Document 15gVRDOMdgYvrr9OzjqJ7L5Qa

FILE NAME Kelly Moore KM DATE 1976 Mar 18 DOC KM028 DOCUMENT DESCRIPTION Letter from Liberty Mutual to KM with Attached Asbestos Survey Report 2755 S. Locust Street Suite 215 Denver Colorado 80222 Tel 303 758-2282 March 18 1976 Mr. Luis Garcia Plant Superintendent Kally - Moore Paint Company 3600 East 45th Avenue Denver CO 80216 RE Asbestos Survey Report Dear Mr. Garcia asbestos survey report conducted January 15 1976 is your copy of the that this department will probably shut down Enclosed Per our conversation you indicated Should a change be made in this decision all operations effective April 1 1976. and should receive immediate attention the four recommendations remain applicable Sincerely yours Wesley M. Goodson Sr. Loss Prevention Represents HC William ce E. Moora President Ted Gessner Secretary - Production Robert Miller Vice President KM 01127 PLAINTIFF'S EXHIBIT ----"--, LIBERTY MUTUAL INSURANCE COMPANY COMPANY LIBERTY LIFE ASSURANCEASSURANCE COMPANY OF BOSTO LIBERTY MUTUAL FIRE INSURANCE HOME HOME OFFICES BOSTON EQUAL OPPORTUNITY EMPLOYERS ASBESTOS SURVEY MOORE INC DENVER COLORADO MAR 22 22 1976 Date of Survey January 15 1976 Date of Report March 10 1976 Report Prepared by Bill Lutts Asst Southwest Div Industrial Hygienist KM BB 5641 ae MOORE INC DENVER COLORADO DRY WALL MIXING AREA Date of Survey January 15 1976 Date of Report March 10 1976 Material Sampled Airborne Asbestos Fibers * Analysis Method Contrast Micorscope Recommended Engineering Control Limit 2 fibers greater than 5 microns in - length Location 1 Middle of workroom Breathing zone height Pump fixed on center support column 40 minutes sampling during batch mix . 2 Second sample under same conditions as # above 3. Personal sample 40 minutes sampling time during mixing cycle operator's breathing zone 4 Same conditions as # above ; Fibers 5 3 1 2 -6- KM BB 5646 ASBESTOS SURVEY KELLY INC DENVER COLORADO INTRODUCTION made A survey was for airborne asbestos fibers in the dry wall products mixing area at Moore Inc. , Denver Colorado on January 15 1976. The purpose of the was to measure the presence and quantity of airborne asbestos fibers greater survey than five microns in length The shorter fibers are not considereads an asbestos hazard but rather as a category of free silica exposure The recommended engineering control limit for asbestos fibers at presenits 2 fibers per milliliter per cubic centimeter of workroom air for a normal work day and work week exposure A total of four samples was taken with two pumps One pump was mounted on the one man working in the dry wall area and the other pump was mounted on the center column of the room and measured the overall asbestos content of the air away from the ribbon mixers The samples were taken open face at a rate of 2 liters per minute for 40 minutes and a blank submitted with the exposed filters as a control CONCLUSIONS The two samples taken on the mixing operator indicates that his exposure is less than or equal to the recommended engineering control limit during a mixing cycle ventilation This result is not surprising since the system on the ribbon mixers where the bags are opened and emptied is doing an excellent job In light of the relatively low exposure of the operator the general room air results are surprisingly high KM BB 5642 An analysis of the sample taken in the center of the room at breathing zone height indicates greater than the that the number of asbestos fibers in recommended engineering control limit the workroom air is of 2 fibers per milliliter milliliter Readings of 5 fibers per and three fibers per milliliter were obtained on each of the two 40 minute sampling runs Measurements of the general room air flow were also made during the sample period and indicated that air was flowing in area from the paint mixing and out through the door which leads to the warehouse storage for the area Given the operator's low exposure the only reasonable explanation in results is that the dust collector system beside the door difference which leads to the main paint mixing area is leaking or emitting fibers in some way and the general room air flow is then carrying them through the very region where we took the general room air sample The low results obtained on the operator who is the only man exposed in the room indicates that the local exhaust ventilation system is performing properly at the source of contaminant that our results give a true picture of the situation the Therefore assuming collector end of the exhaust ventilation system should be carefully checked for places where asbestos fibers might be escaping into the general room air RECOMMENDATIONS| 76-1 A collection barrel is located beneath the dumping chute of the main dust collector bin There is several inches of clearance between barrel the It bottom opening of this bin and the top of would be advisable to connect the bin and the the collection barrel with a plastic sleeve which would prevent the release of asbestos fibers when into the room air the collection bin is dumped into the collection barrel In addition this would reduce the possibility that a leak in the bottom bin opening or the residual fibers in the barrel itself is a source of room contamination KM BB 5643 76-2 Care should be taken to make sure that asbestos bags are not included in the compactor presently in use One bag had inadvertently been placed in the compactor at the time of our visit The operator demonstrated the normal disposal procedures and indicated that this particular bag had been placed there in Given the proximity of the compactor to the general room sample it is possible error by another employee the center post where we took that this single asbestos bag contributed significantly to the total fiber levels detected 76-3 The duct work of the dust collection system should be carefully checked to make sure that there are no leaks emitting asbestos fibers and dust into the work room air A visual inspection at the time of our visit did not reveal any leaks But this is one possible explanation of the high detected levels which should be investigated 76-4 in this area should Operators protective equipment until such time continue to wear their personal as the effectiveness of the respirators presently engineering controls are fully verified The in use approved for asbestos fibers and pneumoconiosis producing are dusts THE SURVEY The four samples sampling pumps taken were collected in A flow rate of 2 liters the per standard manner using two personal minute was used A sampling period of 40 minutes per sample was used The samples were taken with the cassettes open and pointed downward to prevent unwanted trash from settling on them -4- KM BB 5644 af on of One pump was mounted directly the operator of the ribbon mixer and a total two samples was taken with this pump The other personal sampling pump was mounted in the center of the room at breathing zone height and two samples were takeonn this pump also More than two samples per pump might have been taken except that the mixing operations for that days workload had come to an end with the conclusion of the second set of samples Industrial The collected samples were then submitted to our Hygiene Laboratory at Hopkinton Massachusetts They were analyzed there by means of a contrast microscope A visual counting method was used to determine the number of fibers greater than 5 microns in length collected during the sampling period This total sample volume collected and the total number of fibers present allowed the determination of fibers per milliliter to be determined A recommended engineering control limit of 2 fibers per milliliter is suggested in this report Bill Lutts Asst Southwest Division Industrial Hygienist KM BB 5645 KM BB 5647 KELLY MOORE San Carlos California ASBESTOS SURVEY On June 30 1975 a visit was made to this plant to evaluacotnetrotlhse aasndbestos following installation of additional engineering Mike exposure of the amount of asbeus set d ao los ng some of the lines reduction Mutual's Senior Loss Prevention Representative accompanied Love Liberty the writer CONCLUSIONS of 1. All employees working in the Paco Division this plant not considered exposed excessive asbestos in air are concentrations This is based on the current health based on the standard However if our judgment was health standard effective July 1 1976 the dry texture filler would be considered exposed to an excessive amount of asbestos air concentrations 2 The exhaust ventilation on the dry texture bagging machine is ineffective RECOMMENDATIONS so 1 The local exhaust ventilation on thethdarty dutsetxtucraen bbeagegfifnegc- machine be redesigned tively captured and removed of the dry texture bagging machine should be 2 The operatwoirth coveralls as much of this dust is infiltrat- for provided ing his street clothes This increases his chance ~ members of taking asbestos fibers home and exposting other his family texture mixer dry texture mixer and ready 3 The ceiling dust masks that have been mixer should wear the approptrhieayteare dumping bags of asbestos provided for them wheneverventilation has been provided at Even though local exhaust minute the these dumping stations 150 linear feet per and dust actual dumping of asbestos does create turbulence which oftens billows into the operator's face before being exhausted KM BB 5648 DISCUSSION as This survey is the third that has been completed cfoonrtraoslbsestthoast we Ir te is a evaluation to measure some of the engineering exhaust ventilation designed around the ceiling instituted such the reduction of asbestos primarily along the ceiling texture bager and which has dropped from approximately 150 pounds of asbestos texture line per batch to 15 pounds of asbestos per batch Survey Method Air samples were collected on metmhbermanveia fpieltresrosnal0.s8ampl- micron porosity with air being pulled through two liters per minute Air samples were ing pumps at approximately zone filter cassettes attached collected in both the employees breathing to operator's shirt lapel and pump attached to their belt and air samples air collected in various areas of the plant to determine background were concentrations All samples were analyzed at our Hopkinton Massachusetts method laboratory via the phase contrast microscope - As are probably now well aware asbestos is a health Toxicity you a lung disease called asbestosis hazard which when inhaled may cause In addition it may This takes 10 to 20 years to develop after exposurereferred to as meso- also cause cancer of the chest or abdominal lining thelioma This may be fatal within one year after the first symptom Standards ~ The current health standard for exposure to airborne Health asbestos fibers is five fibers per milliliter of air This is an eight milliliter of hour time weighted value which will drop to two fibers per 1976. Health standards are guidelines below which most air July 1 would not be expected to experience any biological discomfort weoxrkiesrsting conditions or individual susceptibility may be exceptions to this - Our data indicates that most of Paco Textures Manufacturing Department working within the Paco texture area are exposed to one the employees The exception to this is the dry fiber per milliliter of air or less texture filler operator Our data indicated that all the air samples milliliter of air taken in his breathing zone indicated three fibers per This similar to those taken back inMarch 1973 These readings are very asbestos is acceptable only until July 1 current air concentration of to 1976 however from a standpoint of health and exposing an employee unnecessary asbestos fibers in the air this level is unacceptable high this level is so is the exhaust ventilation for the The reason that is ineffective The exhaust ventilation duct ' dry texture bagging machine The duct is so is directly behind the bagging slot and machine supports of dis- back that it's completely ineffective just from a standpoint far of the parts to the machine It tance let alone being obstructed by some be designed and is suggested that this local exhaust ventilation system KM BB 5649 DATA RESULTS OF Asbestos in air DATE OF SURVEY June 30 1975 SURVEY METHOD Membrane filter METHOD OF ANALYSIS Phase contrast microscope HEALTH STANDARD , Eight Hour Time Weighted Weighted . Fibers per Milliliter of Air ; S Current - Effective July 1 1976 2 -5- KM SAMPLE # 1 2 ' 4 5 6 7 8 ; LOCATION Operator's Breathing Zone OBZ ceiling texture mixer OBZ ceiling texture filler ; OBZ dry texture mixer OBZ dry texture filler OBZ ceiling texture mixer OBZ ceiling texture filler OBZ dry texture mixer OBZ dry texture filler TIME OF DAY 8:00 8:00 8:15 8:15 9:30 9:30 9:30 9:30 SAMPLING TIME MINUTES 53.5 44.5 52.0 50.5 45.0 47.0 50.5 50.5 AIR VOLUME LITERS 107 89 104 101 90 94 101 101 RESULTS ASBESTOS FIBERS 1 * 0.7 3 2 * 0.9 3 BB 5650