Document 18yL3NBoqbNJ4eNYBkxRQjrj

ABERDEEN CHEMICAL PLANT ROUTINE CHEMICAL DOSIMETRY SUMMARY MONTH OF: January. 1982 DATE OF REPORT: February 11, 1982 c: JF , CRM, PEM, PJK, RDJ, WFH, SJV, RAF, RAM, T. G. Grumbles - Houston, L. A. Legendre - Pohear City ALL SAMPLE RESULTS: Chemical VCM Lead Antimony Total Particulates < PEL No * % 79 87 12 92 # 13 100 6 100 > PEL OVEREXPOSURES No. % 12 .13 18 00 00 OVEREXPOSURES: Job Class Color Weigh Compounder Reactor Operator Dryer Utility Mechanical Engineer Reactor Operator Maintenance Helper Vinyl Shift Supervisor Vinyl Shift Supervisor Chief Operator Reactor Operator General Mechanic General Mechanic General Mechanic Exposure 57.3* Micrograms Lead/M 1.1 ppm. VCM 1.2 PPin, VCM 1.3 ppm. VCM 1.3 ppm. VCM 1.8 ppm. VCM 1.8 ppm. VCM 1.9 ppm. VCM 2.3 ppm. VCM 2.3 ppm. VCM 2.4 PPm, VCM 5.2 ppm. VCM * 9.1*ppm,VCM * Source -Employee did normal job of color weigh up. Specific cause not determined. -Employee worked in area where coarse batches were being dumped. -Specific cause not determined. -Employee worked near dump tank during "delumper" test run. -Specific cause not determined. -Employee helped install new manway on D-700 Rx. -Specific cause not determined. -Specific cause not determined. -Specific cause not determined. -Specific cause not determined. -Employee tightened S. end of new unit recovery condenser(leaking) -Employee repaired high pressure water pump in V--11. -Employee repaired vacuum pump in V-ll. VAB.0001073500 %< PEL 100 VCM 100 Lead 0 100 Antimony 0 100 Total Pa rticulates 0 ABERDEEN CHEMICAL PLANT CHEMICAL DOSIMETRY TRENDS MPMPMMVPMi * VAB.0001073501