Document 15Y71kDQzXMVy6z7ZLgp48rNa
490
CHAPTER 19
1957 Guide-
Table 8. Capacity and Sizing Table--First Story
For Warm Air and Return Air Stack, Branch, and Registers
Equiv. Length or
Fittings
and Registers
Horizontal Length Furnace
to Register -
Insulated Ducts* Attic
Ducts
First Story
Room Heat Loss--btuh
CoL a
Col. b Col. c Col. d Col. e
Col. f
Col. g Coi. h Col. i
CoL j
Up to 70 Eq. Ft.
71 to 100 Eq. Ft.
101 to 130 * Eq. Ft.
131 to 165 Eq. Ft.
166 to 200 Eq. Ft.
Up to 7 8-12
13-17 18-25
Up to 5 6-0
10-13
14-18
26-35 36-45 46-55
Up to 7 8-12 13-17
.18-25
19-25 26-35 36-45 46-55
Up to 5 6-9
10-13 14-18
26-35 36-45 46-65
Up to 7 8-12 13-17 18-25
19-25 26-35 36-45 46-55
Up to 5 6-9
10-13 14--18
26-35 36-45 46-65
Up to 7 8-12 13-17 18-25
19-25 26-35 36-45 46-55
Up to 5 6-9
10-13 14-18
26-35 36-45 46-55
Up to 7 8-12 13-17 18-25.
19-25 26-35 36-45 46-55
Up to 5 6-9
10-13 14-18
26-35 36-45
46-65
19-25
26-35 36-45
46-65
7,200 6,700 6,100 5,600
4,800 4,100 3,500 3,000
. 5,500 5,100 4,800 4,500
3,900 3,400 3.000 2,600
4,600 4,300 4,100 3,800
3,300 3,000 2,700 2,300
4,100 3,800 3,600 3,400
2,900 .2,600 2,300 2,000
3,800 3,500 3,300 3,100
2,700 2,400 2,100 1,700
12,500 11,700 -
10,800 9,900
16,000 15,000 14,000 13,000
8,500 7.400 6,400 5,500
9,900 9,200 8,600 8,100
11,000 9,900 8,700 7,700
13,100 12,300 11,600 ' 10,900
7,100 6.200 5,400 4,600
8,500 7,900 7,400 6,900
9,700 8,500 7,500 6,500
11,300 10,600 10,000 9,400
6,100 5,300 4,700 4,000
7,300 6,900 6,400 6,000
8,400 7,400 6,500 6,400
9,800 9,100 8.600 8.100
5,300 .4,700 4,200 3,600
6,500 6,100 5,700 5,400
7,200 6,400 5,600 4,700
8,800 8,200 7,700 7,200
4,800
4,300 3,800
3,000
6.400 5,700
5,000 3,900
19,100 18,000 17,000 16,000
14,200 . 12,500 11,000 9,600
16,300 15,400 14.500 13,700
12,200 10,800 9,500 8,300
14,300 13,500 12,700 11,900
10,500 9,300 8,300 7,000
12,300 11,700 11,000 10,300
9,100 8,100 7,100 6,000
11,000 10,500 9,900 9,300
8,300 7,300 6,400 5.100
25,000 23,400 21,600 19,800
17,000 14,800 12,800 11,000
19,800 18,400 17,200 16,200
14,200 12,400 10,800 9,200
17,000 15,800 14,800 13,800
12,200 10,600 9,400 8,000
14,600 13,800 12,800 12,000
10,600 9,600 8.400 7,200
13,000 12,200 11,400 10,800
9,600 8,600 7,600 6,000
32,000 30,000 28,000 26,000
22,600 19,800 17,400 15,400
26,200 24,600 .23,200 21,800
19,400 17,000 15,000 13,000
22,600 21,200 20,000 18,800
16,800 14,800 13,000 10,800
19,600 18,200 17,200 16,200
14,400 12,800 11,200 9,400
17,600 16,400 15,400 14,400
12,800 11,400 10,000 7,800
80.000 75,000 70.0&IK 65.000
56,500 49,500 43,500 38,500
65,500 61,500 58,000 54,500
48,500 42,500 37,500 33,500
56,200 52,600 50,200 47,300
42,000 37,000 32,400 27,000
49,200 45,800 41,900 40,300
36,000 31,800 28.100 23,500
44,100 51.500 38,800 36,000
32,000 28,200 24,700 19.500
Combination Number
Stacks^ No. Eire
Rectangular Branch Size Round Branch Size (Diam)
Number of Joist Spaces and Minimum Depth-Return Air
41
1 10x3%
3x8 5
1 at 3
42
j
10x3%
4x8 6
1 at 3
43
1
12x3%
5x8 7
1 at 4
44
1
14x3%
6x8 8
1 at 5
45
2
10x3%
8x8 9
1 at 6 or 2 at 3
46
2
12x3%
10x8 10
1 at 7 or 2 at 4
47
--
_
15x8 12 1 at 9 or 3 at 5
Registers: Low Wall, High Wall Registers: Floor-Warm Air
10x6 8x10
10x6 8x10
12x6 9x12
14x6 9x12
(2)10x6 or
(1)24x6
10x12
(2)12x6 or
(1)30x6
12x14
--
____
--
Registers: Floor-Return Air Trunk Duct Increase. Inches
6x10 or 4x14
1
6x10 or 4x14
2
6x12 or 6x14
3
longer 6x14
4
6x30 5
_
6x30
8x30
___ -
7 12 ________
* Uninsulated ducta in heated spaces and insulated ducte in unheated spaces.
b Note: For return air a 14x3% in. stud space may be used instead of 10x3% in: stack. Where 12x3% Pj* or 14x3% in. stack is required, a 14x3% in. stud space may be used only when inside of stud space is smQO* and without protruding plaster keys. The number of joist spaces for combination 47 is based on 2x8 in. joists
One space may be used with 2x10 in. joists.
The limiting factor for a duct combination is the stack capacity.
Warm Air Heating Systems
491
Table 9. Capacity and Sizing Table--Second Story
For Warm Air and Return Air Stack, Branch, and Registers
Equiv. Length or
Fittings
and Registers
Horizontal Length Furnace
to Register
Insulated Ducts* Attic
Ducts
Second Story Room Heat Loss--stub
Col. a
Col. b Col. c. Col. d Col. e Col. f Col. g Col. h Col. i CoL j
Up to 70 Eq. Ft.
71 to 100 Eq. Ft.
101 to 130 Eq. Ft.
131 to 165 Eq. Ft.
166 to 200 Eq. Ft.
Up to 7 8-12 13-17 18-25
26-35 36-45 46-55
Up to 7 8-12 13-17 18-25
26-35 36-45 46-55
Up to 7 8-12 13-17 18-25
26-35 36-45 46-55
Up to 7 8-12 13-17 18-25
26-35 36-45 46-55
Up to 7 8-12 13-17 18-25
26-35 36-45 46-55
Up to 5 6-9
10-13 14-18
10-25 26-35 36-45 46-55
Up to 5 6-9
10-13 14-18
19-25 26-35 36-45 46-55
Up to 5 6-9
10-13 14-18
19-25 26-35 36-45 46-55
Up to 5 6-9
10-13 14-18
19-25 26-35 36-45 46-55
Up to 5 6-9
10-13 14-18
19-25 26-35 36-45 46-55
6,300 5,700 5,200 4.800
4.100 3,500 3.100 2.800
5.000 4,600 4.300 4.000
3,400 3.000 2,700 2.300
4,200 3,900 3,700 3,500
3.000 2,600 2,400 . 2.000
3.800 3,500 3,200 3,000
2,700 2,300 1,960 1.800
3.500 3,200 2.900 2,700
2.500 2,100 1.900 1.500
10,900 10,000 9,200 8,500
7,300 6,400 5,600 5,000
9,000 8,200 7,600 7,100
6,200 5,400 4,700 4,200
7.700 7.200 6.700 6.200
5,400 4.700 4,100 3,600
6,800 6.300 6,800 5,500
4,800 4,200 3,400 3.300
6,100 6,700 5,300 5,000
4.400 3,900 . 3.400 2,800
14.000 13,000' 12,100
11,400
17.000 15.900
14.900 13,900
10.000 8,800 7.800 6.800
11,900 11,000 10,300 9,600
12,400 11,100 9,900 9.000
14.800 13,900 13,000 12,200
8,400 7,500 6.700 6,000
10,400 9,700 9,000 8.400
10.800 9,600 8.500 7.500
13,000 12,100 11,300 10,600
7.400 6,500 5.800 4.800
6,100 8.400 ` 7,900 7.400
9.400 8,300 7.400 6,500
11,400 10,500 9.800 . 9,200
6.300 5,700 4,500 4.300
8,200 7,600 7.100 6,700
8,100 7.200 5.800 5,400
10,300 9.500 8,900 8,300
5,700 6.100
4.500
3.500
7,400 6.500 5,800
4,700
21,800 20,000 18,400 17.000
14.600 12,800 11,200 10.000
18,000 16.400 15.200 14.200
12.400 10,800 9.400 8.400
15.400 14.400 13.400 12.400
10,800 9,400 8,200 7.200
.13,600 12,600 11,600 .11,000
9.600 * 8,400
6,800 6.600
12,200 11,400 10,600 10,000
8.800 7.800 6.800 5.600
28,000 26.000 24,200 22,400
20,000 17.600 15.600 13.600
23,900 22,000 20,600 19,200
16,800 15.000 13,400 12.000
21,700 19,400 . 18,000 16,800
14,800 13,000 11,600 9,600
18,200 16,800 16,800 14,800
12,600 11,400 9,000 8,600
16.400 15.200 14.200 13.400
11.400 10.200 9.000 7.000
70.000 65.000 60,500 57.000
50.000 44.000 39.000 34.000
59.500 55.000 51.500 48.000
42.000 37.500 33.500 30.000
52,200 48,400 45.300 42.300
37.000 32,500 29.000 24.000
45.500 42,000 39,600 36.800
32.200 28.200 22.800 21.500
41.000 38,300 35.800 33,400
29.000 25.800 22.800 17,500
Combination Number Stacks^ No. _____ Size Ewtanmlar Branch Sixe "and Branch Size (Diam)
w? ol Joist Spaces and siimmum Depth-Return Air
Floor, Warm Air
Floor, Return Air
T`unk Duct increase, Inchea
41
.1 10x3%
3x8 5
1 at 3
10x6
42
1 10x3%
4x8 6
1 at 3
10x6
8x10
8x10
0x10 or 4x14
1
6x10 or 4x14
2
43 :1 12x3%
5x8 7
1 at 4
12x6
9x12
6x12 or 6x14 3
44 45
1 14x3%
2 10x3%
6x8 8x8 89
1 at 1 at 6 5 or 2 at 3
14x6 . (2)10x6
or (1)24x6
9x12 or
longer
10x12
6x14
6x30
48 2 12x3% 10x8 10 1 at 7 or 2 at 4 (2)12x6 or (1)30x6 12x14
6x30
47' __ 15x8
12 1 at 9 or 2 at 6
"
8x30
4 5 7 12
-------------- ) .inu heated spaces and insulated ducts in .u. n...h..e...a..trewd. spaces.
or Hxgul2 ^.r rturn air a 14x3% in. stud space may be used instead of 10x3% in. stack. Where 12x3% in.
and withln* 8*ac* is rQuired, a 14x3% in. stud space may be used only when inside of stud space is smooth
One protruding plaster keya. The number of joist spaces for combination 47 is based on 2x8 joists.
"V?
be used with 2xK) joists.
Siting factor for a duct combination is the stack capacity.