Document 15Doay5Z1bJQKxZ5x6yEKyyEX
THE PROPER HANDLING OF AROCLORS AND THEIR MIXTURES IN THE ELECTRICAL INDUSTRY
Monsanto
_U .
Monsanto Chemical Co. Organic Div. Sales Dept. 800 N. Twelfth Blvd. St. Louis, Mo.
P. G. SENIGNUS may t, 1956
014*679
TOWOLDMON0023163 WATER_PCB-00007632
i
INDEX
I Introduction I Chapter 1 0 D Chapter 2 I Chapter 3
The Proper Handling of the Aroclors and Their Mixtures in the Eleotrical Industry.
Procedure for Unloading Tunkcars of Aroclora and Their Mixtures. A. Description of the Cars. B. Procedure for Unloading the
Cars. C. Drum Packaging
Storage Tanks A. General Description of
Storage Tanks. B, Detailed Description of
Storage T-nks.
Gasketing and Pump Packing.
Chapter 4
Sampling.
Chapter 5
e Chapter 6
Chapter 7
Laboratory Analysis and Procedure for Treating Aroclors and Their Mixtures.
Test Procedures.
Typical Properties.
Chapter 8
Earth Treatment of Aroclors and Their Mixtures in the Electrical Industry Prior to Use.
a Chapter 9
Dermatology and Toxicology.
K Attachments: Drawing No. 31-20848, Dome Detail. Drawing No. 31-20847, The Tank Car. Drawing No. 9C-8170-5, The Horizontal Storage
I Tank, Drawing No. D-13362, The Vertical Storage Tank. Drawing No. 9C-8243, The Breather. Drawing No. 90-8278, The Varec Gauge. Drawing No. 90-8178, The Unloading Platform.
i*6eo
|
TOWOLDMON0023164 WATER_PCB-00007633
THE PROPER HANDLING OF AROCLORS* AND THEIR MIXTURES IN THE ELECTBTICAL INDUSTRY
INTRODUCTION
Monsanto's Aroclors*, especially the ohlorlnated biphenyls including types 1242, 1248, 1254 and 1260, vised alone or in combination with chlorinated benzenes, are commonly used die lectric materials of the Askarell class.
Askarel is a generic name referring to liquid dielectrics derivftd;creflj halogenated aromatic hydrocarbons possessing excellent chemical and dieleotric stability and fire-resistance over the temperature ranges and operating conditions required of transformers and capacitors in the electrical industry.
The properties of Aroclors and their mixtures, used as dielectrics are described in detail in Chapter 7 entitled, "Typical Properties". These dielectrics are manufactured under very carefully controlled conditions in order to meet the strict and exacting electrical requirements and properties.
The electrical industry's use of these fluids has been largely in acoordanoe with the General Electric Company's patents and developments.
"Aroclors - Monsanto's chlorinated biphenyls and chlorinated polyphenyls. Registered U.S. Patent Office.
*?. M. Clark, "Electrical Insulation", Chem. Eng. News 25 , 2977 (1947).
1
014 4681
TOWOLDMON0023165 WATER_PCB-00007634
Resulting from the wide use of these materials in the industry, trade names have been established to identify them by different manufacturers of electrical equipment, LiBted alphabetically the trade names Include, "Chlorextol," Allis Chalmers; "Diaclor," Sangamo Electric; "Dykanol," Cornell Dubilier; "Elemex," Line Materials; "Hyvol," Aerovox; "Inerteen," Westinghouse Electric; "Noflamol," Wagner Electric; and "Pyranol," General Electric Company.
The purpose of this bulletin is to assist the industry With'theoproper and safe handling of these dieleotrlc materials in their operations.
01*4682
TOWOLDMON0023166 WATER_PCB-00007635
CHAPTER 1 PROCEDURE FOR UNLOADING TANKCARS OF AROCLORS AND AROCLOR MIXTURES
A, Description of the Cars Aroclor and mixtures of Aroclors with chlorinated benzenes
are shipped by Monsanto In two types of Insulated tankcare both of which are either aluminum lined or zlnc-tlm metallized. One type of ear has heating colls Inside of the tank and these are in direct contact with the product. The other, a more widely used type of car, is a double-shell tank with heating oolls between the Inner and outer shells. The steam coll connections are at the bottom of the car. Both types of tankcarB are tested for 60 pounds pressure and their steam coils are tested for 200 pounds gauge pressure.
The cars are top-unloaded by displacement with dry air containing 10 mg. HgO/cu. ft,, maximum.
There are two or three connections on the tankcar dome depending on the type of oar,, Where three connections exist, one is a two Inch diameter unloading line which extends to the bottom of the car, the second is a one inch diameter air inlet connection and the third is a two inch diameter pressure safety vent, which is a thin lead disc adjusted to release any pressure in excess of 60 pounds gauge,, This safety vent is hooded for protection against dust, dirt or accidental bumping.
Where only two connections exist on the dome, one is the two inch diameter unloading line and the other is the safety
3
01 <<'.683
I
TOWOLDMON0023167 WATER_PCB-00007636
vent. On these ears, it is necessary to remove the safety vent and introduce the displacement air through that connection.
Drawing No, 31-20848 shows in detail the dome of a tankcar with three connections. "A" is the two inoh unloading line which extends to a small sump at the bottom of the car. "B" is the one inch air injet oonneotion. "C" is the hooded safety vent. The car dome oover with fitted bolts is shown in the center. It is fitted with a Oarlock 901 asbestos gasket or an ^Aluminum envelope Goetze gasket. ThiB drawing also shows a bottom opening in the car, '[hiB can be opened only from the inBide of the oar and its purpose is for oleaning operations. It has no use at all in unloading the ear.
Drawing No. 31-20847 shows the over-all dimensions of the 8,000 gallon Aroclor tankcar,, B, Procedure for Pnloadlng the CarB
The car should be spotted at an unloading dock similar to the one shown by Drawing NO. 90-8178. The car must be level and the brakes set properly. "STOP-Tankcar Connected" signs should be placed fore and aft the car to warn switching crews.
If it is raining or snowing or the humidity is extremely high, it is not advisable to open the car. In case the car must be sampled and opened during bad weather, a canvas canopy must be placed over the dome of the car. It is preferable to unload the cars under roof or inside the factory. Unless it is absolutely necessary because of following described situations
4
TOWOLDMON0023168 WATER_PCB-00007637
the dome oover should not be opened until ready for sampling. The dome oover is sealed with a standard railroad wire and seal, and Monsanto should be notified if this seal is foundbbroken upon receipt of the car.
The first step in unloading is to inspect the dome and clean around the dome cover to remove all loose dirt, water or snow. Wiping rags and a brush should be used to clean before the dome cover and connections are opened.
Then, the screwed hood over the air-inlet valve should be removed and this valve opened fully and left open while heating the car. A Weston or metal encased thermometer should be in serted through thiB air-inlet valve opening and the temperature of the interior of the car determined.
If the car temperature is below the caution temperature shown in the following Table 1, it will be necessary to take the special step of inserting a "hair-pin" heating coil through the dome of the car to preclude rupturing the tankcar seams during the heating period.
Product
ASTM Pour Point C,
Temperature00C. Below which Caution Must Be
Psed in Heating
Aroclor 1260
Aroclor 1254 Aroclor 1248 Aroclor 1242 Pyranol 1467 Pyranol 1470 Pyranol l48l
+ 30
+ 40
+ 10
4 20
-7
+5
- 19
- 10
Pre-heating is not required*
Pre-heating is not required*
Pre-heating is not required*
Except if the material has cooled be&ow -10C. and
crystals of scavenger have separated. Then, the material
should be heated to 70C. (158F.) until complete solu tion has been accomplished.
'
014*685
I
TOWOLDMON0023169 WATER_PCB-00007638
If the dome of the oar la to be ppened for the pre-heating operation. It Is necessary that It be covered with a clean canvas. Extreme oare must be taken to avoid getting dirt or moisture Into the oar.
It Is due to the relatively high viscosity of some of the Aroclors at low temperatures that It becomes necessary to form a column of molten material from top to bottom of the car. In the center, to prevent hydraulic pressure bulld-up which may rupture the tank shell If there Is too rapid localized heating; when employing the main steam ooils.
When such pre-heating Is required, a satisfactory vent hole can be made by Inserting a "halr-pln" coll (1/(5 Inch diameter brass, galvanized, or stainless steel pipe) Into the open dome of the car and Introducing steam through the coll until there Is a column of fluid Aroclor from top to bottom.
After the vent hole Is melted through the material to the bottom of the car, the "halr-pln" coll should be removed and the dome cover replaced and bolted.
Steam Is then Introduced Into the main colls. It Is recommended that the steam pressure be limited to 100 pounds gauge pressure, particularly In the case where the colls are In direct contact with the Aroclor. The steam ooll outlet should be trapped or throttled with a valve.
It will require eight to twenty hours to bring the material to pumping temperature - depending upon weather
6
TOWOLDMON0023170 WATER_PCB-00007639
conditions. It is essential that the air inlet valve be
open during the heating period in order to vent the tank.
Some calculations have been made to indicate the heat
requirements for an Aroclor oar. Data for an 8,000 gallon
car of Aroclor 1254 are:
Specifio Gravity
= 1.5
Specific Heat
= 0.26 BTU/lb./F.
Heat requirement for heating Aroolor from 30C. (86F.) to
110C. (230F.) is:
8000 x 1.5 x 8.33 x 0.26 x (230-86) 3,774,000 BTU.
For heating from 30C. (86F.) to only 75C. (167F.), the
heat required Is 2,110,000 BTU.
A nine horse power boiler operating at 80 psig produces
263 Ibs./W. of steam with no reused condensate. Returning
oondensate at 200"F. will increase the steam output to 296 lbs./
hr. at 80 psig.
In the first oase, heating to 110C., the over-all heat
transfer co-efficient is assumed to be too low to utilize the
100# capacity of the boiler. A value of 1500 for UA with an
average ^ T of l44F. indicates that the useable steam is
202,000 BTU/hr. or 226 lbs./hr. steam at 80 psig.
In the second case the ^ T is lower and the entire output
of the boiler is useable. Table II sums up the approximate
time calculated to heat Aroclor 1254.
0144687
I
TOWOLDMON0023171 WATER_PCB-00007640
TABLE II
Nine HP Boiler
Lbs. Steam/Hr. 30-110C.
3Q-750C.
100# cap.(no reused condensate) 75# cap.(no reused condensate)
100# cap.(condensate @ 200F.)
263 --
296
-- 9 Hrs 18 hrs.(86#cap) 12 Hrs
-- 8 Hrs
75# cap.(condensate 200F.) -- 18 hrs.(76#eap) 11 Hrs
Calculations on a five horse power boiler give heating times of the
following order:
Five HP Boiler
Lbs,Steam/Hr. 3Q-110C.
30-75C.
100# cap.(no reused condensate)
146
28 hrs.
16 hrs.
100# cap.(condensate @ 200F.)
164
25 hrs.
l4 hrs.
Aroclor oars can be heated by steam (80-100 pslg) to the proper
handling temperatures In a reasonable time by using a boiler source
oapable of producing 200,000 to 300,000 BTU/hr. The times given here
are approximate and will act as a guide until experience shows the
exact time for this operation.
0144668
8
TOWOLDMON0023172 WATER_PCB-00007641
The proper handling temperature for the various fluids is given in the following Table III, which indicates cor responding viscosity values:
TABLE III
Product
Handling and Pumping Temperature C
Approximate Viscosity, S.P.S,
Aroclor 1260
95 - 130
100 - 43
Aroclor 1254
75 - HO
100 - 42
Aroclor 1248
50 - 85
100 - 40
Aroclor 1242
35 - 75
100 - 40
Pyranol l48l
30 - 75
100 - 40
Pyranol 1467
20 - 55*
100 - 40
Pyranol 1470
15 - 45*
100 - 40
*If any of the scavenger is out of solution, then the
material must be heated at 70C. (158 F.) until it has dissolved.
Selection of pumping temperatures for any dielectric not
shown on this list or which may be developed in the future
should be based on a viscosity of about 100 Saybolt Universal
Seconds for average pumping and about 40 S.U.S, for, fast
pumping.
When the material has been heated to pumping temperature,
a one-half inch diameter pipe "cross" arrangement containing
a pressure gauge, air inlet, pressure relief valve to relieve
at 30 PSIQ, and vent connections, should be connected to the
dome air inlet pipe. Then the unloading line should be connected.
9
0144689
|
TOWOLDMON0023173 WATER_PCB-00007642
(At this point a sample is taken as described in Chapter 4,) Dry* air is then introdueed into the tankear and pressure built up to 15 pounds gauge. The two inch valve oock on the stand pipe is opened and the discharge pipe observed to be sure the liquid is being unloaded. To protect the seams in the tankear, the pressure must not exceed 30 pounds. The car will begin to unload at about 12 pounds pressure.
When the oar is empty, the air pressure will drop off rapidly and air will blow out of the vent on the receiving tank. The air flow may be stopped at this point and the tankear pres sure released through the vent valve on the Across" arrange ment. After Inspecting the car to be sure that it has been completely unloaded, all connections and dome cover should be closed tightly. It is essential that the empty tankear be sealed immediately after the car is unloaded in order to keep the ear filled with dry air during return shipment. As a final
It is essential that the displacement air used for
unloading be dried thoroughly by some dehumidifying
unit such as soda lime, activated alumina or similar
dehydrating agent drying; unit. It may be necessary
to recharge the dehumidifying unit each time that a
car is unloaded. For unloading a tankear of Aroclar
within three hours, 15 standard cubic feet a minute
of air at 15 pounds per square inch gauge pressure
^affla -10F, dew point should be supplied. If the
dry air unit is to be used only for unloading tank-
cars, a small single tower dryer unit containing a
self-contained reactivating heater is suggested.
Two manufacturers of air dryers of this type are:
C. M. Kemp Mfg. Co., 405 E. Oliver Street, Baltimore
2, Maryland and Pittsburgh Lectrodryer Corporation,
Foot of 32nd Street, Pittsburgh, Pennsylvania.
.
' \
TOWOLDMON0023174 WATEFLPCB-00007643
step, it 1b desired that a standard railroad wire seal be in serted through the slotted bolts of the oar fittings. Steam Bhould be released from the car coils and all condensate re moved from the coils by blowing with air with the steam trap by passed. All connections must be replaced aB received. Adequate care should be taken in preparing and sealing the car for return shipment.
Unloading with dry air as described is the preferred and recommended procedure because it is done with the car dome closed which avoids contamination.
If the car is unloaded by pumping out of the top, which required opening the dome, it is most desirable that the car be set inside of a building. If this cannot be done, then, a canopy or roof should be provided over the oar dome, and the unloading should be done when the weather is clear.
A centrifugal pump with minimum capacity of AO gpm. is suggested. It will be necessary to prime the pump and only clean AsKarel should be used to do this. Another method for priming the pump is to use a Penberthy steam Jet, No. 22A available from Penberthy Injector Co., 1242 Holden Ave., Detroit 2, Michigan.
If a flexible unloading line is used, it should be a flexible metallic hose. Rubber hose must not be used.
ombal
|
TOWOLDMON0023175 WATER_PCB-00007644
C, Drum Packaging ' Drum packaging la made with new and carefully Inspected 55-gallon drums. These steel drums are lined with a specially selected baked phenolic coating. An example Is NESCO No. 3 lining offered by the National Enameling and Stamping Company, Long Island, New York. Contents of the drums should not be heated by direct application of flame or strip heaters. Radiant heat from steam colls or hot air in a heated room Is to be pre ferred. The screw plug In the drum head Is fitted with a metal cap as a safe guard against tampering.
i
12 01**69;
TOWOLDMON0023176 WATER_PCB-00007645
CHAPTER 2 STORAGE TANKS
A. General Description The storage banks should be a minimum of 10,000 gallons
and preferably 12,000 to 15,000 gallons capacity to accommodate the normal 8,000 gallon tankears.
It Is preferable to locate the tanks above ground where they are easily accessible for any ohangeB or repairs. Under ground location presents difficulty in this respect.
Especially In cold climates. It Is preferable to locate the tanks Inside of a building. The tanks should be located conveniently with reference to the tankcar unloading facilities and the area where the dielectric Is used.
Although Aroclors are non-corroBlve to metals, corrosion or rusting of Iron and Bteel equipment (by oxidation) may occur resulting In contamination of the products. The resis tance of Aroclors to materials of construction Is given in Monsanto Technical Bulletlon O-P-115, entitled, "The Aroclors," Page 6.
Stainless steel tanks are very satisfactory but relatively expensive. Stainless steel pipe is relatively difficult to fabricate and it is difficult to make tight leak-proof connec tions.
Storage tanks may be of steel construction if properly metallized with zinc-tin or aluminum on the interior surfaces
13
014*693
|
TOWOLDMON0023177 WATER_PCB-00007646
coming in oontaot with the Aroclors. The metallizing should be done according to the following procedure:
1. Clean an area of the surface by sand blasting, or a similar method, to give a perfectly clean and roughened surface. The area cleaned should not be greater than can be completely metallized within a few hourB after cleaning.
2. If zinc-tin metallizing is used, a coating of zinc 0.005 IncheB thick should be sprayed on to the cleaned surface. This 1b followed immediately by a coating of tin 0.007 inches thick.
3. Aluminum metallized surfacing should be about 0.01 inch thick.
The detailed procedure for metallizing and cleaning is
outlined as follows: a) Sand blast, b) Coat with iron, 0.005 inches thick. (The purpose of this coating is to provide a rougher and better bond for the finish coat of aluminum or the zinc-tin combination.) c) Apply the selected finish coat, d) Fill the tank with tap water and warm it with steam, (if an open Bteam line is used, do not allow the steam to Impinge directly onto the metallized surface of the tank.) e) Drain the tank, f) Fill with cold
water and drain, g) Wipe dry with clean diaper cloth or other fabric relatively free of lint, h) Heat the tank to at least 100C. (212F.) to expell moist air. It would be beneficial to heat the tank, allow it to cool and pull dry air through it using a dehumidifylng breather in the air line, heat again etc. until the tank is full of comparatively dry air. i) Spray about 100 gallons of new, electrioal grade Aroclor (not high
14
0 1|
TOWOLDMON0023178 WATEFLPCB-00007647
in viscosity) or electrical grade trichlorobenzene onto the inner walls of the tank, washing the walls thoroughly (avoid breathing any fumes). J) Attach the circulating pump, the lines used, and the filter press fitted with dry paper and cir culate the fluid through the system and the tank. Install new dry filter paper several times in the presB during this dry ing and cleaning operation. Discard the dielectric fluid used for cleaning, k) Partially fill the tank with new Aroclor dielectric and analyze it electrically and chemically to de termine whether it meets specifications. If all tests are met, then fill the tank with the dielectric.
The tanks should be insulated using, preferably; glass foam beads as supplied by Dow-Corning or Libby-Owens-Ford. The suggested thickness of the glass Insulation is one inch mini mum to two inches maximum. The glass insulation may be covered with tar material commonly used for weatherproofing. Another type of insulation which may be used Instead of the glass is 85$ Magnesia-Wool which should be covered also with the weather proofing tar. The advantage of the glass insulation is that it Is not moisture sensitive as is the case with Magnesia-Wool.
If the Btorage tank is located outdoors, it is best that the insulation be covered with riveted or bolted tin sheeting painted with aluminum paint., This type of metal surfaoe weatherB well and Is cleaned easily. All piping must be gal vanized and screwed fittings must be back brazed to assure
15
0144695
|
TOWOLDMON0023179 WATER_PCB-00007648
tightness. All handling pipe lines must be traced with steam
lines and insulation applied over the two lines in order to
keep the handling lines and the material up to the desired
pumping temperature. Usually a one-fourth inch copper steam
line running parallel with the handling line will suffice.
Under very severe conditions of low temperatures, it would
be desirable to wind the steam line around the handling line
about two turns to the foot,
The tanks must be provided with ample pressurized heating
coll surface to supply sufficient heat to the material to bring
it to the proper temperature for pumping and handling as indi
cated In Table III. Heating coils should be either metallized
steel, or preferably steel coils which have been galvanized
after fabrication. It is recommended that the steam pressure
on all heating coils should not exceed 100 pounds per square
inoh gauge; lower pressures may be used where practicable.
It is essential that all steam coils be completely free from
even minute leaks since this will introduce water into the
product.
The steam coils may be introduced as "hair-pin" coils
through a manhole at the side and bottom of the tank, or as
is most often done, inserted through the manhole at the top
of the tankr.and then located near the bottom.
External heating coils located in the Jacket of the tank
may be used but this constrviction is more expensive and less
efficient than the internal colls.
16
TOWOLDMON0023180 WATER_PCB-00007649
The storage tanks may he fitted with a stirrer, either through the top, side, or bottom of the tank and the propeller blade should be located near the bottom of the tank. However, insertion of a stirrer through the side offers possible source of a leak and since these materials are homogeneous, it is not essential to provide such agitation for the purpose of mixing.
Adequate circulation can also be accomplished by using a centrifugal type pump. Gear pumps or other equipment where wear or chipping of metal parts may Introduce contamination should not be used. The pumps must be of the type designed to handle hot oil. All wetted pump parts should be either stainless steel or bronze. The centrifugal pumps must be provided with a deep stuffing box and proper packing used, as described in Chapter 3. As examples of pumps found com pletely satisfactory for this service, reference is made to Worthington Worthite pumps. Blackmer pumps, and Dayton Dowd Type C pumps for handling hot oil.
Also, a very satisfactory arrangement for mixing or circulating and pumping the fluid from the storage tank is to use a vertical sump pump such as a Taber pump.
All storage tanks must be amply provided with a dehumidifying breather such as soda lime, activated alumina, etc., units. This is essential to prevent moist air from coming in contact with the dielectric. A moisture content above 35 ppm
17
0144697
TOWOLDMON0023181 WATER_PCB-00007650
adversely affects the electrical resistivity of these pro
ducts. Provision should be made to preclude possible leakage
df the drier material back Into the storage tank and the drier
should be inspected periodically to make sure that It is open
and not plugged.
B. Detailed Description
Drawing No. 9C-8170 shows the detailed construction of a
horizontal 15,000 gallon storage tank for Aroclor and Its
mixtures which l*as been found completely satisfactory.
The various nozzles on this tank are used as follows, con
sidering them in order from left to right on the drawing:
3" nozzle 24" nozzle
Inlet for recirculation
For future agitator If required (not used)
3" nozzle
For soda lime or calcium ohlorlde breather connection
36" manhole
For Inspection, etc. The float gauge is located in the center of this manhole.
3" nozzle
Not used.
24" nozzle
For future agitator if required (not used)
3" nozzle
Not used
3" nozzle 18" X 26" Oval Nozzle
Filling Inlet connection For sump pump
3" nozzle
For thermometer well (see detail)
The two 24" nozzles were originally installed for installa
tion of agitators, if required. However, It has been found
18
0144698
|
TOWOLDMON0023182 WATER_PCB-00007651
unnecessary to use agitators In the storage tanks, and these nozzles could be omitted.
It has been found that circulation of the fluid by the sump pump, and Into the nozzle at the opposite end of the tank, for several hours gives satisfactory blending of the tank contents.
For pumping the dielectric from the storage tank, a "Taber Fump Co. all bronze 2-1/2" X 2" vertical sump pump with monel shaft has been found to be Quite satslfactory for the applica tion.
The liquid level gauge used In the storage must be gastight. The storage tanks are equipped with Vapor Recovery Systems Co.'s "Varec," gas-tight, automatic tank gauge as shown by Drawing No. 9C-B278.
The storage tanks should be provided with an operating plat form suitable to the customer's conditions of operation.
The dehumldlfylng units used as breathers on the storage tanks can be constructed as shown by Drawing No. 9C-8248. The upper portion of the chamber 1b charged with anhydrous soda lime or another drying agent. Periodic Inspection of the drying agent will show the formation of a cake of damp material on top about 1 to 1-1/2 Inches deep. This cake should be removed and fresh material recharged. Any suitable con struction similar to that shown on Drawing No. 9C-8248 may be used for the breather unltB.
Drawing No. D-13362 shows design detail of a 15,000 gallon
TOWOLDMON0023183 WATER_PCB-00007652
vertioal storage tank. The vertical type tank would seem especially desirable when insufficient space is available to accommodate the horizontal type tank.
20
0144700
|
TOWOLDMON0023184 WATER_PCB-00007653
CHAPTER 3 GASKETING AND PUMP PACKING
Aroclors and their mixtures soften and swell natural rubber
and many of the synthetic "rubber" materials. Such material
not recommended for use. Include Hycar P, Koroseal, Perbunan,
Neoprene, etc. These materials are known sources of contami
nation.
Suggested types of packing and gasketing materials include:
1. For Welded Flanged Pipe Connections: Garlock Packing Co., No. 901 or No. 7021, 1/8 inch asbestos fiber Bheet. A ring of thin aluminum drawn tightly at the flange connections may be used satisfactorily also.
2. For Pumps: Oarlock No. 234, No. 431, and Cheveron
No. 7050-C are satisfactory packings. Likewise, Durametalllc's spiral asbestos fiber may be used. Johns-Manville and others have comparable packing materials.
3. For Valves: Oarlock No, 117 braided packing or Its equivalent is suggested.
4. Other Resistant Materials: It Is Indicated that duPont's Teflon, poly tetrafluoroethylene Is not attacked by hot (l30c.) Aroclor and Is to be recom mended as a gasket material. Dow-Cornlng's Silastic, Silicone 180, Is very resistant to Aroclor and is suggested for gasket purposes.
5. In some oases cork impregnated under pressure with
Chrysler's Cycloweld 55-9 or Armstrong Cork Co.'s 1162-j and cured at 170C. may be used as a gasket material. These are baked phenolic type coatings.
6. Pipe Thread Compounds: When necessary to use pipe
thread compounds, the following should be satisfac tory if care Is taken to prevent the pipe compound from getting on the Inside of the pipe.
(a) Plastic Lead Seal--manufactured by Durametallic Corp.
(b) Ordinary white lead
. 21
01
TOWOLDMON0023185 WATER_PCB-00007654
Usually It Is not necessary to use pipe thread com pounds Blnce all screwed pipe fittings Bhould be sealed by back brazing. All new lines and fittings should be cleaned thoroughly by steaming (for two hours) and dried with air or heat.
22
TOWOLDMON0023186 WATER_PCB-00007655
CHAPTER 4 SAMPLING METHODS
1.) The ASTM Standard Method for sampling electrical insulating oils is described in ASTM Designation: D923-49. This describes glass and metal thiefs for sampling drums, cans, and tankcars. A specially designed thief or bomb for sampling tankcars is described, also,, A very good instrument of this type is the stainless-steel Baoon Bomb Thief with which samples of the liquid can be drawn from any level of the tankoar.
The ASTM procedure describes sample containers, their cleaning and Btorage.
Under general precautions,.the ASTM mentions that, "Samples of the fluid shall not be taken until the oil is at least as warm as the surrounding air, because cold oil may condense enough moisture from a humid atmosphere to affect seriously its insulation properties, (in the case of tankcar lotB, on some occasions there may be no choice, as it may be necessary to procure samples from a tankcar when the temperature is not above the surrounding air. On such occasions, the temperature of oil and air, also the humidity if possible, should be noted in the report of test results.) It is unde sirable to do any sampling when the relative humidity of the atmosphere exceeds 75 percent, and samples shall never be taken in the rain."
23
TOWOLDMON0023187 WATER_PCB-00007656
At the plants of several electrical manufacturers using Aroclor dielectrics, the practice is to switch the tankcars directly into the plant building or under roof before sampling and unloading.
These precautions in handling are taken to avoid any contamination of the fluids which are manufactured under very strict specifications. For example, the specification for ionizable chlorides allows no more than 0.10 parts per million. Moisture may not exceed 30 to 35 parts per million.
Tankcars are cleaned and prepared under close inspection before they are filled. When filled, and analysis shows the material in the car to be satisfactory, the car is then sealed with a standard railroad wire and seal inserted through the slots of the dome fittings.
Likewise, after the tankcars have been unloaded in the industry, it is requested that the dome fittings should be sealed with a railroad wire and seal.
2.) Monsanto Methods used for sampling tankcars differ somewhat from the ASTM procedure. The modified techniques are used because of their greater simplicity and they have been entirely satisfactory as employed over many years.
A sample is never taken when it is raining or snowing or when there 1b any chance of contaminated atmosphere moving in the direction of the ear. However, in oase of an emergency, during inclement weather, a oanopy is placed over the car dome before sampling.
TOWOLDMON0023188 WATER_PCB-00007657
A satisfactory sample bottle Is a five pint, round amber
glass, paoker type container fitted with a 38 millimeter Bake-
llte screw oap with an aluminum or tin cup liner. Bottles of
this description oan be purchased from the Northwestern Bottle
Company, 3144 North Broadway, St. Louis, Missouri aooordlng
to their No. A-7253.
Only new bottles and oape are used. When a shipment of
bottles Is received, the bottles are oapped Immediately and
stored in their receiving oertons. Prior to use, the exterior
of the bottles is wiped with a clean doth.
The simplest sampling dsvloe used is a clean stainless
Bteel or aluminum dipper. However, this is not a generally
preferred device because It permits sampling the oar from the
near surface, only.
The sampling device commonly used consists of a stainless
steel tube, Beven feet long with one end bent Into a hook, to
serve as a handle and on the other end there Is a stainless
steel bucket with a perforated bottom. This bucket Is ebout
5-1/4 inches inside diameter and 6 Inches deep to hold the
five pint bottle.
This bottle is held firmly by a stainless steel collar
made to slide along the shaft of the sampling devioe. This
oollar has a damp attachment for fixing it tightly into place
where desired around the neck of the bottle.
When a oar is to be sampled, a new sample bottle is
clamped firmly In the bucket.
All dirt Is brushed and wiped away from the car dome area
using a dean rag.
, ~2-`~
01*4705
TOWOLDMON0023189 WATER_PCB-00007658
The car dome la opened and the cap is then removed from the sample bottle.
The sampling device is inserted into the car so that the neck of the bottle is at leaBt twelve to eighteen inches below the surface of the fluid. The Bample taken is dis carded as its purpose 1b to rinse the bottle. A portion of the sample is used to rinse the interior of the bottle cap.
This procedure is repeated until a minimum of three rinses has been made; each time the sample"taken is not put back into the car. These rinses should be discarded.
Then the sample is taken and the oap of the bottle is screwed down tightly.
When the sample has been obtained, the car dome is.replaced, immediately.
The exterior of the cample bottle is wiped with a clean cloth and when returned to the laboratory it is further clean ed with a cloth dampened with pure trichlorobenzene. If the sample is to be shipped, the cap is taped with Scotch Tape.
The sampling device is also cleaned with pure trichloro benzene and is stored in a dust free, air conditioned.'room.
3.) Drum Sampling. A glass thief, thoroughly cleaned with pure trichlorobenzene and dried is used to sample drums.
ot^706
|
TOWOLDMON0023190 WATER_PCB-00007659
CHAPTER 5 LABORATORY ANALYSIS AND PROCEDURE FOR TREATING AROCLORS AND THEIR MIXTURES WITH EARTH A sample of the Aroclor or Aroolor mixture taken from the tankcar, or drums, as described in Chapter 4, is analyzed in the laboratory to determine its quality in accordance with the property values given in Chapter 7. For capacitor use, usually the important properties tested are resistivity, power factor, chlorides, and moisture. For transformer use dielectric strength, resistivity, moisture, and ohlorides are the important properties. If the sample is out of line with the shipping specifica tions, it is indicated that the sample has become contaminated. In this case, another sample is to be taken and the properties redetermined. If still out of specifications, the sample should be given treatment with earth. Treatment of the dielectric with conditioned Attapulgus earth will bring the electrical properties to the maximum attainable values. While there is complete agreement on the benefits derived from treating with conditioned earth, there is difference of opinion on details of the method, arising from factors such as the following. No doubt, there are differences in the absorbent power of various types of diatomaoeous earth with respect to removing moisture, impurities and additives such as stabilizers or scavengers from the dielectric
. 2j
0144707
|
TOWOLDMON0023191 WATER_PCB-00007660
materials. The size of the earth particles, temperature and
conditions of activation of the earth, the concentrations
used and the temperature, the degree of agitation and time
Interval at which the dielectric is given earth treatment
are all possible variables which are still being studied in
various laboratories.
The method used by Monsanto for treating the fluid with
activated earth in the laboratory is:
The absorbent is minus 800 mesh Attapulgus* earth ac
tivated Just prior to use by heating in shallow trays for four
hours at 400C. (752P.) or for at least twelve hours at
250C. (482F.).
At least one quart of the dielectric sample is placed
into a clean two liter Pyrex beaker or three necked flask.
The beaker or flask should be cleaned Just prior to use in a
manner similar to the procedure described in Chapter 6, Method
No. 11,751 "Procedure for Cleaning of Electrodes, G.E. cell
and Accessories".
The flask or beaker is fitted with a glass or stainless
steel agitator. Heat is applied using either a hot plate or
a Qlas-Col mantle and is controlled by a thermostat such as
a Fenwal thermo switch with a stainless steel sheath.
About 0.1 to 0.2# of the activated earth, based on the
weight?of -the liquid is added.
Attapulgus Division, Minerals & Chemicals Corp. of America, 210 West Washington Square, Philadelphia 5, Pennsylvania
28
0144708
TOWOLDMON0023192 WATER_PCB-00007661
The more viscous dielectrics such as Aroclors 1248 and 1254 are heated at about 70 to 80C. (1580 . 176P.) and the less vlsoous materials such as Aroclor 1242 and Pyranols 1481, 1467, and 1470 are heated at about 50 to 60 C. (122 to l40P.).
After heating and stirring the sample for about four hours. It Is filtered using a clean Pyrex glass suction flask and a buohner funnel fitted with a Whatman No, 1 or No, 3 filter paper. This apparatus and the bottle Into which the treated sample of dielectric Is transferred should have been cleaned In a manner similar to the cleaning procedure de scribed In Chapter 6.
The earth treated and "up-graded" sample Is then ready for final analysis of Its electrical properties.
29
01`><>709
TOWOLDMON0023193 WATER_PCB-00007662
CHAPTER 6 TEST PROCEDURES
A. General Information The Monsanto test methods described here with the special
equipment used are Borne of the control tests employed to main tain the quality of Aroclors for dielectric use. They are suggested as a guide for test work needed to Indicate the quality of the dielectrics used In the manufacture of electrical goods.
The most significant electrical tests made on Aroclors for capacitors are:
1. Dielectric constant, 2. Power Factor. 3. Resistivity. For transformer use the most significant tests of Aroclor mixtures are: 1. Dielectric Strength, 2i Resistivity, In both cases a significant chemical test Is corrosion chlorides. The following terms are defined: Dielectric Constant: The dielectric constant (sometimes called speclfltJ induc tive capacity) of any substance is equal to the ratio of the capacitance of a condenser when that substance la used as the
30
ot
TOWOLDMON0023194 WATER_PCB-00007663
dielectric to the oapacitance when there is a vacuum between the conductors (for all practical purposes air at ordinary pressures may be used instead of a vacuum).
Dielectric Strength: Dielectric Strength is the rupturing strength of an insulating material when subjected to voltage stress under specific conditions and expressed in kilovolts. Breakdown varies with the shape of the electrodes and does not increase directly in proportion to the thickness of the dielectric. Power Factor; The power factor of a dielectric is the ratio of the ener gy loss in the dielectric to the "apparent power" in the di electric. Resistivity: Resistivity is electrical resistance offered to the pas sage of a steady current. The volume resistivity in ohmscentlmeter of an oil is the ratio of the d-c potential gradient in volts per centimeter paralleling the current flow within the sample, to the current density in amperes per square centimeter at a given instant of time and under prescribed conditions. Volume resistivity is expressed in ohm-cm. The analytical procedures described in detail includes 1. METHOD NO. 11,751, "PROCEDURE FOR CLEANING OF
ELECTRODES, G.E. CELL AND ACCESSORIES." 2. METHOD NO. 11,608, "DIELECTRIC CONSTANT AND POWER
pflrypftp "
01*4711
|
TOWOLDMON0023195 WATER_PCB-00007664
3. METHOD NO. 11,605, "DIELECTRIC STRENGTH."
4. METHOD NO. 11,607, "RESISTIVITY."
5. METHOD NO. 10,126, "CORROSION AND CHEMICAL STABILITY."
6. METHOD NO. 10,118, "INORGANIC CHLORIDES."
7. METHOD NO. 10,087, "ACID NUMBER."
8. METHOD (MODIFIED) NO. 10,620, "MOISTURE (WATER)."
Detailed Instruction and Testing Methods.
1. METHOD NO. 11,751, "PROCEDURE FOR CLEANING OF ELEC TRODES, G.E.
Cell and Accessories.
a. The Electrode Cleaning Procedure:
1) Place the electrodes In hot electrical grade Trichlorobenzene for ten minutes.
2) Wash with unheated TCB.
3) Rinse twice with methanol and twice with tap water.
4) Place the electrodes In hot 10$6 Tri Sodium
Phosphate solution. Soak and heat for ten minutes.
5) Wash thoroughly with ".tap water.
CAUTION: After Step 5-- DO NOT TOUCH THE ELECTRODES WITH HANDS!
6) Wash with distilled water twice.
7) Dry in drying oven for at least two hours at 120C.
b. The G.E. Cell Cleaning:
1) Reclean the dell before use, when more than 8 hours have elapsed since the previous cleaning.
2) Follow the procedure for the electrodes
starting at Step 4.
.
32
014*712
TOWOLDMON0023196 WATER_PCB-00007665
o. Cleaning of the Accessories:
1) Apply the same cleaning procedure as given for the electrodes (Steps 1 to 7) to prepare the glaBS spacer and beaker for next test.
2) Clean the thermometer in the same manner as the electrodes, except for Step 7.
3) Place the wet thermometer (after Step 6) directly in position in the temperature Heating Unit (Modified Fisher Isotemp Oven) and allow to dry.
METHOD NO. 11,608. "DIELECTRIC CONSTANT AND POWER FACTOR."
I. Apparatus
A. Oscilloscope: Heathkit Model 0-6.
B. Constant Temperature Heating Unit: Fisher Isotemp oven. Model 13-245A, modified to include inter wall connectors,
C. A. C. Generator: General Radio type 1302-A.
D. Amplifier and Null Detector: General Radio type 1231-B with type I261-A power supply.
E. Capacitance Bridge: Oeneral Radio Co. Capacitance Bridge type 716-C.
F. Test Cells: G.E. type, concentric cylinder electrodes Catalog #1,559.663.
0. Class B driver transformer: This is used for 60 cycle measurements to excite the bridge directly from the domestic power line. It has 50 volts output with a 4800 ohm resistor in service.
H. Tuned Circuit Filters: General Radio Type 1231-PS (400 and 1000 cycle) and 1231-P3 (60 cycle). These filters aid in obtaining a more accurate frequency for the measurements by removing harmonics, noise, hum, etc.
33
TOWOLDMON0023197 WATER_PCB-00007666
II Adjustment of Controls on Electrical Apparatus A. On Panel No. 1 (Top Panel, Amplifier and Null Detector)
a. Turn the 4-way (main power) switch on the upper right hand side to the #3 position to determine the Dleleotric Constant at 1000 cycles. Turn this switch to the #2 position for measurements @ bU cycles.
b. Allow the equipment to warm up 10 minutes. c. Turn "GAIN CONTROL" to 6.
d. Depress "INPUT 0.03V." button. B. On Panel No. 2 (Oscilloscope)
a. Turn "INTEN,," to about the 12 o'clock position. CAPTION; Do not allow a high intensity Bpot to remain stationary on the screen for any length of time.
b. Using "ROR. POSITION" and "VERT. POSITION" controls center the image on the screen.
c. Adjust "POOPS" for sharp line.
d. Turn "FREQ. SELECTOR" to LOOKC. e. Turn "FREQ. VERNIER" to 80. f. Turn "VERTICAL GAIN" to 5. g. Turn "VERTICAL INPUT" tO "10 VOLT MAX.". h. Turn "HORIZONTAL GAIN" to about 20. i. Turn "SYNCHRONIZING" to + 20. J. Turn "SYN." to "EXT. SYN." k. Turn "GEN." to "SWEEP GEN."
34
Ol*1"
I
TOWOLDMON0023198 WATER_PCB-00007667
C. On Panel No. 3 (Capacitance Bridge)
a. Turn "RANGE SELECTOR" switch to "100 C" for 60 cycle measurements and to "1 Kc" for 1000 cycle measurements.
b. Turn "METHOD SWITCH" to direct.
o. Turn "DISSIPATION FACTOR" selector switch to "0".
D. On Panel No. 4 (oscillator)
a. Disregard this panel for measurements at 60 cycles.
b. On 1000 cycle measurements, depress the No. 10 "MULTIPLY BY" button.
d. Set "FREQUENCY DIAL" to 100. d. Turn "OUTPUT" dial so that pointer is at
the end of the arrow. e. Depress the "UNBAL. 5000 OHMS" button.
When all of the above adjustments are made, the electrical apparatus is ready for measurement of Dielectric Constant
and Power Factor.
Ill. Determination of Constants for the Apparatus
1. Carefully assemble the cell which has been cleaned and dried within the last 8 hours. Refer to Method No. 11,751 for the procedure to use In oleaning the cells.
2. Place the cell assembly in the Fisher oven which has been adjusted to 25C.
3. Connect the back wire inside the oven to the lead on the Inner cylinder of the cell and the front wire to the lead on the outer oyUnder of the cell.
35
0144715
TOWOLDMON0023199 WATER_PCB-00007668
4. Connect the cable from the capacitance bridge to the terminals on top of the oven so that the Inner wire of the cable goes to the back terminal and "the outside mesh casing of the cable"(the ground) goes to the front terminal.
5. Remove the thermometer from the top of the oven before going on with 'the test. TEis~Ts~Important.
6. Make all adjustments on the electrical apparatus aS direoted In Part I of this method.
7. Balance the bridge by rotating the "CAPACITANCE" and "DISSIPATION FACTOR" dials on Panel No. 3 until the wide vertical band on the oscilllscope Is adjusted to a minimum width.
8. Record the sum of the readings on the "CAPACITANCE" dial and vernier and call this value A.
9. Remove the beaker containing the cell from the oven and fill It vilth C.P. benzene .to a level 0.737 Inches (ca.3/4 inch) above the top of the concentric cylinders of the cell.
10. Adjust the temperature of the benzene to 25C. while stirring with a thermometer.
11. Replaoe the oell In the oven (at 25C.) and make the same electrical connections as in Steps 3 and 4. DO NOT Interchange connections.
12;. Balance the bridge again as in Step 7.
13. Record the Bum of the readings on the "CAPACITANCE" dial and vernier and call this value B.
14. Calculate the cell constant by the following equation:
Cell Constant, K B - A (this Is usually 2.27 u l.o around 70 mmfd.)
15. Remove the cell from the oven and balance the bridge as In Step 7 with the ''CAPACITANCE" and "DISSIPATION" "FACTOR" dials.
3d
oi-*'716
|
TOWOLDMON0023200 WATER_PCB-00007669
16. Record the sum of the readings on the "CAPACITANCE"
dial and vernier .and call this value P. (capacitance
of connecting cable,)
"
17. Calculate the CELL LEAH CAPACITANCE by the following equation:
CELL LEAD CAPACITANCE, G . A - P - K (this Is
"~
usually
around
3 mmfd,)
WHERE:
A : CAPACITANCE OP ENTIRE SYSTEM IN AIR (SYSTEM CONSTANT)
0 - CAPACITANCE OP THE CELL LEADS (CELL LEAD CONSTANT)
F CAPACITANCE OP CABLE AND WIRES WHICH CONNECT
THE CELL AND CELL LEADS TO THE BRIDGE. (CONNECTOR CONSTANT)
K . CAPACITANCE OF THE CELL ALONE (THE CELL CONSTANT)
Tabulate the system Constant (a), the Cell Lead Con stant (G), the Connector Constant (F), and the Cell Constant (K) on a piece of stiff paper and post them near the Instrument where they can be easllyrreferred to for comparison and calculations.
These constants must be checked at least once every three months and In all cases where the Dielectric
Constant and/or Power Factor are out of specification.
Measurement of Dielectric Constant and Power Factor on
Arpclors, Pyrariois, Inerteens, and Trl-Tetrachlorobenzene' Blends.
A. Test Run on Cell to Determine whether It Is Clean
and properly Aligned
"
1. Carefully assemble a cell which has been cleaned and dried within the past 8 hows.
36a 01**717
TOWOLDMON0023201 WATER_PCB-00007670
NOTE: Refer to method No. 11,751 for procedure to use in cleaning cells.
2. Adjust the oven control to hold at a temperature of 100C. for all materials except Trl-Tetra Blends. If a Tri-Tetra blend is to be tested, adjust the oven to hold a temperature of 25C.
3. Place the empty cell assembly in the oven and connect the back wire inside the oven to the lead on the inner cylinder of the cell, and connect the other"(front) wire to the lead on the outer cylinder,
4. Connect the cables from the capaoitanoe bridge to the terminals on top of the oven so that the inner wire of the cable goes to the back terminal and the outside metal casing (ground) "goes to the front terminal.
5. Allow 15 minutes for the cell to reach temperature equilibrium inside the oven.
6. Remove the thermometer from the top of the oven before taking any measurements on the bridge. This is Important.
7. Make all the adjustments on the electrical apparatus as directed in Part I of this method.
8. Balance the bridge by rotating the "CAPACITANCE" and "DISSIPATION FACTOR" dials on Panel No. 3 until the wide vertical band on the osollloscope screen is adjusted to a minimum width,
9. Reoord the sum of the readings on the "CAPACITANCE" dial and vernier and compare this value with the SYSTEM CONSTANT determined in Part II of this method.
IMPORTANT: If the value obtained in Step 9 does not agree with the System Constant A (Part II) within 5 uuf, the cell must be re-cleaned, re-dried, re-assembled, and the test run for the System Constant must be repeated.
NOTE: Although the above test run must be made prior to each analysis, the value obtained in Step 9 is not to be used in calculations but is to be used only as a check on the cleanliness and alignment of the' cell.
37
oi^nB
|
TOWOLDMON0023202 WATEFLPCB-00007671
B. Procedure for Testing Materials
10. Remove the cell from the oven and fill the beaker
with the material to be tested to a level 0.737 Inches (ca 3/4 Inch) above the cylinders of the cell.
11. Adjust the temperature of the sample to 100C,
(use hot plate; for all materials except Trl-Tetra blends. For Trl-Tetra blends, adjust the tempera ture of the sample to 25C. using an Ice-water bath If necessary.
NOTE; Stir sample continuously with a thermometer while adjusting the temperature.
12. Place the cell and sample In the oven and make the same connections from the cell to the bridge as In Steps 3 and 4. DO NOT Interchange connections.
13. Allow fifteen minutes for the cell to reach tempera ture equilibrium Inside the oven.
14. Remove thermometer from the oven before taking a measurement. This Is "Important,
15. Make the adjustment of controls on the electrical apparatus as directed In Part I of thlB method.
16. Balance the bridge by rotating the "CAPACITANCE"
and "DISSIPATION FACTOR" dials on Panel No. 3 until the wide vertical band on the oscilloscope screen Is adjusted to a minimum width.
17. Reoord the sum of the readings on the "CAPACITANCE" dial and vernier, and call this value X.
18. Record the sum of the readings on the "DISSIPATION FACTOR" dial and switch. Call this value D.
Calculationsi
Dielectric Constant *
X-F - G ------- K-------
Where:
X s Capacitance reading from Step 17. F Connector Constant (Determined In Part III G -.Cell Lead Constant (Determined In Part II) K Cell Constant (Determined in Part II) .
38
TOWOLDMON0023203 WATER_PCB-00007672
When assembling this booklet, a mistake was noted in the num
bering of the pages. No page
of contents is missing. Only number 39 was skipped. We are
pleased to insert number 39 as
a blank page for your conveni ence for notes, if you care to make any.
39
014*720
|
TOWOLDMON0023204 WATER_PCB-00007673
<f, Power Factor f x D -T~
Where: f m Test Frequency (60 cycles or 1000 cycles) f0 Frequency of "Range Selector" on Panel No. 3 D Dissipation Factor reading from Step 18.
NOTE: When D (dissipation factor) Is less than 0.1, the dissipation and power factors differ by less than 0.0005. Therefore, for our measurements, power factors and dissipation factors are equal.
Precision: (Reference: General Radio Manual for Model 716-C Capacitance Bridge)
a. Capacitance readings are precise to J 2 mmfd. x mul tiplier reading ( 0.2$G of full scale for each range) when the dissipation factor Is less than 0.01.
b. Dissipation Factor (Power Faotor) readings are pre cise to 4 0.0005 or t 2# of the dial reading which ever Is larger, for values less than 0.1 for D (Dissipation Factor).
3. METHOD NO. 11,605, "DIELECTRIC STRENGTH." a. Apparatus and General Information
The electrical equipment necessary to provide high voltage to permit the determination of dielectric
strength of liquid dielectric at commercial power
frequencies is basically quite Bimple.
The equipment assembled in the laboratory oonslsts of a high voltage transformer of good design and with a ourrent capacity of 2,^3 KVA and with equip
ment for control Of the voltage and a means of
measuring the voltage and to provide safety for
the operator. 40
TOWOLDMON0023205 WATER_PCB-00007674
It 1b enclosed In a steel gray crackle finished cabinet measuring 42* high, 22" wide, 17" deep and set on truck casters for easy mobility.
Protective equipment incorporated In this apparatus prevents the application of high voltage unless all safeguards are compiled with. The door on rear of cabinet must be closed. The cover over the oil must be all the way down and the voltage control must be at 0 position. Failure to comply with these requirements will prevent any action when the red button Is depressed. The test cupt. Transformers, Voltmeters, and Accessories The askarel testing cup type No. 224809 supplied by General Electric Company Is mounted on the top rear of the cabinet. It Is protected by a heavy plastic cover, hinged at the rear for accessibility to the receptical.
It Is equipped with safety contactor so placed that the circuit energizing the high voltage contactor cannot be completed unless the protective cover is completely lowered and In place. It Is impossible for the operator or anyone else to touch the testing cup when high voltage Is applied.
01**722
TOWOLDMON0023206 WATER_PCB-00007675
The High Voltage Transformer manufactured by the JCelly-Koett Manufacturing Co. is of the cloaed core, oil immersed, Bhell type design. Rated @ 81,000 volt @ 40 millarepers. it was recovered from a used X-ray machine, purchased quite inexpensively.
An auto transformer from the same X-itey machine is connected so as to limit the out-put voltage of the high voltage secondary to 50,000 volts.
The primary of the auto transformer is connected to the secondary of a 2-1/2 KVA powerstat variable auto transformer supplied by the Superior Electric Company.
Power to the powerstat is controlled by a 4 con tact 30 amp. solenoid circuit breaker.
The voltmeter mounted on top near front edge Is connected across the powerstat secondary and Is calibrated to read directly in Kilovolts in the range of 0 - 50 K.V.
The overload clroult breaker consists of a small relay connected between one side of the high voltage transformer secondary center tap and
42
,1^ oV
TOWOLDMON0023207 WATER_PCB-00007676
ground. It 1b adjusted to break contact on a current
drain of about 50 mill Hampers. The circuit for the
ooll of the solenoid circuit breaker Is wired through
the contacts of thlB relay.
Safety and Operating Controls
1) Door Interlock switch located on rear door.
2) Test cup cover Interlock switch.
3) Powerstat switch mounted on rear of unit arranged so that high voltage contactor cannot be closed unless powerstat Is at zero position.
4) Main power switch on front panel
5) Powerstat voltage control on front panel.
6) High voltage contactor push button on front panel (red).
7) Signal lamps mounted on top around voltmeter. Purpose and operation described In method of use.
b. Procedure
1) Ascertain that the temperature of the material under test Is 25 ( 0.5)C.
NOTE; Testing at other temperature Is likely to give variable results which may be misleading.
2) Shake the sample container so a3 to thoroughly mix the aBkarel before filling the test cup.
NOTE: This operation Is especially Important with used Aroclor as the impurities may settle to the bottom and the test may be misleading.
3) Rinse the testing cup three times with small portions of the sample to be tested.
43
I
TOWOLDMON0023208 WATER_PCB-00007677
4) Immediately after final rlnBe, fill the cup to a height of not less than 20 mm. (0.787 in.) above the top of the electrodes.
5) Rock the cup a few times in order that any entrapped air may escape. Close cover over oil test cup.
6) Allow to stand 3 minutes, CAUTION: THIS IS IMPORTANT.
7) Turn main toggle switch on front panel to "ON" (or up) position. Both green and amber pilot lights on the top at either side of the voltmeter will now glow.
NOTE: The green signal light is connected across the 115 volt in-put and denotes that line voltage has been applied to operating control circuit.
Amber light is connected in series with sensitive switch located under high voltage contactors and connected to its armature. It indicates that high voltage contactor is in its rest position and away from oontaots energizing auto transformer.
8) Turn voltage control (large knob on front) to extreme counter-clockwise position.
9) Depress red button on front. This energizes high voltage transformer and circuit breaker and is indicated by amber light going out and the red light directly over voltmeter will lighTH
10) Watoh the voltmeter and, while holding the button "IN", turn the voltage control at such speed that will cause voltage as indicated on' voltmeter to 'pise at a fate of 3 K.V, per second.
11) Note and Record the voltmeter reading at breakdown.
44
01*1*72%
|
TOWOLDMON0023209 WATER_PCB-00007678
12) Repeat the test until two successive break downs occur on each of two fillings of the test cup which do not differ by more than 10%.
Report the average value of these two readings (Step 12) as the Dielectric Strength. If the limit of the instrument is reached before breakdown, report the Dleleotrio Strength as 50 K.V. at 25C.
Cleaning of the test oup; After the test Is completed, drain the oup. Plush the cup with benzene.
Then fill with Aroolor 1248 and let stand, until the next analysis. NOTE: An exception, when Bamples of oil from the plant are brought in for test, the cup must be thoroughly cleaned with benzene and carbon tetrachloride before and after running the test. The electrodes: The testing oup has two electrodes. Both electrodes are movable and have twenty threads to the inch with index notches on both the electrodes and the
lock nuts. To set the Gap:
Arrange one of the electrodes and the look nuts with the Index marks In line. Move the other elec trode until it comes in firm contact with the first
electrode and lock it,
45 "
0144726
||
TOWOLDMON0023210 WATER_PCB-00007679
Now unscrew the electrode with the Index marks In line (Step 1) two complete turns and lock It. This will leave a gap of 0.1 Inch between faces of the electrodes.
Cleaning of the electrodes and the test cup free of carbon coating:
The following ASTM method of cleaning shall be followed when It is apparent from visual inspec tion that the electrode discs of the cup are coated with carbon.
Wipe clean with dry calendered tissue paper the electrodes and the test cup.
CAPTION: It is Important to avoid touching the electrodes with the finger or with portion of the tissue paper which has been In contact with hands.
Rinse the electrodes and cup with dry lead-free gaso line, StoddasS Solvent (or dry, waterwhlte Kerosene) until they are entirely clean. Care should be taken not to touch the electrodes or the Inside of the cup after cleaning so as to avoid possible contamination.
116
O*1 ov*
I
TOWOLDMON0023211 WATER_PCB-00007680
4. METHOD NO. 11,607, "RESISTIVITY." a. Apparatus: General Radio Company Megohm Bridge Type 544-B. This Is a combination of Wheatstone bridge and vacuum tube voltmeter for Indicating null. The direct measurement of resistance up to 1,000,000 megohms is made possible by the use of a vacuum tube detector which absorbs negligible amount of power.
The voltage applied to the unknown resistor is held approximately constant, regardless of the value of the unknown resistance, this condition is necessary to measure resistance properly.
The accuracy of the instrument in the range en countered in the measurement of Aroclor resis tivity, 100 to 1000 megohm is 4 6$,
The instrument is equipped with a 115 volt AC power supply which supplies all operating voltages for the bridge indicating circuits and In addition supplies 500 V DC for application to the material under test.
The instrument is completely enclosed in a waxed
finish shielded oak cabinet measuring 8-1/2" wide,
22-1/2" long and 8" high.
Approximate weight--26 pounds. 47
014*728
:
TOWOLDMON0023212 WATER_PCB-00007681
Test Electrodes: Two concentric niokel cylinders with feet, obtained from Oeneral Electric Company. The inner electrode has outside diameter of 2.8" and a height of 3.25" with area of 184 sq, cm. The outer electrode has an inside diameter of 3" and a height of 3.25" with area of 198 sq. cm. The distance between electrodes is, therefore, 0.1" or 0,254 cm.
By theory, electrode constant (K) area/length is 191/0.254 or 752 where average area is 191 sq. cm.
Also K 36 x 10" x C (farads with air as dielectric) or 11.29 x C (mmfd. with air as dielectric).
Olass Plate: Pyrex about 3-1/2" diameter with concentric grooves to assist in spacing electrodes. Obtained from Oeneral Electric Company.
Heating Unit: Assembled in the laboratory and is the same unit described in Dielectric Constant Apparatus (see Method Mo. 11,608; Equipment).
Procedure: l) Assemble the test cell. Place the recently
cleaned (within the last 8 hours--see Method Mo. 11,751, Step 9) electrodes in an 800 ml. beaker.
48
0144729
TOWOLDMON0023213 WATER_PCB-00007682
I 2) Measure the capacitance of the test cell (Ce)
according to Method No. 11,608 (Dielectric Constant and power Factor measurements.)
3) Fill the cell assembly until the liquid level is 3/4 inch above the top of the electrodes.
k 4) Heat the assembly on the hot plate to 100 ( 0.5)C.
r 5) Place the assembly Inside of the testing oven. 6) Attach top lead (+) on the megohm bridge to inner electrode.
0 7) Attach other lead to outer electrode.
0 8) Throw the three switches at the top of the megohm bridge to "ON" position.
0 9) Allow 10 minutes for assembly to reach temperature equilibrium inside the oven.
1 DANGER: Make sure control knob is in "CHECK" position. Stherwlse, painful shock will result if leads are touchecTT
p 10) Bring the galvanometer pointer to zero by turn
I
ing the "ZERO ADJUST" knob in the direction in which the pointer of the galvanometer should move.
b
11) Turn the control knob to "CHARGE" position for
0 30 seconds.
12) Turn the control knob to "OPERATE" position and
0 return the galvanometer pointer to zero by ad justment of the "MULTIPLY BY" switch and the
megohm dial.
0 13) Read after 30 seconds.
a Calculation:
Resistivity* - Megohm dial reading (Step 12) x
i "Multiply By" reading (Step 11) x capacitance of cell (Step 2) in mmfd. x 11.29 * 0.001.
l
49
01<i<i730
|
TOWOLDMON0023214 WATER_PCB-00007683
Report the result In units of 109 ohm-ora, Values of resistivity are qualified by designation
of temperature and voltage. These are for this test, 100C and 500 volts DC.
NOTE; It is Important that the produot under test, eleotrodes, and beaker be at uniform temperature for this determination,, Temperature variations In different parts of the sample will cause the galva nometer zero to change constantly and give misleading results.
CAUTION; Inasmuch as measurements must be made at a potential of 500 volts DC a shock hazard exists in the handling of this apparatus. With the control knob In the charge and operate position full voltage of the bridge (500 volts) is applied to the positive and low terminals and through the test leads to the electrodes. Do not attempt to handle the electrodes of the test leads unless the control knob is in the "CHECK" position. Possible penalty for failure to observe this precaution -- Painful Shook. .METHOD NO. 10,126 "CORROSION AND CHEMICAL STABILITY." a. Apparatus: fl.E. Corrosion Apparatus consists of
the following: 1) A Corrosion Flask - It is a 300-ml. Pyrex flask
50 '
0144731
|
TOWOLDMON0023215 WATER_PCB-00007684
with a ground glass 24/40 Joint equipped with a 12-inch Btralght tube as an air cooled con denser. The air-condenser Is painted on the outside with aluminum.
2) The Corrosion Apparatus: A translte box 32" long x " wiae x 5" deep. The top of the box represents a split translte board with 5 holes cut to fit the flasks.
The box is heated by two 500-watt, 15 volt G.E. Strip heaters with off-set terminals at one end (23.5" overall length).
The heating length of the heating element is covered by a copper strip 19-1/2" long x 4" wide x l/4" thick.
The temperature Is controlled by an automatic thermostat with temperature setting Indicator,
Procedure:
1) Roll a rectangular (2" x 4") piece of aluminum foil so that it will pass through a ground glass 24/40 Joint of the corrosion test flask.
CAPTION; Be careful that after rolling the specimen does not touch itself at any point.
2) Wash the aluminum foil (Step 1) scrupulously with acetone, distilled water, acetone, benzene, and chloride-free ether.
3) Then place the foil on a clean watch-glass and dry in an oven at 110C. for 30 min. After cleaning handle the specimen with tongs or fbrc'epB only.
4) Weigh accurately on an analytical balance the specimen (Step 3) at room temperature.
5) Drop the weighed aluminum foil into the chloridefree corrosion flask of the "G.E. Corrosion Appa ratus." Rinse out flask with sample and rinse end of condenser with sample.
51
>
TOWOLDMON0023216 WATER_PCB-00007685
6) Add 200 ml. of the product under test to the aluminum foil (Step 4 and 5).
7) Set the corrosion flask: In the corrosion test appa ratus.
8) Attach a 12-lnch straight-tube air-cooled condenser, the outside of which Is painted with aluminum.
9) Cover the exposed part of the flask with aluminum foil.
' IQ) Heat the flask for 6 (+ 0.1) hours at 210 5) C.
The temperature of the liquid in the test flask Is mea sured Indirectly using a thermometer Inserted through a cork stopper and Into similar liquid contained In an Iden tical flask seated adjacent to the test flask on the heating chamber.
11) At the end of the heating period, detach condenser from the flaBk before removing It from the hot plate.
12) Remove the flask from the hot plate and cover all of the flask with aluminum foil (when the flask is not on the hot plate.)
13) Without removing the aluminum foil covering of the flask, analyse the product (Step 6) remaining In the corrosion apparatus for:
a) Appearance, Color, and Condition. b) Inorganic (Free) Chlorides--Apply Method No. 10,118 c) Acidity (Acid Number) - Follow Method No. 10,087
14) With a pair of clean, straight nichrome tongs, remove the aluminum foil specimen (Step 5), wash thoroughly, dry and weight accurately on an analytical balance in the same manner &8 before (Steps 2, 3 and 4).
Report the corrosion as loss or gain in weight to the nearest 0.0001 g. and the Chemical Stability, as Indicated by the ana lysis of the products "After Corrosion Test", in the same way as reported for the original (as received) material.
51 A
0144733
|
TOWOLDMON0023217 WATER_PCB-00007686
6. METHOD NO. 10,118, "INORGANIC CHLORIDES.
a. Preparation of Standards:
1) Make a primary standard of 100.0 ppm by weighing 0.1648 g, C.P. NaCl into a chloride-free 1 liter volumetric flask. Dilute to the mark and mix thoroughly. Make a 10.0 ppm etandard by diluting 100 ml. of the primary standard to 1 liter, and mixing well. For every 0.1 ppm standard, dilute to 10 ml. of the 10 ppm standard to one liter and mix well. A 0,1 ppm beam ia considered the very faintest beam perceptible to the eye between 15-45 seconds after adding the AgNO- solution. If the beam intensity is not visible^at all, or if easily visible (too strong), discard the solutions and make new standards,
2) Weigh 20.0 g. C.P. AgNOj into a chloride free dark bottle. Add 20 ml. C.P. HNO- (chloride-free). Dilute to 200 ml. with water.
3) All solutions should be freshly prepared every two weeks and stored in glass-stoppered Pyrex bottles.
b. Light Source:
Employ the 2 battery Penlite flashlight, having a 3-4 mm. light aperture. New batteries must be used fre quently in order to perceive beams properly.
c. Procedure:
1) Thoroughly rinse two separatory funnels with chloride-free water three or four times. Then take an aliquot from each funnel in a test tube which has been rinsed with chloride-free water. Test these aliquots for Tyndall beams by adding 3-5 drops of AgNOo and allowing 45 sec. for full beam to evolve. Absolutely no dust or chloride beam should be present, (if beam is present, rinse all equipment with 1:1 HNOg and repeat Step 1).
2) When funnels are beam-free, drain out all the water except 50 ml. in one and 25 ml. in the other. Heat the water in both funnels to boiling. (Hold stopper while heating as steam may cause stopper to fail.)
52
|
TOWOLDMON0023218 WATER_PCB-00007687
3) Transfer 50 ml. of the sample from the Bample bottle at a temperature of 95-100C. into the separatory funnel containing the 50 ml. of boiling water. (As a precautionary measure, pour some of the sample from the sample bottle into a waste beaker before adding the 50 ml. to the funnel.)
4) Stopper the funnel and shake vigorously for at least 1 minute, venting frequently through the stopcock. (Care must be exercised at all times to touch neither 'the lower part of the funnel stem not the ground part of the stopcock.)
5) Allow the layers to separate and drain off the sample into the second funnel containing the 25 ml. of boiling water. (As before, drain off a few ml. of the sample into a waste beaker before draining the sample into the second separatory funnel.) It may be necessary to heat the sample when transferring the sample to the Becond funnel; e.g., Aroclor 1260.
6) Repeat step 4 and allow the layers to separate. Then drain off the sample into a waste beaker.
7) Combine both water extracts in one funnel and shake thoroughly.
8) Take approximately a 10 ml. aliquot of the water extract out through the bottom of the funnel into a 3/4" x 6" test tube. Again, first allow a few ml. to drain out before taking the aliquot. (The test tube used should be rinsed with chloride-free water several times before using.)
9) Add approximately an equal portion of chloridefree ether. (The ether is tested by shaking a portion of it with chloride-free water and testing for Tyndall beam at the end of 45 sec. If beam is present, wash ether several times with chloridefree water until washings show no beam after adding 3-5 drops AgNO^).
10) Shake the ether-water mixture until the emulsion in the Bample disappears and the water layer is completely beam free before adding AgNO^, If emulsion is difficult to break, add sample dropwise through the ether and then shake.
53
0144735
TOWOLDMON0023219 WATER_PCB-00007688
11) Add 3-5 drops of 10$6 AgNOo solution and test for chloride beam for 45 Bee. exactly. If no beam Is present at the end of 45 seconds, report as ^0.1 ppm. The very faintest of beams 1b considered 0.1 ppm. If beam Is stronger It will be necessary to compare with standards of 0.15, 0.20 up to 1.0 ppm, adding the 3-5 drops of AgNO? and comparing at the end of 45 sec.
The method Is precise to the nearest 0.1 ppm.
Report reBultB to the nearest 0.1 ppm.
7. METHOD NO. 10,087, "ACID NUMBER."
a. Reagents:
1) Nitration grade benzol.
2) Anhydrous methanol.
3) A saturated solution of phenol red (phenol sulfonphthalein) In methanol (approx. 0.1$).
4) A 0.01 N solution of KOH In methanol.
b. Procedure:
1) Place 100 ml. of benzol, 100 ml. of methanol and 0.5 ml. (pipette) of phenol red Indicator Into one of two clean dry 500 ml. Erlenmeyer flasks.
2) Neutralize carefully with the 0.01 N KOH (to be first definite pink color.)
3) Pour the mixture back and forth between the two flasks several times. If the solution is still neutral, divide it equally between the two flasks. If not, repeat steps 2 and 3.
4) Weigh (4 0.05 g.) Into one of the flasks a 75.0 - 5.0 g, sample and titrate with the 0.01 N, KOH until the sample matones the blank.
c.. Calculations:
Acid No. (mg. KOH/gram sample) - ml. 0.01 N KOH x t>.56 sample weight
54
ov" 1,73b
TOWOLDMON0023220 WATER_PCB-00007689
Report the results to the nearest 0.001 if they are below 0.1, otherwise to the nearest 0.01.
The method Is precise to 4 0.002 for acid numbers below 0.01 and to 4 0.01 Tn the range of 0.1 to 0.01.
NOTE 1: To convert mg. KOH/gram to mg. NaOH/gram, multiply by 0.715.
8. METHOD (MODIFIED NO. 10,620, "MOISTURE (WATER)".
a.Introductory Comment:
The Karl FlBcher Reagent titration method UBed In the analytical laboratory involves UBe of an analytical ba lance to weigh accurately about one drop of water used In preparing the standard. Since an analytical balance may not be available, the method has been modified and sues a purchased standard water solution as described below. AIbd, In the laboratory a "Dead Stop" potentiometrlc method for determining the end point Is often used. However, as this equipment may not be available, the procedure described below uses the visual indicator change for determining the end point.
b.Apparatus and Reagents:
1) Karl Fischer Burett, Automatic Pyrex No. 5750, 25 ml. capacity. Ace Glass Company, Vineland, New Jersey.
2) Water Standard in Methanol. No. SO-W-2 (l ml. 1 mg. H-0) Fisher Scientific Company, 2800 Jeffer son Aver, St. Louis, Missouri.
3) Karl Fischer Reagent Solution No. SO-K-2, Fisher Scientific Company.
c.Standardization of Karl Fischer Reagent
Into a 500 ml. clean, dry Erlenmeyer flask, place about 100 ml. "Anhydrous" methoanol (commerically available, 99.95$). Add Karl Fischer reagent to this blank until the first color change from lemon yellow. It is not necessary to read the burette at this point. Carefully pipette 50 ml. of standard watersolution Into the blanked methanol. Refill the Karl Fischer burette.Titrate the solution with gentle swirling to mix, until the same color is obtained as was obtained for the blank. Now read the burette.
55
TOWOLDMON0023221 WATER_PCB-00007690
Moisture value of K.P. reagent In terms of grams
H20 per ml.
(Moisture value of stand-
(Ml. Standard H20 solution) ;ard water solution in
gm. per ml. stated on
__________
label.)
____________
ml. karl Fischer Reagent "
d. Solvent Mixture:
Since the solubility of the different askarels varies, the following solvent mixtures are suggested:
Material
Anhydrous Benzene
Anhydrous Methanol
Pyranol 1478 Pyranol 1488
1467 Pyranol 1481
Pyranol 1495 All Aroolors
0 ml.
100 ml. 100 ml. 100 ml. 110 ml.
300 ml.
200 ml. 200 ml. 200 ml. 190 ml.
e. Procedure, "Visual End Point."
1) Place 100-300 ml. of dry solvent mixture (c) in a dry 500 ml, ground glass stoppered Erlenmeyer
flask.
2) Titrate the solvent with K.F. reagent to the vis ual endpoint, i.e., the first change from the yellow to reddish orange that persists for 30
seconds. Refill the burette.
3) Using a beam balance, weigh to the nearest 0.1 gram by difference, a sample containing 0,03 to 0.06 grams H20 into the flask.
4) Stopper and shake until the sample is in solution.
5) Titrate the solution with K.P. reagent to the endpoint described in Step 2. Record the volume of K.P. reagent used.
Calculation:
* H20 > ml. of K.P. reagent x HoO factor x 100 Sample weight
References:
Mitchell, J. and Smith, D.M., Chemical Analysis, Vol. 5, Aquametry, Intersciense Publishers, Inc., New York, (1948)
56
01<i4738
I
TOWOLDMON0023222 WATER_PCB-00007691
CHAPTER 7
TYPICAL PROPERTIES
The 1200 aeries members of the Aroolor family are chlor
inated biphenyls, and are made by chlorinating biphenyl to
approximately the percentage of chlorine, by weight, in
dicated by the last two digits of the serial number. For
example, Aroolor 1254 is approximately 54# chlorine on a
weight basis. Accordingly, these Aroclors are not single
or simple compounds. They are a mixture of isomeric com
pounds composed predominately of the ohemical compound in
dicated below as being their approximate equivalents
Aroolor 1242 Aroclor 1248 Aroclor 1254 Aroolor 1260
Triohlorobiphenyl Tetrachlorobiphenyl Pentachloroblphenyl Hexachloroblphenyl
For transformer use and some capacitor use where lower
viscosity is required for better low temperature operation
than offered by the above Aroclors, these products are mixed
with pour point depressants, particularly trichlorobenzene
resulting in various General Electric company Pyranols
described briefly as follows:
Transformer Pyranol 1467* 60# of Aroolor 1260
40# of Elec, Grade Triohlorobenzene
0,125# of Tin Tetraphenyl
Transformer Pyranol 1470* 45# of Aroclor 1260 55# of Elec, Grade TrichloroTetrachlorobenzene Mix ture
0,125# of Tin Tetraphenyl
*Use of tri-tetrachlorobenzene and tin-tetraphenyl scavenger is subject t<> G.E, patents and license: Royalty arrangements should be checked before using. Questions about license concerning the use of anthraquinone stabilizer for DC capacitors should be referred to Western Electric, 195 Broadway, N.Y.C,
* 57
0144739
|
TOWOLDMON0023223 WATER_PCB-00007692
Capacitor Pyranol l48l
15% of Aroolor 1254 25g of Elec, Oracle Tri-
ohlorobenzene
Detailed properties of all of these produots are given as follows:
AROCLOR 1242
PROPERTY
TYPICAL
Vlso. @ 37.8C, (ASTM D88) Speeiflo Gravity @ 25/15.5C.
(ASTM D287) Color, APHA
Condition Acidity, mg, KOH/g. Pour Pt., BC. (ASTM D97) Inorganic Chlorides, ppm. Refractive Index @ 25 C. Distillation Range (ASTM D20)
Corrected for stem and barometric pressure Corrosion
82 - 92 seconds Saybolt Univer 1.381 - 1.392
100 max. Clear 0.01 max, -14 or lower 0.10 max, 1.6245 - 1.6265 log 325C. min. 90g 36oC. max.
After heating with aluminum for six hours at 210C I 10C, the aluminum must not be oorroded either on visual or weight inspection and the Aroclor 1242 should meet the following specs:
Color, APHA
150 max.
Acidity,mg.KOH/g. 0.01 max.
Inorg.Chlorides,ppm 0.10 max.
Condition
Clear
Water Content, ppm
35 max.
Resistivity 100C. 500 volts
DC @ 0.1" gap
500 x lo9 ohm-cm*; min*
Dleleotric Constant 100C,,
4.7 - 4.9
@ 1000 cycles (ASTM D924)
Flash Point Cleve. Open Cup* l6oc., min.
Fire Point C.*
None to boiling point
Sulfates (ASTM-D117-31)*
_N_o_n_e
Fixed chlorine content (Carius)* 4l,5 - 42.5%
Specific Heat @ 25C.*
0.29
Evaporation @ 100C for 6 hrs,* 0,4g max.
Dleleotric Strength (KV)
35 Min.
(ASTM D877)*
*Not determined unless by special request.
58
014*7*0
I
i
TOWOLDMON0023224 WATER_PCB-00007693
AROCLOR 1248
PROPERTY
Vise. @ 54.4C. (ASTM 15-88) Spec. Orav. @ 65/15.5C.
(ASTM D-287) Color, APHA Condition Acidity, mg. KOH/g. Pour Point C. (ASTM D-97) Refrac. Index @ 20C. Diet, Range (ASTM D-20) Water Content, ppm. Reels. 100C. 500 v D.C.
@ 0.1" gap Dieleotric Constant,100C,
1000 oyole Dielectric Strength 25C.* Flash Point, (C.O.C.)* Fixed Chlorine (carlus)* Specific Heat @ 25C.*
TYPICAL
73-80, sec.Saybolt Univer. 1.404-1.4l4
100 max. Clear 0.01 max. -7, 1.630-1.631 343 - 373C.
35
500 x 10^ ohm-cm., min.
4.6
35 KV min. 193C. 47.5 - 48.5# 0.27
*Not determined unless by special request.
59
0144741
|
TOWOLDMON0023225 WATER_PCB-00007694
AROCLOR 1254
PROPERTY
TYPICAL
Vise. @ 98.9C.(ASTM D88) Specific flravity @ 65/15.5C.
(ASTM D287) Color, APHA Condition Acidity, mg.KOH/g.
Pour Pt. C.(ASTM D97) Inorganic Chlorides, ppm. Refraotive Index @ 25C. Distillation Range (ASTM D20)
Corrected for stem and Barometrio Pressure Corrosion
44-48 sec. Saybolt Dniver. 1.495 - 1.505
100 max. Clear 0.01 max, 7-12 0.10 max. 1.6370 - 1.6R90 10S6 366 - 3786C.
50# 372 - 383C. 90je 383 - 396C. After heating with aluminum for 6 hours @ 210C. plus or minus 10C, the aluminum must be oorroded either on visual or weight inspection and the Aroclor 1254 should meet the following specs:
Color, APHA
150 max.
Acidity,mg.KOH/g. 0.01 max.
Free Chlorides,ppm.0.10 max.
Condition
Clear
Water Content, ppm. Resistivity 100C.,500 v D.C.
@ 0,1" gap
35 max, 500 x 10^ ohm-cm., min.
Dielectrlo Constant, 100C 1000 cyoles
4.15 - 4.35
Dielectric Strength 25C*
35 KV., min.
Burn Point (ASTM D92)*
Higher than 350C.
Sulfates (ASTM D-117-31)*
None
Fixed Chlorine Content (Carlus)* 55 2 0.5# Evaporation @ 100OC. for 6 tars'!; 0.4# max.
Stability*
There shall be no liberation
of chlorine or chlorides when
the material is heated @ 100C
in glass vessels in contact
with air for periods of at least
one month.
Ageing Characteristics*
No loss In resistivity over
original value on heating in
air for 96 hrs. at 100C.
Specific Heat @ 25C.*
0.26
Not determined unless by special request.
60
TOWOLDMON0023226 WATER_PCB-00007695
AROCLOR 1260
PROPERTY
TYPICAL
Vise. @ 98.9C.(ASTM d88)
72 - 78 Sec. Saybolt Unlv.
Specific Gravity @ 90C,/15.5C 1.555 - 1.566
(ASTM D287)
Color, APHA
150 max.
Condition
Clear
Acidity, mg.KOH/g.
0.01 max.
Pour Pt.,C.(ASTM D97)
25 - 34
Inorganic chlorides, ppm.
0.10 max.
Refraotive Index, 25C.
1.6455 - 1.6470
Distillation Range (ASTM D20) 1m0u*: 385 _ 398C
Corrected for stem and
50* 390 4o4c.
barometric pressure.
. 420C.
Corrosion
After heating with aluminum
for 6 hrs. @ 210C. * 10C.
the aluminum must noE be cor
roded either on visual or
weight inspection and the
Aroclor 1260 should meet the
following specs:
Color, APHA
150 max.
Free Chlorides,ppm. 0,10 max.
Acidity,mg.KOH/g. 0,01 max.
Condition
Clear
Water content, ppm.
35 max.
Resistivity,100C. 500 volts
@ p.l" gap
_ 500 x lO^ ohm-om., min.
Dielectric Strength 50C.*
30 KV., min.
Dielectrio Strength 100C,*
30 KV., min.
Dieleotrio Constant 100C.
3.6 - 3.8
@ 1000 cycles*
Burn Pt. (ASTM D92)*
Higher than 350C.
Sulfates (ASTM D117-31)*
NOne
Fixed chlorine content (Carius)* 60 + 0,5*
Evaporation 9 100C. for 6 hrsin 0,2* max.
stability*
There shall be no liberation
of ohlorine or chlorides when .
the material Is heated @ 100C.
in a glass vessel in oontaot
with air for periods of at least
one month.
Specific Heat @ 25C.*
0.23
*Not determined unless by special request.
61
01i, 1)7*3
TOWOLDMON0023227 WATER PCB-00007696
PYRANOL 1481
PROPERTIES
TYPICAL
Viscosity @ 37.8C.
70 - 82 sec. Saybolt Univ.
Speo. Gravity @ 15.5/l5.5C Color, APHA
1.525 - 1.535 150 max.
Condition
Clear
Acidity, mg. KOH/g.
0,01 max.
Pour pt,, C.
-15 or lower
Inorganic Chlorides, ppm.
0.10 max.
Refractive Index @ 25C.
1,6205 - 1.6215
Distillation Range
Corrected for stem and
barometrio pressure.
First drop
205C. min.
25# max,
Below 270C,
90jg 380 - 395C.
Corrosion Test
Change in Weight
O.O56
Color, APHA
200 max.
Acidity, after test,mg.KOH/g 0.01 max.
Free Chlorides,ppm.
0.10 max.
Condition after test
Clear
Water Content, ppm.
35 max,
Resistivity @ 100C
500 volts, DC, 0.1"gap
100 x 109 ohm-em,,min,
Dielectric Constant (100C.,
1000 cycles)
4.1 - 4.6
62
OlV'l''4'
|
TOWOLDMON0023228 WATER_PCB-00007697
PYRANOL 1467
PROPERTIES
TYPICAL
VIbo. @ 37.8C.,(ASTM d88)
54+2 sec. saybolt univ.
Speoifio Gravity @ 15.5/15.5C
(ASTM D-287)
1.560 - 1.568
Color, APHA
150 max.
Condition
Clear
Acidity, mg. KOH/g.
0.01 max,
Pour Point, C. (ASTM D-97)
-32C. or lower
Inorganic Chlorides, ppm.
0,10 max.
Refractive Index @ 25C.
1.6137 - 1.6147
Distillation Range (ASTM DElO) 1st drop - 200C. min.
Corrected for stem and
Below 270C. - 40# max.
barometric pressure
90% - 395 - 4l5C
Corrosion
After heating with aluminum
for 6 hrs. at 200-220C.,the
aluminum must not be corroded
either on visual or weight in
spection and the Pyranol should
meet the following specs:
Color, APHA
200 max.
Acidity,mg,KOH/g. 0,01 max.
Inorganio Chlorides 5 max.
ppm.
Condition
Clear
Water Content, ppm.
30 max.
Resistivity, 100C. 500 volts,
0.1" gap
100 x 109 ohm-om.,min.
Dielectrio Strength, 25C.
35 KV., min.
Dielectrlo Constant, 100C,
1000 cycles*
3.7 - 4.0
Tin Tetraphenyl*
0.12556 4 O.Olje by weight
Burn Point, (ASTM D92)*
Hone up"to Boiling Point
Fixed Chlorine*
59.156 min.
Aro Formed Gases*
Less than I.O56
(Oxygen Free Liquid @ 25C.) Total combustible gases
Including carbon monoxide,
hydrogen and volatile hydro
carbons .
*Not determined unless by special request.
>1
63 0x^'>
TOWOLDMON0023229 WATER_PCB-00007698
PYRANOL 1470
PROPERTIES
TYPICAL
Vise. @ 37.8C. (ASTM D88) Speo. Gravity @ 15.5/15.5C.,
(ASTM D287) Color, APHA Condition Aoldlty, mg. KOH/g.
Pour Pt.,oc., (ASTM D97)
Inorganic Chlorides, ppm.
Refraotlve Index @ 25C.
Distillation Range (ASTM D20) Distillation Range (ASTM 3D20)
Corrected for stem and
barometric pressure First drop
3558 55# 65$ 95$ Corrosion
41-45 Seo. Saybolt Cniv.
1.563 - 1.571 150 max. Clear 0,01 max. -44C., or lower 0,10 max. 1.6075 - 1.6085
210C,, min. 238 - 256C.
275 - js55c.
380 - 400C. 390 - 4l5C. After heating with aluminum for 6 hrs. @ 200-220C., the aluminum must not be corroded either on visual or weight Inspection and the Pyranol should meet the following specs:
Color, APHA
200 max.
Acidity,mg.KOH/g.
0,01 max.
Inorg. Chlorides,ppm 5 max.
Condition
Clear
Water Content, ppm.
30 max.
Resistivity, 100C,, 500 v.,
0.1" gap
100 x 10^ ohm-om., min.
Dleleotrlo Strength, 25C,
35 KV., min.
Dielectric Constant, 100C!.,
1000 oyeles*
3.8 - 4.3
Tin Tetraphenyl*
0.125# + 0.01# by weight
Burn Point, (ASTM D92)*
None up"to Bolling Point
Fixed Chlorine*
60.5 * 0.5
Aro Formed Gases*
Total"combustlble gases In
(Oxygen Free Liquid 25C. cluding carbon monoxide, hydro
Electrical Stability*
gen and volatile hydrocarbons. After heating for 96 hrs. @
100C In a closed container,
the resistivity should not
deorease more than 10#
*Not determined unless by special request.
64
*4 '46
TOWOLDMON0023230 WATER_PCB-00007699
PYRANOL 1488
Vise. @ 37.8C. Speo. Orav. @ 15.5/l5.5C. Color, APHA
Acidity (Mg KOH/g) Water, ppm. Condition Refrac. Index 25C. Free Chloride, ppm. Pour Point, C.
Reels. @ 100C,, 500 v D.C.
1" gap Dielectric Strength (25C.) Corrosion!
Loss of Aluminum
54-- 2 Sec. Saybolt Onlv. 1.560 - 1.568 150 max. .014 max. 35 max. Clear 1.6137 - 1.6147 0.10 max. Lower than -32C.
100 x 10^ ohm-cm min. Over 35 KV
None Heating with aluminum for 6 hre. at 200-220C. The Pyranol after heating should meet the following specs:
Color, APHA
200 max.
Aoldity(MgK0H/g) .014 max.
Free Chlorides ppm ,10 max.
Condition
Clear
Dielectric Constant @ 1000
cycles @ 100C.*
3.7 - 4.0
Distilling Range (corrected)*
1st drop
200C. min.
Below 270C.
40# max,
90% point
295 - 4l5C.
Burn Point (ASTM D-92)*
None up to boiling point
Fixed Chlorines*
59.1% min.
Aro Formed Oases*
Less than 1.0% total com
(Oxygen-free liquid @ 25C.) bustible gases Including
carbon monoxide, hydrogen,
and volatile hydrocarbons.
Not determined unless by speolal request.
65
|
TOWOLDMON0023231 WATER_PCB-00007700
CHAPTER 8 EARTH TREATMENT OP AROCLOR IN THE ELECTRICAL INDUSTRY
PRIOR TO USE.
Aroclors and their mixtures supplied to the electrical industry must conform with most strict requirements sepoified by the industry as shown in Chapter 7. Since these products are sensitive to contamination from traces of impurities, they require careful handling in the industry when sampling or Btoring or using the materials to Impregnate capacitors or fill transformers.
Common contaminants to be avoided include moisture, lonlzable impurities, metallic impurities, such as rust or corrosion products from storage and handling equipment, and contaminants suoh as oils (mineral oils), lubricating oils or greases common ly used in qquipment or other processes in the eleotrieal industry.
Care must be taken to avoid contamination from contact with improper gaskets or packing materials, including natural and synthetic rubber and most plastic exclusive of certain Silicones and Teflon. Rosin solder fluxes, eto. may also introduce traoes of deleterious impurities. The dielectrics are also susceptible to the harmful action of ultra-violet light and, therefore, exposure to direct sunlight should be avoided.
The adverse effect of lonlzable impurities is especially pronounced in the low viscosity Aroolors such as Aroclor 1242
66
0144748
|
TOWOLDMON0023232 WATER_PCB-00007701
or Aroclor mixtures such as Pyranol l48l. In the case of more vIscoub fluids, such as Aroelor 1254, the lonizable Im purities are not so free to move about In the fluid and, con sequently, the more viscous fluids can be handled with less oare than required for the thinner fluids.
This Is especially pertinent In oapacitor manufacturing. When using the thinner type Aroolors to make capacitors that offer superior low temperature operation, the following types of trace contamination affeotlng the electrical properties of the dielectric have been experienced. Occasional droplets of perspiration from operators, when winding the oapacitor cores, have fallen onto the paper causing contamination in the finished units. Small amounts of Glyptal resin and simi lar sealing compounds used to seal tiny leaks In the vacuum Impregnating equipment or storage tanks have caused contamina tion. Also, small amounts of mineral oil entering the system have caused similar trouble. A small droplet of any of these materials In one or several liters of the thinner type fluids results in noticeable contamination, whereas It may not have as much adverse effect on the more visoous dielectrios.
To be certain that the fluids are free from traces of contamination. It is standard praotice to treat them with con ditioned dlatomaceou8 earth and then to filter immediately be fore use. Treatment with this earth by removing trace contam inants results in "up-grading" the electrical values, e.g,,
67
0144749
|
TOWOLDMON0023233
WATER_PCB-00007702
the volume-resistivity may be brought up considerably beyond the specification minimum or the normal valueB of the dielectric as received. Likewise, improvement in power factor may be ao oompllBhed.
The earth treatment recommended for use by the electrical manufacturers is qualitatively the same as used in the produc tion of the Aroolors and their preparation for shipment to the electrical industry. Treatment of the Aroolors with earth by the electrical manufacturers is a step required to assure that traces of impurity or contamination that may have been introduced during storage or handling in the eleotrical indus try have been removed and that maximum electrical values have been attained immediately before the dielectric is introduced into capacitors or transformers.
It is impractical for the manufacturer to furnish these dielectrics to the customer at the maximum attainable electri cal qualities because even with careful packaging, shipping, sampling and handling in the electrloal industry, these fluids may easily plok up traces of contaminants from opened tankcars, drums, pipe line, pumps, etc. However, as supplied according to the specifications, the fluids are readily "up-graded" by the earth treatment.
The type of dlatomaceous earth used is known as Puller's Earth, supplied by the Floridin Earth Company, Warren, Pennsyl vania, or the Attapulgus Division, Mineral & Chemicals Corp, of Amerloa, 210 West Washington Square, Philadelphia 55, Pa.,
68
014*1750
|
TOWOLDMON0023234 WATER_PCB-00007703
or their equivalent. Usually a minus 200 mesh size, regular volatile, is used and the qiality should be specified as for use by the eleotrioal industry. (Code 73122)
The earth as received needs to be conditioned and acti vated, after which it should be stored only a minimum length of time (about a day at the most) and In hermetically sealed containers, prior to use.
It is desirable that the earth be used immediately after it has been activated.
Activation should be done by heating the earth contained in stainless steel shallow trays for four hours at 400C. in a muffle furnace. If a muffle furnace is not available or the capacity by this method may not be great enough, the earth can be activated by heating at least twelve hours in an elec trically heated oven at 250C. Another method used is to pan dry and aotivate by heating at 100C. and using a strong vacuum, about 6 mm. of mercury. This latter method is used in connection with transformer work and the former methods are usually used for capacitor work.
In the place of pan drying, rotary driers may be used but their aotlon should not be so severe as to break the earth par ticles to the extent of producing powder which is difficult to handle in the subsequent filtering operations.
It is the consensus that the earth should not be heated above 400c. as this may cause collapse of the particles.
69 '
TOWOLDMON0023235 WATER_PCB-00007704
The amount of earth used is usually 0.1# to 0.3# based on the weight of the fluid. Larger amounts of earth can be used if the fluid is composed of only Aroclor or a mixture of Aroclor and chlorinated benzene or other pour point depressants. However, larger amounts of highly aotlve earth, in the range of 2# or 3#, would be expeoted to selectively adsorb scavengers or stabilizers from the fluids containing these additives.
This is especially of oonoern in handling the transformer fluids whloh usually contain scavengers such as tin tetraphenyl. For transformer work it is suggested that the earth be condi tioned and mildly activated by heating it at 100C. under va cuum, about 6 mm, of mercury. Not more than about 0.1# of earth based on the total weight of the transformer fluid should be used.
For treatment with earth, the fluid is put Into a suitable tank fitted with an agitator, heating coil, and a cover.
The proper amount of freshly conditioned earth is added and the mixture is agitated thoroughly and heated for about four hours.
The more viscous dielectrics such as Aroclors 1248 and 1254 are heated at about 70 to 80 C. (158 to 176F.) and the less visoous materials suoh as Aroclor 1242 and Pyranols l48l, 1467, and 1470 are heated at about 50 to 60 C. (122 to l40F.)
After about four hours oontact the material is filtered through a Sparkler or Sweetland or a comparable filter press previously fitted with filter paper liners such as supplied by
70
,
TOWOLDMON0023236 WATER_PCB-00007705
Carl Sohlelcher and Sohuel Co,, Ino., Keene, N.H, The paper la usually 25 tails thlok and must be dried at 100C. to remove moisture, prior to use in the filter press. The filtered dielectric material Is then ready for Impregnating capacitors or filling transformers.
In some cases, especially for AC capacitor work where the dleleetrio does not require addition of stabilizers and accordingly there Is no danger of removing such additives by repeated earth treatment, good practice is to use continuous earth treating, circulation and filtration with constant read ing of the resistivity of the filtered dielectric.
In Chapters 1 and 2 selection of proper materials of construction for the tankoars and storage tanks was discussed. It is equally important to select proper materials of con struction for the processing tanks used in the oapaoltor and transformer Industries and also for the imprgnatlng chambers used In making capacitors.
It Is preferable that this equipment be made of stain less steel or aluminum, or if It is of Bteel construction, the interior should be either zino-tln metallized or aluminum lined.
While Iron or steel equipment Is not regarded aB de sirable for handling the fluids, this type of construction is used In some of the plants. Here the possibilities of rust ing or corrosion cannot be overlooked. If the equipment is kept free from water and If a film of clean dieleotrlo adheres
71
0144753
^
TOWOLDMON0023237 WATER_PCB-00007706
to the surface of the metal, e.g. when the tanks are empty, then satisfactory operation can be experienced.
However, a number of factors must be kept In mind and to cite an example, reference Is made to the Impregnation of capa citors by the chamber method. The moisture content of the paper used in the capaeitor oores may easily introduce several gallons of water into the average Impregnating ohamber. This water is removed from the eapaoltors prior to impregnation -- usually by heating the chamber to about 130C. under efficient vaouum, 100 microns or less. If the ohamber is not made of the preferred materials of construction, slight corrosion may occur and the film of fluid on the interior surfaoe of the tank may be contaminated and In turn introduce traces of impurities into the treated and clean dielectric subsequently introduced into the chamber for impregnating the eapaoltors. In fact, because of this possibility of contamination, in some operations the oapaeitors are conditioned and dried preparatory to impreg nation in a separate oven or chamber and when thoroughly dried they are then transferred into a second chamber used for impreg nation.
In the case of relatively large size capacitors, such as power factor correction units, a manifold pipe system may be used to handle each unit individually rather than by the batchchamber method.
The unimpregnated capacitors are placed into an oven and vaouum is applied to the individual units attached to the manifold.
72 ' 0144754
TOWOLDMON0023238 WATER_PCB-00007707
When conditioned and dry, the dielectric is introduced into
the unit through the manifold, Care must be taken that moist
air or contaminants do not collect in the branch through which
the dieleotrio is introduced.
In addition to removing moisture, another purpose of the
heat and vacuum conditioning treatment given the capacitor
units prior to impregnation is to remove traces of impurities
Buoh as residual solvent from the metal cleaning operations
and from solder flux, eto.
The fluid is introduced hot into the evacuated capacitor
units. The more viscous Aroolors, such as 1248 and 1254,
are usually impregnated at 85 to 130C. The less viscous
and more volatile dleleotrics such as Aroolor 1242 and mix
tures of Aroclor with chlorinated benzene may be introduced
best at lower temperatures -- about 5C. optimum, 80<. max.
Table IV indicates desirable minimum resistivity values
of the dieleotrio materials when earth treated and ready for
capacitor impregnation and similar values of the material
following the process.
table: iv
Dieleotrio Aroclor 1254
Volume Resistivity Ohm-cm at
100C. and 500 volts DC,
Prior So
After
Impregnation
Impregnation
2.500 x 109
800 x 109
Aroolor 1242
1.500 x K>9
600 x 109
Pyranol l48l
600 x 109
400 x 109
73
TOWOLDMON0023239 WATER_PCB-00007708
In the case of new and freshly filled transformers using Aroolor dielectric mixtures. It seems reasonable that the power factor of a sample of the fluid drawn from the trans former should be In the range of about 5 to 12 per oent, measured at 60 cycles and 100C.
With field service of the transformer the power factor value Is expected to Increase somewhat. However, suoh a power factor lnorease alone does not seem to have harmful effeot on the operation of the transformer.
A more usual measurement used for transformer fluid is volume-resistivity. This value of the new dleleotrlo prior to filling the transformer should be about 500 x 109 ohm-om. at 1,000 cycles and 100C. The similar value of the fluid taken from a new transformer should be at'least, about, 50 x 109 ohm-cm and no lower than 25 x K>9 ohm om.
With long field service volume-resistivity values de crease somewhat but seem to level off around 10 x 109 ohm-om, with satisfactory transformercperatlon. However, if the voiumewreslstlvlty of the fluid falls below 10 x 109 ohm-om, the matter should be looked Into.
74
ov-*-7*6
|
TOWOLDMON0023240 WATER_PCB-00007709
CHAPTER 9 DERMATOLOGY AMD TOXICOLOGY Skin patoh tests using Aroolor 1254 (biphenyl Chlorinated to the extent of 54# by weight) applied to gauze and placed In oontaot with the skin showed no primary Irritancy or sen sitization, The tests were conducted under competent medloal supervision and the standard procedure reoommended by Drs, Louis Schwartz and Samuel M, Peck, Reprint No, 2552, Public Health Reports, Vol, 59, No, 19 (April 28, 1944) was used. If Aroolors are spilled on the skin, the skin should be washed in the usual manner with soap solutions. If accidental burns scour from contact with hot Aroolors, the burn should be treated the same as any ordinary burn. Aroolor adhering to the burned area need not be removed Immediately unless treatment of the burn demands It, in which case use soap and water or repeated washings with a vegetable oil. At ordinary temperatures Aroolors have not presented Industrial toxicological problems. If Aroclors are used at elevated temperatures In open systems, methods must be designed to exhaust any vapors arising. Experimental work on animals Indicates that the maximum safe concentrations of vapors In workrooms Is In the range of 1,0 to 2.0 milligram per oubio meter of air. This applies to all of the liquid Aroolors.
75
o\'`l7`>7
|
TOWOLDMON0023241 WATER_PCB-00007710
Laboratory technique merely requires keeping the hands free of the liquid and handling It under a well ventilated hood.
Looailzed or spot ventilation together with general work room exhaust Is recommended! for plant operations.
When sampling tankcars, canvas gloves and safety glasses or goggles should be worn. No Bpeolal clothing 1b required but the worker's garments should be laundered at least weekly and changed in case Aroclor or Aroclor mixture Is spilled on the clothes accidentally.
If workmen are exposed to Aroclor vapors at relatively high levels, as may be the case when opening a heated capacitor Impregnating chamber, a respirator should be worn during these short Intervals.
The many years of satisfactory and safe use of Aroclore and their mixtures with ohlorinated benzenes In the electrical industry for impregnating capacitors and filling transformers has demonstrated the industry's ability to handle these fluids without hazard to the workmen. It 1b a simple matter and in line with good "housekeeping" and personal cleanliness to exercize the suggested and required precautions In all cases.
76
oi^7*8
|
TOWOLDMON0023242 WATER_PCB-00007711
CD
(DP g>
a>_____ 2L
CD
01 4 7 59
TOWOLDMON0023243 WATER_PCB-00007712
TOWOLDMON0023244 WATER_PCB-00007713
VCJHT fttlK- PVKStAft-l
itAvt - y i 'O'
P*iiu*ll><rrTUtrT*crtf-Ka*e*-rxt Pwiij-
Monsanto Lhmieil Lompany BMMtrC CXVIttOM
ANNISTON. ALABAMA rma OiMiCNYk *i*ATwe*- T-*.^ A-
'WltMiWUtH WMBrmfKI-* U9 Mlb 8-SI-m uu !' i -o' DWG. NO. SC-S24*
U144761
TOWOLDMON0023245 WATER_PCB-00007714
TOWOLDMON0023246 WATER_PCB-00007715
0144/6.S
TOWOLDMON0023247 WATER_PCB-00007716
0144764
TOWOLDMON0023248 WATER_PCB-00007717
P fiP O Z -f
0144765
TOWOLDMON0023249 WATER_PCB-00007718