Document 15qxG6j5qgnn26JZYKGzERavE
AEI SCIENTIFIC APPARATUS INC. 647 SO KINGERY HIGHWAY - ROUTE 83 ELMrtURST. ILLINOIS 60126
V.V
April 5, 1971
Erwin Eichen, Ph.D.
Ford Research Laboratories Ford Motor Company Dearborn, Michigan Dear Dr. Eichen: Attached is a detailed report on asbestos analysis showing quantitative information. You will note that it is easy to decide which form of asbestos is present.
1 hope this will be of further value in evaluating EMMA-4. Best regards.
Thomas Leach Representative TL/bl . Enclosures
C
.....................
8000 044$
yj.0..........................................
' PRODUCED BY FORD
SCF-FORD-0710
analytical electron microscope application medical
Electron micrographs and spectrometer plots
showing presence of AMOSITE asbestos fibres in human lung tissue
asbestosis in human lung
ooofr
Transmission electron micrograph
An example of the application of the EMMA-4 tech-
mque in medical research concerns the study of asbestos fibres extracted from human lungs Recent work in
several laboratories has demonstrated the danger of inhaling such fibres and has shown that the ill-effects may not manifest themselves until many years after the
inhalation The problem therefore arises of establishing to which group of the asbestos materials parncu'ar
extracted fibres belong, in order to be able to relate this to the lung damage and also to trace the source. The figure illustrates the type of results obtained with the new
instrument. The transmission image shows the fibres on this sample, a lung tissue section, to be down to about
1000A in thickness - often with "trains" of growth along
them (top centre of the image) - and with a wealth o( both surface and internal detail which can only be
resolved in a transmission electron micrograph The direct spectrometer output in the form of peaks plotted for iron and silicon K radiations from the fibre A is also shown in
the figure. Simply by measuring fibre composition in the form of element ratios from such peaks it is possible to
identify these particular fibres as AMOSITE asbestos Further confirmation can be obtained by electron diffrac
tion. if required
The essence of the problem posed by this particular specimen, i e the correlation of chemical, morphological
and crystallographical mformahor on a sut noon scs'e
is. of course, very general and i: is for t . s 'ev.sen tnat re scope for sopl.c soon cf the new instrument is likely to be
verv-vdo'p: ad
5)'Ho
PRODUCED BY FOR n
Silicon 10
K
6
Iron
Characteristic peaks plotted for silicon and iron from fibre A.
counts
per second
wavelength
1
The new Analytical Electron Microscope. EMMA-4, has facilities for loading 6 specimens in one holder, and accurate selected area diffraction combined with high-resolution electron microscopy and high-sensitivity microanalysis
For further information see Publication 2040-10 describing the unique performance of EMMA-4.
Acknowledgement The work described was earned out at Tube Investments ftesearch Laboratories on the combined electron microscope!microanalyser
AEl Scientific Apparatus Ltd P.O. Box 1 Harlow Essex Eno'and Tc, '
PQ 80 00 0447
PRODUCED BY FORD
e v
Anthonhyllite (single fibred
SiD* .
'.O3v50
Pe Si A1 Ca % Na
y
peak
1270 5009 4 57 144 1
background
14
94
2
5
2
P-b
1256
>000
-
55
141
-
Continuum
*
66 /
71 70 ' /* X
79 y
75 72 \
y x'
c
* I
Peak no. of x-ray counts collected in 10 seconds with the spectrometers set at the charaoteri&tic (peak) wavelength position for that element.
background no. of x-ray counts in 10 seconds at a wavelength position away
from the peak.
.
P-b true no. of x-ray counts for that element concentration! but this has to be corrected for spectrometer efficiency etc.
Continuum - the white radiation collected in the non dispersive detector to
.
monitor the mass thickness of the specimen.
* The results show the presence of Pe, Si, Ca and Mg but A1 and Na were not detected.
C
*ono
' UM
PRODUCED BY FORD
Croeidolite
5V- z^o . 6
,
q ft
P b, P-b Continuum
Pe Si A1
9813 70
9745 116* /
4823 25
4806 246
/
Ca Mg Ka
55 29
2
5 5-
52 16
1
216 113 164
//
7
Amoslte
. ho. S`0*.
P b. P-b Continuum
Pe Si n
14750 2888 60 20
14690 2866 136 240
//
9 4
5
196 ?
Ca %
69 38 42
65 . 36 179 162
/y
Ha
2 -
2 203
?
Variations in the continuum count are due to the single fibre moving slightly
. tender the probe for different readings.
'
.Where small quantities of elements are suspected, e.g. Ha, x-rays can be
counted for longer periods of time, e.g. 100 seconds or more, to obtain more
quantitative results.
'.
8000 84R9
PRODUCED BY FORD
Chrysotilo
3^0. ?S;0i.2^0
KgFe Si A1 Ca
Ka
p 279 1150 11 27 72
1
b . 9 52 3 3 1
P-b 270 1145 9 24 69 a*
Continuum 53 56 72 62 64 . 75?
y yy y y ?
(
I f
1 <
The results show a variation in relative element concentration between different fibre, and could be corrected against solid standards to obtain quantitative results. This technique is therefore valuable in determining the different types of asbestos found in lung diseases.
V
l
*000 0450
/` y
PRODUCED RY mpn