Document 1N35KJv27L1rZEN7LRvY1ZDo
828
CHAPTER 52
1965 Guide And [Data;8ook
oyer the heat exchanger and through the duct work distribu tion system- A fuel-burning warm air furnace consists of the following Kmii*. components: (1) the heat exchanger, (2) com-, bustion or fuel-burning equipment including burners, grates, etc., (3) curing or-cabinet forming the enclosure, (4) .blower and motor, (5) air filter, and (6) other accessories such as a humidifier, electronic air cleaner, etc.
The furnace may be designed and manufactured.to combine those components in a variety of ways to best suit the end use. The relative positions of the components in the different
types of furnaces are described .betow:
.
1. The horizontal furnace (Fig. 1) the blower located behind
the heat exchanger with the air entering one end and traveling
horizontally through the blower and over the heat exchanger and
discharged out the opposite end.
_ / '.
Such furnaces are used for locations with limited' head room,*
such as attics, crawl spaces below floors dr suspended-under the
ceiling. These units are often designed so that the components
maybe rearranged so that air flow.may be from left to right or
from right to left.
2. The' vpfioa or high-boy furnace' -(Fig. 2) has' the blower
beneath .the heat exchanger discharging vertically-upward. Air
fig-: 3
Basement (Low-Boy) Forced Warm Air.Furnace
enters through the bottom or the side of the blower compartment
and leaves at the top. Such furnaces may be used in utility, rooms
on the first floor of homes without basements or in'basements with
the return air ducted down to the blower compartment entrance.'
3. The basement orUrw-boy furnace (Fig. 3) is a variation of-the
upflow furnace and requires less head room. The blower is located
along-side the heatexchanger at the bottom. The air enters,the top
of the cabinet,, is drawn.down through the blower, discharged
over the heat exchanger and leaves vertically at the top. ' ' ' '
4. The downflow or cOtmUrftoto furnace (Fig. 4) has the blower
located shove the heat exchanger discharging downward. The air
enters at the top and is discharged .vertically at the .bottom.*
This style furnace is used with a perimeter heating system' in a
bouse without-a basement.
....
i"
a. a. inlet
WARM AIR OUTLET
Fig. 4 .... Downflow (Counterflow),;, Forced Warm Air R^rnace,.
Heating Boilers, Furnaces, Space Heaters
829
Gravity Furnaces
While most furnaces today are of the forced air type with a blower, many gravity furnaces are still sold and a large number are being used at the present time. The gravity fur nace has the air passages through the casing or cabinet and over the heat exchanger more generously proportioned so that the convection currents created by the air being warmed furnishes the motive power for the circulation of the air through the ducts. Filters are not used with, gravity furnaces cinnft the resistance to air flow must be kept as low as pomible.
DESCRIPTION OF COMPONENTS
Heat Exchanger
The fuel being used has a definite influence on the design
of the heat exchanger. In a coal furnace, the heat exchanger
must include storage space for the burning fuel and ash in
addition to combustion space. In gas or oil furnaces where
the fuel is burned as rapidly as it enters the heat exchanger
some space is required for burners or a combustion chamber
but less space is required for combustion. Sufficient combus
tion volume must be allowed for the requirements of the fuel
being used. Most heat exchangers have a primary combustion
volume and secondary flue-gas passageways in which the
products of combustion are brought into close contact with
the heat exchanger surfaces.
In a coal furnace, where the resistance of the fuel bed must
be overcome by chimney draft, the total draft requirement
of the appliance is greater than for oil burning, for which only
a slight draft is required in the combustion space, or for gas
burning for which the appliance requires no chimney draft ex
cept to remove the products of combustion from the furnace
outlet
Flue-gas passages must be readily accessible for elaaning,
when coal or oil is burned, for the purpose of removing'soot
and scale. In gas furnaces they must be accessible for elaaning
where: (a) the products of combustion are.drawn below the
level of the burner, (b) the temperature of the combustion
products is less than 250 F when the furnace is operated at
normal test pressure with the gas rate within plus or minus
2 percent of the manufacturer's hourly Btu input rating, or
(c) the width of any flue-gas passage is less t.h*.n 1} inrho-a
Flue-gas passages in coal-burning furnaces must be larger
than for other fuels due to a greater volume of flue products
as well as their tendency to collect soot (especially when burn
ing soft coal).
*.
The majority of the furnaces for coal, gas, or oil firing are
now made of hot- or cold-rolled low carbon steel with welded
seams. Some welded coal furnaces also have the joints riveted
since they can be more subject to overheating than oil or gas
furnaces in which the combustion rate is carefully controlled.
Frequently, in heavy duty furnaces, alloy steels containing
chromium and nickel may be used for higher temperature
operation. Heat exchangers may also be protected against
oxidation at somewhat higher temperatures by ceramic coat?
mg or by the use of aluminized steel in which the aluminum
coating changes into an iron-aluminum alloy which will
withstand higher temperatures than the low carbon steeL
Publications of the American Gas Association and under
writers' Laboratories give the maximum allowable tempera
ture for the various materials commonly used.
Combustion Equipment and Performance
Gat. Gas-designed furnaces may bum natural, manufac?
tured, mixed, liquefied petroleum, and liquefied petroleumair gases.
Most residential gas furnaces are equipped with one of two heat exchanger types. Either a single combustion chamber, is used (usually cylindrical in shape) with extended flue-gas pas sageways which may be adjacent to the combustion chamber or encircle it, or the heat exchanger may be made of a series of individual sections connected near the bottom-and con nected to a common flue-gas breeching at the top.- The former design will usually be equipped with a burner of the single port design and the latter, known as a sectional furnace, will usually have individual burners under each of the fluea, cross-connected to ignite from a single pilot burner ignition source.
OiL Oil furnaces consist of a single primary heat exchanger plus additional flue-gas passageways which provide secondary heating surface. In residential furnaces, the high-pressure, low-pressure, and rotary burners are most frequently used.-
'With the pressure-type burners, it is usually necessary to provide a combustion chamber that will keep the tempera tures in the combustion zone high enough to promote rapid vaporization of the oil and at the same time protect the side walls of the heat exchanger from the flame temperature. Insulating-type refractory either in molded or felted form or high-temperature chrome-nickel steel may be used. ..
In heavy duty furnaces, it is often possible to bum the flame in suspension without the aid of an inner combustion chamber. In this case the heat exchanger itself will be made of chrome alloy steel in the combustion zone.
Most furnaces designed for oil are available as complete packages including the furnace and the oil burner. In .the smaller sizes, they are completely assembled at the factory and are shipped ready for installation.
Casing or Cabinet
Forced air furnaces for both oil' and gas are enclosed in
cabinets that are usually rectangular in shape. The cabinet
provides the `passageway for the air over the heat exchanger
and also usually encloses the blower, motor, filters, burners,
controls, and draft hood.
The cabinet is insulated in the heat exchanger compartment
with aluminum-faced mineral wool or asbestos or by a metal
liner to assure cabinet surface temperatures that are not
dangerous to touch and do not offer a fire' hazard to adjacent
combustible materials. Cabinets are usually finished in baked
enamel. Flanged openings are usually provided for supply
and return air duct connections. Removable access doors`or
panels are included for access to all parts.
'
Blowers and Motors
Centrifugal blowers with forward-curved blades of the double inlet type are almost exclusively used as the air circulation mwuw in forced warm air furnaces. These blowers are selected to overcome the resistance of the furnace air passageways as well as the resistance of- the filters and the duct work. They may also be sued to provide the additional air requirement for cooling and to overcome additional static resistance through cooling coils.
The blower wheel may. be mounted directly on the motor shaft to ran at motor speed but it is usually belt-driven by a V-belt in which case a fixed pulley is mounted on the blower shaft and a variable?pitch drive pulley is mounted on the motor shaft to permit adjustment for proper , fan speed. Means are provided for shifting the motor position to obtain proper belt tension after pulley adjustment.
The electric motors used for driving furnace bloweraare usually dasigned for that specific purpose. Since the blower does not pick up its full load until it is up to operating speed, *