Document 1QXrxE61Kyq05bMXj5q8d332o

"JJ ` /l - T (Al'_______ REPORT HO. 2892 INTERIM REPORT OH AROCLCR IN GASES Job No. 171-1089 June 17, 1953 H. B. Richards, Jr. RESEARCH DEPARTMENT Phosphate Division . -2892 JffiOCLCR IN GASES Monsanto N6V 129734 WATER PCB-00052630 Report No. 2892 INTERIM REPORT ON AROCLOR IN GASES ' Job No. 171-1089 File No. UiVwiot\ 1 Work Started; 5-8-53 Work Completed; 6-16-53 Report Submitted: 6-17-53 Prepared By: H. Be Richards, Jr. Chemists: A* M Ellenburg He Be Riohards, Jr* 18 copies were made of this report and distributed as follows: No. 1 No. 2 No. 3 No. 4 No. 5 No. 6 No. 7 No. 8 No. X "No. 10 No. 11 No. IS No. 13 No. 14 No. 15 No. 16 No. 17 No. 18 Research File R. Le Jenkins - St. Louis J. L. Chrlstlan-T. K. Smith H. F. Weaver - St. Louis C. A Hoohwalt - St. Louis N. N. T. Samaras - Dayton E. E. Hardy A. M. Ellenburg H. B. Richards, Jr. P. G. Benlgnus - St. Louis Re E. Kelly - St. L uis P. 6 e Benlgnus - St. Louis P. G. Benlgnus - St. Louis P. G. Benlgnus - St. Louis P. G. Benlgnus - St. Louis P. G. Benlgnus - St. Louis St. Louis 1297^5 Ni'i This Is Copy No ]This report and the information contained herein is the property of MONSANTO CHEMICAL COMPANY WATER PCB-00052631 P_N XA h This report and the Information contained herein is the property of the Monsanto Chemical Company, and should he considered confidential. It should he retained by the recipient* and not copied or loaned to others. 129736 WATER PCB-00052632 ( TABLE OF CONTENTS EfiggJio* I* lie III# IV. V. Vie VII. Introduction Summary ...................................... .... . References ...................................... . . . Experimental Work............................ A. Experimental Bata ....... Be Negative Results . . e e . . . . C Precision and Accuracy..................... Disoussion e ................................. * . e . Conclusions . . . ............................ . Recommendations . ................................. .... Appendix Sampling Positions........................ .... . Operating Procedure for Willson Product's, Incorporated, Chlorina ted Hydrooarbon Sampling Apparatus Data Sheet - Aroolor Vapor Detection .tee........ Diagrammatic Sketch 1 1 Z Z Z 3 3 .. 3 5 5 7 7 8 IS 13 NEV 129737 WATER PCB-00052633 -1- INTRODUCTION! DcoizweCr hi>ientrm; isctaylreCnoemplaantyexis interested in paint systems. using Aroolor as Research at the a plasti Plastics Division)?s Springfield laboratories has indicated that use of suoh paints in enclosed areas under certain conditions results in Aroolor vapor concentrations above the accepted safe maximum for continuous exposure. For this reason Dow is dubious about the use of Aroolor for this application. The Sales Departmentp therefore, requested that experiments be oarried out in the Aroolor plant at Anniston to determine the Aroolor vapor concentration to whioh the operating personnel are norqially exposed. This data can then be submitted as evi dence that exposure to this concentration has had no apparent toxic effects upon the operators. This work was undertaken to determine the usual Aroolor vapor concentrations in the plant, II. SUMMARY; The chlorine content of the air in the Aroolor plant has been determined at several positions and tinder various conditions, Willson Produotfs, Incorporated,, apparatus for determination of chlorinated hydrooarhons was employed for these tests, (See Append! c) The Aroolor vapor concentration was found to vary widely depending upon several factors including location of sampling apparatus, operations being carried out, directions of drafts through the still room, and temperature and boiling point of the Aroolor under question The aotual Aroolor vapor concentrations varied from about 0,555 mg, per cu, meter to about 5.0 mg, per ou. meter under the most severe conditions. No definite average concentration has been established. It was found, however, that the Aroolor vapor concentration in the air. at the sample points is seldom below the 0,5 to 1,0 mg. per ou, meter level, whioh is the maximum tolerable con centrations (aooording to Elkins, see References). and often is as high' as 3 to 5 mg, per cu, meter. These higher concentrations are.extjremely irritating to the eyes, nose, and throat. On the basis of these facts it is difficult to conceive that concentrations In the range of 1 to 5 ng. per cu, meter reported by the uPlastios Division as a result of painting with an Aroclor- containing paint could be attained under normal conditions with this type paint. It should be further noted that nearly half the te^ts in the plant showed less than 1,0 mg, Aroolor per cu. meter, and about two thirds of the tests showed less than 2,0 mg, Aroolor pbr cu. meter, and only about 5.0 mg. per cu. meter under the most severe conditions. It is reoommended that this laboratory secure a sample of the paint under question and make tqsts with it to determine the resulting Aroolor vapor con centration in the air. NEV 129738 WATER PCB-00052634 Sampling of the air in the plant will also be continued until more complete data are obtained on all of the Aroclors. m* 3FEREN0ES; Jacobs', Mo Bo, "The Analytical Chemistry of Industrial Poisons, Hazards , and Solvents," second edition, Intersolence, New York City, 1949* Millhiiser, F* Ro, "Determination of Halowax in Air," Report from Dept, of Physiology, Harvard Sohool of Publio Health, Bosto1n, Mass, Sept., 1936. Monsanto Chemical Company, Plastios Division, Confidential Report; on Aroclor Vapor in Air From Paints, Deo., 1952, {no report' number assigned) ElkinJ, Hervey B., "The Chemistry of Industrial Toxicology," John Wiley & Sons, New York, 1950, page 149. IV. EXPERIMENTAL WORK; The apparatus and operating procedure are described in the Appendix to this report, A description of the various sampling positions together with a sketch of the Aroclor plant |floor plan may also be found in the Appendix, A. Experimental Data; TABLE I AROCLOR V.APOR CONNCENTRATION IN AS. , AROCLOR 1860 Test Position Concentration, mg./ouVm. Remarks No,, No, Chlorine Aroclor 11 5 0,38 0.53 Still in operation. 13 4 0.55 0.98 Still open. 14 5 0.58 0.87 Still open. 15 6-S 1,5 2.5 Filtering at 125C. 16 6-N 1.2 2.0 Filtering at 125C. 18 5 0.22 0.36 Still in operation. 19 4 0.91 1.5 Still open. 20 .. 4 0.75 1.2 Still charged and started 81 4 0,53 0.88 Still in operation. 8 ____8,8 4.6 Drumming 1260 at 150C,___ NEV 129739 WATER PCB-00052635 TABLE II AROCLOR VAPOR CONCENTRATION IN AIR AROCLOR 1242 AND 1354 Test Position Concentration. Mg./cu.m. Remarks No. . Chlorine Aroclor 10 5 0.14 0.33 Still open. 89 4 1.5 3.6 Still operating. 30 5 1.5 3.6 Still operating. 31 6-S 8.8 5.3 Press not operating and cold. 1248 in No. 8 B. at 110C. . . 85 . 5 0.41 0.76 Still operating. 87 5 0.50 0.98 Still operating. Note: All tests on 1848 except 85 and 27 which were 1254. TABLE III AROCLOR VAPOR CONCENTRATION IN AIR MISCELLANEOUS Test Position Concentration, mg./ou.m Remarks No. No. Chlorine Aroclor 17 9 0.21 - Atmosphere blank, north of building. 23 9 0.32 Atmosphere blank, north of building. 82 7 1.1 24 10 0.68 2.2 At operators' desk. 1.4 At steam recorder, north end of room. 13 Reagent blank 0.006 mg. Cl" in washing s. 26 Reagent blank 0.007 mg. Cl" in washings. Bo migative Results: Tests numbers 1 through 9 were discarded. These runs were used for familiarization and establishing a satisfactory analy leal procedure C. precision and Accuracy; The method used in these determinations has been claimed to have over-all acouraoy of within 3$ to 5# (see Millhiser, under| References) Y. DISCUSSION In Table I the most severe concentrations were encountered durink three different operations on Aroolor 1860, charging the still, filtering, and drawing out the hot Aroclor into drums. These three operations constitute the greatest ex- posurp to which the operator is normally subjected, plus the . NEV 129740 WATER PCB-00052636 -4- exposure at the desk where the oonoentration was fairly high as seen in Table III* The drumming operation is the most severe of these sinoe the oonoentration is highest and the time to which the operator is exposed to this concentration Is usually In the order of 3 to 6 hours as oompared to about 30 minutes for any of the other operations. The Aroolor vapor concentrations during the distillation operation varies from about 0,5 to 1 mg, per ou, m. The Aroolor vapor concentrations were calculated by assuming 60$ ohlorine in the vapors. Actually the chlorine content of the vapors is probably lower than 60$ since the lower boiling (and therefore lower ohlorinated) components of the Aroolor are vaporized more readily than are the higher ohlorinated components. This assumption then makes the values for the Arodlor vapor concentrations minimum values, sinoe a lower ohlorine content would give higher values for the chlorine containing material. This same faot applies to Table II, In Table II the effect of the degree of chlorination (and therefore of boiling point) is indicated by the high concen trations found during IB42 operations. The concentration in test No, 10 was low, but the still had been shut down for about 7 hours when this test was made. It is noteworthy that the high concentration found in test No, 31 was during the earnh treatment of a batch of Aroolor 1848, hut not during a filtration. The intake to the sampling apparatus was about 8 ffrom the closed hatch of the tank in which the Aroolor was being treated at 110C. There was a gentle draft through the room in the direction from the operating equipment toward the sampling apparatus. The Aroolor vapor concentration under theiie conditions was extremely high. Also, the concentrations in iests 89 and 30 were quite high in comparison to that found under the same conditions for 1860, These tests were made on the upwind side of the Aroolor treating tank. However, tests 85 And 87 on Aroolor 1854 under very similar conditions showed muoi lower vapor concentrations. Further tests are required to determine whether the high vapor concentration encountered during these tests on 1848 are usual, or whether the ohlorine absorbed in the apparatus might have been from another source. TabLe III gives some miscellaneous tests and blank determina tions. Testji 88 and 84 show presence of considerable concen trations of roolor at points in the room relatively remote from any of the operating equipment. The operators desk is located at the head of an open stairway and quite possibly is exposed 'to much ohlorine bearing material blown up the stairway by the'draft through the builditlg. The Aroolor vapor conoen tratioin on these two tests was estimated by assuming 50$ ohlorine in the vapors. Blank determinations were made on the reagents and on the atmos phere outside the Aroolor plant. These values are tabulated in liable III. NEV 129741 WATER PCB-00052637 -5- From diese data it may be seen that the Aroclor vapor concen tration in the plant varies from about 0*5 to 1 mg* per ou* meter at the minimum up to about 5 mg* per cu. meter under the most severe conditions* No average concentration or average daily exposure of the operator have been developed from the data so far* Springfield has reported Aroclor concentrations from about 1 to 5 mg* per ou* meter from paints containing Aroclor* It hardl;r seems reasonable that concentrations within this range couldjbe reached under the relatively mild conditions encountered, when the concentrations found in the plant are ordinarily within this range even under extreme conditions* It is therefore recommended that a sample of the paint in question be secured and t >sts made in a room painted with it* It should be pointed out that although the Aroclor vapor con centration in the plant is seldom below the 0,5 to 1 mg*/cu meter level which is the maximum allowable concentration accord ing to Bikins (see References), the exposure to which the opera tor is subjected varies greatly* This exposure depends upon the anount of time actually spent in the Aroclor plant, the operation being performed by the operator, and the Aroolor vapor concentration present at that particular time* All of these factors depend themselves upon several other variable conditions, making the establishing of an average exposure estremely difficult if not impossible* No apparent ill effects have been noted from this exposure over a period of several years'* However, the highest concentrations were almost un bearably irritating to the nose, throat, and eyes* Elkins has mjade these same observations in studies in plants using Aroolior* yi<> CONCLUSIONS: m Aroolor vapor concentration in the plant is almost never below the 0*5 to 1 mg* per ou* meter level, and often reaches about 5 mg* per ou* meter in some locations, 8* !me concentrations reported by Springfield of 1 to 5 mg. per ou* meter from paint containing Aroolor hardly seem reasonable considering the concentrations found in the plant* No average daily exposure may be developed from these qat&o Illi RECOMMENDATIONS; It is recommended that sampling of the air in the Aroclor plant be continued until more complete' data are obtained* NEV 129742 WATER PCB-00052638 - 6- Z, .lit is recommended that a sample of the Aroolor-contanilng paint in question be secured, and that a room be painted with it. Tests may then be made to determine tjho Aroclor vapor concentration in the room resulting from use of this paint. VCM 6w23n53 ft, H, B. Richards, Jr, NEV 129743 WATER PCB-00052639 I -7- SAMPLING POSITIONS Position umberi Description_______________________________ No. 1 still, simulating position of operator's head dur ing oharging operations. 54" from floor on west side of still about 18" from oharging hole* 2. No. 1 receiver, at sight glass, Simula ting position of operator's head. 54" from floor and 18" vest of sight glass. 3. No. 1 filter press; N - northside, S -- south side. 54" from floor and 15" from edge of press when on south side or 9" from edge of press when on north side. Northside looation simulates operator's head position when redressing the filter press. 4. No. 2 still, same as position 1 above. .5. No. 8 receiver, same as position B above 6 No. 2 filter press, same as position 3 above. 7. At operator's desk, 54" from floor and 8" beyond front edge of desk to simulate position of operator's head . when writing at desk. - 8 At scales for drumming Aroclor. 54" from floor and 14" from Aroolor outlet. Opposite side of drum from . operator. 9. Blank determinations as described. 10 Miscellaneous positions, as described. NEV 129744 WATER PCB-00052640 Hun No* - 18 - DATA SHEET - AROCLOR VAPOR DETECTION Dat: Bar* Press.* mmg, Hg.: Looation of intake: Rate of sampling* lpm.: Ambient U mp at intake, C.: General Remarks Duration of sampling* min.: Total vol* of aample* liters: Analysis: Net vt. of washings* gm.s Cl** one. in washings* ppm.: Total Cl" in sample* mg.: Total 01"' in blank, mg.i Cl oono. in air* mg./ou. m.: Aroolor oono. in air, mg./ou. m.: nev v^71*5 WATER PCB-00052641 13 Diagrammatic Skate h AroeJor Si cH Room 60' , 1 cX*>), _1 L H*v*tor Sh*ft (T) ato-sst;// 4S> + NoB Receiver + /Vo. Pt/frai* /Vo, B Bhts 4 facet'/** T*nk ---SHU- M>$ fitter fast M.t ft'//wit /feceV*r - A/o.i. 3/of/ ThttA ' W /Vo, t pi/te,r Prtu iIn Stum focorjtr, I^P O) 0N (D ' A roc/or Stem#* Took (D U/)ofre.j Stk/npkhg Pose'ic'oh 'N r NEV 129746 ScA hi */a * i.O" H.B.R, - 6-22-5S WATER PCB-00052642