Document 19g4JLZ03qe3nG8xYwLR1q
Monsanto
i
Vrf
A report to engineering executives on a new nonflammable type hydraulic fluid.
DSW 321901
STLCOPCB4073551
l i
):
l
\ i'
I i l
t
Monsanto
i. . ... .
DSW 321902
STLCOPCB4073552
Monsanto Pydraul F-9 is an altogether new type hydraulic fluid developed
primarily for use in die-casting machines, hydroelectric turbines, glass
drawing machinery, hydraulic presses, and in other equipment where a
nonflammable-type pressure transfer liquid is required.
'
Pydraul F-9 has nine major properties that recommend it as an outstanding hydraulic fluid. Chief among these is its safety. In a growing number of hydraulic applications where a flammable fluid is hazardous, Pydraul F-9 is recognized as another forward step in the development of pressure transfer fluids. ,,
Engineers are specifying Pydraul F-9 for uses that extend over a wide range of applications. It is apparent that its unique combination of properties recommend Pydraul F-9 for uses more diversified than the current applications for which it has proved so successful.
Since hydraulic fluids are essential to so many diverse types of equipment, this booklet has been prepared to acquaint engineers, maintenance men, and manufacturers with Pydraul F-9. It describes those characteristics of Pydraul F-9 which may recommend it for use in applications known only to engineering executives whose projects require a nonflammable-type, pressure-transfer medium. For further information on Pydraul F-9, itself, or for data that may be available from experience with its present applications, you are cordially invited to write or call Monsanto.
.
: I -
.
H
1. Fire Resistant 2. Exceptionally High Lubricity
3. Noncorrosive A. Chemically Stable
5. Nonreactive 6. Excellent Pumpability 7. Contains No Water or Inorganic Salts
.8 Insoluble in Water
9. Nonvolatile--Does Not Evaporate
*Trd Mrk Ur*. U. S. |-t. Off.
DSW 321903 x
STLCOPCB4073553
Chemical and Physical Characteristics
APPEARANCE
Clear, oily liquid
COLOR
Light amber (APHA 350)
5PECIFIC GRAVITY
1.266
WEIGHT PER GALLON
10.56
ACIDITY (mg. KOH/mg.) '
Less than 0.1
ODOR
Mild, pleasant
POUR POINT
+5F.
HYDROLYSIS STABILITY
Neutralization Number: Less than 0.1 before and after hydrolysis.
VISCOSITY AT 100'F.
49.5--58.0 Centistokes 229--268 S. U. S.
AT aiO'F.
5.6--6.0 Centistokes 44.5--45.8 S. U. S.
2
FIRE
Pydraul F-9 resists ignition under -- conditions that far exceed what would
normally be encountered in use. For this reason, Pydraul F-9 can be considered
nonflammable for all conditions normally encountered in use as a
hydraulic fluid. Pydraul F-9 was subjected to the following tests and performed with
the results indicated:
DSW 321904
STLCOPCB4073554
PYD R AU L
* ila
R E S 1 S TA N T
-
TEST
AUTOGENOUS IGNITION TEMPERATURE (ASTM Method D:286-30)
MOLTEN METAL IGNITION TEMPERATURE
Apex Alloy No. 39* was heated until molten (approx imately 1,500=F.) and Pydraul F-9 was sprayed, dripped and flooded onto the surface of the molten metal.
HIGH-PRESSURE IGNITION TEST
The mist from spraying Pydraul F-9 through a small orifice under 1,000 p.s.i. was subjected to the flame of an oxyacetylene welding torch.
LOW-PRESSURE IGNITION TEST
Pydraul F-9 was sprayed at low pressure (approxi mately 100 p.s.i.) across a flame produced by a burning rag saturated with engine oil.
CONTACT IGNITION TEST
Pydraul F-9 was dripped onto the surface of a hot manifold.
ARC IGNITION TEST
Pydraul F-9 was sprayed through a
petcock at
varying pressures up to 200 p.s.i. through a carbon arc
that had free arcing distance of approximately 1J^".
STATIC CARBON ARC TEST
A metal pan was filled to a fluid depth of approxi
mately
and the arc struck between the electrode
and the bottom of the pan, passing through the fluid.
The arc was sustained for approximately 30 seconds
during which time the carbon electrode became
white hot.
Ap Smelting Company 2537 West Taylor Chicago 12, lllinoia
.
-
RESULTS Greater than 1,100"F. Fluid did not flaih or Ignite.
Evon when exposed to the hottest portion of the oxy acetylene flame (approximately 6,000F.) the fluid did not flash or Ignite. Did not increo*e tho intensity ot the fire*
Did not burn ot 1,100F, nor when the surface tempera ture was Increased to 1,475F# At no time was a flash observed, nor did the fluid burn.
No flash was observed, nor did tho fluid burn.
Dsw 321905
3
STLCOPCB4073555
r
HIGH
LU BR ICITY
Pydraul F-9 can be depended upon for out standing lubricity, reducing wear on moving parts to a minimum. High film strength, instant mobility and good viscosity index insure longer life for bearings and mating surfaces. The film strength of Pydraul F-9 as determined by seizure load on a Timken machine is 17,000 p.s.i.
The following data shows the lubricating ability of Pydraul F-9 when tested in a Vickers vane pump, Type V-105A. Two pumps were operated in parallel; one was operated on a standard petroleum-base hydraulic fluid, the other with Pydraul F-9.
During the test, the pumps were operated at 150F. ( 5) for 16 hours a day, 5 days a week. This interrupted operation was deemed more stringent than. 24-hour operation because of the greater wear to be expected from frequent cold starts. For the first 400 hours, both pumps operated at 1200 r.p.m. at 1000 p.s.i. delivering 4.76 gallons per minute. After 400 hours, the Pydraul-operated pump was stepped up to 1500 p.s.i. for 126 hours; then, for the next several hundred hours to 1800 r.p.m. at 1500 p.s.i. delivering 6.5 to 7.0 gallons per minute. After 800 hours of this operation, the pump was dis mantled and the parts checked for weight loss. The summarized results shows that the weight change was less than the margin for experi mental error.
Vickers conducted an accelerated life test in a piston-type pump at 2000 p.s.i. They reported results indicating no more than normal pump wear in this test.
&
4
STLCOPCB4073556
PYDRAUL
PYDRAUL F - 9 PUMP TEST RESULTS SHOWN ON COLOR
PETROLEUM HYDRAULIC FLUID PUMP TEST RESULTS SHOWN ON WHITE
ACCUM. TIME (Hr*.) PUMP SPEED (RPM)
0
0
.... ....
200 200 1200 1200
400 400
1200 1200
526.8
1200
800 1800
PUMP PRESS. (PSI)
VANES (total)
C
3
miOn ROTOR RING
*
zMz ROTOR
Ok
X SHAFT END
ft.O (Bushing)
f5iL
HEAD END (Bushing)
z
o
VIS. (cks.) at 100F.
5
z
o
V
o 5
VIS. (cks.) at 210F.
m* '
NEUT. No. mg. KOH per gr.
..*
e*
.
37.208gm
34.168
202.6gm
199.0
322.9gm
325.1
176.982gm
180.448
178.433gm
179.831
56.8
64.0
5.98
6.97
0.04
0.02
1000 1000 --.002
--.003
+ 0.4 -0.1
-
--2.9 + .009 --.014
--.002
--.015 43.0 62.6 4.37 6.89 0.05 0.04
1000 1000 --.010
-.004
+ 0.1 -0.1 --0.1
--2.9 --.014 --.019 --.019 -.017 41.3 62.5 4.53 6.98 0.08 0.08
1500 -.016
+ 0.2 --o-i
--.016 --.035
ee
--... --
1500 --.016
0.0 -0.1
--.016 --.039 39.9 4.15 0.18
'
loti 400 hour* test condition* were accelerated up to 1,500 p.i.i., 1,800 r.p.m.
DSW 321907
5
STLCOPCB4073557
DSW 321908
STLCOPCB4073558
Photographic record of results of pump test referred to on page 4 and table, page 5.
Parts shown, were examined and photographed at 200, 400, 526.8 and 800 hours. Parts of pump tested with Pydraul F-9 are illustrated in color panel below. Wear on control pump parts is illustrated at top.
526.8 HRS,
800 HRS.
STLCOPCB4073559
NON CORROSIVE
CHE M I C A L L Y
STABLE
N O N R E AC T I V E
Pydraul F-9 is inert to common metals of construction, and is so chemically stable that it does not
break down under thermal or mechanical stress into degradation products which could attack metal
surfaces. Pydraul F-9 can be operated continuously without chemical breakdown at temperatures up to 300F.
The following tests were run according to procedures for determining corrosion and oxidation stability as
specified by the Army-Navy Aeronautical Specification, Oil; Hydraulic Petroleum-Based. Spec.
AN-W-0-366b, Amend. 2, Section E 4e.
CORROSION AND OXIDATION STABILITY
Viscosity at 130F.
Neutralization Number
Fluid Evaporation Fluid Separation Effect on Metals
Metal Copper Iron Aluminum Magnesium
-- Initial -- Final -- % Change -- Initial -- Final
'-
Wt. Change (mg./cm.1) --0.16 + 0.01 + 0.02 + 0.02
23.6 Centistokes 24.1 Centistokes
2.12 0.05 0.07 3.0% None
Vicual Examination Slight Darkening Nil Nil Nil
SHELL EOUR BALL WEAR TESTS -------(1 hour at 167F. and 600 r.p.m.)
Metolt
Lead (kg.)
Steel on Steel Steel on Steel Steel on Bronze Steel on Bronze
1 40
1 40
Scar Diameter
0.20 mm. 0.71 mm. 0.50 mm. 1.32 mm.
DSW 321910
STLCOPCB4073560
r PYDRAUL
i
\
(
i i .. EXCELLENT PUMPABILITY
Pydraul F-9 is highly mobile, even at the lowest temperatures normally encountered in machine operation. This property insures less wear on pumps which are subject to infrequent operation or intermittent cold starts. Pydraul F-9's viscosity characteristics are almost identical with those of a medium grade petroleum-base hydraulic fluid. The following types of equipment have proved in actual use that Pydraul F-9 gives excellent operating characteristics in addition to the greater safety from fire:
DIE CASTING MACHINES HYDRAULIC RIVETING MACHINES AND PUNCHES HYORAULIC PRESSES HYDRAULIC OVEN DOOR ACTUATORS HYDRAULIC RAMS
ii
i 3
i
L
I i
DSW 321911 STLCOPCB4073561
PACKING AND GASKET MATERIALS
FOR USE WITH PYDRAUL F-9
With most standard packings and gaskets, ordinary fluids can simply be drained out, the
system cleaned as thoroughly as is practical, and filled with Pydraul F-9. Experience has shown that
although Pydraul F-9 may cause swelling in some types of gaskets and packings, unless the machine is
dismantled such swelling is not objectionable. Because of this swelling action it is impossible to reinstall standard packings removed from a Pydraul F-9 operated system. It is good practice to replace rather than reuse seals and packings and it is recommended that
resistant materials be installed at this time. Pydraul F-9 has a solvent action on certain paints. Suitable packing and gasket materials and surface
coatings are readily available. The following materials have been thoroughly tested; similar
materials of other suppliers, although not listed specifically, should be equally suitable:
10 DSW 321912
STLCOPCB4073562
PYDRAUL
SUPPLIER
Thiokol Corp., 780 North Clinton Avenue, fronton. New Jertey
Linear Inc., State Read and Levlck Street, Philadelphia 35, Penmylvanla
Plastic & Rubber Prods# Co., 2100 Hyde Park Blvd., lot Angelet 47, California
The S. To Goodrich Coe, Akron, Ohio
Dow Corning Corp., 1514 South Hope Street, Lot Angelet 15, Calif.
1,1. du Pont de Nemours A Co. Inc., Wilmington 98, Delaware
MATERIAL
Thiokol #FA Thiokol #FA
Linear PR70 Linear PR70 Linear PS85 Linear PS85 Linear ZB70 (silicone base) ("O" rings only)
TC-315-70
TIME OF IMMERSION
3 days 7 days
TEMP.
160F. 160F.
% SWELL
24.0 26.8
7 days 7 days 7 days 7 days 7 days
Rm. temp. 158F.
Rm. temp. 158F. 158F.
70 hrs.
158F.
4 20
4 20
4
10.5
147-GH-7 (butyl hose)
Silastic 250 Silastic 250 Silastic 250 Silastic 250 Silastic 181 Silastic 181 Silastic 7-170 ' Silastic 7-170
7 days
3 days 7 days 1 day 4 days 1 day 4 days 1 day 4 days
160F.
160F. 160F. 392F. 392F. 392F. 392F. 392F. 392F.
21.5
8.15 9.96 16.8 8.2 6.7 4.7 8.0 7.5
' Nylon (for protective coatings over wire and painted surfaces) and Teflon (for back up rings) are suitable for use with Pydraul F-9.
0S*19A3 11
STLCOPCB4073563
READILY AVAILABLE
Pydraul F-9 is manufactured from raw materials that are in dependable supply. It is shipped under contract which protects the user from changes in quality, reduced quantity or shipping delays.
Pydraul F-9 is manufactured under strict quality control and is uniform in quality and appearance from shipment to shipment.
j
<4
12
For further information on Pydraul F-9, simply write or call Monsanto. A sample suitable for testing will be sent on request..
MONSANTO CHEMICAL COMPANY
Organic Chemico/f Division
00 N r t fc 12th lvd.
ST. LOUIS 1, MltSOUR
Birmingham Boston Charlotte, N. C. Chicago Cincinnati Cleveland Detroit Houston Los Angeles New York Philadelphia Portland, Ore. San Francisco Seattle Twin Cities Monsanto Conoda ltd.i Montreal,. Toronto, Vancouver Monsanto Chemicals (Australia) Ltd.i Melbourne Monsanto Chemicals Ltd.i London
DSW 321914
Print.d In U.S.A, 2180--03000-- 115 **3
STLCOPCB4073564
Monsanto SERVING INDUSTRY
WHICH SERVES MANKIND
DSW 321915
STLCOPCB4073565