Document 15LNZ1vB8pYom9denBYpn3Yw5

JULY 1953) <\y CATALOG V6 -^s ^.3 M-800 B OIL E R For OIL or GAS Mi Wj i^AAr yo/Lt*' For High and Low Pressure Steam or Hot Water Heating O KEWANEE-ROSS CORPORATION Division of American Radiator & Sfondcrd Sonilary Corporation KEWANEE. ILLINOIS A .LA . FILE N O . 34 B 1 {JULY 1953) HIGH AND LOW PRESSURE STEAM And Hot Water Heating The Kewanee M-SOO Boiler is not only Scotch in name but decidedly Scotch in its extra ruggedness and extreme thriftiness! It is designed, engineered and built to achieve new "highs" in fuel economy and operates at full efficiency even when pushed to produce 509c more than its rated capacity. And back of this outstanding product is Kewanee's more than SO years experience in the engineering, and fabrica tion of steel boilers. A "plus value" that can't be con verted into terms of dollars and cents. %. - ^ ^ = REAL" BOILER ENGINEERED TO DO A BIG JOB Kewanee puts more into a boiler, so the owner gets more out of it . . . that's the simple way to explain why Kewanee Boilers stay on the job for many extra years, delivering a lifetime of dependable service with notable savings in fuel. There is more Engineering, more Material and more Experience built into every Kewanee Boiler and these are the elements which make them different and better M-SOO is a real Kewanee in every respect From the largest to the smallest size every M-800 is a big husks' unit surface which gives the water in the boiler a chance to pick up and use all the heat. The long travel of hot gases . . . through the furnace, then back through the fire tubes . . . holds them within the boiler until all usable heat is absorbed. More steam space and more sceam disengaging area permit steam to rise without turbulence so only dry quality steam gets into the mains. The corrugated furnace (a feature of HM-800 for high pressure) adds strength and extra heating surface at the hottest parts of the fire and makes this boiler a fast steamer There is more Furnace Volume providing plenty of space for complete combustion It has ample heating Like all Kewanee Boilers. M-800 meets or exceeds the requirements of the A.S.M.E. and S.B.I. Codes. p -- arxc-RcA* Corporation easy to clean and inspect smokebox, "d .e^reiw^p,,s for access "to1 rear'corobtistion rhamben NO. 1 WELD, X-RAYED AND STRESS RELIEVED is -p fr" ff of h'T10*' k" removing entire back. accessible water surfaces Manhole on top of the .^'!er /"^^^wate^ys. Fite tubes Elation of water and mote accessible water surfaces. blow ah>s|>lure|necessity- Possible ow h0ies due to gas pockets faulty fusion or other defer.. ' . are 5tcsed to destruction. ^ detected and test specimens Pressure B^erT are'hear^0TM a'temp Furnace' Kewanee High allowed to cool gradually. A , K ' f '200 F-. thfn thus thoroughly annealed and any LkedTnV'S,ded !0,ms are _ y locked up stresses relieved. Choose KEWANEE and You Get More .. Look Inside and See SHELL ihaped from heavy flange steel with heads and furnace of firebox quality. Greater strength insures longer life. MANHOLE 11" x 15" in all boilers and washout open* ings provide accessibility to waterside. STEAM SPACE . . . generous steom space for ample reserve of dry steam to take care of unusual and sud den demands. STEAM DISENGAGING AREAS ore long and wide so steam bubbles move up into the steam chamber with out turbulence. REAR COMBUSTION CHAMBER is heavily lined with refractory. Boilers for high pressure incorporate dry back design. Low pressure boilers designed with water back top. Sectionol rear cover plate with observation port and access opening to fusible plug. FIRE TUBES, 3" in diameter o* heavy gage steel, ex panded into holes with ends firmly rolled and beaded Long GAS TRAVEL, through the lengthy combustion chamber, then bock through the full length of the fire tubes, transfers all usable heat to the boiler water. H CORRUGATED FURNACE for extra strength and add ed heating surface next to the fire. Its generous size provides plenty of space for the burning fuel to mix with the air and burn completely. Low pressure boilers provided with plain circular furnace. RAPID CIRCULATION through the wide, unobstructed woterways sweeps steom bubbles up without commo tion. M-800 is a very fast steamer. K Sturdy steel SADDLE SUPPORTS require no speciol base construction. Steel skids shown in cut-awoy illus tration above, furnished at additional cost. Substantia! hinged FLUE DOORS, gasketed for per manent gos-tight fit, provide easy access to fire tubes for cleaning and inspection. kk Gas tight SMOKEBOX of heavy gage steel . . . welded in one piece to boiler shell. Rectangular smoke out let located at top. 6.2 SQUARE FEET OF HEATING SURFACE per Horsepower of Boiler Rating The M-800 Series, like every Kewanee boiler, has been designed on 8.2 square feet of hearing surface for each horsepower of its rated capacity, which is in strict accord ance with the time-tested and proven code established by the Steel Boiler Institute. This proper proportioning of primary and secondary heating surfaces to the volume of water in the boiler comes only as a result of many years of experience and continual testing to find out just what is right. Kewanee s 84 years of experience can't be matched! 39 to 304 HORSE f3 S12ES 1,313,000 to 10,2 minimum -H - 10 RATINGS, DIMENSIONS AND DATA (feet-inches) Boiler Number --High Pressure . --low Pressure . SSI Rating -- Horsepower. -- Steam Radiation . . -- Water Radiation . -- Btu p *r Hour...................... -- Steam per Hour --212F HM-878 LM-878 sq ft . sq ft 1000's ib 39 5470 8750 1313 1 350 HM-879 IM-879 44 6080 9720 1459 1500 HM-880 LM-880 52 7290 1 1660 1750 1800 HM-881 LM-881 61 8500 1 3600 2040 2.00 hm-bs: lm-bs: 74 1033C 1 652C 2479 256? SBI Net Rating --Steam................................ Water............................... -- Btu per Hour Certified Output Rating ... Firing Rate -- Oil gph*** . -- Gas Btu hr . Heating Surface (SBI min} Furnace Volume (SBI min) Net Furnace Volume sq ft sq ft 1 000's hp 1000's . sq ft cu ft cu ft 4500 7200 1080 59 16 2460 322 39.1 45.8 5000 8000 1200 66 18 2740 358 43.5 48.4 6000 9600 1440 78 22 3280 429 52.1 57.9 7000 11200 1680 92 26 3830 500 60.8 62.4 850C 1 360C 204C I' 31 465? 60e 73.8 79.8 Safety Valve Capacity -- over 15 !b swp -- 1 5 lb swd A -- Boiler Diameter B -- Boiler Length C -- Steam Supply Height D -- Smoke Outlet Height E--Water Column Height F -- Furnace O. Dia. at Front G --Furnace Height H -- Steam Supply . j -- Safety Valve K -- Feed Water, each side Return 15 lb swp, each side M -- Blow-off N -- Smoke Outlet -- Width O-- --length P -- Support -- length R-- --Width S-- --Height T-- --location U-- --Center to Center V -- Tube Reoiacement Space lb steam per hr lb steam per hr .. 2576 1610 4-6 11-8 6-6 6-4 5-1 2*3 '/: 3-0 3-0 3-6 6-7 4-4 4-0 0-1 1 2-5 3-1 1 Vt 1 -4 1-6 2-3 6-1 1 7-2 2864 1790 4-6 12-7 6-6 6-4 5-1 2-3 '/j 3-0 3-6 4-3 7-1 4-4 4-0 0-1 1 2-5 3-1 1 Vi 1 -4 1-6 2-3 7-10 8-1 _ 3432 2145 5-0 1 1-7 7-0 6-10 5-6 2-6'/j 3-1 '/, 3-1 4-3 6-6 4-4 4-0 1 -0 3-0 4-5'/! 1 -5 1-6 2-4 6-9 6-1 1 4000 2500 5-0 1 2-9 '/a 7-0 6-10 5-6 2-6 '/i1 3-1 Vi 3-7 4-4 7-1 4-4 4-0 1 -0 3-0 4 5 Vi 1 -5 1 -6 2-4 7-1 1 8-1 Vi 4864 304C 5-6 13-2 7-t 7-4 5-9 2 3-3 3-8 4-5 7-4 4.c 4-3 1 -1 3-4 5-i ] ; 1 -6 2-5 8-1 8-2 Steam Supply Size -- 15 lb swp*. --over 1 5 lb swp * * Blow-off Size. Return Size 15 lb swp, each side . . . Feed Water Size Outside Surfoce to Cover . . . sq ft 0-6 0-4 0-1 '/, 0-4 0-1 % 165 0-6 0-4 0-1 Vi 0-4 0-1 % 180 0-8 0-4 0-2 0-4 0-1 Vi 180 0-8 0-4 0-2 0-4 0-1 V* 200 0-3 0-0-2 0-4 0-: 23C Breeching Diameter -- One Boiler Stack -- Diameter ................................ -- Height Breeching Diometer -- Two Boilers. . . Stack -- Diameter.. ................. -- Height. . 1-9 1-7 40-0 2-3 2-1 45-0 1-10 1-8 40-0 2-4 2-2 45-0 1-1 1 1-9 35-0 2-6 2-4 40-0 2-0 1-10 40-0 2-7 2-5 45-0 2-2 2-C 40-3 2-1 : 2-8 4 5 -: Approx. Weight-- 15 lb swp -- 125 lb swp .... -- I 50 fb swp . Ib . Ib Ib 7000 7600 8200 7400 8000 8700 8200 10000 10400 8800 11100 I 1500 1 130C 13i o: 13 903 OWER FOR ttt&tf PRESSURE 0,000 BTU FOR &WPRESSURE -883 -883 87 I 50 440 916 -010 '000 000 400 13 3> .460 715 36 8 37.5 HM-884 LM-884 109 15180 24280 3643 3750 1 2500 20000 3000 164 46 6840 893 1 08.5 1 10.2 HM-885 lM -885 1 30 1 8220 29150 4373 4510 15000 24000 3600 195 54 8200 1072 1 30.2 141.1 HM-886 HM-8B7 LM-886 , LM-887 1 52 2 1 250 34000 5100 5260 174 24290 38860 5830 6010 17500 28000 4200 20000 32000 4800 228 64 9560 261 73 1 0920 1 250 1 51.8 1 53.7 1429 1 73.5 1 74.0 HM-888 LM-888 217 30360 48570 7286 7510 25000 40000 6000 326 91 13670 1766 21 6.9 217.0 HM-889 LM-889 261 36430 58280 8743 9010 30000 48000 7200 392 1 10 1 6400 2143 260.3 262.9 HM-890 LM-890 304 42500 68000 1 0200 10510 35000 56000 8400 456 127 19120 2500 303.6 308.8 720 575 5-6 M0 7 - 6 '/ 7-4 5-9'/, 2-9 Vi 3-3 4-2 5-0 8-2 4-9 4-3 1 -1 3-4 5 - '/: i -6 i -6 2-8 9-6 10 0-8 0-6 0-2 0-4 0-1 Zi 260 2-4 145-0 3-0 M0 5C-0 400 000 i CO 7144 4465 6-0 16-1 8-0 Vi 7-10 6-1 '/, 2-1 1 '/: 3-5 4-9 5.0 8-10 5.3 4-5 1-2 3-6 5.7/, 1-7 1 -6 2-9 10-6 1 0-9 0-8 0-6 0-2 0-4 0-1 Zi 305 2-6 2-4 50-0 3-4 3-1 55-0 U800 17500 1 8700 8576 5360 10000 6250 6-6 16-7 6-6 1 8-7 8-6 '/: 8-4 6-5'/, 3-2 Zi 3-6'/: 4-10 5-0 9-3 5-8 5-4 8-6 Vi 8-4 6-5 Zi 3-2 Vi 3-6 Zi 5-4 6-6 10-3 6-2 5-4 1-3 3-1 1 1-3 3-1 1 6-1 1-8 1-6 2-10 10-6 6-1 1 -8 1-6 3-4 12-0 10-8 1 2-8 0-8 0-6 0-2 0-4 0-1 '/j 340 0-8 0-6 0-2 Zi 0-4 0-1 Zi 380 2-7 2-5 50-0 2-9 2-7 55-0 3-5 3-2 55-0 3-8 3-5 60-0 1 7400 20800 22700 19200 21900 24900 1 1432 7145 14288 8930 17144 1071 5 20000 1 2500 7-0 17-9 7-6 18-1 1 8-0 20-0 8-6 20-1 9-0'/: 8-10 6-9'/: 9-7/2 9-4 7-3 1 0-4 '/: 1 0-1 7-lO'/i 10-10 Vj 10-7 8-4 3-6 3-8 5-5 5-6 9-10 6-3 5-6 3-8 '/: 3-9 '/: 5-5 6-6 10-6 6-5 5-6 4-1 4-2 '/: 5-6 7-0 1 1 -0 6-7 5-6 4-5 4-4 Yz 5-7 7-0 1 1-0 6-7 5-6 1 -4 1-4 1 -5 1 -6 4-7 5-4 5-7 6-1 6-6 '/: 1-10 1-6 3-5 11-0 7-0/1 1-10 1-6 3-5 1 2-0 7-6 2-0 1 -9 3-6 1 3-0 7-6 2-0 1-9 3-7 1 3-0 1 1 -7 12-7 1 3-6 1 3-5 0-8 0-6 0-2 /: 0-4 0-1 !/: 390 2-1 1 2-9 50-0 0-10 0-8 0-2 '/: '0-6 0-1 '/: 440 3-3 3-0 55-0 0-10 0-8 0-2 '/: 0-6 0-2 500 3-5 3-2 55-0 0-10 0*8 0-2 /: '0-6 0-2 530 3-7 3-4 55-0 3-1 1 3-8 55-0 4-2 3-11 60-0 4-6 4-2 60-0 4-8 4-4 60-0 22400 27100 28700 26600 32000 34500 31300 37200 40100 35000 41900 45100 J50 lb American Standard Drilling. 300 lb American Standord Drilling. Fuel burning rates based on 150,000 Btu oil. Low Pressure Boilers furnished with openings for Oil Heater and Temperature Control. High Pressure Boilers furnished with openings for Oil Heater and Injector. Overall Height is increased IV'2" when steel skids ore furnished SAFETY VALVES--Boilers over 15 lb swp--Number ond size vcnes with valve setting All boilers having 500 sq ft or less of heating surface furnished with one valve Boilers hoving ->ore than 500 sq ft of heating surface furnished with two or more valves Manufacturer reserves right to use seporate outlets or yokes as conditions require. Boilers 15 ib swp--One or more valves furnished depending on required capacity, regardless of boiler heating surface. STANDARD EQUIPMENT (15-125-150 Ib STEAM)--Steel saddle supports, refractory lined rear combustion chamber factory installed Flue cleaner and handle. Washout plug socket wrench for 15 Ib boilers only STANDARD TRIM (15-125-150 Ib STEAMJ-Safety volve(s) os required by A.SM.E. Code, steam gouge with syphon and cock, woter column, water gauge valves, glass, guards and three try cocks. Chain operated water gauge valves ond try cocks with boilers HM-884, lM-884 and larger. NOTE --For 125 and 150 Ib steam boilers: Globe ond check valves for feed line, quick action ond slow action blow-off valves are furnished. STANDARD EQUIPMENT (Water Boilers)--Steel saddle supports, refractory lined reor combustion chamber factory installed. Flue cleoner and hondle. Washout plug socket wrench. TRIM (Woter Boilers) --None furnished. Additional equipment or trim at extro cost rtft ** M-800 "a great teammate for any quality OIL, GAS OR COMBINATION OIL-GAS BURNER if4 C'^Ol kV JP, A The Kewanee M-800 Boiler is ideal for use with any quality Oil, Gas or Combination Oil-Gas Burner to form a complete Boiler-Burner Unit. A few of the many features which make this boiler so adaptable to Boiler-Burner Units are . . . complete range of sizes for both high and low pressures . . . unusual strength and dependability . . . ability to pro duce far above rated capacities at highest efficiencies . . greater heating surface . . . ease of cleaning and inspection . . . steel skids that eliminate special base construction . . . only two or three matching connec tions to make in mounting burners to boiler frame. KEWANEE-ROSS CORPORATION Division of American Rod<ato< L Standard Sonitory Corporation KEWANEE, ILLINOIS Catalog 98 40M 7-53 S.P. Three Boiler-Burner Units de veloped using the M-800 Series are shown above. For additional information on these units, write for separate catalogs. Litho in U.S.A. -VUV