Document 1576GKe01nvwZMLbLjm5dBZ7m
FILE NAME Manville JMA
DATE 1976 Sept 30
DOC JMA293
DOCUMENT DESCRIPTION Report - Study of Asbestos Elimination Replacement and Personnel Protection - Prepared for the Naval Ship Engineering Center
102800240 102800240
30 September 1976
STUDY OF ASBESTOS ELIMINATION
REPLACEMENT AND PERSONNEL PROTECTION
Prepared for
Naval
Ship Engineering
Mr. A. Winer
Code 6101E
Center
Under
NAVSEC Contract N00024-76 Task 6101-30
By
Designers & Planners Inc. 3700 East West Highway 106
Hyattsville Maryland 20782
D Task 4476/50
502633
502633
,
woul
TABLE OF CONTENTS
Section
Page
1
1.0 Introduction
l
1.1 Scope
1
1.2 Approach
3 2.0 Results
3
2.1 Background
4
2.2 Protective Clothing
6 2.2.1 Coveralls
6
2.2.2 Shoe Coverings
7
2.2.3 Gloves
7
2.2.4 Hoods
8
2.3 Respirators
8
2.3.1 General
8
2.3.2 OSHA Requirements
9
2.3.3 NIOSH Requirements
10
2.3.4 Navy Requirements
10
2.3.5 Activities Involved
2.3.6 Identification of Approved Respirators
11
13 2.4 Welders Blanket
14 2.5 Asbestos Millboard
2.5.1 Kaowool M Board and Fiberfrax llot Board
14
14
2.5.2 Millboard Used in Boilers
15
2.5.3 Joiner Bulkheads PHM
16 2.5.4 Welders Booths
17
2.6 Pipe Hanger Liners
17
2.6.1 Present Requirements
19
2.6.2 Status of Liner Program
T 502634
502634
502634
=
y
gine
Rr
ee
>)
TABLE OF CONTENTS Cont'd
' Section
2.6.3 Resulta
2.7 Measurement Program 2.8 Miscellaneous Items
2.8.1 Fireman's Clothing 2.8.2 Asbestos Pump Vanes 2.8.3 Machinery Space Escape Trunks 2.8.4 Anti Sweat Paints
3.0
Recommendations
3.1 General
3.2 Insulation color coding 3.3 Technical Manual Revision 3.4 Respirator Air Supplies 3.5 Disposable Clothing 3.6 Pipe Hanger Liners
3.7 Millboard
APPENDIX A - Facilities and Agencies Consulted APPENDIX B - Item Control Recommendations
o
est
ii
;
X INTRODUCTION
1.1 Scope
Inc.
This report has been prepared by Designers and Planners D in response to NAVSEC Task 6101-30 under contract 024-76-
4451. The task concerns engineering studies of asbestos replace-
ment and personnel protection in Naval shipboard applications
Specifically the following subtasks were identified as part
of this task
a Consultation with the Navy Environmental Health Center with reference to equipment and protective clothing to be used during asbestos out selection of pass criteria for operations on asbestos containing materials and examination of the usefulness of electron microscopy
Preparation of Item Control Recommendations for entering new items into the Supply System
Determination of substitutes for asbestos millboard Provision of liaison with NAVSECPHILADIV on tests of asbestos substitute materials
Provision of support and liaison with NAVSECPHILADIV relative to substitutes for asbestos pipe hanger liners
Approach
In order to accomplish the task several actions were taken based largely upon the knowledge and contacts made during the preceding studies carried out under NAVSEC Task 6101-22 Those
actions included
o Consultation with each of the Naval Shipyards on the status protective clothing pipe hanger liners and the use of
asbestos millboard
the status of pipe hanger liner substitutes and test results and asbestos millboard substitutes o Consultation with vendors of protective clothing respirators and insulation oO Consultation with NAVENVIRHLTHCEN personnel on the asbestos
fail criteria measurement program and selection
of materials
Results of the study are discussed in Section 2 of this report which is organized as follows
Protective clothing
Respirators Supplied
Welders blankets Millboard
Pipe hanger liners Measurement Program
Miscellaneous Items
Recommendations are made in Section 3 of this report
502637
502637
04
ses On
2.0 RESULTS
2.1 Background
~
The U.S Navy in response to National safety and health requirements concerning asbestos has instituted procedures designed to insure reduced personnel exposure to this hazard These procedures include use of safety equipment ventilation and improved asbestos removal procedures Concurrent efforts have been initiated to define suitable replacement materials for asbestos containing products
OPNAVINST 6260.1 of 9 April 1974 specified limits of ex-
posure of Naval personnel to asbestos The Chief Bureau of Medicine and Surgery was assigned technical responsibility for evaluating asbestos exposures The Chief of Naval Material was directed to provide technical assistance to define appropriate industrial hygiene controls and develop remedial projects
NAVSEA Instruction 5100.2 24 October 1975 established NAVSEA policy on the elimination of asbestos in ship construction
and maintenance and directed actions to further reduce asbestos
exposure The following specific policy items were addressed
d Asbestos and materials containing asbestos shall not be
used in the construction overhaul repair and mainte-
nance of naval vessels nor shall such materials be used
in any facility or operational application where suitable alternate materials have been designated llowever in locations where asbestos materials are presently installed out operations shall not be performed for the sole
purpose of oliminating asbestos
502638
b This instruction applies to all unbestos containing materials but the implementation details are currently available for thermal insulation only As additional substiture materials are develoned appropriate speci-
fication and instruction revisions shall be made for
implementation of this policy
C. Personnel working with asbestos shall be provided with and be required to use protection and safeguards in
accordance with OPNAVINST 6260.1
Chapter 635 of the Naval Ships Technical Manual NSTM was
revised 15 April 1976 to eliminate asbestos containing insula-
tion bringing it into correspondence with MIL and related
specifications for asbestos free insulation Appendix A of Chapter
635 provides safety instructions for insulation workers
Under the title of Asbestos Replacement Protection
Program tasks were assigned in support of OPNAVINST 6260.1 and NAVSEA INST 5100.2 Subtasks were assigned to NAVSECPHILADIV for
tests of asbestos substitutes to NAVENVIFHLTHCEN for measurements of
asbestos contamination and program recommendations and to P as
e described in Section 1.1
roy
2.2 Protective Clothing
Appendix A of Chapter 635 of the NSTM states A.2.2
a Asbestos and fibrous glass handlers disposable coveralls and clothing in accordance with 29133 Navy providing whole body head hand and foot coverings for use by personnel exposed to
airborne concentrates of asbestos fibers shall be
provided Cloth hoods such as painters hoods shall
be worn for head covering Disposable plastic gloves
,
502639
rg
& aA
eo
shall be worn to protect hands Cloth gloves may
be worn inside the plastic gloves for
but shall not be used alone
Sleeven
comfort
hall ha
made secure at the wrist by use of flaps provided
or by use of masking tape Stock numbers for
coveralls by size are
Small Small Medium Large Large Large
NSN NSN NSN NSN NSN NSN
8415-00-601-0792 8415-00-601-0793 8415-00-601-0793 8415-00-601-0794 8415-00-601-0797 8415-00-601-0801 8415-00-601-0802
The Naval Shipyards were surveyed to find how acceptable were
the coveralls listed above and to find out what shoe coverings
and gloves were being used and their acceptability
It was painfully clear that the instructions contained in the
NSTM have not filtered down to the shop level as of 15 September 1976. At least four of the lagging shops in the eight yards had not seen the new Chapter 635 of the NSTM and were not aware of the clothing requirements
The Navy Clothing and Textile Research Unit Natick Massachusetts is the activity responsible for the development of clothing items and related specifications The Clothing and Textile Unit Defense Supply Agency Philadelphia Pennsylvania is the control
point The information contained in this protective clothing section
of this report is current as of 15 September 1976
Disposable protective clothing is widely available in plastic materials Polyolefin TYVEK is duPonts trade name for spun bonded olefin polyethylene polyvinylchloride and rayon are a few of
those materials While flame resistance varieas ll melt when ex-
posed to flame and under some conditions may cause serious burns
S
502640
|
4
2.2.1 Coveralls
A minated cellulogic material is calluacal ua Oe, OT
eee
from which the 29133 coveralls are made The specification
requires
that
the material
not melt or drip
in the
re
flame
One trade name for the cellulosic material is KAYCEL >.
test
Three users of the coveralls in the stock system MIL
29133 report general satisfaction with the items Every user reported that they tear easily when snagged on sharp objects Two users reported that the Large size is not large enough for some of their workers One previous user reported that the
stiching is inadequate and is now using double stitched KAYCEL
coveralls obtained on local purchase
One previous user found that the clothing did not breathe well enough and tended to creep and bind in the shoulder and crotch As a result that yard is using a launderable 60/40 cotton dacron blend coverall Several iterations of laundering procedure done under contract were required to get the residual asbestos fiber content down The problem was primarily in pocket areas pockets
are being eliminated
The remaining three yards are using local purchase disposable
coveralls made of TYVEK
2.2.2 Shoe Coverings
Two yards are using the shoe covering bootie in insula-
tion work that has been put into the system for nuclear workers NSN 8430-00-890-2079 These booties meet 82240 and are
562641 562641 562641
6
5625626 641 54 626411562641
vinyl chloride film Type , cluss 2 of 375 One of the two
yards is ordering the bootic to 82240 except for white or
color the stock numbered item is yellow green
Two other
yards are using plastic booties bought under local purchase Four
are not using any shoe covering vs a taping plastic to coveralls
2.2.3 Gloves
Three yards are using cotton gloves NSN 8415-00-268-8330 .
One yard is using a leather drivers glove vinyl coated cloth glove Three yards are
One yard is using a using disposable plastic
gloves of differing types two
yard for all applications
are using yard only
surgical gloves one
when handling cement
which irritates skin
2.2.4 Hoods
ae
Two yards are not using hoods Two are fabricating
ee hoods locally from cotton cloth Two are using a disposable hood
made of TYVEK One is using a hood which is part of an approved
fed respirator systems
are used NIOSH approval is for When fed respirators
which include specific hoods respirator systems of elements of the respirator system for example
Substitution
using one hood
in place of another technically invalidates the approval For
see Section 2.3
additional information on respirator systems
502642 502642 502642
502642
502642
502642
-)
2.3 Respirators
2.3.1
General
Basic standards are set by the Occupational Health and Safety & Health Administration OSHA The National Institute for uccupational Safety and Health NI05m acts in an advisory capacity to OSHA and among other duties tests and certifies items of safety equipment for workers such as respirators NIOSH prepares and publishes lists of certified products
The Navy by means of OPNAVINST 6206.1 and NAVSEAINST
5100.2 promulgated requirements for respiratory protection and
other protective devices for workers engaged in asbestos work
.
.
In additiothne Naval Ship Technical Manual Chapter 635 Appendix
A deals with the required protective devices
2.3.2 OSHA Requirements
These are found in CFR Title 29 Chapter XVII Section
1910.93 iii delineates three different classes of respirators depending on the expected concentration of airborne asbestos The type of respirators required vs the limiting air-
.
borne asbestos concentrations are given below Limit leiers either
to the ceiling or to the eight hour time weighted average
TWA Less than 10x limit 10 - 100 limit over 100x limit
Type respirator
A B 0
502643
502643
502643
502643
yD The current time weighted average limit effective 1 July 1976 is
2 asbestos fibers per cubic centimeter of air with a ceiling ex-
posure
extent
limit of 10 of exposure
tibers cannot
per cubic centimeters of air
Since
be predicted well it must be 427 sumed
the that
a shipboard worker engaged in asbestoasbs estos insulation removal would
require a Type C respirator
are defined as a supplied continuous Type C respirators
demand respirator which consists of a source flow or pressure
of respirable breathing air
control valve an orifice a
a hose a detachable coupling a demand valve or pressure demand
attaching valve an arrangement for
the hose to the wearer and
a facepiece hood or helmet Regulations for approval of respira-
tors are defined in 30 CFR Part 11 Approvals under these regu-
lations are issued jointly by the U.S. Department of the Interior
Mining Enforcement and Safety Administration MESA and NIOSH
Additional requirements relating to the air supply are found in OSHA regulation 1910.134 which requires tem-
perature monitoring of the air
The quality of air supply for human breathing is defined in the Compressed Gas Association Commodity Specification 7.1-
91966 Class D
2.3.3 NIOSH Requirements
NIOSH under authorization of the Coal Mine Health and
Safety Act of 1969 and the Occupational Safety and Health Act of 1970 provides a testing approval and cortification program
and develops performance
regulations
tests
and certifies
502644502644
protective devices and verifies the quality of manufacture of
these devices
Supplied respirators which are certified by NIOSH are given
by manufacturer and model number in Appendix G of the Dai report
on Task 6101-22 dated 30 June 1976.
It must be omphasized here
that these certifications are for complete Type C supplied air
respirator systems and any interchange of parts from different vendors would render the NIOSH certification invalid
2.3.4 Navy Requirements
General
The requirements for respiratory protection for personnel engaged in asbestos work are given in OPNAVINST 6260.1 and NAVSEA INST 5100.2 In addition Appendix A to Naval Ships Technical
Manual Chapter 635 NAVSEA 635-0000 calls out bafety
-
requirements for insulation workers
This chapter also referen-
ces Chapter 9880 Section II of NSTM Damage Control Practical
Damage Control
In general these three documents follow the OSHA and NIOSH requirements but to be in strict accordance Chapter 635 requires minor changes These are given in Section III Recommendations of this report
235 Activities Involved
Within the Department of Defense the Defense Supply Agency unit at Richmond Va controls Defense General Supplies including FSC 4240 respirators The Naval Construction Battalion Port
502645
10
&
Hueneme California prepares specifications for respirators
Edgewood Arsenal
,
Maryland
tests respirators
for the Military
services
GGG is the general specification for inspirators and
respirator assemblies Slash of respirators Supplied air
sheets specify individual types respirators are covered in the
following shash sheets
GGG GGG GGG
Respirator Assemblies Air Line
Facepiece Supplied Air
with
Respirator Assemblies Air Line Helmet Supplied Air
Respirator Assemblies Air Line with Disposable Hood Supplied Air
GGG is a supplied air respirator for abrasive
blasting operations and 10 and 11 have purifying units
The other respirators protect against gases and dusts In addition to the NIOSH approval requirement under 30 CFR Part 11
contain requirements for such aspects as lens
the specifications
quality marking etc.
GGG is a specification for disposable filter masks
2.3.6 Identification of Approved Respirators
An attempt was made to correlate the OSHA NIOSH and Navy
requirements for respirators with the applicable federal specifications and standards and to determine which approved suppliedair respirators had National Stock Numbers NSN and could be assumed to be in the federal supply system
To this end various codes in NAVSEC and NAVSEA were queried
11
hy
Supply as well as the Defense
Agency DSA Item Identification
'
Group
in
Richmond
Va
No correlation could be established
Therefore two pilnufacturers pilnufacturers pilnufacturers of this equipment vers
consulted and no correlation could be established It does not
air supplied respirators of an approved type are in
appear that
the federal stock system
502647
2.4 Welders Welders
*
-7t
rn
Red SuUeeerut~
completely satisfactory
are
While While
s of wateriale
Leen satisfactory 4
blankets cloths as
blankets
of number materialt materialt are are
rnese
gintroduce
available available for
stock
materials
Item these
system interim materials
NAVSUP
system
Recommendations Recommendations
prepared the follcwing Recommendations
Form Form 87 prepared
~ Appendix B
silica fabric (REFRASIL
. An ounce amorphous
1.
- UC 100-48
silica fabric (REFRASTL
2. . A ounce amorphous
coated with silicone yupber
silica fabric
3. . amorphous
C 100-48
}
ito to ounces REFRASIL
rubber (to
fabric coated with silicone
a. A fibrous glass
32 ounces FABRICOTE 1584
tee ee peony
re eteGrmg we
swe
ere ate
en ee qe
ee
yocuRet cette. OD
ak aad
erQ .OUTA * AMO OE.
epee VES
?
** ********
meet
eter y
sett
Coreen
fs we
eS)
RETAKE TARGET -
2.5 Asbestos Millboard
is intended for interior use to serve Asbestos millboard
fire surface flame spread as temporary protection against
neated gas
and against neids and cor-
liquid or solid objects
rosive liquids It is available in
3/16 1/4 3/8 and 1/2
sheet inch
form with thicknesses of 1/6 1/8 and widths of 42 inches and lengths
of 48 or 96 inches 351E
2.5.1 Kaowool M Board and Fiberfrax Hot Board
of Kaowool
NAVSECPHILADIV investigated the acceptability
M board and Fiberfrax cate high temperature
Hot Board as a substitute for calcium
insulation block 2819F This
silicheck
insulation block was sometimes
undertaken because 1 thick
was
are that M board and
in short supply Preliminary reports
e costs are consi-
substitutes however
Hot Board are acceptable
erate in thicknesses less
and they are not manufactured
Cerably higher
silicate is
inch
are that the " calcium Indications
than 1/2
~rpne and substitution should not be necessary
no longer in short supply
2.5.2 Hillboard Used in Boilers
NSTM 9510 Boilers defines methods for constructing boiler
furnace docks rear and sidewall is not called for and materials
linings The use of millboard
other than those listed under
be used only in an emergency
NSTM 9510.116 are to
502649
14
one inch thickness of NSTM 9510 calls for a
insulating block
next to the stoc
~"
ange
te 12 been rape
0 OTT Tae piler
furnace plans call for 1-1 or 1-1 inch of insulating block
next to the boiler casing Insulating block under 1-2819F
of 1 1-1 2 2-1 3 3-1 or
is supplied in thickness
millboard is sometimes used to
4 inches Therefore asbestos
block next to the
make up the required thickness of insulating
millboard it was
As an alternative to asbestos
boiler casing
sometimes been used {
that a layer of mineral wool has
reported
in the Naval shipyard use of
An example of the variance Philadelphia and Norfolk
millboard can be drawn between
asbestos
Naval Shipyard Shop 41 Boiler Naval Shipyards Philadelphia
millboard and had no need for stated they did not use asbestos
Naval Shipyard Shop 41 reported that
a substitute at Norfolk used asbestos millboard in 1/8 or 1/4 inch
they occasionally thicknesses to build up the required thickness of insulation
was the recent use
next to the boiler casings An example given the USS America CV66
of asbestos millboard in the boilers on
2.5.3 Joiner Bulkheads PH 1
bulkheads containing material was used as a bulkhead
An asbestos
on
and as some joiner liner in the engine compartment
as asbestos millboard but as the PHM It was not identified
as asbestos containing material
for the
The specifications
that asbestos free material
state
follow on PHM class vessels shall be used in its construc-
tion
502650
No retrofit is presently scheduled to remove the asbestos
containing material llowever when an ROH is scheduled replacement will be considered
2.5.4 Welders Booths No instances were found where asbestos millboard was being
used as dividers for welders booths These booths are normally
partitioned using REFRASIL or one of the many other fibrous glass
cloths available
16
502651
2.6 Pipe Hanger Liners
In some applications
line hangers which eunnost reduces heat transmission
asbestos tape or cloth has
7%
niping runs aboard
Some Naval shipyards have
been used to
mre 1
been sub-
stituting fibrous glass tape in those applications D Was 50-
quested to review the acceptability of the substitution
2.6.1
Present Requirements
General Specifications for Ships Section 505
For services below 200 degrees F. pipe hangers
shall be lined with a liner material to prevent the pipe clamp and
metal to metal contact between
are of dissimilar
pipe when the pipe clamp and pipe
matesreiravlisces from 200 degrees F up to 650 degrees F
to
For
shall be lined with a liner material
pipe hangers
contact between the pipe clamp
prevent metal and the pipe For services above
650 degrees
F.
mini-
mun contact hangers shall be used
the
For all hot services the hanger rod between
and resilient mount shall be of sufficient
pipe clamp
from being subjected to
length to preclude mounts F.
temperatures
in excess of 140 liner materials
degrees shall be
in accordance shall not con-
Applicable
with Table 6.
Asbestos liner materials
or reinforcing wires
tain any metallic particles
TABLE 6 PIPE HANGER LINER MATERIAL
Temp degrees F Up to 180
Over 180 to 450 Over 450 to 650
Liner material & Form
Synthetic rubber
channel block type or sheet rubber cemented to hanger clamp
Silicone rubber
,
Asbestos Felt Tape
Applicable specification 6855
class II 60 durometer
765 class II 60 durometer
1784 466 form IV or 1782 class I grade
MA or MA
17
p-
_
4
.
eh
7eS
TABLE 5
CONTINUED Zlotn
Sheet
466 form [, traue AA JE
Reinforced r 1763 class , grade M or
AMA ;
HH
Standard Drawings
Hangers pipe for surface ships Dwg # 810-1385781
For sound and vibration reduction the pipe clamp
shall be lined with 1/4 in thick rubber Liner
be in accordance with 6855 class 2 60
to
to 125
durometer for fluid temperatures up
For
piping with
fluid
temperatures above 125 a in accordance with SS-
liner of 1/8 in asbestos
between the
466 type IV shall be provided
'
pipe and clamp
for submarines Dwg # 5000-54823-1385782 5000-54823-1385782
Hangers pipe
exceeds 180 the following
wmhaetreeriaplispinsghaltlembpeerautsuerde in lieu of rubber 6855
specified in the list of materials
A
B C
D
Silicon rubber 765 Cirss II grade 60
Max 550 or Asbestos felt 20077 or
Asbestos tape 4117 Cl 1 metallic
XX or XXI Grade AA AAA or AAAA
wire reinforcing cloth 466 Navyships of a style containing not less than 90 percent asbestos
502633 50263350263 502633
18
2.6.2 Status of Liner Program
NAVSEC Philadelphia had previously been assigned a task to determine through shop laboratory test the acceptability of fibrous glass pipe hanger liners This is an ongoing task which has not been completed as of the date of this report
In conjunction with this an attempt was made by both NAVSECPHILADIV and D to determine if the Naval Shipyards had
used fibrous glass pipe hanger liners aboard ship in the - past
and if so had the application been satisfactory
Personnel in the Design and Production Departments of the
Naval Shipyards were asked to identify ships in which fibrous glass liners had been installed The following ships were tentatively identified as having had fibrous glass pipa hanger liners installed
SSM 596 SSN 618
Mare Island Mare Island
SSN 620
Portsmouth
SSN 635
Portsmouth
l, SSN 646
Portsmouth
SBN 664
Portsmouth
SBN 673
Portsmouth
880 674
Portsmouth
88N 676
_ Portsmouth
PF 1072 FF 1078
Charleston Charleston
502654
19
Three fibrous glass products have been identified
being used by the shipyards as pipe hanger liner material
ey
te
ni
Portsmouth Portsmouth
Charleston
ALFEA 7
Claremont 16
NSN *
2315-00-267-1362 8315-00-768315-700-7-67-11 6 26)
It was the intent of this task to identify and visit
several ships which had had fibrous glass pipe hanger linera installed and the liners would then be examined to see how well they had withstood counding vibration wetness etc.
2.6.3 Repuls
Since shipyard personnel could not positively identif on which piping system or in which compartments the -.necss been installed no ship visits were made
Without positive location of fibrous glass liners it would be costly and difficult to examine their performance cause in general the hangers and liners are enclosed by the
insulation covering the pipes To inspect the liner the inst
tion must be removed and subsequently it must be replaced
If inspection of liners in service revealed no damage it would not guarantee that fibrous glass would be an acceptal substitute in all applications for long term use because the conditions of use would not be known On the other hand if spection revealed damaged liners it could lead to a general
prohibition of use
')
Three fibrous glass products have been identified as * being used by the shipyards as pipe hanger liner material
Mare Island
ALPHA Catalog 3201
Portsmouth Charleston
Claremont 19T25 NSN 8315-00-267-16382315-00-267-1632 NSN 2315-00-267-16332315-00-267-1633
It was the intent of this task to identify and visit several ships which had had fibrous glass pipe hanger linera installed and the liners would then be examined to see how
vibration wetness etc.
well they had withstood pounding
a
a
a
Fs
2.6.3 Results
Since shipyard personnel could not positively identify
the liners had
on which piping system or in which compartments
been installed no ship visits were made
Without positive location of fibrous glass liners it
would be costly and difficult to examine their performance be-
cause in general the hangers and liners are enclosed insulation covering the pipes To inspect the liner
by the the insula-
tion must be removed and subsequently it must be replaced
of liners in service revealed no damage
If inspection
acceptable it wouldnot guarantee that fibrous glass would be an
substitute in all applications for long term use because the
conditions of use
spection revealed
be would not
known
damaged liners it
On the other could lead to
hand if in-
a general
prohibition of use
502635
G
Therefore it is believed that inspection of existing fibrous
glass liners would have limited value
If the two pipe hanger
liner drawings and the NSTM requirements are taken together
fibrous glass liners uss required only in the range 550 to
650
One option is to extend the use of limited contact
liners downward to include the range 550 to 650 650 to eliminate
the use of asbestos and the need for another substitute
2.7 Measurement Program
The Navy Environmental Health Center has been funded to conduct an asbestos measurement program and to make recommendations for changes to asbestos handling procedures and equipment
Discussions were held with the Center to transmit in advance of
this report our findings and what information we had gained since report on Task 6101-22
21 502656 502656
2.8 Miscellaneous Items
of the study a number of applications of asbestos
In the course
were uncovered or revi
flacussion flacussion of coun ve wildl 2 ovr
follows
2.8.1 Fireman's Clothing
P was asked to review the status of fireman's clothing
As with the disposable clothing the Navy Clothing and Tex-
tile Research Unit is responsible for fireman's clothing At
an present fireman's clothing is made from aramid nylon fabric 29143 backed
aluminized asbestos
up with a quilted lining
While the Clothing and Textile Research Unit is aware of the as-
bestos problem they are not funded in PY 1977 to develop a replace-
ment for the asbestos cloth
2.8.2 Asbestos Pump Vanes
The Auxiliary Equipment Branch NAVSEC 6153D has approved the substitution of Ryton Polyphelene Sulfide plus glass and Teflon filler for the previously used Melamine Asbestos in vane
Blackmer Pump Division of the Dover
pumps supplied to the Navy by
Corporation
2.8.3 Machinery Space Escape Trunks
To minimize heat transfer to ladders in machinery space
trunks the present design uses asbestos insulating pads
escape
between the ladder and the bulkhead In proposing redesigns which meet the intent of the General Specifications for Ships one of the
P is the use of non asbestos insulation criteria being assumed by
in the application
22
502657
&
2.8.4 Anti Sweat Paints
& was asked to investigate sweat paints of two types
1. Coating Compound Paint Antisweat 492C
2 Paint Retardant 15144 plus Vermiculite
15196
The coating compound FSC 8010 is controlled by the Federal
Supply except
Service 492C specifies the components of the for an extender which is nominally 90 by weight of
paint
the
pigment 27 of suppliers One antimony oxide
the product weight There are two approved supplier states that the extender is entirely
The other supplier states the extender is 20
diatomaceous silica and 71 asbestos by weight of solids
The fire retardant paint contains no asbestos The speci-
fication for vermiculite 15196 has been superseded by
585 Insulation Thermal Vermiculite which calls out ASTM
Standard C516 for Vermiculite No mention is made of asbestos
3.0 RECOMMENDATIONS
3.1 General
In the course of this studen a number of
77
ie
Discussion of those recommendations is presented below
3.2 Insulation Color Coding
The bulk of the insulation in Navy ships is block or pre-
formed insulation Use of such insulation containing asbestos is
but it is difficult to distinguish between
presently prohibited containing and asbestos forms of block and preformed
insulation during out
It is relatively much easier to dis-
tinguish between asbestos cloth and fibrous glass cloth
tween other forms of asbestos containing insulation and
and the
besub-
stitutes It is suggested that insulation manufacturers be re-
quested to color code the insulation for all users Manufacturers
have objected to the problems involved in setting up a separate line for Navy products In that way if in future rip noncoded insulation were encountered personnel would at least
be alerted to the danger color asbestos insulation installed up to the change over point would continue to be treated as though it were containing At present there is no way of knowing which material is being torn and there appears to
that the situation will be resolved at any point in
be no assurance
the future
3.3 Technical Manual Revision
It
through
is apparent Chapter 635
that the promulgation of safety requirements
of the Naval Ships Technical Manual is not
24
502659
rapid enough to insure compliance in a time hanner
Also
view of the unsettled status of protective dicthing and respirators
in terms of what is both safe and acceptable clear identification it is recommended that be revised to contain only policy statements mentation of those policy statements through
and in terms of
the Technical Manual and that the implerecommendations for
use of specific items of equipment or clothing be made directly
to the expected users For example
1 Change Appendix A to NSTM Chapter 635 relating to respira-
.
tory protection as follows
a Paragraph 2.b.l change type A class II to read
NIOSH Certified Type C supplied air respirators
b Delete paragraphs 2.b. & 2.b. for two reasons
is not NIOSH
one the specified breathing apparatus certified for this application and also these respirators are emergency equipment stowed in the damage
control locker and should be so reserved
2 Do not assign NSN's to supplied respirators Approved
respirators are available from industry in a timely
fashion via purchase wavrs nuthoriznuethordized Federal Supply
Schedule Catalogs by manufacturers item numbers The
respirators are under FSC Group
2390 New Item Introductory
4240 Example Item Schedule Contract Number
002-31030 Minnesota Mining & Manufacturing Co. St.
Paul Minn 55101 Dept. 220-7w
502650
However one problem is that fleet activities do not
normally have access to such documents For those activities data must be provided so that they can order suitable protective equipment The NSTM snoula not be relied upon to provide timely dissemination
This recommendation is made in light of the large number
of repair and replacement parts required for each model respira-
of various items of vendors equiptor and the fact that mixing
would invalidate the NIOSH Certifi-
ment is not only difficult but
cation
3.4 Respirator Air Supplies
Investigate the compatibility of these respirators with the applicable Of particular interest are the safety
existing air supplies for
USHA and NIOSH requirements
and standby devices per
OSHA regulation 1910.134
3.5 Disposable Clothing
3.5
As discussed above in spite of the instructions contained
in Chapter 635 of the NSTM lugging shops in the shipyards are
using a wide variety of clothing
items including n some cases
no protection It is also clear that there is some dissatisfaction with the disposable coveralls now in the stock system The
following are recommended 1 Request the Navy clothing and Textile Research Unit
to revise the existing specifications for disposable
coveralls 29132 for the material and MIL
29133 for the coverall to increase tear resistance revise the stiching add additional sizes and and
requirements to minimize creep and bunching
2 Since Recommendation 1 is expected to require a year to two years to accomplish as an interim solution permit the yards to use local purchase of cover-
alls
3 Review the fire safety requirements of the coveralls and if found to be a hazard prohibit the use of plastic disposable clothing such as TYVEK and vinyl
4. Request the Navy Environmental Health Center to determine whether KAYCEL clothing is adequate to protect against asbestos dust
27
5 Direct the Naval Shipyards to use full protective
clothing and supplied air respirators as described in Appendix A of NSTM Chapter 635 by more rapid
and direct means than the NSTM
6 Revise Chapter 635 of the NSTM to include the ratio-
nale for use of Class C supplied respirators i.e. that 100 X the 8 hour time weighted average limit or ceiling limit is expected to be exceeded
during any asbestos out
502663
3.6 Pipe Hanger Liners
1 Continue the effort to identify locations on the ships
fibrous glass pipe hanger liners were installed
If
listed where
such locations can be identified visit those ships to determine
acceptability
2. Continue laboratory tests being conducted by NAVSEC-
PHILADIV
that fibrous glass has not 3. Inform all Naval Shipyards
been approved as an acceptable material for and to use General Specifications for Ships
pipe hanger liners and Naval Standard
Drawings as reference for approved materials
4. Select a ship now in overhaul and install alternative
locations with the intent of liner materials in identified
examining the liners after say a years operating service
revise the General Specification and
5. Alternatively
to delete reference to asbestos
pipe hanger drawings and to require the use of silicone rubber 765
materials
up to
of 550 and minimum contact pipe hangers above temperatures
that temperature There are differences in application temper-
atures in the drawings and the specifications see 2.6.1
3.7 Millboard be found for millboard for which
Since no application can it is recommended that its use be prohibited
it is required
502664
o
APPENDIX A
~1
FACILITIES AND AGENCIES CONSULTED
Fodoral Supply Service
Paints
Mr. Baldeman
Defense Supply Agency Richmond Va
Item Identification
Oakley
Engineering
Mr. Woods
212 212
557-5357
695-4410 695-3664
U.S. Navy Portsmouth Naval Shipyard
Shop 56 Superintendent
Shop 56 Planner Code 260.12
Mr. Parent Mr. Patch
Legere
604-2364 684-2350 684-2293
Philadelphia Naval Shipyard
Shop 56 Asst Supt
Code 262
Seas
Shop 41
Sweeney Wolfe Hilton
443-3320 433-3387 433-2260
Norfolk Naval Shipyard Industrial Hygienist
Shop 56 Shop 41
Marr
Callis Scott
961-4319 961-5330 961-5743
Charleston Naval Shipyard Shop 56 Materials Shop 56 Shop Stores
Mr. Schwertsberger Mr. McBride Ms. Lindsey
794-5501 794-5488 794-2713
Long Beach Naval Shipyard Shop 26 General Foreman
Mr. Vollrath
360-7797
* Commercial number if area code is given otherwise AUTOVON
502666
30
Shop 56 General Foreman
Mr. Webi
360-6406
Code 906 Safety Issue
Pipe Shop Shop Stores
Supervisor
Mr. Cauley
Mr. Davis Ms. Sharlean
360-683360-66836
360-6449 360-6896
Mare Island Naval Shipyard Shop 64 General Foreman Technical Supply
Code 260
Mr. McFadden Mr. Pollard Mr. Schmutz
253-2373
253-4402
253-2277
Puget Sound Naval Shipyard Pipe Shop Shop 56 General Foreman Shop 6 Concral Foroman
Mr. Nelson
Mr. Rogers
20- Brown
439-7849
439-7444
429-3221 429-3221
429-3221
Pearl Harbor Naval Shipyard Safety Office
Mr. Robert
808 471-3471
Naval Ship Engineering Center Philadelphia
Mr. Rogus Mr. Vapniarek
Mr. Burt
433-3587 433-3587 433-3914
Naval Ship Engineering Center Hyattsville
PHM Project Office
Mr. Bebar
301 436-1720
Navy Clothing and Textile Research Unit
D Fireman's Clothing
Mr. Andruk
Disposable Clothing
Mr. Seigfried
955-2173 955-2785
31
502667
rN
Specifications Disposable
Clothing
Planning
Navy Environmental Health Center
Mr. Loparto
Mr. Bailey Mr. Crawl
Contractors
Disposable Clothing Mars Manufacturing Co. Ness Disposables
Unitrex Products
Edmont
Durafab
Mr. Fisk Mr. Abell Mr. Beyer Mr. Welsh Ms. McCoy
955-2789
955-2785
989-3863
704 254-0741 704 274-2100 215 365-7400 1614 622-4311
817 045-8851
Respirators
31
Mine Safety Appliances
Sweat Paint Steven Industries
Farwest Paint Mfg Co.
Mr. Savin Mr. Leary
609 667-1361 202 785-2565
Mr. Steven
Mr. Sheehan
201 437-6501 206 762-1344
Insulation Clairemont
me. ROY
200 233-2034
502668
APPENDIX B
ITEM CONTROL RECOMMENDATIONS
a
mw mme o e
502669
502669 502669
0
4
ITEM CONTROL RECOMMENDATION
Oy Ts id mee OF IE Qe
+ ett.
8 athe
_
!
NOT IPO UM teram sending 1 banane
@) se@dmnarwe Of praperne
?
& real^oriatt
False (Acuee NAVSEC Code 1101
oman oD
time 8 duro riebent ef
er
Winer
Mr. A. Winer
s^tingof tata
ara
time l
Cs
ee
tne Wisherd
bind eonanesie4 a
10s
pe feat1s0 arvacedfi
Cede Veh
See
renee
Mr. J. Wisherd
sApanes Oceeenne Pata tt antA
pt ren wee Cot nt
aregamand of ane teme 1 mpasquc mpasquc mpampasqusc quc of catre ma
BICOWNIAGBICAOWNIAGA 0616
_s
T80N NG
LOCAL STUCK
.
FEDERAL FEDERAL STOCK
RECOMMENDATION FOR
Teaner v6 liquent
me 0 turie
SICOUMEROLO INTERFORT MANAGER 0530 M | STANDARD HAFT STOCK m 1 any
Protretive , High Lightweight NAME OF ITEM
Protretive Alanket sere a
omee
eo
hee
inari va repeat home , hilstary DESCRIPTION DESCRIPTION
far sem nems destribe in detall on 40 FORM
tures specification arguing arguing of procuremight reference
Temperature
Silicone
Rubber
Coated Asbestos
Free
166
using
Federal Dewrition Pattern it published Indicate
and
indicate
indicate
known sources of supply
hillstary federal or themelse
silica fabric 0.024 inch nominal thickness 18 ounces
Imous
llament amorphous coated both sides
with
silicone rubber compound
Dow Corning Silastic
per square vard
of 0.026 inch and a nominal weight of 22 ounces per
2351 to a nominal thickness
with STD and 1-24244 33 inches
square yard The material shall comply
vide nominal in 50 yard rolls Red in color
Manufacturer's Trade name REPRASIL
Item Code 100-48 Red
Manufacturer Fabricote Division of & Class Fabrics Co. Inc. 724 E. 60th Street . Los Angeles C. 2000
ALASON
1 biare opere a anded
FOR BECOMMENDATION
war plam akrete ha mbering them *Petd
#e and the ing on rock the some end recommanderson number of stai ka~ king at
Urgent requirement Breathing asbestos
to eliminate asbestos containing materials fibers is a serious health hazaro
at hi
STOCK DATA OF Un G0 BOG HO
INITIATING ACTIVITY FOR NEW ITEMS ITEMS AND TRANSFERS OR SYSTEM
( eutes beard on coou f cnout nt
ESTINATIONLABLY ESTINATIONLABLY BEQIMBE | PAST & MONTHS ISSUES = | Om MAND
Mite iNew ESTINATIONLABLY BEQIMBE
STOCKS FOR
ON ORDER
|
SUPERSENKU
ACCOUNT
AND WOUT
DISCONTINUED ITEMS ITEMS
PRICE
| WAIT OF 048
|
REFRASIL
100-48
15,000 yds
ISICUTING DITI~ i^kDITI~ i^kName bals and ra^r
(Synatere)
|
3.50 | vu 1
CATE
ACTION BY DUSANDA
LAOSYNIe Ort gus (Aces eed ined
[equerare)
33
DATE
562670 56270 562670 562670 562670
562670
Ay i
eee
. .6
ITEM CONTROL RECOMMENDATION
KAVSIM FOPM 210 210 511
TEM KAVSIM ee eeOETm
NOTE
FOL4 FOL4 in mendin } } to m^ma^o> f jurajame
bawiin
of contJORZO
WA
Oat Re Leone **
PROma PROma Leone
NAVSIC
Code
6101
6101
MT
rs
er
mee
NIIae 8
A.
-
Ts EWES 4670
discoustavamre of making making of come
reves ee
1 dangumand en Ax
awe ne
et
eee
Meme
6 Raced me ad Re
a
Winer
064
064
me
...
'
Y ape ere +
... nald...
...
fee
ta ag ee i ted eld y
ae
Ca umn) NL BUSAND^(
ON
D7CM vutde
1
Mr.
Mr.
. oc,
Wisherd Wisherd
Wisherd
ee eee ee :
DESCRIPTION DESCRIPTION TOI
seme
ca DESCRIPTION
FEDERAL DESCRIPTION PATTERN M3
" oa
DIAM DESCRIPTION '
(7) | DIADM IAM IN ATTACHEU
INVENTONY ALCOMMENCED ALCOMMENCED INVENTONY
:
NARIGIO
6,144
#1
Pry
Ser
eee
ary
o TRANSFER i FLMUANCE RECOMENDATION
FOR
SUPER
RECOMMENDATION 1) NEW ITEM
SLOUME
tw
ae
tS Grae
Protective Blanket High Temperature Silicom Silicom Silicom
NAME OF ITEM
DESCRIPTIOtt
For new turar's
Insert in cazabal lettera
dems describe in detall specification drawing or
on 00 FORM 148. using fo largi Description Pi^-are il
, ocurement ocurement reference number and ing DOVER Saulist oe
CAute
ae ee
..... HH
.... ae Fetes
yee
Continuous filament
fibrous glass
fabric
9,026
fach
nu,,12
6
Square yard coated both sides with silicone silicone kayin S2351 to a nominal thickness of 0.039 unch and rivomkinki yard The material shall comply with MIL STD 767 and 11LL nominal width in 50 yard rolls White in color
wert Ess
set,
i
Manufacturers Trade Name FABRICOTE
Item Code
1784 Cwhite!
Manufacturer Fabricote Division of Los Angeles CA YOQUI
& Clawn
Fabrik
t ae.
ooo
sth
tte ty,
if mats apper u karded wer plain sheria shM^ NHIS Poer d
Ht. 006 chor cag @@ b ves te ams BOE MPR srSe EIOR apmin orreumse ost!
BLASON FOR BECOMMENDATIOBNECOMMENDATION Urgent requirement
asbestos fibers is
to eliminate watemtom comtaginere vate bade.
1 serious health hazard
emt
-- news ener rns cmemrem
Fre
bbe.
-
-
FOR SUPERSEDED SUPERSEDED SUPERSEDED AND Dholak SHOE COED
ST^TEM OF INITIATING ACTIVITY FOR NEW ITEMS AND TRANSFERS TRANSFERS OR ST^ TST^ETEMM VLOCKS
1
26 STOCK DATA
gi gi resh^ preby na L LR ~ R~ N N
--
-~
-
teeat
8
4th
| PART MONTHS | Tw .../ se .../| FEM OR STOKE NO
ESTIMATED MEN1 N CEMENT CEMENT
LIS
Om NERD
cate
|
i t
i
FABRICOTE 1584
WHITE
80,000 van
1
LECUTING OFFICIAL OFFICIAL NE me talla and *
i
a
poe
4
pSyanseres
| 56.25
yd
\
|
.-
0418 , 0418
ACTIUM HY HLISANIJA HLISANIJA
=
LELENTING BUT I~ ia skaantd se alt
renee
4
meee mre
gmerered
DATE
502671
am &ers
OMS
ITEM CONTROL RECOMMENDATION ter 30-515
HAVSOP FORM
mee aw
30-515
NOTC @ um in frommending ) Wanism
l umfrommending af fromending frommending
we ow rs 6
^nurma 3 duco^-punchesof docking af demo of t^tlanir
pavenretes
naman:
3 wargames of am temi ( ) findet findet i un Cems
fae
otters
Winer &. ate.
-
D6A8 TE PROMI LANOVIJ
NAVSIC Code 6101
Mr. A. Winer
T
LOCAL 93658 a
Ws; detuned (ites SPCC SPCC
SPCC Code
Te
FAN IN ATTACHED (7)
5641
RECOMMENDATION
TRANSILA
FOR[ ...
DISCOOL
[)Q
TINUANCE FT}sttune
Mr J. Wisherd
FERGAAL DESCRIPIKIN FETTIKNAG
FEDERAL
| ENTORY ENTORY RECOMMENBLO
MANIGER US50 meTSIERbUesAe R&Y Ma Lifange
ghtweight High T TempeeramtureperatuTemrpereature ghtweighgt htweight
Protective BlaBlnankketet Blanket
High
AsAbsebsetsotsos Asbestos FrFereezez
ProtPreotcecttivieve NAME OF ITEIA
Linsert in copand hueres
reference DESCRIPTION
For new turer's
stems optcribe in detail specification drawing
ca 00 FORM 146 pidiurament pidiurament pidiurament reference
Pesoras Pesoras basrotation Pattarn in dubitened Indiesto using
number sig indiesta ^reansturchi at kundig
Mintaer
Federal
beli beli
yard "
amorphous ulica fabri , umewated,
Continuous filament
chee gba bbty
Hall maintain
18 ounces per square Chloride content shall
comply with MIL
Tu be 36
50 to 55 yard rolls Natural color
026 pes }
1 aD et Eraa ries,
ta
sae
ee vaste ae
inenes Maj wae 140
Manufacturers Trade Name REFRASIL
Manufacturer Materials Division of Street Cardena CA. 90249
Item Code 60-100-48
HITCO Armco Steel Corporation
1600 West
135th
KECOMMENDATION KECOMMENDATION Poor 1 of J te, 008 hoe mg soch she some and roomm 'the se of muring a wh
If more spare needed wie piem shorts sumberme sumberme them
asbestos containing materials materials
FEASON FOR
Urgent requirement to eliminate
health hazard
Breathing asbestos fibers in a serious
ANTRDANSbFaERrSd an af 2900) | E FOR SUPERSEDED ANG DISCONTINUED TEMS ;
OF INITIATING ACTIVITY FOR NEW ITEMS AND TRANSFERS ON SYSTEM STOCKS .
STOCK DATA
(
06d
| ON Ane
UN ONBLA
| ACCOUNT
UNIT PRICE
Nit of 13548
ESTIMAED | ESTIMATED TEARLY GLOUTGE FAST & MONIN
| | ; TIEM DE SIEK KA
NEXTS New dels emp
REFRASIL
100-48 ,
30,000 yds
CICUTING CICUTING OFF10164 OFF10164 Nathe luft and todel
6.58 |
yd |
|
*
*
(Stpansered
Dall
|
ACTION BY HUSANDA
LILLIAMS LILLIAMS OFF 8 Name and later
(Sqgeaters}
=
35
DATE pane
ee ee ee
502672 502672
502672 502672 502672
wwe. P VS