FILE NAME Manville JMA DATE 1976 Sept 30 DOC JMA293 DOCUMENT DESCRIPTION Report - Study of Asbestos Elimination Replacement and Personnel Protection - Prepared for the Naval Ship Engineering Center 102800240 102800240 30 September 1976 STUDY OF ASBESTOS ELIMINATION REPLACEMENT AND PERSONNEL PROTECTION Prepared for Naval Ship Engineering Mr. A. Winer Code 6101E Center Under NAVSEC Contract N00024-76 Task 6101-30 By Designers & Planners Inc. 3700 East West Highway 106 Hyattsville Maryland 20782 D Task 4476/50 502633 502633 , woul TABLE OF CONTENTS Section Page 1 1.0 Introduction l 1.1 Scope 1 1.2 Approach 3 2.0 Results 3 2.1 Background 4 2.2 Protective Clothing 6 2.2.1 Coveralls 6 2.2.2 Shoe Coverings 7 2.2.3 Gloves 7 2.2.4 Hoods 8 2.3 Respirators 8 2.3.1 General 8 2.3.2 OSHA Requirements 9 2.3.3 NIOSH Requirements 10 2.3.4 Navy Requirements 10 2.3.5 Activities Involved 2.3.6 Identification of Approved Respirators 11 13 2.4 Welders Blanket 14 2.5 Asbestos Millboard 2.5.1 Kaowool M Board and Fiberfrax llot Board 14 14 2.5.2 Millboard Used in Boilers 15 2.5.3 Joiner Bulkheads PHM 16 2.5.4 Welders Booths 17 2.6 Pipe Hanger Liners 17 2.6.1 Present Requirements 19 2.6.2 Status of Liner Program T 502634 502634 502634 = y gine Rr ee >) TABLE OF CONTENTS Cont'd ' Section 2.6.3 Resulta 2.7 Measurement Program 2.8 Miscellaneous Items 2.8.1 Fireman's Clothing 2.8.2 Asbestos Pump Vanes 2.8.3 Machinery Space Escape Trunks 2.8.4 Anti Sweat Paints 3.0 Recommendations 3.1 General 3.2 Insulation color coding 3.3 Technical Manual Revision 3.4 Respirator Air Supplies 3.5 Disposable Clothing 3.6 Pipe Hanger Liners 3.7 Millboard APPENDIX A - Facilities and Agencies Consulted APPENDIX B - Item Control Recommendations o est ii ; X INTRODUCTION 1.1 Scope Inc. This report has been prepared by Designers and Planners D in response to NAVSEC Task 6101-30 under contract 024-76- 4451. The task concerns engineering studies of asbestos replace- ment and personnel protection in Naval shipboard applications Specifically the following subtasks were identified as part of this task a Consultation with the Navy Environmental Health Center with reference to equipment and protective clothing to be used during asbestos out selection of pass criteria for operations on asbestos containing materials and examination of the usefulness of electron microscopy Preparation of Item Control Recommendations for entering new items into the Supply System Determination of substitutes for asbestos millboard Provision of liaison with NAVSECPHILADIV on tests of asbestos substitute materials Provision of support and liaison with NAVSECPHILADIV relative to substitutes for asbestos pipe hanger liners Approach In order to accomplish the task several actions were taken based largely upon the knowledge and contacts made during the preceding studies carried out under NAVSEC Task 6101-22 Those actions included o Consultation with each of the Naval Shipyards on the status protective clothing pipe hanger liners and the use of asbestos millboard the status of pipe hanger liner substitutes and test results and asbestos millboard substitutes o Consultation with vendors of protective clothing respirators and insulation oO Consultation with NAVENVIRHLTHCEN personnel on the asbestos fail criteria measurement program and selection of materials Results of the study are discussed in Section 2 of this report which is organized as follows Protective clothing Respirators Supplied Welders blankets Millboard Pipe hanger liners Measurement Program Miscellaneous Items Recommendations are made in Section 3 of this report 502637 502637 04 ses On 2.0 RESULTS 2.1 Background ~ The U.S Navy in response to National safety and health requirements concerning asbestos has instituted procedures designed to insure reduced personnel exposure to this hazard These procedures include use of safety equipment ventilation and improved asbestos removal procedures Concurrent efforts have been initiated to define suitable replacement materials for asbestos containing products OPNAVINST 6260.1 of 9 April 1974 specified limits of ex- posure of Naval personnel to asbestos The Chief Bureau of Medicine and Surgery was assigned technical responsibility for evaluating asbestos exposures The Chief of Naval Material was directed to provide technical assistance to define appropriate industrial hygiene controls and develop remedial projects NAVSEA Instruction 5100.2 24 October 1975 established NAVSEA policy on the elimination of asbestos in ship construction and maintenance and directed actions to further reduce asbestos exposure The following specific policy items were addressed d Asbestos and materials containing asbestos shall not be used in the construction overhaul repair and mainte- nance of naval vessels nor shall such materials be used in any facility or operational application where suitable alternate materials have been designated llowever in locations where asbestos materials are presently installed out operations shall not be performed for the sole purpose of oliminating asbestos 502638 b This instruction applies to all unbestos containing materials but the implementation details are currently available for thermal insulation only As additional substiture materials are develoned appropriate speci- fication and instruction revisions shall be made for implementation of this policy C. Personnel working with asbestos shall be provided with and be required to use protection and safeguards in accordance with OPNAVINST 6260.1 Chapter 635 of the Naval Ships Technical Manual NSTM was revised 15 April 1976 to eliminate asbestos containing insula- tion bringing it into correspondence with MIL and related specifications for asbestos free insulation Appendix A of Chapter 635 provides safety instructions for insulation workers Under the title of Asbestos Replacement Protection Program tasks were assigned in support of OPNAVINST 6260.1 and NAVSEA INST 5100.2 Subtasks were assigned to NAVSECPHILADIV for tests of asbestos substitutes to NAVENVIFHLTHCEN for measurements of asbestos contamination and program recommendations and to P as e described in Section 1.1 roy 2.2 Protective Clothing Appendix A of Chapter 635 of the NSTM states A.2.2 a Asbestos and fibrous glass handlers disposable coveralls and clothing in accordance with 29133 Navy providing whole body head hand and foot coverings for use by personnel exposed to airborne concentrates of asbestos fibers shall be provided Cloth hoods such as painters hoods shall be worn for head covering Disposable plastic gloves , 502639 rg & aA eo shall be worn to protect hands Cloth gloves may be worn inside the plastic gloves for but shall not be used alone Sleeven comfort hall ha made secure at the wrist by use of flaps provided or by use of masking tape Stock numbers for coveralls by size are Small Small Medium Large Large Large NSN NSN NSN NSN NSN NSN 8415-00-601-0792 8415-00-601-0793 8415-00-601-0793 8415-00-601-0794 8415-00-601-0797 8415-00-601-0801 8415-00-601-0802 The Naval Shipyards were surveyed to find how acceptable were the coveralls listed above and to find out what shoe coverings and gloves were being used and their acceptability It was painfully clear that the instructions contained in the NSTM have not filtered down to the shop level as of 15 September 1976. At least four of the lagging shops in the eight yards had not seen the new Chapter 635 of the NSTM and were not aware of the clothing requirements The Navy Clothing and Textile Research Unit Natick Massachusetts is the activity responsible for the development of clothing items and related specifications The Clothing and Textile Unit Defense Supply Agency Philadelphia Pennsylvania is the control point The information contained in this protective clothing section of this report is current as of 15 September 1976 Disposable protective clothing is widely available in plastic materials Polyolefin TYVEK is duPonts trade name for spun bonded olefin polyethylene polyvinylchloride and rayon are a few of those materials While flame resistance varieas ll melt when ex- posed to flame and under some conditions may cause serious burns S 502640 | 4 2.2.1 Coveralls A minated cellulogic material is calluacal ua Oe, OT eee from which the 29133 coveralls are made The specification requires that the material not melt or drip in the re flame One trade name for the cellulosic material is KAYCEL >. test Three users of the coveralls in the stock system MIL 29133 report general satisfaction with the items Every user reported that they tear easily when snagged on sharp objects Two users reported that the Large size is not large enough for some of their workers One previous user reported that the stiching is inadequate and is now using double stitched KAYCEL coveralls obtained on local purchase One previous user found that the clothing did not breathe well enough and tended to creep and bind in the shoulder and crotch As a result that yard is using a launderable 60/40 cotton dacron blend coverall Several iterations of laundering procedure done under contract were required to get the residual asbestos fiber content down The problem was primarily in pocket areas pockets are being eliminated The remaining three yards are using local purchase disposable coveralls made of TYVEK 2.2.2 Shoe Coverings Two yards are using the shoe covering bootie in insula- tion work that has been put into the system for nuclear workers NSN 8430-00-890-2079 These booties meet 82240 and are 562641 562641 562641 6 5625626 641 54 626411562641 vinyl chloride film Type , cluss 2 of 375 One of the two yards is ordering the bootic to 82240 except for white or color the stock numbered item is yellow green Two other yards are using plastic booties bought under local purchase Four are not using any shoe covering vs a taping plastic to coveralls 2.2.3 Gloves Three yards are using cotton gloves NSN 8415-00-268-8330 . One yard is using a leather drivers glove vinyl coated cloth glove Three yards are One yard is using a using disposable plastic gloves of differing types two yard for all applications are using yard only surgical gloves one when handling cement which irritates skin 2.2.4 Hoods ae Two yards are not using hoods Two are fabricating ee hoods locally from cotton cloth Two are using a disposable hood made of TYVEK One is using a hood which is part of an approved fed respirator systems are used NIOSH approval is for When fed respirators which include specific hoods respirator systems of elements of the respirator system for example Substitution using one hood in place of another technically invalidates the approval For see Section 2.3 additional information on respirator systems 502642 502642 502642 502642 502642 502642 -) 2.3 Respirators 2.3.1 General Basic standards are set by the Occupational Health and Safety & Health Administration OSHA The National Institute for uccupational Safety and Health NI05m acts in an advisory capacity to OSHA and among other duties tests and certifies items of safety equipment for workers such as respirators NIOSH prepares and publishes lists of certified products The Navy by means of OPNAVINST 6206.1 and NAVSEAINST 5100.2 promulgated requirements for respiratory protection and other protective devices for workers engaged in asbestos work . . In additiothne Naval Ship Technical Manual Chapter 635 Appendix A deals with the required protective devices 2.3.2 OSHA Requirements These are found in CFR Title 29 Chapter XVII Section 1910.93 iii delineates three different classes of respirators depending on the expected concentration of airborne asbestos The type of respirators required vs the limiting air- . borne asbestos concentrations are given below Limit leiers either to the ceiling or to the eight hour time weighted average TWA Less than 10x limit 10 - 100 limit over 100x limit Type respirator A B 0 502643 502643 502643 502643 yD The current time weighted average limit effective 1 July 1976 is 2 asbestos fibers per cubic centimeter of air with a ceiling ex- posure extent limit of 10 of exposure tibers cannot per cubic centimeters of air Since be predicted well it must be 427 sumed the that a shipboard worker engaged in asbestoasbs estos insulation removal would require a Type C respirator are defined as a supplied continuous Type C respirators demand respirator which consists of a source flow or pressure of respirable breathing air control valve an orifice a a hose a detachable coupling a demand valve or pressure demand attaching valve an arrangement for the hose to the wearer and a facepiece hood or helmet Regulations for approval of respira- tors are defined in 30 CFR Part 11 Approvals under these regu- lations are issued jointly by the U.S. Department of the Interior Mining Enforcement and Safety Administration MESA and NIOSH Additional requirements relating to the air supply are found in OSHA regulation 1910.134 which requires tem- perature monitoring of the air The quality of air supply for human breathing is defined in the Compressed Gas Association Commodity Specification 7.1- 91966 Class D 2.3.3 NIOSH Requirements NIOSH under authorization of the Coal Mine Health and Safety Act of 1969 and the Occupational Safety and Health Act of 1970 provides a testing approval and cortification program and develops performance regulations tests and certifies 502644502644 protective devices and verifies the quality of manufacture of these devices Supplied respirators which are certified by NIOSH are given by manufacturer and model number in Appendix G of the Dai report on Task 6101-22 dated 30 June 1976. It must be omphasized here that these certifications are for complete Type C supplied air respirator systems and any interchange of parts from different vendors would render the NIOSH certification invalid 2.3.4 Navy Requirements General The requirements for respiratory protection for personnel engaged in asbestos work are given in OPNAVINST 6260.1 and NAVSEA INST 5100.2 In addition Appendix A to Naval Ships Technical Manual Chapter 635 NAVSEA 635-0000 calls out bafety - requirements for insulation workers This chapter also referen- ces Chapter 9880 Section II of NSTM Damage Control Practical Damage Control In general these three documents follow the OSHA and NIOSH requirements but to be in strict accordance Chapter 635 requires minor changes These are given in Section III Recommendations of this report 235 Activities Involved Within the Department of Defense the Defense Supply Agency unit at Richmond Va controls Defense General Supplies including FSC 4240 respirators The Naval Construction Battalion Port 502645 10 & Hueneme California prepares specifications for respirators Edgewood Arsenal , Maryland tests respirators for the Military services GGG is the general specification for inspirators and respirator assemblies Slash of respirators Supplied air sheets specify individual types respirators are covered in the following shash sheets GGG GGG GGG Respirator Assemblies Air Line Facepiece Supplied Air with Respirator Assemblies Air Line Helmet Supplied Air Respirator Assemblies Air Line with Disposable Hood Supplied Air GGG is a supplied air respirator for abrasive blasting operations and 10 and 11 have purifying units The other respirators protect against gases and dusts In addition to the NIOSH approval requirement under 30 CFR Part 11 contain requirements for such aspects as lens the specifications quality marking etc. GGG is a specification for disposable filter masks 2.3.6 Identification of Approved Respirators An attempt was made to correlate the OSHA NIOSH and Navy requirements for respirators with the applicable federal specifications and standards and to determine which approved suppliedair respirators had National Stock Numbers NSN and could be assumed to be in the federal supply system To this end various codes in NAVSEC and NAVSEA were queried 11 hy Supply as well as the Defense Agency DSA Item Identification ' Group in Richmond Va No correlation could be established Therefore two pilnufacturers pilnufacturers pilnufacturers of this equipment vers consulted and no correlation could be established It does not air supplied respirators of an approved type are in appear that the federal stock system 502647 2.4 Welders Welders * -7t rn Red SuUeeerut~ completely satisfactory are While While s of wateriale Leen satisfactory 4 blankets cloths as blankets of number materialt materialt are are rnese gintroduce available available for stock materials Item these system interim materials NAVSUP system Recommendations Recommendations prepared the follcwing Recommendations Form Form 87 prepared ~ Appendix B silica fabric (REFRASIL . An ounce amorphous 1. - UC 100-48 silica fabric (REFRASTL 2. . A ounce amorphous coated with silicone yupber silica fabric 3. . amorphous C 100-48 } ito to ounces REFRASIL rubber (to fabric coated with silicone a. A fibrous glass 32 ounces FABRICOTE 1584 tee ee peony re eteGrmg we swe ere ate en ee qe ee yocuRet cette. OD ak aad erQ .OUTA * AMO OE. epee VES ? ** ******** meet eter y sett Coreen fs we eS) RETAKE TARGET - 2.5 Asbestos Millboard is intended for interior use to serve Asbestos millboard fire surface flame spread as temporary protection against neated gas and against neids and cor- liquid or solid objects rosive liquids It is available in 3/16 1/4 3/8 and 1/2 sheet inch form with thicknesses of 1/6 1/8 and widths of 42 inches and lengths of 48 or 96 inches 351E 2.5.1 Kaowool M Board and Fiberfrax Hot Board of Kaowool NAVSECPHILADIV investigated the acceptability M board and Fiberfrax cate high temperature Hot Board as a substitute for calcium insulation block 2819F This silicheck insulation block was sometimes undertaken because 1 thick was are that M board and in short supply Preliminary reports e costs are consi- substitutes however Hot Board are acceptable erate in thicknesses less and they are not manufactured Cerably higher silicate is inch are that the " calcium Indications than 1/2 ~rpne and substitution should not be necessary no longer in short supply 2.5.2 Hillboard Used in Boilers NSTM 9510 Boilers defines methods for constructing boiler furnace docks rear and sidewall is not called for and materials linings The use of millboard other than those listed under be used only in an emergency NSTM 9510.116 are to 502649 14 one inch thickness of NSTM 9510 calls for a insulating block next to the stoc ~" ange te 12 been rape 0 OTT Tae piler furnace plans call for 1-1 or 1-1 inch of insulating block next to the boiler casing Insulating block under 1-2819F of 1 1-1 2 2-1 3 3-1 or is supplied in thickness millboard is sometimes used to 4 inches Therefore asbestos block next to the make up the required thickness of insulating millboard it was As an alternative to asbestos boiler casing sometimes been used { that a layer of mineral wool has reported in the Naval shipyard use of An example of the variance Philadelphia and Norfolk millboard can be drawn between asbestos Naval Shipyard Shop 41 Boiler Naval Shipyards Philadelphia millboard and had no need for stated they did not use asbestos Naval Shipyard Shop 41 reported that a substitute at Norfolk used asbestos millboard in 1/8 or 1/4 inch they occasionally thicknesses to build up the required thickness of insulation was the recent use next to the boiler casings An example given the USS America CV66 of asbestos millboard in the boilers on 2.5.3 Joiner Bulkheads PH 1 bulkheads containing material was used as a bulkhead An asbestos on and as some joiner liner in the engine compartment as asbestos millboard but as the PHM It was not identified as asbestos containing material for the The specifications that asbestos free material state follow on PHM class vessels shall be used in its construc- tion 502650 No retrofit is presently scheduled to remove the asbestos containing material llowever when an ROH is scheduled replacement will be considered 2.5.4 Welders Booths No instances were found where asbestos millboard was being used as dividers for welders booths These booths are normally partitioned using REFRASIL or one of the many other fibrous glass cloths available 16 502651 2.6 Pipe Hanger Liners In some applications line hangers which eunnost reduces heat transmission asbestos tape or cloth has 7% niping runs aboard Some Naval shipyards have been used to mre 1 been sub- stituting fibrous glass tape in those applications D Was 50- quested to review the acceptability of the substitution 2.6.1 Present Requirements General Specifications for Ships Section 505 For services below 200 degrees F. pipe hangers shall be lined with a liner material to prevent the pipe clamp and metal to metal contact between are of dissimilar pipe when the pipe clamp and pipe matesreiravlisces from 200 degrees F up to 650 degrees F to For shall be lined with a liner material pipe hangers contact between the pipe clamp prevent metal and the pipe For services above 650 degrees F. mini- mun contact hangers shall be used the For all hot services the hanger rod between and resilient mount shall be of sufficient pipe clamp from being subjected to length to preclude mounts F. temperatures in excess of 140 liner materials degrees shall be in accordance shall not con- Applicable with Table 6. Asbestos liner materials or reinforcing wires tain any metallic particles TABLE 6 PIPE HANGER LINER MATERIAL Temp degrees F Up to 180 Over 180 to 450 Over 450 to 650 Liner material & Form Synthetic rubber channel block type or sheet rubber cemented to hanger clamp Silicone rubber , Asbestos Felt Tape Applicable specification 6855 class II 60 durometer 765 class II 60 durometer 1784 466 form IV or 1782 class I grade MA or MA 17 p- _ 4 . eh 7eS TABLE 5 CONTINUED Zlotn Sheet 466 form [, traue AA JE Reinforced r 1763 class , grade M or AMA ; HH Standard Drawings Hangers pipe for surface ships Dwg # 810-1385781 For sound and vibration reduction the pipe clamp shall be lined with 1/4 in thick rubber Liner be in accordance with 6855 class 2 60 to to 125 durometer for fluid temperatures up For piping with fluid temperatures above 125 a in accordance with SS- liner of 1/8 in asbestos between the 466 type IV shall be provided ' pipe and clamp for submarines Dwg # 5000-54823-1385782 5000-54823-1385782 Hangers pipe exceeds 180 the following wmhaetreeriaplispinsghaltlembpeerautsuerde in lieu of rubber 6855 specified in the list of materials A B C D Silicon rubber 765 Cirss II grade 60 Max 550 or Asbestos felt 20077 or Asbestos tape 4117 Cl 1 metallic XX or XXI Grade AA AAA or AAAA wire reinforcing cloth 466 Navyships of a style containing not less than 90 percent asbestos 502633 50263350263 502633 18 2.6.2 Status of Liner Program NAVSEC Philadelphia had previously been assigned a task to determine through shop laboratory test the acceptability of fibrous glass pipe hanger liners This is an ongoing task which has not been completed as of the date of this report In conjunction with this an attempt was made by both NAVSECPHILADIV and D to determine if the Naval Shipyards had used fibrous glass pipe hanger liners aboard ship in the - past and if so had the application been satisfactory Personnel in the Design and Production Departments of the Naval Shipyards were asked to identify ships in which fibrous glass liners had been installed The following ships were tentatively identified as having had fibrous glass pipa hanger liners installed SSM 596 SSN 618 Mare Island Mare Island SSN 620 Portsmouth SSN 635 Portsmouth l, SSN 646 Portsmouth SBN 664 Portsmouth SBN 673 Portsmouth 880 674 Portsmouth 88N 676 _ Portsmouth PF 1072 FF 1078 Charleston Charleston 502654 19 Three fibrous glass products have been identified being used by the shipyards as pipe hanger liner material ey te ni Portsmouth Portsmouth Charleston ALFEA 7 Claremont 16 NSN * 2315-00-267-1362 8315-00-768315-700-7-67-11 6 26) It was the intent of this task to identify and visit several ships which had had fibrous glass pipe hanger linera installed and the liners would then be examined to see how well they had withstood counding vibration wetness etc. 2.6.3 Repuls Since shipyard personnel could not positively identif on which piping system or in which compartments the -.necss been installed no ship visits were made Without positive location of fibrous glass liners it would be costly and difficult to examine their performance cause in general the hangers and liners are enclosed by the insulation covering the pipes To inspect the liner the inst tion must be removed and subsequently it must be replaced If inspection of liners in service revealed no damage it would not guarantee that fibrous glass would be an acceptal substitute in all applications for long term use because the conditions of use would not be known On the other hand if spection revealed damaged liners it could lead to a general prohibition of use ') Three fibrous glass products have been identified as * being used by the shipyards as pipe hanger liner material Mare Island ALPHA Catalog 3201 Portsmouth Charleston Claremont 19T25 NSN 8315-00-267-16382315-00-267-1632 NSN 2315-00-267-16332315-00-267-1633 It was the intent of this task to identify and visit several ships which had had fibrous glass pipe hanger linera installed and the liners would then be examined to see how vibration wetness etc. well they had withstood pounding a a a Fs 2.6.3 Results Since shipyard personnel could not positively identify the liners had on which piping system or in which compartments been installed no ship visits were made Without positive location of fibrous glass liners it would be costly and difficult to examine their performance be- cause in general the hangers and liners are enclosed insulation covering the pipes To inspect the liner by the the insula- tion must be removed and subsequently it must be replaced of liners in service revealed no damage If inspection acceptable it wouldnot guarantee that fibrous glass would be an substitute in all applications for long term use because the conditions of use spection revealed be would not known damaged liners it On the other could lead to hand if in- a general prohibition of use 502635 G Therefore it is believed that inspection of existing fibrous glass liners would have limited value If the two pipe hanger liner drawings and the NSTM requirements are taken together fibrous glass liners uss required only in the range 550 to 650 One option is to extend the use of limited contact liners downward to include the range 550 to 650 650 to eliminate the use of asbestos and the need for another substitute 2.7 Measurement Program The Navy Environmental Health Center has been funded to conduct an asbestos measurement program and to make recommendations for changes to asbestos handling procedures and equipment Discussions were held with the Center to transmit in advance of this report our findings and what information we had gained since report on Task 6101-22 21 502656 502656 2.8 Miscellaneous Items of the study a number of applications of asbestos In the course were uncovered or revi flacussion flacussion of coun ve wildl 2 ovr follows 2.8.1 Fireman's Clothing P was asked to review the status of fireman's clothing As with the disposable clothing the Navy Clothing and Tex- tile Research Unit is responsible for fireman's clothing At an present fireman's clothing is made from aramid nylon fabric 29143 backed aluminized asbestos up with a quilted lining While the Clothing and Textile Research Unit is aware of the as- bestos problem they are not funded in PY 1977 to develop a replace- ment for the asbestos cloth 2.8.2 Asbestos Pump Vanes The Auxiliary Equipment Branch NAVSEC 6153D has approved the substitution of Ryton Polyphelene Sulfide plus glass and Teflon filler for the previously used Melamine Asbestos in vane Blackmer Pump Division of the Dover pumps supplied to the Navy by Corporation 2.8.3 Machinery Space Escape Trunks To minimize heat transfer to ladders in machinery space trunks the present design uses asbestos insulating pads escape between the ladder and the bulkhead In proposing redesigns which meet the intent of the General Specifications for Ships one of the P is the use of non asbestos insulation criteria being assumed by in the application 22 502657 & 2.8.4 Anti Sweat Paints & was asked to investigate sweat paints of two types 1. Coating Compound Paint Antisweat 492C 2 Paint Retardant 15144 plus Vermiculite 15196 The coating compound FSC 8010 is controlled by the Federal Supply except Service 492C specifies the components of the for an extender which is nominally 90 by weight of paint the pigment 27 of suppliers One antimony oxide the product weight There are two approved supplier states that the extender is entirely The other supplier states the extender is 20 diatomaceous silica and 71 asbestos by weight of solids The fire retardant paint contains no asbestos The speci- fication for vermiculite 15196 has been superseded by 585 Insulation Thermal Vermiculite which calls out ASTM Standard C516 for Vermiculite No mention is made of asbestos 3.0 RECOMMENDATIONS 3.1 General In the course of this studen a number of 77 ie Discussion of those recommendations is presented below 3.2 Insulation Color Coding The bulk of the insulation in Navy ships is block or pre- formed insulation Use of such insulation containing asbestos is but it is difficult to distinguish between presently prohibited containing and asbestos forms of block and preformed insulation during out It is relatively much easier to dis- tinguish between asbestos cloth and fibrous glass cloth tween other forms of asbestos containing insulation and and the besub- stitutes It is suggested that insulation manufacturers be re- quested to color code the insulation for all users Manufacturers have objected to the problems involved in setting up a separate line for Navy products In that way if in future rip noncoded insulation were encountered personnel would at least be alerted to the danger color asbestos insulation installed up to the change over point would continue to be treated as though it were containing At present there is no way of knowing which material is being torn and there appears to that the situation will be resolved at any point in be no assurance the future 3.3 Technical Manual Revision It through is apparent Chapter 635 that the promulgation of safety requirements of the Naval Ships Technical Manual is not 24 502659 rapid enough to insure compliance in a time hanner Also view of the unsettled status of protective dicthing and respirators in terms of what is both safe and acceptable clear identification it is recommended that be revised to contain only policy statements mentation of those policy statements through and in terms of the Technical Manual and that the implerecommendations for use of specific items of equipment or clothing be made directly to the expected users For example 1 Change Appendix A to NSTM Chapter 635 relating to respira- . tory protection as follows a Paragraph 2.b.l change type A class II to read NIOSH Certified Type C supplied air respirators b Delete paragraphs 2.b. & 2.b. for two reasons is not NIOSH one the specified breathing apparatus certified for this application and also these respirators are emergency equipment stowed in the damage control locker and should be so reserved 2 Do not assign NSN's to supplied respirators Approved respirators are available from industry in a timely fashion via purchase wavrs nuthoriznuethordized Federal Supply Schedule Catalogs by manufacturers item numbers The respirators are under FSC Group 2390 New Item Introductory 4240 Example Item Schedule Contract Number 002-31030 Minnesota Mining & Manufacturing Co. St. Paul Minn 55101 Dept. 220-7w 502650 However one problem is that fleet activities do not normally have access to such documents For those activities data must be provided so that they can order suitable protective equipment The NSTM snoula not be relied upon to provide timely dissemination This recommendation is made in light of the large number of repair and replacement parts required for each model respira- of various items of vendors equiptor and the fact that mixing would invalidate the NIOSH Certifi- ment is not only difficult but cation 3.4 Respirator Air Supplies Investigate the compatibility of these respirators with the applicable Of particular interest are the safety existing air supplies for USHA and NIOSH requirements and standby devices per OSHA regulation 1910.134 3.5 Disposable Clothing 3.5 As discussed above in spite of the instructions contained in Chapter 635 of the NSTM lugging shops in the shipyards are using a wide variety of clothing items including n some cases no protection It is also clear that there is some dissatisfaction with the disposable coveralls now in the stock system The following are recommended 1 Request the Navy clothing and Textile Research Unit to revise the existing specifications for disposable coveralls 29132 for the material and MIL 29133 for the coverall to increase tear resistance revise the stiching add additional sizes and and requirements to minimize creep and bunching 2 Since Recommendation 1 is expected to require a year to two years to accomplish as an interim solution permit the yards to use local purchase of cover- alls 3 Review the fire safety requirements of the coveralls and if found to be a hazard prohibit the use of plastic disposable clothing such as TYVEK and vinyl 4. Request the Navy Environmental Health Center to determine whether KAYCEL clothing is adequate to protect against asbestos dust 27 5 Direct the Naval Shipyards to use full protective clothing and supplied air respirators as described in Appendix A of NSTM Chapter 635 by more rapid and direct means than the NSTM 6 Revise Chapter 635 of the NSTM to include the ratio- nale for use of Class C supplied respirators i.e. that 100 X the 8 hour time weighted average limit or ceiling limit is expected to be exceeded during any asbestos out 502663 3.6 Pipe Hanger Liners 1 Continue the effort to identify locations on the ships fibrous glass pipe hanger liners were installed If listed where such locations can be identified visit those ships to determine acceptability 2. Continue laboratory tests being conducted by NAVSEC- PHILADIV that fibrous glass has not 3. Inform all Naval Shipyards been approved as an acceptable material for and to use General Specifications for Ships pipe hanger liners and Naval Standard Drawings as reference for approved materials 4. Select a ship now in overhaul and install alternative locations with the intent of liner materials in identified examining the liners after say a years operating service revise the General Specification and 5. Alternatively to delete reference to asbestos pipe hanger drawings and to require the use of silicone rubber 765 materials up to of 550 and minimum contact pipe hangers above temperatures that temperature There are differences in application temper- atures in the drawings and the specifications see 2.6.1 3.7 Millboard be found for millboard for which Since no application can it is recommended that its use be prohibited it is required 502664 o APPENDIX A ~1 FACILITIES AND AGENCIES CONSULTED Fodoral Supply Service Paints Mr. Baldeman Defense Supply Agency Richmond Va Item Identification Oakley Engineering Mr. Woods 212 212 557-5357 695-4410 695-3664 U.S. Navy Portsmouth Naval Shipyard Shop 56 Superintendent Shop 56 Planner Code 260.12 Mr. Parent Mr. Patch Legere 604-2364 684-2350 684-2293 Philadelphia Naval Shipyard Shop 56 Asst Supt Code 262 Seas Shop 41 Sweeney Wolfe Hilton 443-3320 433-3387 433-2260 Norfolk Naval Shipyard Industrial Hygienist Shop 56 Shop 41 Marr Callis Scott 961-4319 961-5330 961-5743 Charleston Naval Shipyard Shop 56 Materials Shop 56 Shop Stores Mr. Schwertsberger Mr. McBride Ms. Lindsey 794-5501 794-5488 794-2713 Long Beach Naval Shipyard Shop 26 General Foreman Mr. Vollrath 360-7797 * Commercial number if area code is given otherwise AUTOVON 502666 30 Shop 56 General Foreman Mr. Webi 360-6406 Code 906 Safety Issue Pipe Shop Shop Stores Supervisor Mr. Cauley Mr. Davis Ms. Sharlean 360-683360-66836 360-6449 360-6896 Mare Island Naval Shipyard Shop 64 General Foreman Technical Supply Code 260 Mr. McFadden Mr. Pollard Mr. Schmutz 253-2373 253-4402 253-2277 Puget Sound Naval Shipyard Pipe Shop Shop 56 General Foreman Shop 6 Concral Foroman Mr. Nelson Mr. Rogers 20- Brown 439-7849 439-7444 429-3221 429-3221 429-3221 Pearl Harbor Naval Shipyard Safety Office Mr. Robert 808 471-3471 Naval Ship Engineering Center Philadelphia Mr. Rogus Mr. Vapniarek Mr. Burt 433-3587 433-3587 433-3914 Naval Ship Engineering Center Hyattsville PHM Project Office Mr. Bebar 301 436-1720 Navy Clothing and Textile Research Unit D Fireman's Clothing Mr. Andruk Disposable Clothing Mr. Seigfried 955-2173 955-2785 31 502667 rN Specifications Disposable Clothing Planning Navy Environmental Health Center Mr. Loparto Mr. Bailey Mr. Crawl Contractors Disposable Clothing Mars Manufacturing Co. Ness Disposables Unitrex Products Edmont Durafab Mr. Fisk Mr. Abell Mr. Beyer Mr. Welsh Ms. McCoy 955-2789 955-2785 989-3863 704 254-0741 704 274-2100 215 365-7400 1614 622-4311 817 045-8851 Respirators 31 Mine Safety Appliances Sweat Paint Steven Industries Farwest Paint Mfg Co. Mr. Savin Mr. Leary 609 667-1361 202 785-2565 Mr. Steven Mr. Sheehan 201 437-6501 206 762-1344 Insulation Clairemont me. ROY 200 233-2034 502668 APPENDIX B ITEM CONTROL RECOMMENDATIONS a mw mme o e 502669 502669 502669 0 4 ITEM CONTROL RECOMMENDATION Oy Ts id mee OF IE Qe + ett. 8 athe _ ! NOT IPO UM teram sending 1 banane @) se@dmnarwe Of praperne ? & real^oriatt False (Acuee NAVSEC Code 1101 oman oD time 8 duro riebent ef er Winer Mr. A. Winer s^tingof tata ara time l Cs ee tne Wisherd bind eonanesie4 a 10s pe feat1s0 arvacedfi Cede Veh See renee Mr. J. Wisherd sApanes Oceeenne Pata tt antA pt ren wee Cot nt aregamand of ane teme 1 mpasquc mpasquc mpampasqusc quc of catre ma BICOWNIAGBICAOWNIAGA 0616 _s T80N NG LOCAL STUCK . FEDERAL FEDERAL STOCK RECOMMENDATION FOR Teaner v6 liquent me 0 turie SICOUMEROLO INTERFORT MANAGER 0530 M | STANDARD HAFT STOCK m 1 any Protretive , High Lightweight NAME OF ITEM Protretive Alanket sere a omee eo hee inari va repeat home , hilstary DESCRIPTION DESCRIPTION far sem nems destribe in detall on 40 FORM tures specification arguing arguing of procuremight reference Temperature Silicone Rubber Coated Asbestos Free 166 using Federal Dewrition Pattern it published Indicate and indicate indicate known sources of supply hillstary federal or themelse silica fabric 0.024 inch nominal thickness 18 ounces Imous llament amorphous coated both sides with silicone rubber compound Dow Corning Silastic per square vard of 0.026 inch and a nominal weight of 22 ounces per 2351 to a nominal thickness with STD and 1-24244 33 inches square yard The material shall comply vide nominal in 50 yard rolls Red in color Manufacturer's Trade name REPRASIL Item Code 100-48 Red Manufacturer Fabricote Division of & Class Fabrics Co. Inc. 724 E. 60th Street . Los Angeles C. 2000 ALASON 1 biare opere a anded FOR BECOMMENDATION war plam akrete ha mbering them *Petd #e and the ing on rock the some end recommanderson number of stai ka~ king at Urgent requirement Breathing asbestos to eliminate asbestos containing materials fibers is a serious health hazaro at hi STOCK DATA OF Un G0 BOG HO INITIATING ACTIVITY FOR NEW ITEMS ITEMS AND TRANSFERS OR SYSTEM ( eutes beard on coou f cnout nt ESTINATIONLABLY ESTINATIONLABLY BEQIMBE | PAST & MONTHS ISSUES = | Om MAND Mite iNew ESTINATIONLABLY BEQIMBE STOCKS FOR ON ORDER | SUPERSENKU ACCOUNT AND WOUT DISCONTINUED ITEMS ITEMS PRICE | WAIT OF 048 | REFRASIL 100-48 15,000 yds ISICUTING DITI~ i^kDITI~ i^kName bals and ra^r (Synatere) | 3.50 | vu 1 CATE ACTION BY DUSANDA LAOSYNIe Ort gus (Aces eed ined [equerare) 33 DATE 562670 56270 562670 562670 562670 562670 Ay i eee . .6 ITEM CONTROL RECOMMENDATION KAVSIM FOPM 210 210 511 TEM KAVSIM ee eeOETm NOTE FOL4 FOL4 in mendin } } to m^ma^o> f jurajame bawiin of contJORZO WA Oat Re Leone ** PROma PROma Leone NAVSIC Code 6101 6101 MT rs er mee NIIae 8 A. - Ts EWES 4670 discoustavamre of making making of come reves ee 1 dangumand en Ax awe ne et eee Meme 6 Raced me ad Re a Winer 064 064 me ... ' Y ape ere + ... nald... ... fee ta ag ee i ted eld y ae Ca umn) NL BUSAND^( ON D7CM vutde 1 Mr. Mr. . oc, Wisherd Wisherd Wisherd ee eee ee : DESCRIPTION DESCRIPTION TOI seme ca DESCRIPTION FEDERAL DESCRIPTION PATTERN M3 " oa DIAM DESCRIPTION ' (7) | DIADM IAM IN ATTACHEU INVENTONY ALCOMMENCED ALCOMMENCED INVENTONY : NARIGIO 6,144 #1 Pry Ser eee ary o TRANSFER i FLMUANCE RECOMENDATION FOR SUPER RECOMMENDATION 1) NEW ITEM SLOUME tw ae tS Grae Protective Blanket High Temperature Silicom Silicom Silicom NAME OF ITEM DESCRIPTIOtt For new turar's Insert in cazabal lettera dems describe in detall specification drawing or on 00 FORM 148. using fo largi Description Pi^-are il , ocurement ocurement reference number and ing DOVER Saulist oe CAute ae ee ..... HH .... ae Fetes yee Continuous filament fibrous glass fabric 9,026 fach nu,,12 6 Square yard coated both sides with silicone silicone kayin S2351 to a nominal thickness of 0.039 unch and rivomkinki yard The material shall comply with MIL STD 767 and 11LL nominal width in 50 yard rolls White in color wert Ess set, i Manufacturers Trade Name FABRICOTE Item Code 1784 Cwhite! Manufacturer Fabricote Division of Los Angeles CA YOQUI & Clawn Fabrik t ae. ooo sth tte ty, if mats apper u karded wer plain sheria shM^ NHIS Poer d Ht. 006 chor cag @@ b ves te ams BOE MPR srSe EIOR apmin orreumse ost! BLASON FOR BECOMMENDATIOBNECOMMENDATION Urgent requirement asbestos fibers is to eliminate watemtom comtaginere vate bade. 1 serious health hazard emt -- news ener rns cmemrem Fre bbe. - - FOR SUPERSEDED SUPERSEDED SUPERSEDED AND Dholak SHOE COED ST^TEM OF INITIATING ACTIVITY FOR NEW ITEMS AND TRANSFERS TRANSFERS OR ST^ TST^ETEMM VLOCKS 1 26 STOCK DATA gi gi resh^ preby na L LR ~ R~ N N -- -~ - teeat 8 4th | PART MONTHS | Tw .../ se .../| FEM OR STOKE NO ESTIMATED MEN1 N CEMENT CEMENT LIS Om NERD cate | i t i FABRICOTE 1584 WHITE 80,000 van 1 LECUTING OFFICIAL OFFICIAL NE me talla and * i a poe 4 pSyanseres | 56.25 yd \ | .- 0418 , 0418 ACTIUM HY HLISANIJA HLISANIJA = LELENTING BUT I~ ia skaantd se alt renee 4 meee mre gmerered DATE 502671 am &ers OMS ITEM CONTROL RECOMMENDATION ter 30-515 HAVSOP FORM mee aw 30-515 NOTC @ um in frommending ) Wanism l umfrommending af fromending frommending we ow rs 6 ^nurma 3 duco^-punchesof docking af demo of t^tlanir pavenretes naman: 3 wargames of am temi ( ) findet findet i un Cems fae otters Winer &. ate. - D6A8 TE PROMI LANOVIJ NAVSIC Code 6101 Mr. A. Winer T LOCAL 93658 a Ws; detuned (ites SPCC SPCC SPCC Code Te FAN IN ATTACHED (7) 5641 RECOMMENDATION TRANSILA FOR[ ... DISCOOL [)Q TINUANCE FT}sttune Mr J. Wisherd FERGAAL DESCRIPIKIN FETTIKNAG FEDERAL | ENTORY ENTORY RECOMMENBLO MANIGER US50 meTSIERbUesAe R&Y Ma Lifange ghtweight High T TempeeramtureperatuTemrpereature ghtweighgt htweight Protective BlaBlnankketet Blanket High AsAbsebsetsotsos Asbestos FrFereezez ProtPreotcecttivieve NAME OF ITEIA Linsert in copand hueres reference DESCRIPTION For new turer's stems optcribe in detail specification drawing ca 00 FORM 146 pidiurament pidiurament pidiurament reference Pesoras Pesoras basrotation Pattarn in dubitened Indiesto using number sig indiesta ^reansturchi at kundig Mintaer Federal beli beli yard " amorphous ulica fabri , umewated, Continuous filament chee gba bbty Hall maintain 18 ounces per square Chloride content shall comply with MIL Tu be 36 50 to 55 yard rolls Natural color 026 pes } 1 aD et Eraa ries, ta sae ee vaste ae inenes Maj wae 140 Manufacturers Trade Name REFRASIL Manufacturer Materials Division of Street Cardena CA. 90249 Item Code 60-100-48 HITCO Armco Steel Corporation 1600 West 135th KECOMMENDATION KECOMMENDATION Poor 1 of J te, 008 hoe mg soch she some and roomm 'the se of muring a wh If more spare needed wie piem shorts sumberme sumberme them asbestos containing materials materials FEASON FOR Urgent requirement to eliminate health hazard Breathing asbestos fibers in a serious ANTRDANSbFaERrSd an af 2900) | E FOR SUPERSEDED ANG DISCONTINUED TEMS ; OF INITIATING ACTIVITY FOR NEW ITEMS AND TRANSFERS ON SYSTEM STOCKS . STOCK DATA ( 06d | ON Ane UN ONBLA | ACCOUNT UNIT PRICE Nit of 13548 ESTIMAED | ESTIMATED TEARLY GLOUTGE FAST & MONIN | | ; TIEM DE SIEK KA NEXTS New dels emp REFRASIL 100-48 , 30,000 yds CICUTING CICUTING OFF10164 OFF10164 Nathe luft and todel 6.58 | yd | | * * (Stpansered Dall | ACTION BY HUSANDA LILLIAMS LILLIAMS OFF 8 Name and later (Sqgeaters} = 35 DATE pane ee ee ee 502672 502672 502672 502672 502672 wwe. P VS