Document 152QdmZEKk4vgZBG8vw7qkbE
SC-ELEC-00032
Solid Switchboard Wire (UL Type AVB]
Table Bt 600 Volts, Max. Operating Tamp. BOC
Construction: Switchboard wiras B and BS differ in conductor type. Table B wire* are solid tinned copper, BS wires are stranded tinned copper, in both, varnished cambric insulation is covered with a felted wall of asbestos and a cotton braid having a flame and moisture-resistant finish.
Application; Both wires are recommended where premium quality construction is required.
Advantages Heavy wait of asbestos and varnished cambric offers high dielectric strength end reliable operation under severe operating conditions.
Haatal TkiduMts--Mils
Haatal
Baa FinishId
Olaaattr
FllttS
Cattaa
Diaattar
Sia
IscJms
VC
Watt
BrtM
Aapactty*
lachts
14 .064 30 20 16 25 .200 12 .081 30 20 16 30 .220
10 .102 30 20 8 .128 30 20 6 .162 40 30
4 204 40 30 3 .229 40 30 2 .258 40 30 1 .289 40 40
0 .325 40 40
00 .365 40 40
000 .410 40 40
oooo
.460
40
40
17 40 .240 17 50 .270 17 70 .340 17 90 .380 20 105 .415 20 120 .445 20 140 .495 20 155 .630 20 185 .570 20 210 .615 20 236 .665
Ampacity btMd on 3 conductors in conduit or oncioaad cabinet 30*C. ambient at SO'C. conductor tamparaturas.
Abprsxfouti Hatwtim
is Lbs. par 1000'
30 40
55 80 125
175 215 260 330
405 495 610 750
Stranded Switchboard Wire (UL Type AVB)
Table BS, 600 Volts, Max. Operating Temp, sms
Haatal
Bare Flailhtd
Diaattar
FllttS
Came
Diaattar
Sia Stnsdiif
Isdnt VC Watt Braid laches
14 7/.0242 12 7/.0305 10 7/.0385
.073 .092 .116
30 30 30 .
20 20 20
16 .205 16 .225 17 .250
8 7/.0486 .146 30 20 6 7/.0612 .184 40 30 4 7/.0772 .232 40 30
17 .280 17 .360 20 .415
3 7/.0867 .260 40 30 2 7/.0974 .292 40 30 1 19/.0664 .332 40 40 0 19/.0745 .373 40 40
20 .440 20 .475 20 .535 20 .575
00 19/.0837 .419 40 40
000 19/.0940 .470 40 40
0000
19/.1055
.528
40
40
20 .620 20 .670 20 .730
Ampacity basad on 3 conductor* in conduit or enclosed cabinet 30*C. ambient at 90*C. conductor tamparaturas.
Aapaclty*
25 30 40
50 70 90
105 120 140 155
185 210 235
Aepraiiaats HatWalftt
tali*, par 1000'
35 45 60
80 130 185
225 280 345 420
515 630 780
Flexible Stranded Hinge Cable (ULType AVB]
Table BK, Max. Operating Temp. BOC
___
Construction: Flexible stranded tinned copper conductor, varnished cambric insulation covered with a felted wall of asbestos and a cotton braid with a flame and moistureresistant finish. Application: These switchboard wires are recommended for
installations whert e premium quality, flexible stranded con struction is desired.
Advantages: Heavy wall of varnished cambric and felted as bestos offers high dielectric strength and reliable operation under severe operating conditions.
Strasdltf Tiaead
Bara Diaattar
laches
Hiatal Tfclduiu--Mill
VC Insert
IstFaltad 2nd FattiS Wail Wall
Cottas Braid
ttsaissl Fhrishtd Diaattar lacIts
41/.010
.075 30 10 15 16 .220
65/.010
.095
30
10
15 17 .240
104/.010
.120 30 10 15 17 .265
133/.0111 .167 30 10 15 17 .315
Ampacity basad an 3 conductors in conduit or snetosad cabinet. 30*C. ambiant at H'C. conductor tamparaturas.
Appradaitt
Awptcity* HitnW*a.H/ihrt
25 35 30 45 40 60 50 90
1 RBB 00529
Solid Switchboard Wire (UL Type TA)
Table XB, BOO Volts, Max. Operating Temp. SOC
Construction: Switchboard wires XB and XBS differ in conduc tor type. Table XB wires are solid tinned copper XBS wires are stranded tinned copper. In both, PVC insulation is covered with a felted wall of asbestos and a cotton braid having a flame and moisture-resistant finish.
Application: Both wires are recommended for switchboards, particularly where moisture may be present and aither solid or stranded conductors are desired.
Advantages: The moisture-resistant wall of polyvinyl chloride over the conductor combines with felted asbestos to provide excellent service reliability.
Minimem
Nominal Thickness--Mils
Nemiaal
Apprexiaute
Standard
Thermoplastic
Finished
Nat Weight
Shipping
Diameter
Insulatica
Felted
Cfttea
Diameter
la Us.
Length
sin
Inches Mils Walt Braid
Inches
par loos'
Feet
14 .064 20 20 16 .185 12 .061 20 20 16 .200 10 .102 20 20 16 .225 S .128 20 20 17 .250
30 500'C 40 500'C 55 500'C 75 500'C
6 .162 30 25 17 .315 120 500'R 4 .204 30 25 17 .360 175 500'R 3 .229 30 25 17 .385 210 500'R 2 .258 30 25 20 .420 260 500' R
Ampacity bleed on 3 conductor* in conduit or enclosed cabinet 30*C. ambient at 9C*C. conductor temperature*.
Ampacity*
25 30 40 50
70 90 105 120
Stranded Switchboard Wire (UL Type TA}
Table XBS, BOO Volts, Max. Operating Temp. 90C
Sin Stranding
Ban Diam. Inches
Miniums Heminal Thickness-Mils
Thermoplastic
Insulation Fitted
Cettea
Mile Wall Braid
Nemiaal FMshtd Diamatsr inefets
Appro. Nat Wit in Us. per 1000'
14 7/.0242
.073 20 20
16 .195
12 7/.0305 .092 20 20 16 .215
10 7/.0385 .116 20 20
17 .240
8 7/.0486 .146 20 20 17 .270
32 41 56
79
6 7/.0612 .184 30 25 17 .340 125 4 7/.0772 .232 30 25 17 .395 180 3 7/.0S67 .260 30 25 20 .425 240 2 7/.0974 .292 30 25 20 .455 265
1 19/.0664 .332 40 30 20 .525 345
0 19/.0745 .373 40 30 20 .565 420
00 19/.0837 .419 40 30 20 .610 515
000 19/.094O .470 40 30 20 .660 635
0000
19/.1055
.528
40
30
20
.720
780
Ampacity baaed on 3 conductor* in conduit or enclosed cabinet 30*C. embiant *t SO* C. conductor temperature*.
Standard Shipping Length
Feet
500'C 500'C 500'C 500'C
500'R 500* R 500'R 500'R
500' R 500' R 500'R 500'R 500'R
Amptcity*
25 30 40 50
70 90 105 120
140 155 185 210 235
Flexible Stranded Switchboard Wire (UL Type TA}
Table XBH, 600 Volts, Max. Operating Temp. 90C
Construction: Flexible stranded tinned copper, PVC insulation covered with a feitad wail of asbestos and a flameproof cotton raid*
Application: General purpose switchboard wire where a flexible foundation is desired, such as hinge cable applications.
Advantages: Table XBH switchboard wire has a moistureresistant wall of polyvinyl chloride over the conductor which,
combined with felted asbestos, provides an excellent com-
bination for service reliability,
Minimum Nsnt Thickness-Mils Nemiaal
Appro.
Bare Themepiastie
Finlshtd
Net Wit
01am, Imlatiei Fitted Cettee
Diameter
in Us.
Size
Strndlsf
laches
Mils Weil Braid
Inches
per 1000'
14 41/.010 12 65/.010
.075 .095
20 20
20 20
16 16
.195 .215
10 104/.010
.120
20
20
17
.245
8 133/.0111
.167
20
20
17
.290
31 42 57 84
6 133/.0140
.210
30 25
17
.365
130
4 133/.0177
.266
30
25
20
.425
190
3 133/.0199
.299
30
25
20
.460
230
2 133/.0223
.335
30
25
20
.495
280
1 259/.0180
.378
40
30
20
.570
360
0 259/.0202
-424
40
30
20
.615
435
00 259/.0227
.477
40
30
20
.670
535
000 259/.0255
.536
40
30
20
.730
660
0000
259/.0286
.601
40
30
20
.795
810
Ampacity baaed on 3 conductor* in conduit or tndoeod cabinet 30 *C. ambient at 90`C. conductor temperature*.
Stiadtrd Shipping Length
Feet
500'C 500'C 500'C 500'C
500' R 500'R 500'R 500'R
500'R 500' R 500'R 500'R 500'R
Ampacity*
25 30 40 50
70 90 105 120
140 155 185 210 235
RBB 00530
Solid Switchboard Wire (UL Type TBS)
Table SPB, 608 Volts, Max. Operating Temp. 90C
Construction: Solid tinned copper conductor insulated with an extrusion of PVC and covered with a flame-proof cotton braid. Application: General purpose 600 volt switchboard wire, requiring a solid conductor. Advantages: Minimum diameter and weight and low initial cost
Ii
Siam
StraoSiag
Insolation Mils
Braid Mils
taMctty*
14 Solid 31 12 Solid 31 10 Solid 31
16 16 16
8 Solid 47 17 6 Solid 63 17
25 30 40
50 70
'Ampacity baud on 30*C. ambiant at 90'C. conductor temperatures, 3 conductor* in conduit, par NEC.
Nominal Finished Diameter leches
.163 .180 .201
.222 .325
Stranded Switchboard Wire [UL Type T BS)
Table SPSS, 680 Volta, Max. Operating Temp. 90C
Contraction: Stranded tinned copper insulated with a PVC ex trusion and covered with a flame-proof cotton braid. Application: General purpose switchboard wire where a stranded conductor is desired. Advantages: Smell diameter, light weight and minimum cost
SiaAWB
Stranding
Insulation Mils
Braid Milt
Ampacity*
14 7/.0242 31 16 25 12 7/.0305 31 16 30 10 7/.0385 31 16 40
8 7/.0486 47 17 50 6 7/.0612 63 17 70
*Ampectty
on 3Q*C. tmbtwnt at 90*C- conductor tomporaturss, 3 conductors in conduit por NEC.
Naminal Finished Diameter India
.172 .191 .215
.279 .349
.
Jtppni. NttWft in Us. per100<7
26 36 50 81 124
|5WmU)WA!WS
Approx. NltWgL in Us. per 100(7
28 37 52 85 133
c
Flexible Stranded Switchboard Wire [UL Type TBS)
Table SPBH, 600 Volts, Max. Operating Temp. 90C
Construction: Flexible stranded tinned copper insulated with an extrusion of PVC and covered with a flame-proof cotton braid. Application: General purpose 600 volt switchboard wire where a flexible copper foundation is desired. Advantages: Smalt diameter, tight weight and minimum cost
SiaAWG
Stranding
Ingiatisn Mila
Braid Mbs
Ampacity*
14. 41/.010
31
16
25
12 65/.010 31 16 30
10 104/.010
31
16
40
8 133/.0111 47 17 50
6
49/.0231
63
17
70
Ampacity based on 30*C. ambiant atSO'C. conductor tamparaturas, 3 conductors in conduit, par NEC.
NimiMl Finland Diameter Inches
.174 .194 .219
.300 .350
3
Apprax. NttWft in Lbs. par 101X7
28 38 53 86 146
RBB 00531
0 X Link* Polyethylene Solid Switchboard Wire (ULType SIS)
Table SIS, 600 Volts, Max. Operating Temp. 9QC
Construction: Solid tinned copper, cross-linked polyethylene insulation.
Application: General purpose 600 volt switchboard wire, solid conductor.
Advantages: Minimum diameter and weight, tough extruded insulation with no outer covering.
MR.
luptatfu
NtMlnal
Nat
Sin Stmdiat Mils
O.D.
Wight
Ampacity*
14 Solid 31 .130 19
12 Solid 31 .150 28
10 Solid 31 .170 41
8 6
Solid Solid
47 62
.230 .300
n6o9
`Ampacity bated on 3 conductors in conduit or enclosed cabinet. 30*C. ambient at 90*C. conductor temperatures.
25 30 40 , 50 70
X Link Polyethylene Stranded Switchboard Cable (UL Type SIS)
Table SISS, 600 Volts, Max. Operating Temp. 900
Construction: Stranded tinned copper conductors insulated with an extrusion of cross-linked polyethylene. Application: General purpose 600 volt switchboard wire where a stranded conductor is desired.
Advantages: Moisture-resistant, tough extruded insulation with no outer covering.
MR.
. Insalatjta
Ncmiaal
Nt
Sin
Straadiag
Mils OD. Weight
14 7/.0242 31 .140 20
12 7/.0305 31 .160 28
10
7/.0385
31
.180
42
8
7/.0486
47
.250
70
6 7/.0612 62 .320 113
4 7/.0772 62 .370 167
2 7/.0994 62 .430 251
1
19/.0664
62
.470
310
1/0 19/.0745 78 .545 398
2/0
19/.0837
78
.590
489
3/0 19/.0940 78 .640 604
4/0 19/. 1055 78 .700 750
Ampacity based on 3 conductors in conduit or enclosed cabinet 30*C. ambient at 90*C. conductor temperatures.
Ampacity*
25 30 40 50
70 90 120 140
155 185 210 235
X Link Polyethylene Flexible Stranded Switchboard Wire (UL Type SIS)
Table SISF, 800 Volts, Max. Operating Temp. 90C
Construction: Flexible stranded tinned copper insulated with an extrusion of cross-linked polyethylene. Application: General purpose 600 volt switchboard wire where a flexible stranded copper conductor is desired.
Advantages: Moisture-resistant tough extruded insulation with no outer covering.
MR.
InsDlstiii
Ncmlsal
Nat
Sin Strutting
Mils 0.0. Wiight
14 41/.010 31 .140
12 65/.010 31 .160
10 105/.010
31 .190
8 133/.0111 47 .270
20 28 43 75
6 133/.0140 62 .340 119
4 133/.0177 62 .400 170
2 133/.0223 62 .470 254
1
259/.0180
62
.515
326
1/0
259/.0202
78
.595
412
2/0 259/.0227 78 .650 508
3/0 259/.0255 78 .710 630
4/0 259/.0286 78 .770 780
`Ampacity baaed on 3 conductors in conduit of eneJpsed cabinet 30 C. ambient at 90*C. conductor temperature*.
Ampacity*
25 30 40 50
70 90 120 140
155 185 210 235
RBB 00532
I
Stranded Hook-Up Wire
Table EMA, 1000 Volts, Max. Operating Temp. 90C
Construction: Stranded tinned copper insulation with 10 mils of synthetic tape, covered with a solid wall of asbestos and a cotton braid with a heat and moisture resisting finish. Application'. Table EMA conductors are recommended for use where a 1000 volt 90*C. lead wire is desired. Advantages: Small diameter and high quality construction make this construction advantageous for lead wire where the greatest degree of reliability is desired.
sinAWfi
Strutting
bn Diameter
IbcIms
Nnntintl Tkidumu-lackcs
Synthetic Tape
Felted WlU
BnM TMekim
Ntaisai FMstad Dlut In. lapsetty*
14 19/.0142 .071 .010 .020 12 19/.0179 .090 .010 .020
.0125 .0125
.156 .175
30 40
Amp*city baaed on 30*C. ambient it 90*C. conductor temperature*. 3 conductors in conduit per NEC.
Apptw. Met Wit In Us. per 1000'
23 31
Standard Skipping Length
Feet
500'C 500' C
I
Flexible Stranded Hook-Up Wire
Table ZM, 1000 Volts, Max. Operating Temp. I25C
Construction: Stranded tinned copper covered with synthetic tapes and insulated with solid asbestos and a glass braid overall. Application: Table ZM conductors ere recommended for use where e high quality, 1000 volt hook-up wire is desired. Advantages: Small diameter and high dielectric properties make this construction advantageous for specialty 125*C. lead wire applications.
Sin AWE Stranding
Bart Dleawter
Inckns
NnajuJ Thickness-Inches
Synthetic Tape
Fnltad Wail
Braid Tkicknest
Nualttl Flnttked Dlaa. ini.
18 16/.010 16 26/.010 14 41/.010 12 65/.010 10 104/.010
.045 .059 .075 .095 .120
.0065 .0065 .010 ,010 .010
.0085 .0085 .0085 .010 .010
.0075 .010 .010 .010 .010
.090 .109 .132 .155 .180
'Ampacity beeed on 30'C. ambient at 125*C. conductor tempereturee, 3 conductors in conduit perNEG.
Ampacity*
20 30 40 50 70
Apprsi. Kit Wit fnUa. per 1000'
8 12 19 28 42
Standard Shipping length
Fart
1000's 1000'S 1000'S 1000'S 1000'S
\
J
5 00533
Type PN High Molecular Weight Polyethylene-Nylon Control Wire
600 Volts, Singls Conductor, Max. Operating Temp. 7SC
Construction; Stranded bore copper conductors insulated with color coded, high molecular weight polyethylene, covered with e nylon sheath. Application: Type PN conductor is recommended for general purpose 600 volt machine tool wire applications. Advantages: Very small diameter end high quality electrical insulation provide an excellent combination for industrial wir ing applications, particularly where exposed to oil and chemi cal environments.
Sh
Stnsdtag
NmMOJ.
Weight
mo 9 19/22 .171 PHT 12 19/25 .134 m 14 19/27 .116
40 20 15
Ampacity based on 30*C. ambient at 75*C- conductor temperature*. 3 conductors in conduit per NEC.
lapsed**
35 20 15
Type PNX Linear Polyethylene-Nylon Control Wire
BOO Volts, Single Conductor, Max. Operating Temp. 80C
Construction: Stranded tinned copper conductors insulated with color coded, high density polyethylene, covered with nylon sheath. Application: Type PNX conductor is recommended for general purpose 600 volt machine tool wire applications. Advantages: Very small diameter and high quality electrical insulation provide an excellent combination for industrial wir ing applications, particularly where exposed to oil and chemi cal environments.
Sia
Stnsdiaf
dsaital OJ.
Wtifht
PHTX PHD* PAR
9 12 14
19/22 19/25 19/27
.190 .152 .134
53 28 22
Ampseity based an 30"C. smbisnt at 90*C. conductor temperature* 3 conductors In conduit per NEC.
lapsed**
45 30 25
RBB 00534