Document 152QdmZEKk4vgZBG8vw7qkbE

SC-ELEC-00032 Solid Switchboard Wire (UL Type AVB] Table Bt 600 Volts, Max. Operating Tamp. BOC Construction: Switchboard wiras B and BS differ in conductor type. Table B wire* are solid tinned copper, BS wires are stranded tinned copper, in both, varnished cambric insulation is covered with a felted wall of asbestos and a cotton braid having a flame and moisture-resistant finish. Application; Both wires are recommended where premium quality construction is required. Advantages Heavy wait of asbestos and varnished cambric offers high dielectric strength end reliable operation under severe operating conditions. Haatal TkiduMts--Mils Haatal Baa FinishId Olaaattr FllttS Cattaa Diaattar Sia IscJms VC Watt BrtM Aapactty* lachts 14 .064 30 20 16 25 .200 12 .081 30 20 16 30 .220 10 .102 30 20 8 .128 30 20 6 .162 40 30 4 204 40 30 3 .229 40 30 2 .258 40 30 1 .289 40 40 0 .325 40 40 00 .365 40 40 000 .410 40 40 oooo .460 40 40 17 40 .240 17 50 .270 17 70 .340 17 90 .380 20 105 .415 20 120 .445 20 140 .495 20 155 .630 20 185 .570 20 210 .615 20 236 .665 Ampacity btMd on 3 conductors in conduit or oncioaad cabinet 30*C. ambient at SO'C. conductor tamparaturas. Abprsxfouti Hatwtim is Lbs. par 1000' 30 40 55 80 125 175 215 260 330 405 495 610 750 Stranded Switchboard Wire (UL Type AVB) Table BS, 600 Volts, Max. Operating Temp, sms Haatal Bare Flailhtd Diaattar FllttS Came Diaattar Sia Stnsdiif Isdnt VC Watt Braid laches 14 7/.0242 12 7/.0305 10 7/.0385 .073 .092 .116 30 30 30 . 20 20 20 16 .205 16 .225 17 .250 8 7/.0486 .146 30 20 6 7/.0612 .184 40 30 4 7/.0772 .232 40 30 17 .280 17 .360 20 .415 3 7/.0867 .260 40 30 2 7/.0974 .292 40 30 1 19/.0664 .332 40 40 0 19/.0745 .373 40 40 20 .440 20 .475 20 .535 20 .575 00 19/.0837 .419 40 40 000 19/.0940 .470 40 40 0000 19/.1055 .528 40 40 20 .620 20 .670 20 .730 Ampacity basad on 3 conductor* in conduit or enclosed cabinet 30*C. ambient at 90*C. conductor tamparaturas. Aapaclty* 25 30 40 50 70 90 105 120 140 155 185 210 235 Aepraiiaats HatWalftt tali*, par 1000' 35 45 60 80 130 185 225 280 345 420 515 630 780 Flexible Stranded Hinge Cable (ULType AVB] Table BK, Max. Operating Temp. BOC ___ Construction: Flexible stranded tinned copper conductor, varnished cambric insulation covered with a felted wall of asbestos and a cotton braid with a flame and moistureresistant finish. Application: These switchboard wires are recommended for installations whert e premium quality, flexible stranded con struction is desired. Advantages: Heavy wall of varnished cambric and felted as bestos offers high dielectric strength and reliable operation under severe operating conditions. Strasdltf Tiaead Bara Diaattar laches Hiatal Tfclduiu--Mill VC Insert IstFaltad 2nd FattiS Wail Wall Cottas Braid ttsaissl Fhrishtd Diaattar lacIts 41/.010 .075 30 10 15 16 .220 65/.010 .095 30 10 15 17 .240 104/.010 .120 30 10 15 17 .265 133/.0111 .167 30 10 15 17 .315 Ampacity basad an 3 conductors in conduit or snetosad cabinet. 30*C. ambiant at H'C. conductor tamparaturas. Appradaitt Awptcity* HitnW*a.H/ihrt 25 35 30 45 40 60 50 90 1 RBB 00529 Solid Switchboard Wire (UL Type TA) Table XB, BOO Volts, Max. Operating Temp. SOC Construction: Switchboard wires XB and XBS differ in conduc tor type. Table XB wires are solid tinned copper XBS wires are stranded tinned copper. In both, PVC insulation is covered with a felted wall of asbestos and a cotton braid having a flame and moisture-resistant finish. Application: Both wires are recommended for switchboards, particularly where moisture may be present and aither solid or stranded conductors are desired. Advantages: The moisture-resistant wall of polyvinyl chloride over the conductor combines with felted asbestos to provide excellent service reliability. Minimem Nominal Thickness--Mils Nemiaal Apprexiaute Standard Thermoplastic Finished Nat Weight Shipping Diameter Insulatica Felted Cfttea Diameter la Us. Length sin Inches Mils Walt Braid Inches par loos' Feet 14 .064 20 20 16 .185 12 .061 20 20 16 .200 10 .102 20 20 16 .225 S .128 20 20 17 .250 30 500'C 40 500'C 55 500'C 75 500'C 6 .162 30 25 17 .315 120 500'R 4 .204 30 25 17 .360 175 500'R 3 .229 30 25 17 .385 210 500'R 2 .258 30 25 20 .420 260 500' R Ampacity bleed on 3 conductor* in conduit or enclosed cabinet 30*C. ambient at 9C*C. conductor temperature*. Ampacity* 25 30 40 50 70 90 105 120 Stranded Switchboard Wire (UL Type TA} Table XBS, BOO Volts, Max. Operating Temp. 90C Sin Stranding Ban Diam. Inches Miniums Heminal Thickness-Mils Thermoplastic Insulation Fitted Cettea Mile Wall Braid Nemiaal FMshtd Diamatsr inefets Appro. Nat Wit in Us. per 1000' 14 7/.0242 .073 20 20 16 .195 12 7/.0305 .092 20 20 16 .215 10 7/.0385 .116 20 20 17 .240 8 7/.0486 .146 20 20 17 .270 32 41 56 79 6 7/.0612 .184 30 25 17 .340 125 4 7/.0772 .232 30 25 17 .395 180 3 7/.0S67 .260 30 25 20 .425 240 2 7/.0974 .292 30 25 20 .455 265 1 19/.0664 .332 40 30 20 .525 345 0 19/.0745 .373 40 30 20 .565 420 00 19/.0837 .419 40 30 20 .610 515 000 19/.094O .470 40 30 20 .660 635 0000 19/.1055 .528 40 30 20 .720 780 Ampacity baaed on 3 conductor* in conduit or enclosed cabinet 30*C. embiant *t SO* C. conductor temperature*. Standard Shipping Length Feet 500'C 500'C 500'C 500'C 500'R 500* R 500'R 500'R 500' R 500' R 500'R 500'R 500'R Amptcity* 25 30 40 50 70 90 105 120 140 155 185 210 235 Flexible Stranded Switchboard Wire (UL Type TA} Table XBH, 600 Volts, Max. Operating Temp. 90C Construction: Flexible stranded tinned copper, PVC insulation covered with a feitad wail of asbestos and a flameproof cotton raid* Application: General purpose switchboard wire where a flexible foundation is desired, such as hinge cable applications. Advantages: Table XBH switchboard wire has a moistureresistant wall of polyvinyl chloride over the conductor which, combined with felted asbestos, provides an excellent com- bination for service reliability, Minimum Nsnt Thickness-Mils Nemiaal Appro. Bare Themepiastie Finlshtd Net Wit 01am, Imlatiei Fitted Cettee Diameter in Us. Size Strndlsf laches Mils Weil Braid Inches per 1000' 14 41/.010 12 65/.010 .075 .095 20 20 20 20 16 16 .195 .215 10 104/.010 .120 20 20 17 .245 8 133/.0111 .167 20 20 17 .290 31 42 57 84 6 133/.0140 .210 30 25 17 .365 130 4 133/.0177 .266 30 25 20 .425 190 3 133/.0199 .299 30 25 20 .460 230 2 133/.0223 .335 30 25 20 .495 280 1 259/.0180 .378 40 30 20 .570 360 0 259/.0202 -424 40 30 20 .615 435 00 259/.0227 .477 40 30 20 .670 535 000 259/.0255 .536 40 30 20 .730 660 0000 259/.0286 .601 40 30 20 .795 810 Ampacity baaed on 3 conductor* in conduit or tndoeod cabinet 30 *C. ambient at 90`C. conductor temperature*. Stiadtrd Shipping Length Feet 500'C 500'C 500'C 500'C 500' R 500'R 500'R 500'R 500'R 500' R 500'R 500'R 500'R Ampacity* 25 30 40 50 70 90 105 120 140 155 185 210 235 RBB 00530 Solid Switchboard Wire (UL Type TBS) Table SPB, 608 Volts, Max. Operating Temp. 90C Construction: Solid tinned copper conductor insulated with an extrusion of PVC and covered with a flame-proof cotton braid. Application: General purpose 600 volt switchboard wire, requiring a solid conductor. Advantages: Minimum diameter and weight and low initial cost Ii Siam StraoSiag Insolation Mils Braid Mils taMctty* 14 Solid 31 12 Solid 31 10 Solid 31 16 16 16 8 Solid 47 17 6 Solid 63 17 25 30 40 50 70 'Ampacity baud on 30*C. ambiant at 90'C. conductor temperatures, 3 conductor* in conduit, par NEC. Nominal Finished Diameter leches .163 .180 .201 .222 .325 Stranded Switchboard Wire [UL Type T BS) Table SPSS, 680 Volta, Max. Operating Temp. 90C Contraction: Stranded tinned copper insulated with a PVC ex trusion and covered with a flame-proof cotton braid. Application: General purpose switchboard wire where a stranded conductor is desired. Advantages: Smell diameter, light weight and minimum cost SiaAWB Stranding Insulation Mils Braid Milt Ampacity* 14 7/.0242 31 16 25 12 7/.0305 31 16 30 10 7/.0385 31 16 40 8 7/.0486 47 17 50 6 7/.0612 63 17 70 *Ampectty on 3Q*C. tmbtwnt at 90*C- conductor tomporaturss, 3 conductors in conduit por NEC. Naminal Finished Diameter India .172 .191 .215 .279 .349 . Jtppni. NttWft in Us. per100<7 26 36 50 81 124 |5WmU)WA!WS Approx. NltWgL in Us. per 100(7 28 37 52 85 133 c Flexible Stranded Switchboard Wire [UL Type TBS) Table SPBH, 600 Volts, Max. Operating Temp. 90C Construction: Flexible stranded tinned copper insulated with an extrusion of PVC and covered with a flame-proof cotton braid. Application: General purpose 600 volt switchboard wire where a flexible copper foundation is desired. Advantages: Smalt diameter, tight weight and minimum cost SiaAWG Stranding Ingiatisn Mila Braid Mbs Ampacity* 14. 41/.010 31 16 25 12 65/.010 31 16 30 10 104/.010 31 16 40 8 133/.0111 47 17 50 6 49/.0231 63 17 70 Ampacity based on 30*C. ambiant atSO'C. conductor tamparaturas, 3 conductors in conduit, par NEC. NimiMl Finland Diameter Inches .174 .194 .219 .300 .350 3 Apprax. NttWft in Lbs. par 101X7 28 38 53 86 146 RBB 00531 0 X Link* Polyethylene Solid Switchboard Wire (ULType SIS) Table SIS, 600 Volts, Max. Operating Temp. 9QC Construction: Solid tinned copper, cross-linked polyethylene insulation. Application: General purpose 600 volt switchboard wire, solid conductor. Advantages: Minimum diameter and weight, tough extruded insulation with no outer covering. MR. luptatfu NtMlnal Nat Sin Stmdiat Mils O.D. Wight Ampacity* 14 Solid 31 .130 19 12 Solid 31 .150 28 10 Solid 31 .170 41 8 6 Solid Solid 47 62 .230 .300 n6o9 `Ampacity bated on 3 conductors in conduit or enclosed cabinet. 30*C. ambient at 90*C. conductor temperatures. 25 30 40 , 50 70 X Link Polyethylene Stranded Switchboard Cable (UL Type SIS) Table SISS, 600 Volts, Max. Operating Temp. 900 Construction: Stranded tinned copper conductors insulated with an extrusion of cross-linked polyethylene. Application: General purpose 600 volt switchboard wire where a stranded conductor is desired. Advantages: Moisture-resistant, tough extruded insulation with no outer covering. MR. . Insalatjta Ncmiaal Nt Sin Straadiag Mils OD. Weight 14 7/.0242 31 .140 20 12 7/.0305 31 .160 28 10 7/.0385 31 .180 42 8 7/.0486 47 .250 70 6 7/.0612 62 .320 113 4 7/.0772 62 .370 167 2 7/.0994 62 .430 251 1 19/.0664 62 .470 310 1/0 19/.0745 78 .545 398 2/0 19/.0837 78 .590 489 3/0 19/.0940 78 .640 604 4/0 19/. 1055 78 .700 750 Ampacity based on 3 conductors in conduit or enclosed cabinet 30*C. ambient at 90*C. conductor temperatures. Ampacity* 25 30 40 50 70 90 120 140 155 185 210 235 X Link Polyethylene Flexible Stranded Switchboard Wire (UL Type SIS) Table SISF, 800 Volts, Max. Operating Temp. 90C Construction: Flexible stranded tinned copper insulated with an extrusion of cross-linked polyethylene. Application: General purpose 600 volt switchboard wire where a flexible stranded copper conductor is desired. Advantages: Moisture-resistant tough extruded insulation with no outer covering. MR. InsDlstiii Ncmlsal Nat Sin Strutting Mils 0.0. Wiight 14 41/.010 31 .140 12 65/.010 31 .160 10 105/.010 31 .190 8 133/.0111 47 .270 20 28 43 75 6 133/.0140 62 .340 119 4 133/.0177 62 .400 170 2 133/.0223 62 .470 254 1 259/.0180 62 .515 326 1/0 259/.0202 78 .595 412 2/0 259/.0227 78 .650 508 3/0 259/.0255 78 .710 630 4/0 259/.0286 78 .770 780 `Ampacity baaed on 3 conductors in conduit of eneJpsed cabinet 30 C. ambient at 90*C. conductor temperature*. Ampacity* 25 30 40 50 70 90 120 140 155 185 210 235 RBB 00532 I Stranded Hook-Up Wire Table EMA, 1000 Volts, Max. Operating Temp. 90C Construction: Stranded tinned copper insulation with 10 mils of synthetic tape, covered with a solid wall of asbestos and a cotton braid with a heat and moisture resisting finish. Application'. Table EMA conductors are recommended for use where a 1000 volt 90*C. lead wire is desired. Advantages: Small diameter and high quality construction make this construction advantageous for lead wire where the greatest degree of reliability is desired. sinAWfi Strutting bn Diameter IbcIms Nnntintl Tkidumu-lackcs Synthetic Tape Felted WlU BnM TMekim Ntaisai FMstad Dlut In. lapsetty* 14 19/.0142 .071 .010 .020 12 19/.0179 .090 .010 .020 .0125 .0125 .156 .175 30 40 Amp*city baaed on 30*C. ambient it 90*C. conductor temperature*. 3 conductors in conduit per NEC. Apptw. Met Wit In Us. per 1000' 23 31 Standard Skipping Length Feet 500'C 500' C I Flexible Stranded Hook-Up Wire Table ZM, 1000 Volts, Max. Operating Temp. I25C Construction: Stranded tinned copper covered with synthetic tapes and insulated with solid asbestos and a glass braid overall. Application: Table ZM conductors ere recommended for use where e high quality, 1000 volt hook-up wire is desired. Advantages: Small diameter and high dielectric properties make this construction advantageous for specialty 125*C. lead wire applications. Sin AWE Stranding Bart Dleawter Inckns NnajuJ Thickness-Inches Synthetic Tape Fnltad Wail Braid Tkicknest Nualttl Flnttked Dlaa. ini. 18 16/.010 16 26/.010 14 41/.010 12 65/.010 10 104/.010 .045 .059 .075 .095 .120 .0065 .0065 .010 ,010 .010 .0085 .0085 .0085 .010 .010 .0075 .010 .010 .010 .010 .090 .109 .132 .155 .180 'Ampacity beeed on 30'C. ambient at 125*C. conductor tempereturee, 3 conductors in conduit perNEG. Ampacity* 20 30 40 50 70 Apprsi. Kit Wit fnUa. per 1000' 8 12 19 28 42 Standard Shipping length Fart 1000's 1000'S 1000'S 1000'S 1000'S \ J 5 00533 Type PN High Molecular Weight Polyethylene-Nylon Control Wire 600 Volts, Singls Conductor, Max. Operating Temp. 7SC Construction; Stranded bore copper conductors insulated with color coded, high molecular weight polyethylene, covered with e nylon sheath. Application: Type PN conductor is recommended for general purpose 600 volt machine tool wire applications. Advantages: Very small diameter end high quality electrical insulation provide an excellent combination for industrial wir ing applications, particularly where exposed to oil and chemi cal environments. Sh Stnsdtag NmMOJ. Weight mo 9 19/22 .171 PHT 12 19/25 .134 m 14 19/27 .116 40 20 15 Ampacity based on 30*C. ambient at 75*C- conductor temperature*. 3 conductors in conduit per NEC. lapsed** 35 20 15 Type PNX Linear Polyethylene-Nylon Control Wire BOO Volts, Single Conductor, Max. Operating Temp. 80C Construction: Stranded tinned copper conductors insulated with color coded, high density polyethylene, covered with nylon sheath. Application: Type PNX conductor is recommended for general purpose 600 volt machine tool wire applications. Advantages: Very small diameter and high quality electrical insulation provide an excellent combination for industrial wir ing applications, particularly where exposed to oil and chemi cal environments. Sia Stnsdiaf dsaital OJ. Wtifht PHTX PHD* PAR 9 12 14 19/22 19/25 19/27 .190 .152 .134 53 28 22 Ampseity based an 30"C. smbisnt at 90*C. conductor temperature* 3 conductors In conduit per NEC. lapsed** 45 30 25 RBB 00534