Document 15qxG6j5qgnn26JZYKGzERavE

AEI SCIENTIFIC APPARATUS INC. 647 SO KINGERY HIGHWAY - ROUTE 83 ELMrtURST. ILLINOIS 60126 V.V April 5, 1971 Erwin Eichen, Ph.D. Ford Research Laboratories Ford Motor Company Dearborn, Michigan Dear Dr. Eichen: Attached is a detailed report on asbestos analysis showing quantitative information. You will note that it is easy to decide which form of asbestos is present. 1 hope this will be of further value in evaluating EMMA-4. Best regards. Thomas Leach Representative TL/bl . Enclosures C ..................... 8000 044$ yj.0.......................................... ' PRODUCED BY FORD SCF-FORD-0710 analytical electron microscope application medical Electron micrographs and spectrometer plots showing presence of AMOSITE asbestos fibres in human lung tissue asbestosis in human lung ooofr Transmission electron micrograph An example of the application of the EMMA-4 tech- mque in medical research concerns the study of asbestos fibres extracted from human lungs Recent work in several laboratories has demonstrated the danger of inhaling such fibres and has shown that the ill-effects may not manifest themselves until many years after the inhalation The problem therefore arises of establishing to which group of the asbestos materials parncu'ar extracted fibres belong, in order to be able to relate this to the lung damage and also to trace the source. The figure illustrates the type of results obtained with the new instrument. The transmission image shows the fibres on this sample, a lung tissue section, to be down to about 1000A in thickness - often with "trains" of growth along them (top centre of the image) - and with a wealth o( both surface and internal detail which can only be resolved in a transmission electron micrograph The direct spectrometer output in the form of peaks plotted for iron and silicon K radiations from the fibre A is also shown in the figure. Simply by measuring fibre composition in the form of element ratios from such peaks it is possible to identify these particular fibres as AMOSITE asbestos Further confirmation can be obtained by electron diffrac tion. if required The essence of the problem posed by this particular specimen, i e the correlation of chemical, morphological and crystallographical mformahor on a sut noon scs'e is. of course, very general and i: is for t . s 'ev.sen tnat re scope for sopl.c soon cf the new instrument is likely to be verv-vdo'p: ad 5)'Ho PRODUCED BY FOR n Silicon 10 K 6 Iron Characteristic peaks plotted for silicon and iron from fibre A. counts per second wavelength 1 The new Analytical Electron Microscope. EMMA-4, has facilities for loading 6 specimens in one holder, and accurate selected area diffraction combined with high-resolution electron microscopy and high-sensitivity microanalysis For further information see Publication 2040-10 describing the unique performance of EMMA-4. Acknowledgement The work described was earned out at Tube Investments ftesearch Laboratories on the combined electron microscope!microanalyser AEl Scientific Apparatus Ltd P.O. Box 1 Harlow Essex Eno'and Tc, ' PQ 80 00 0447 PRODUCED BY FORD e v Anthonhyllite (single fibred SiD* . '.O3v50 Pe Si A1 Ca % Na y peak 1270 5009 4 57 144 1 background 14 94 2 5 2 P-b 1256 >000 - 55 141 - Continuum * 66 / 71 70 ' /* X 79 y 75 72 \ y x' c * I Peak no. of x-ray counts collected in 10 seconds with the spectrometers set at the charaoteri&tic (peak) wavelength position for that element. background no. of x-ray counts in 10 seconds at a wavelength position away from the peak. . P-b true no. of x-ray counts for that element concentration! but this has to be corrected for spectrometer efficiency etc. Continuum - the white radiation collected in the non dispersive detector to . monitor the mass thickness of the specimen. * The results show the presence of Pe, Si, Ca and Mg but A1 and Na were not detected. C *ono ' UM PRODUCED BY FORD Croeidolite 5V- z^o . 6 , q ft P b, P-b Continuum Pe Si A1 9813 70 9745 116* / 4823 25 4806 246 / Ca Mg Ka 55 29 2 5 5- 52 16 1 216 113 164 // 7 Amoslte . ho. S`0*. P b. P-b Continuum Pe Si n 14750 2888 60 20 14690 2866 136 240 // 9 4 5 196 ? Ca % 69 38 42 65 . 36 179 162 /y Ha 2 - 2 203 ? Variations in the continuum count are due to the single fibre moving slightly . tender the probe for different readings. ' .Where small quantities of elements are suspected, e.g. Ha, x-rays can be counted for longer periods of time, e.g. 100 seconds or more, to obtain more quantitative results. '. 8000 84R9 PRODUCED BY FORD Chrysotilo 3^0. ?S;0i.2^0 KgFe Si A1 Ca Ka p 279 1150 11 27 72 1 b . 9 52 3 3 1 P-b 270 1145 9 24 69 a* Continuum 53 56 72 62 64 . 75? y yy y y ? ( I f 1 < The results show a variation in relative element concentration between different fibre, and could be corrected against solid standards to obtain quantitative results. This technique is therefore valuable in determining the different types of asbestos found in lung diseases. V l *000 0450 /` y PRODUCED RY mpn