Document 1QdyJx051qd2Jq1yZjLnEnJ7X
fUULs T " & ^
6'/'/
_/-
Am ericax -<$t andard
G-60
gas fired boilers
1961 ]
gas fired boilers
1-- integral drafthood--prevents excessive downdrafts from affecting proper combustion. Located at rear of jacket on all models to provide low over-all height of 66Va".
2-- jacket-sturdy steel with smart gray finish, modern radius corners. Inner surfaces protected with heavy glass fiber insulation-prevents wasteful heat loss, keeps jacket cool.
3-- steam trim--left hand end steam trim is standard equipment. Right hand end steam trim available on order.
4 --automatic gas valves--A.G.A. approved, electrically operated, automatic diaphragm type valve. Can be man ually operated in case of current interruptions.
5-flue canopy--forms gas-tight connections between boiler flue passages and drafthood. Canopy completely enclosed by boiler jacket.
6-- cast iron sections--multiple pin-like projections for maximum heat extraction. Tested for 50 psi water working pressure; 80 psi water working pressure available on special order.
7-- resetting low water cut-off (steam boilers)--located within jacket enclosure. Electrically shuts off main gas supply to burners if boiler water reaches low point. Optional external types available.
8-- burners--precision made and factory tested to assure quiet, efficient operation with all gases. Cast iron, drilled port burners supplied for natural and mixed gases. Cleanable ribbon burners standard for all other gases and dual gas equipment.
9-- factory assembled manifold and controls--only requires attachment to boiler. Special manifolds for dual gas equip ment and FIA and FM installations available.
16480
G-oO
gas fired boilers
G-606 G-607 6-608 G-609 6-6010 6-6011
6-6013 6-6015 6-6017 6-6019 G-6021
G-6022 6-6025 6-6028 6-6031
6-6033 G-6037 6-6041
1% 1% 1% 1% 1% 2
2 2% 2Vi
2% 2%
2% 3 3 3
3 3 (2>-2%
2 2 2 2 2 2%
2% 2% 3 3 3
3 3 (2)-2% (2)-3
(2)-3 (2)-3 (2)-3
--
--
--
-- --
31% 35% 39% 43% 47%
35% 39% 43% 47%
39% 43% 47%
--
--
-- -- --
-- -- --
-- --
35*. 39% 43% 48%
39% 43% 48%
-- -- -- --
--
6% to
8% 8% 8%
8% 8% 8% 8%
8% 8% 8%
27% 31% 35% 39% 43% 47%
62% 71 79% 87% 95%
106% 119 131% 143%
158% 175% 191%
25% 29% 33% 37% 42% 46%
60% 69% 77% 86 94%
104% 117% 129% 142%
157% 1737/s
190%
26% 31 35K> 39% 43X. 47%
62% 70% 79% 87% 957*
106X. 1187* 131% 144
158% 175% 192%
_ _ _
__
--
3IX. 35% 39X. 43% 47%
35% 39X. 43% 47%
39X. 43% 47%
____
--
_ _ _
--
35*. 39% 43%. 48% 39% 43% 48%
5 6 7 8 9 10
12 14 16 18 20
21 24 27 30
32 36 40
gpRi&K,
11 11 11 12 12 12
22 22 24 24 24
33 36 36 36
48 48 48
sm
.bryoutofflowandrrtum ; v- iback view).
`
ffTpipetap fc' electric limit
v /layout of flow ahd return tappings
(both ends)
left hand end section
%-6-66GGG666GGG666-----6-6---66666666666666000000000000000o3292121311243118i551831779230l,`' .2222222222222222
d003033212221111
*
F322221311111T6789712482064868 -
:
00000122211233311
5 4222222222222222$"
2 2 2 2 2
2 2 2 2 2
2 2 2 2
2 2 2
(front view)
(^j^AMEracAN-<$rtandard.
16482
gas fired boilers
gas control and connection sizes; pertinent data
G-606 G-607 G-608 G-609 G-6010 G-6011
762
877 991 1106 1221 1335
504 2741 2751 581 3141 3151 658 3527 3537 753 3923 3934
813 4335 4346 890 4728 4739
2 2 2 2 2 2
2 IV* 2 IV* 2 IV* 2 IV2 22
2Vi 2
G-6013 G-6015 G-6017
G-6019 G-6021
1877 2106 2335 2564
2793
1252 1406 1561 1715 1870
6049 6835 7620 8503 9292
6069 6855
7640 8523 9312
2 2 2 Vi
2Vi 2y2
2Vi 2Vz 3
3 3
2 2Vi
2 Vi 2Vi 2V2
G-6022 G-6025
G-6028 G-6031
3220 3564
3908 4252
2154 2386 2618 2850
10139 11334
12616 13809
10154 11361
12648 13841
2Vz 3
33 3 (2)-2y2 3 (2)-3
2y2 3 3 3
G-6033 G-6037
G-6041
4793 5252 5710
3211 3521 3820
15036 16690
18316
15068 16720
18346
3 3 (2}-2Vi
(2)-3 (2)-3 (2)-3
3 (2>-3 (2)-2y2
Pressure
ronulefn*
not
furnished
for
LP
gases
*108103165 manual shut-off size only
2 2 2 2 2 2V2
2y2 2y2 3 3 3
3 <2)-2y2
(2)-2Va (2)-3
(2)-3 (2)-3 (2)-3
iy IV* IV* 1V2 1V2 2
2 2V2 2V2 2Vi 2V2
2y2 3
3 3
3 3 (2)-2y2
2 2 2 2 2 2y2
2Vi 2Vi 3 3 3
3 3
(2)-2y2 (2)-3
(2)-3 (2)-3
(2)-3
lVa iy iy iy2 iy2 2
2 2V2 2V2 2V2 2V2
2V2 3 3 3
3 3
(2)-2y2
2 2 2 2 2 2
2 2 2 2 2
2 2 2 2
2 2 2
American-Standard
16484
7