Document 1QZOVpQMJVDqMMdwd7b8Y24jd
Ver/ar Inc.
1.
WNUFACTU1<ING PPOCRSS - POLYCHLORINATED BIPHENYLS (PCBs)
Process Description
Monsapto, the sole domestic manufacturer of PCBs, manufactures this chemical in their Sauget, Illinois plant. The basic raw material is bifhenyl which is manufactured from pure benzene in another Monsanto plant. The PCB manufacturing operation is conducted in two steps. First biphenyl is chlorinated with anhydrous chlorine in presence of ferric chloride to produce crude PCBs and then the crude PCBs are distilled to obtain the finished product. A schematic flew diagram of this process is given in Figure 1.
Hie reaction section consists of 6 reactors (3 batch and 3 cascade).
Currently Monsanto manufactures four different types of Aroclors (1242, 1016,
1254 and 1221). For the manufacture of any given product, the chlorinator is
charged with proper quantities of biphenyl and catalyst and heated beyond
the melting point of biphenyl. The flew of vaporized chlorine is then started
and the charge is circulated with a pump. Throughout the chlorination, the .
temperature is kept above the melting point of the mixture, but below 150C to
avoid excessive sublimation and plugging of the line discharging the hydrogen
chloride produced by the chlorination. The reaction pressure is maintained near
atmospheric. The degree of chlorination is principally determined by the time
of contact of biphenyl with anhydrous chlorine. The contact tima varies frem
12 to 36 hours for the manufacture of different Aroclor types. The degree of
chlorination i6 measured by the specific gravity of the mixture or the fall
and ring softening point when the product is viscous. .
.
The vapors from the chlorinator (HC1 containing PCBs) are scrubbed with
liquid Aroclor and the gaseous HC1 is sent to another plant at the Sauget complex
for purification. The crude product is held at an elevated temperature and blown
with dry air for several hours, after whi^J) ^t is sent to the raw Aroclor storage
tank where a few tenths of 1 percent of
is stirred with the material to react
with any remaining hydrogen chloride or ferric chloride. The air frem the blcwer
tank is scrubbed with water and vented to the atmosphere through a demister.
Hie raw Aroclor is subsequently batch distilled under reduced pressure to remove the color, and the traces of hydrogen chloride and ferric chloride. The methods of purification are different for the different types of end products.
HONS 056188
BIPHENYL
FeCI,
Figure 1A - Preparation of Crude Chlorinated Biphenyls >tonsanto Krirrrc-icii Plant
1CCOOLER
LIQUID
j__tPCB
HCI TO PURIFICATION
BATCH CHLORINATOR
AROCLOR
a nci
GAS
SCRUBBER
cruoe AROCLOR
IHjO SCRUBBER
BLOWER TANK
DEMISTER
i. ^ ` -Of RAW AROCLOR
STORAGE
RAW AROCLOR
Figure IB - Distillation of Crude Products Monsanto Krtmnrich Plant
GAS FIRED RETORT
VACUUM
OVERHEAD
DISTILLATION
SHELL a TUBE CONDENSER
STEAM
-C h2o vapor
STEAM JET EJECTORS . HjO CONDENSATE
AROCLOR 1016
rlxHCI TO PURIFICATION r-- AIR TO HjO
----------- ------- SCRUBBER (CASCADE REACTORS)
CHLORINATION SECTION
STORAGE
/ DETAILS SAKE \
\ AS A80VE /
NON-CONTACT
COOLING WATER
r
STEAM
i AIR STEAM JET
HgO VAPOR
STILL (VACUUM)
CONDENSER
EJECTORS * HaO
CONDENSATE
-AROCLOR 1254
MONTARS TO INCINERATION
HONS 0 5 6 1 8 9
3.
Raw Aroclor 1254, 1242 arri 1221, each are distilled in stills under reduced pressure, achieved via steam jet ejectors, the condensate from the still is the finished product while the bottoms are the Mcntars which are drummed and sent to incineration.
The distillation section for the 1016 product consists of a gas fired
retort and a vacuum distillation tcwer. Ihe latter is used to allow the separation
Of the higher chlorinated, less biodegradable compounds from the relatively lower chlorinated and more biodegradable ones. Ihe raw Aroclor (42% chlorinated
material) is fed into the reboiler. The vacuum in the tower is maintained at
about 100 nrn Hg via steam jet ejectors. Ihe steam is partially condensed
and the'Condensate is discharged into the plant discharge sump. Ihe first cut
from this tower is recycled back to the retort. At a preset overhead temperature
the 1016 product is collected and sent to the product storage. Ihe high boiling
residue from the tower is sent to a subsequent chlorination cycle and the resuiting raw Aroclor is distilled in a still. The overhead from this still is
the finished product. The bottoms from this tcwer are the Monbars, which are
sent to incineration.
For special orders, in crder to increase electrical resistivity, the Aroclors >
are stirred, at an elevated tenperature, with a few tenths of 1% of well-dried fuller's
earth and then filtered through paper.
.
-
All Aroclors are stored at 150F. Steam coils are used on the storage tanks for heating these tanks. Plant Water Usage
On the average, the PC8 plant uses a maximum of 388,800 gallons of water and a maximum of 120,000 lbs of steam, daily. Water is used for non-contact cooling purposes in shell and tube condensers, in a water scrubber, for floor washings, for shoWers and in eye baths. Steam is used in the stean jet ejectors and for steam tracing purposes. The plant uses municipal water and purchased steam.
Ihe process water from this facility consists of the liquor from their scrubber and the steam condensates which are discharged in one of the two sumps in the manufacturing area.
Additionally, 273,600 gallons of water is used in the incinerator, daily for quenching the hot gases from the fire box. The resulting weak muriatic acid in the quench pot is used in the venturi scrubber and in the packed tower.
HONS 056190
er/ar Inc.
The type and quantities of water used and discharged at this plant are summarized belcw.
Water' Balance
'
Manufacturing Plant
Process Water in water scrubber shcwers, eye bath misc. floor wash downs1 condensate from steam jet ejectors
Non contact cooling water Condensate from steam tracers
Total
Incinerator water used for hot gas quenching water phase from the sump
. Total
Used 14,400 7,200 7,200
--. 360,000
__ 388,600
273,600 --
273,600
Discharged 14,400 7,200 7,200 14,400
360,000 28,800
432,000
273,600 14,400
288,000
Raw Wastes
The rew wastes from the manufacturing area consist of the liquor from the scrubber, the condensate from the steam jet ejectors, water used for showers and eye baths, miscellaneous floor wash cfcwns and waste oil collected in drip pans and drums. The composition and the quantities of the individual waste stream are not monitored. All waste streams generated in the manufacturing area are directed into the -samps in this area. The waste oil collected in the drip pans are emptied into 55 gallon drums and sent to incineration.
Tire raw wastes generated in the incinerator consist of the venturi scrvbber liquor and the water phase from the separator sump in the incerator area. The composition of the combined stream is monitored. However, the composition of the individual stream is not known. Non-product PCS discharges are Bhown in Figure 3.
HONS 056191
HONS 056192
Figure 3 - NcrrfTodrct PCB Wsdiarges at Mansanto's Krumarich Plant
VAPOR FROM JET EJECTORS-----------------------EXHAUSTS FROM THE SCRUBBER---------------SURFACE AREA EVAPORATION (IN GENERAL)
CONDENSATE .FROM STEAM EJECTORS NON-CONTACT COOLING WATER-----------SCRUBBER LIQUOR ----------------------------------
MONTARS ------------------------------------------------- -- BOTTOMS FROM SEPARATOR SUMP-----COLLECTION FROM ALL DRIP PANS
RAGS FOR CLEANING------------FLOOR DRY------------------------------SPENT FILTER PAPERS & FULLERS EARTH------------:-------
(
TO SEWERS
INCINERATION
LANDFILL
Ln
YerJar Inc.
6.
Waste Water Treatment and Housekeeping
Monsanto reports significant envircnrrental oontrols at their Krutmrich, Sauget plant. Since 1969, they have invested more than 22 man years of work and millions of dollars in this program. The in-house goals have reduoed the PCB discharges into water and air to less than one pound per day, each.
A John Zink designed incinerator was erected at Sauget in 1970 to safely dispose of PCBs. A schematic flew diagram of this operation is given in Figure 2. Aroclor is steam atomized and fed into the fire box. Natural gas is used for oonbustion and the feed is incinerated at temperatures above 2200F at 5% excess oxygen with a retention time of 2-3 seconds. The gases are quenched with water and the 'exhausts from the quench pot are passed through a high-energy venturi scrubber, then through a packed column which is irrigated by the weak muriatic acid originating from the quench pot. Exhausts are then vented to atmosphere through a demister. These exhausts as well as the effluent frem the Incinerator section are monitored.
. In the incineration area, drainage i$ directed to trenches arri piping which flow into a 10,000 gallon underground concrete basin. The water layer from this basin is punped continuously, cenfoined with tie scrubber liquor, metered, monitored, and discharged into the sanitary sewers of the Sauget complex and from there it is sent to the East St. Louis municipal sewers. The organic phase from the surrp is periodically pumped into waste storage tanks for incineration.
The incineration unit has a rated design capacity of 10 million pounds per year. Hcwever since the start of its operation this unit has achieved a service factor of about 0,6. Monsanto reports that this incinerator oan achieve a maximum of 6 million pounds of capacity annually. This unit is plagued with various mechanical problems.
Monsanto uses their incinerator to process both their own wastes arri as a service to other industries. The service charge for incineration is an average
of 50 per lb of material.
The incinerator feed is brought into the plant either by truck, in 55 gallon
sealed drvms, by tank trucks or by rail. The drums are opened, picked-up by a fork lift and emptied into a concrete pit. The tank truck carrying the waste liquids
enters the incinerator area and the liquid waste is then pumped from the truck into the pit. The material in this pit is periodically punped via a vertical centrifugal pimp in one of the four 20,000 gallon, each, incinerator waste feed
tanks.
HONS 056193
Figure 2 - Process Flew Eiagram of the John Zink
Incinerator at liorsanto's
Krtraaricii Plant
'
MONS 05619*
8.
The rail truck is brought into a designated area close to the incinerator site. The material frcm the rail truck is normally pumped into a lcnq term, 500,000 gallon storage tank. The material from this tank is pumped into the incinerator feed tanks located on the incinerator pad, when required.
Drainage is provided along the rail tracks. These drains empty into the 10,000 gallon sump located under the incinerator pad.
In the manufacturing area, Monsanto has taken a number of significant steps to prevent loss of PCBs to the environment. Drainage is directed to trenches and piping, and then to cne of two concrete 3,000-gallon underground settling basins. This injures PCB containment in case of accidental spill or equipment failure. Belief valve lines and atmospheric vents are routed through catch tanks, or are redirected to settling basins.
When small quantities of PCBs are collected in the settling basins of : the manufacturing area they are later pimped into 55 gallon drums, and eventually incinerated. The overflew frcm these sumps is ccnbined with the non-contact cooling water used at the plant, monitored and then discharged into the Sauget complex's sanitary sewer and from there to the East St. Louis municipal system.
PCBs are packed and shipped in galvanized-steel 55 gallon drums, in tank oars or in rail cars. All rail cars are top loaded. In the drum filling area spills are cleaned via rags or floor dry and these materials are drummed and sent to landfill located in the town of Sauget.
In the PCB truck or rail oar loading area drainage is directed into a small concrete pit. The material accumulated in this pit is periodically pumped into the basins located in the manufacturing area.
Nitrogen blanketing is provided on storage tanks to eliminate ary "breathing" of the tanks and rpsultant PCB escape.
Mist eliminators have been installed in vapor lines to eliminate the possibility of PCBs leaving the manufacturing area through these lines.
Finally, underground sewers have been replaced with above-ground sewers, and repaired or combined with others, so that the effluent from the department can be monitored. In addition, this step will prevent any unknown buildup of PCBs in the sewer systems or any contamination of PCBs into other sewerB.
HONS 056195
9.
A high housekeeping level is maintained in the plant itself. Housekeeping responsibilities which the operators have assumed are as follows:
-- All pump3 are checked for leakage on every shift. Drip pans that collect leaks are enptied into scrap PCB drums.
-- All leaks are reported and documented so that corrections can be made and settling basins observed.
-- "Floor Dry" is used to absorb any PCBs that have spilled or leaked. If it becomes neoessary to flush PCBs to the settling basin, a minimum amount of water is used.
--Sampling drums and scrap PCB drums are quickly palletized, labeled . and transferred to the incineration area.
Treatment Posts
Hie installed cost of the incinerator system is reported to be $950,000. The annual operation cost of this unit is $600,000 of which $200,000 is for maintenance. This unit employs a crew of five cn a 24 hr operating day basis*.
Plant Effluents
.
This plant has no point source discharge from their operation. There is a single discharge from the manufacturing operation (the cabined stream of prooess and non-oontact oooling water) to the main sewer system of the Sauget complex and their is a second discharge from the incinerator area to the seme sewer system. The ocnposition of these streams as reported ty Monsanto are as follows:
Effluertt from the Manufacturing
Operation
Effluent from the
Incineration area
flew rate, gpd
.
Alkalinity, mg/1 BOD, 5-day, mg/1 Chemical oxygen, mg/1
TS, mg/l IDS, mg/1 TSS, mg/1 TVS, mg/1 Ammonia, mg/1
432,000
288,000 yjb
06b
(*N) Kjeldahl Nitrogen, mg/1
Nitrate AsN, rog/1
Phosphorus Total, mg/l
Oolor (As P)
Turbidity, trg/1
Total hardness, mgA Organic Nitrogen, mg/l
Sulfate, mg/l
Sulfide, mg/l
Chloride, mg/l
Cyanide, yg/1
Fluoride, mg/l Aluminum - total, yg/1
Boron - total, yg/1
Calcium - total, mg/l
Chromium - total, yg/1
Cobalt, total, yg/1
Copper - total, yg/1
Iron - total, yg/1 Lead - total, yg/1
Magnesium - total, yg/1
Manganese - total, yg/1
Mercury - total, yg/1
Molybdenum - total, yg/1
Nickel - total, yg/1
Potassium - total, mg/l
Silver - total, yg/1
Sodium - total, mg/l
Tin - total, yg/1
Titanium - total, yg/1
Zinc - total, yg/1
Oil & Grease, mg/l
Phenols, yg/1
Surfactants, mg/l
Chlorinated hydrocarbons, mg/l (except pesticides)
PCBs, yg/litor
10. . .
HONS 056197
War Inc.
11.
Treatment Facility for the Sauget Oomplex
Monsanto Is In the process of building a solids removal, primary treat ment plant for the treatment of the sewer effluent at the Sauget complex. This plant is due to completion in 1976. A secondary treatment plant for this effluent, which will consist of a neutralization operation, is in the planning Btage at the present tine. This latter project is due for completion in 1978.
Additionally, a regional biological treatment plant is also in the planning and negotiation stage. The completion date of this project is not known. How ever, Monsanto will have access to this treatment facility and will utilize this plant as a tertiary treatment stage for the sewer discharge from the Sauget complex.
>i ~r-
,1K ft**"
o tisOtx. c/>r eN/y C 6
o' /
tCrf*
< `htfA l IV
HONS 036198