Document 1Qed7EYeber46reOpyZQb6DGK

BCCi P. 0. BEUIGNUS D. A. OLSON August 84, 1970 Mr. J. R. Rafter Crlnnoll Company 260 Meat Exchange Street Providence, Rhode Island 02901 Bear Kr. Rafteri Monsanto's Aroolor 1254 and Aroclor 1260 which you use In sealed bulbs as a part of a high temperature sensing device for fire sprinkler systems do contain polychlorinated biphenyls (PCD). There is continuing evidence that PCB's are being identified es environmental oontanlnants. To avoid further contamination of the environment, Monsanto Management recently decided to selectively restrict tho calcs of Aroclors to those applications in which the escape of PCD'a to the environment can be continued. Extreme care must be taken to prevent Aroclors from entering a water system. Spillage and leakego must be Immediately corrected and all material used in clean-up must be carefully disposed. Fbr the small quantities Involved In your operation, 1 would suggest that burial in a properly managed authorised landfill would be appropriate. The matoriel which should be buried would include such waste as rags, failed bulbs, Bolvcnts used in olean-up, oil absorbents or sweeping compounds, snd containers. Burning, if attempted, must take place at temperatures exceeding 2000?, otherwise vaporisation or partial destruction take place. With complete incineration, provision must be made to collect and neutralise the HC1 gas which is formed. Por your application, I do not recommend burping. MONS 0U95i0 2- Vaporlzation must also be controlled. Therefore, In heating the Aroclor for easier handling, do not heat to a temperature higher than Is absolutely necessary. In my opinion, the amount of Aroclor that Is released when a bulb bursts as a result of a fire Is very minute and the benefits of the application far out weigh the extremely minor harm which may occur to the environment. I hope this information Is helpful to you. If 1 can be of further service, please let me know. Sincerely, W. B. Papogeorge Manager Environmental Control ms MQNS 0S9531