Document 1Q042qok2vxxQRq7xypE7BRpZ

COMMENTS ON PCB METHODS / Method I. Gas Chromatographic Determination of Higher Boiling Homoloaues in Aroclor 1016 and Aroclor 114 2. 1. There should be a clearer definition of how the chromatogram is divided and over what range the elution is recorded. Recommendations: ' a) Describe the division of the chromatogram in terms of a retention index (ASTM's preferred retention parameter E 355-68, p. 1128); eg., all components eluting with . . a -retention index greater than 2400 will be calculated as a "High Boiler." b) In a similar manner the range over which compounds are measured could be described using a retention index window: e.g., all compounds eluting with retention index 100 <1.. <2400 are "Low Boilers," those with 2400 <1^ <36t)0 are "High Boilers." .2 Although pure known materials are generally not available, Dr. Ronald G. Webb, Southeast Environmental Research Labor atory, National Environmental Research Center - Corvallis, Environmental Protection Agency, Athens, Georgia 30601 can provide samples of materials whose compositions have been determined by a combination of elemental analysis, . . -gas chromatography with a Coulson conductivity detector and combined gas chromatography - mass spectrometry. Using these as standards, response factors can readily be determined. .3 The method should provide information on sensitivity and minimum detectable amounts. Refer to ASTM E260-69, p. 748. .4 For precision, five rather than two measurements should be made. . Method II. Polychlorinated Biphenyls in Petrochemicals. 1. In Note 1, there appears to be some confusion of the terms "sensitivity" and "minimum detectable limit." .2 Method Summary: a) Is documentation available to show that compounds elute in boiling point order? It is generally accepted that the free energy of solution determines elution order in gas-liquid partition chromatography, rather than the ' boiling points. 0079782 TOWOLDMONOQ56998 b) Many hydrocarbons with functional groups show strong electron capture response. 3. It seems that 100 yl is an awfully large sample to inject on to a 3.5% loaded column. That much material would probably kill the response of a Nib electron capture cell. .4 Retention parameters should probaoly be expressed in terms of retention indices. Refer to ASTM E 355-68. . .5 Provide some information on precision, accuracy, and sensitivity measurements as per ASTM E 260-69. 6. We have found that PCBs are adsorbed readily on untreated glass surfaces. Serial dilutions should not be made in - glass containers unless the glass is properly pre-treated. 0079783 TOWOLDMON0056999