Document 1Q7DmzYGJGJkoDLGnN3Yr4EJa

Federal. Register. / Vol. 51. No. 119 / Friday; ..June .-20. 1986 / Rules and Regulations 22695 employees asameans of controlling' exposure. Unprotected exposures above the PEL should not be permitted [Ex. 90-236). mg/M\ well below the cut-off fOr other than high efficiency filters. Many commenters stated that non- prolonged storage at high humidity; The other'respirator filters yielded varying resiilta. Thus) even' Under laboratory Similarly, Richard A. Lemen, Director, powered air purifying respirators should conditions, most'approved respirator Division of Standards Development and be provided with high efficiency filters filters did not provide the consistent Technology Transfer for NIOSH. and that single-use and replaceable protection necessary to ensure worker .. commented: dust/mist respirators do not provide health. Worker rotation as a compliunce measure must beTorbiddcn given the lack of a safe threshold for lung cancer and mesothelioma caused by asbestos (Tr. 6/21. p. 66). adequate protection against asbestos [Exs. 90-49, 90-234, 91-6, 91-40,117E. 123A). Other commenters were in favor of more stringent respiratory protection A number of commenters stated-that air purifying non-high efficiency half mask negative pressure respirators should be permitted to be used as they The prohibition against worker rotation contained in the final standard for asbestos is. .therefore, consistent with OSHA's view that this control strategy is not appropriate in . occupational environments involving exposure to carcinogens.' 7. Paragraph (g). Respiratory Protection. The final standard requires that respirators be used to limit employee exposure to asbestos in the following circumstances: - (i) During the interval necessary to install or implement feasible engineering and work practice controls: (ii) In work operations such as maintenance and repair activities or other activities for which the employer establishes that engineering and work practice controls are not feasible: (iil) In work situations where feasible engineering and work practice controls are not yet sufficient to reduce exposure to or below the PEL; and (iv) In emergencies. These limitations on the required use of respirators are consistent, with the requirements of the past asbestos standard, with 29 CFR 1910.1000 (e) and with good industrial hygiene practice. They reflect OSHA's.determination, as detailed in the preceding section on methods of compliance, that respirators are inherently less reliable than ' such as supplied air respirators or positive pressure respirators to assure the maximum protection possible (Exs. 223, 90-147). . In a letter to all respirator manufacturers published in the American Industrial Hygiene Association Journal, Df.-Jon R. May of NIOSH stated the following: On the issue of asbestos: the Institute wishes to state that although asbestos can produce fibrosis, this effect pales in ' significance in comparison to the known human and animat carcinogenicity of this fibrous material. It is not our position that single-use dust respirators will provide adequate protection against the cancer causing potential of asbestos [Ex. 91-6). Furthermore, in regards to dust, fume, and mist respirators, either with replaceable or reusable filters, Dr. May expressed concern about the filters effectively removing asbestos during the entire period of recommended use. This is based on the fact-that the air-purifying components of these devices are not tested against asbestos but rather against a fine silica dust aerosol. Norton Company) a respirator . manufacturer, stated: To obtain the greatest degree of protection available from non-powered air-purifying respirators, in asbestos environments where the TWA concentration is less than 20 fibers per cubic'centimeter, Norton recommends the use of an elastomeric half-mask or full- reliably provide protection up to ten times the permissible exposure, level (F.xs. 328, 331, 339.341). E.l. DuPont DeNemours and Company submitted for. the record [Ex. 339) a study it conducted on workplace protection factors for elastomeric half-mask and single use respirators. Results of their study showed that five of six respirators tested provided workplace protection factors of ten or greater and the remaining one provided a protection factor of five or greater. Unfortunately this study was not completed in time to present at the public hearing and could not be reviewed and commented upon by other interested parties. Also, DuPont did not submit data to indicate the. magnitude of counting errors in their study. OSHA does not believe that the DuPont data proves that negative pressure air purifying respirators provide adequate protection. The study was based on evaluating only a few manufacturers' respirators. In addition, workplace protection factors obtained appeared to be inconsistent with the types of respirators tested. For instance, the 3M-9910 disposable respirator tested yielded a protection factor almost. equivalent to the Scott Air-Pak (SCBA) tested, and the 3M-9910 far exceeded the protection factor of an elastomeric/ high efficiency filter. engineering and work practice controls. OSHA believes, therefore, that relying facepiece respirator with high-efficiency filters [Ex. 117E). The expected results would be that. the supplied air respirator would have a. on'respirators to control exposures to OSHA acknowledges that respirator higher protection factor than the the PEL must be confined to the . designated situations. filter efficiency for asbestos has not been thoroughly tested (49 FR14125). A negative pressure respirator. The superiority of supplied air respirators is Theifinal standard requires the use of recent study by the Los Alamos recognized by all respiratory selection ' high efficiency Tillers when air purifying Scientific Laboratory (LASL), submitted procedures in existence and conforms tq rcspiratorsare.-tised. OSHA is to the OSHA Socket [Ex. 9.3r5],.has cast OSHA respirator selection tables in all ' particularly concerned1 about the further doubt on the effectiveness of ' toxic substances to'date, including the penetrability of respirator filters . respirators when used specifically to existing asbestos standard, and all (including single use respirators) other -protect against asbestos exposure. Five NIOSH criteria documents) There is' no than the high efficiency type. At the new respirator filters', all of which are explanation for the inconsistent findings PEL.of 0:2 r/cc; the'NIOSH/MSHA ' approved by the Mine Safety and Health in the DuPont studies. certification criteria require the use of Administration (MSHA) and NIOSH for Another factor that must be realized high efficiency filters [See 30 CFR 11.130 the use with asbestos, where challenged when interpreting the results of the (afand (c)|. NIOSH certification for . ' with an aerosol of chrysotile asbestos DuPont study is that the protection other than high efficiency filters is not . under varying environmental conditions. factors reported by DuPont were based valid for. toxic substanCes with PEL - Only one.model (the high efficiency upon data gathered after the workers' values less than 0.050mg/M3 or 2 filter) functioned.consistenlly well under were fit tested. According to industrial mppef. Using the conversion factor all experimental conditions: (1) fresh hygiene practice, if the fit test' provided by CHAP.[Ex. 84-246, p. Il from the package, (2) after exposure to procedures adequately workj lhen no ls?]. a PEL of 0:2 f/cc equales.to 0.006 an organic oil mist, and/or (3) after workers should be expected to have GLEASON-000943