of 1" to 6" in Vi" increments with the other dimensions measuring 6" x 18", 6" x 36", 12" x 18" and 12" x 36". Special sizes available on request Area of Application: End or Side Walls 0n IV-20 is primarily a sida fcj wall and end wall I--------------- 1 insulating material. Whether it's used as a hot face or a backup depends upon customer requirements and the IV-20's 2000 F (1093 C) service range. The wide range of uses includes such diverse applications as, soaking pits, reheat and pusher furnaces, copper reverbatory furnaces, petroleum reactor vessels and oil fired water tube boilers. Method of Application: Block Construction Install using standard procedures for block construction. APC 003921 8 International Vermiculite Company/Post Office Box 66/Girard, Illinois 62640/Telephone 217-627-2193 18477-03 Johns-Manviiie Refractory M\ Products 3i:pre:cT'/ Block insulation Type: Block Temp. Limit: 2000F Ccscription Superex block insulation products are manufactured from carefully selected combinations of silica, lime, clays, and fibers for reinforcement purposes. These products are characterized by high strength, both cold and at elevated temperatures, and high refractoriness. They can be used right up to their temperature use limits -- and in some conditions even beyond -- should upset conditions occur. They uniquely combine low thermal conductivity and high stability at elevated temperatures to provide efficiency of construction and thermal performance, and long maintenance-free service. Superex Block products contain no asbestos fibers and are not soluble in water. Repeated wettings have no effect on this insulation. Superex products are not recommended as a furnace lining material exposed to combustion conditions unless a great deal of past experience shows the product to be satisfactory in a particular application. Typical Applications Superex block is designed as a backup insulation for all refractory constructions; i.e., insulating firebrick, dense fireclay brick, castables, plastic refractories and also ceramic fiber felts and blankets. All Superex block performs well at high temperatures and efficient designing of a refractory system with Superex as the backup insulation will reduce the amount of hot face refractories required. The most thermally efficient and cost effective system is obtained when the lowest thermal conductivity materials are placed in the hottest possible location. The excellent heat resistance of Superex block allows this. The most thermally efficient systems utilize Superex 1600 as backup to Superex 2000. Superex block is good insurance, too. Any refractory construction can be expected to crack in service and allow full lurnace temperatures into the back-up insulation. Its high refractoriness will help to prevent catastrophic failure of important equipment and allow operation until a more convenient rebuild or repair time is reached. Uses Ovens Soaking Pits High Temperature Mains and Flues Industrial Boilers Marine Boilers Regenerators Kilns Roasters Reverberatory Furnaces Reheat Furnaces Annealing Furnaces Heat Treating Furnaces Combustion Air Piping Bustle Pipes Blast Furnace Stoves Glass Lehrs Car Tops Forge Furnaces Laboratory Furnaces Cooking Equipment Advantages Exceptional Heat Resistance. Superex Block can be used to its full temperature use limit. Its high refractoriness also offers some insurance against immediate failure should these temperatures be exceeded. Excellent Strength. Easy to install; resists damage both in installation and in operation. Lightweight. Reduces structural steel requirements; ideal for insulating movable equipment. Special Shapes. Good strength properties make Superex block ideal for cutting and grinding special shapes. J-M can supply these to your specific requirements. Sect. 140 Part 10 Date: 4-78 Cancels: 10-77 AF*C 003922 So.2:;;ic3i:on Daiu Avniirbli' Form; Superex 2000 -- A high-density, low-calcium oxide content block, designed tor low shrinkage and top performance at temperatures up to 2000F. Superex 1600 -- Has a higher calcium oxide content and lower density than Superex 2000. This formulation gives better strength and insulating properties for use in situations where temperature will not exceed 1600F. Superex 2000 SG --Composite insulation block made up of Superex and a layer of spun-attenuated glass fiber, bonded together at the factory. The fiber glass layer, consisting of 1000 Series Spin Glas i, increase the insulation effectiveness of the Superex block and also serves as a mechanical "cushion" between the block and the steel shell of a furnace Normal Service Temperature, F, (oxidizing atmosphere) Superex 2000 2000 Superex 1600 16000 Marking None Green strip on end Density, Ibs/cu ft 24 14 Modulus of Rupture, Ibs/sq in 45 65 Compressive Strength Ibs/sq in to produce 5% deformation (2' thickness) 130 165 Linear shrinkage, % after 24 hours soaking heat 2.7 @ 2000F 1.4 @ 1600"F Chemical composition, % Silica, Si02 Alumina, AI2O3 Calcium Oxide CaO Ferric Oxide, Fe203 Titania, Ti02 Magnesia, MgO Alkalies, as Na20 & K2O Sulphur Trioxide. S03 Others Loss on Ignition 74.8 4.3 6.0 2.0 0.3 0.8 2.7 0.0 ' -- 9.1 49.6 1.2 37.6 0.3 Trace 0.2 0.0 Trace 0.2 10.9 Sispsrsx Block Insulation Compressive Data on Superex 2000 SG (2'A" Superex 2000 plus 3.'a 1000 Series Spin-Glas) Compressive Strength of 3" Superex 2000 SG______ CompressedAs Load to Compress, psi Thickness Received Hot Face of Superex (24-hr test) (in.) 1600: F 1800'F 1900' 3.00 2.90 2.75 2.50 2.25 0 1.4 3.5 22.6 66.0 0 0.6 2.4 21.1 29.0 0 0.4 1.5 12.5 70.0 0 0.4 1.6 13.5 73.0 Recovery of 3" Superex 2000 SG After Compression Compressed Thickness of Superex 2000 SG after release Thickness (Percent of original thickness) Hot Face of Superex As (24 hour test) Inch % Received 1600*6 1800F 1900*F 2.90 2.75 2.50 97 99 92 99 83 95 99 99 99 97 97 97 93 93 93 Standard Sizes All dimensions in inches Thicknesses in Vft inch Superex 2000 Superex 1600 increments 1 to 5 1 to4 Superex 2000 SG 1 Vi to 6 Widths and Lengths 12x36 6x36 18x36 12x36 12x18 6x36 18x18 Beveled blocks are tapered to specific requirements. Outside diameter of circle is to be specified on order. 2131 Johns-Manvills Ken-Caryl Ranch Denver, Colorado 80217 For information on other J-M Thermal Insulations and Systems, write the Johns-Manville Insulation Center, Drawer 17L. Denver. Colorado 80217 or call (303) 979-1000. The physical properties of Johns-Manville Superex block insulation represent typical, average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. They are supplied as a technical service and are subject to change without notice. Check the Johns-Manville district office to assure current information. *NO 3009 4 78 APC 003923 Lriho in USA Asbestosfree Calcium Silicate Slab Insulation c Bulk density (dry).................................... 250 kg/m3 Porosity.................................................... 89% Cold crushing strength.......................... 2.0 MN/m! (20 kp/cmJ) Compressivestrengthat5%deformation1.7 MN/m2 (17 kp/cm2) Modulusof rupture................................ 0.6 MN/m2 (6 kp/cm2) Recommended service temperature (back-up)................................................ . 1000C Linear reheat shrinkage DIN 51066 BL.2(12h95'0C)............ Specific heat.......................................... . 0.75 kJ/kg K (0.18 kcal./kgC) Thermal conductivity at mean temp. W/m K 10C.......... 0.054 200C.......... 0.065 400C.......... 0.087 600 C.......... 0.109 800C.......... 0.132 Kcal./m.h.C 0.046 0.056 0.075 0.094 0.114 Pyrometric cone equivalent................ 1400C Thermal expansion coefficient 20-730C............................................ . 0.74x10 s/K The above properties represent average test values. They are given in good faith but no guarantee is im plied. SiO:............................ CaO............................ FcjOj............................ AlrOj.......................... Ignition loss................ (mainlv H.-O and CO?) 41 % 42 % 0.5 % 1.2 % 13 % HI i * iZ rff ~r i Iw j&irii'ai Skamolex PM-10 is available as flat boards of stan dard size 1000 x 610 mm with thicknesses of 25- 30-40-50-60-75-100 mm. Other sizes or shapes, e.g. with bevelled edges, can be supplied to suit spe cific design requirements. For agglutination of slabs, or for adhering Skamolex ' PM-10 to refractory and metallic surfaces, we recom mend the use of SKAMOL FL-06 Mortar. This adhe sive is supplied as a dry mix in 25 kg bags, ready for use after addition of water. Adhesive thickness should not exceed 5 mm. Skamolex PM-10 in standard size 1000 x 610 mm is offered in shrink film wrapped packs holding be tween 1.83 and 6.10 m2 of board depending on thick ness. Packs are palletised for shipment on nonreturnable pallets, secured with nylon strapping. One pallet unit comprises 2.25 m3 shipping volume. PACKING SPECIFICATION Thickness mm 25 30 40 50 60 75 100 Content per pack slabs m1 10 6.10 10 6.10 5 3.05 5 3.05 5 3.05 3 1.83 3 1.83 Content per pallet packs ma 14 85.4 12 73.2 18 54.9 14 42.7 12 36.6 16 29.3 12 22.0 Packing in wooden crates or cases quoted upon re quest. SKARREHAGE MOLERWERK A/s DK-7900 NYKOSING MORS . DENMARK . TEL. INTERN. 45-7-72 15 33 . TELEX 66680 >1 ITrr' r^r"v-r^rSwV'xV-V*, **?w w .- - - - *--- k,' (XmAA Asbestosfree Calcium Silicate Slab Insulation. An extremely lightweight calcium silicate slab, fibre reinforced but completely free of any asbestos and crystalline silica. It is designed as a final back-up in sulation between refractory linings and furnace casing for interface temperatu res up to 1000C. A low density product - 250 kg/mJ - of good strength and low thermal conductivity throughout its temperature range of service. Excellent resistance to carbon monoxide and a number of other gases, and good perfor mance in contact with molten aluminium. The large sized slabs - standard size 1000 x 610 mm - of accurate shape and clean edges speed construction and improve insulation efficiency. The slabs are easy and clean to handle because of a negligible dust emission. Due to their porous structure the slabs are easily shaped on site by ordinary woodworking tools - fixing can be made with nails or screws. A specially de veloped adhesive is also available. * FR0M HAIG G. SAKOIAN PITTSBURGH OFFICE - 7 T0 MEMORANDUM URGENT1-URGENT1 1979 July 03 RE; "SUPEREX 2000" POT LINING INSULATION Johns-Manville Corporation's "Superex 2000" pot lining insulation has been found to contain relatively high concentrations of free silica and cristobalite. The allowable TLV for exposure by inhalation to this material is greatly reduced because the calculation of the TLV is based on the amount of free silica or cristobalite, i.e,, TLV = 10 mg/M^ ______ for respirable dust -- or 30 mg/M _ % Free Silica +2 for total dust. % Free Silica +3 Sampling performed at several locations which use "Superex 2000" for pot lining indicate possible silica exposures above recommended limits even when employees are working with the material for only brief periods. Mr. D. D. McGregor, Pittsburgh Office, has alerted all smelting Produc tion Managers of this problem and recommended they minimize cutting and handling of this material, if it has not been done so already, it is recommended that sampling be -performed for respirable dust, with analyses for percent of quartz and cristobalite, to assess employee exposures. In the interim, based on sampling results from several locations, it is recommended that respiratory protection be afforded employees working with this material. Any respirator approved for pneumoconiosis and fibrosis-producing dusts would be acceptable. These include the 3M-8710; AO R2090 MSA Comfo II with Type F filters; and others. If air sampling indicates airborne concentrations in excess of the protection factors afforded by these respirators (5 times the TLV for quarter-mask; 10 times the TLV for the half-mask), then more adequate respiratory protection... or better control... must be implemented. Conversely, if sampling indicates no problem at your location, the requirement for respirators may be lifted. If control measures are implemented, follow-up sampling should be performed to test their effectiveness. It is understood that some locations are already working towards a solution to this problem. Any information gained through such efforts which may be useful to other locations would be appreciated. HAIG G. SAKOIAN HGS/eds .Distribution: See Page 2 ALCOA APC 003926 ftp-4949 MEMORANDUM 1979 July 03 Page 2 Distribution: E. M. Morgan Badin Works L. A. Hartley Badin Works G. D. Hicks Massena Operations B. M. Triko Massena Operations A. G. Clayton Rockdale Works G. H. Lantz Rockdale Works J. C. Vergho Tennessee Operations R. E. Seymour Tennessee Operations R. E. Podhora Pt. Comfort Operations F. A. Sharkey Pt. Comfort Operations L. L. Haisch Vancouver Operations P. C. Ames Vancouver Operations K. P. Karsten Warrick Operations J. R. Haaland Warrick Operations M. R. Borjas Veracruz, Mexico J. L. Fox - Veracruz, Mexico E. E. Rumberger/T. B. Bonney - Pittsburgh 7 D. D. McGregor - Pittsburgh 23 G. T. Holmes/J. A. Lang/R. J. Hosfeld - Pittsburgh 23 R. S. Danchik/D. R. Balya - ATC M. J. Caprio - Pittsburgh 19 RECENFO JUt o 5 W9 PURCHASING APC 003927