Document 10zVN5EOM5vnj0wQVjdbyeX0d

Central Engineering Department Project Scope Report Solid Aroclor Expansion CEA 2080 New 20 M lbs./year Plant Anniston, Alabama Plant By: R. S. Yates Central Engineering Department January 14, 1969 072*6095 TOWOLDMONOQ48883 distribution Organic Division 1. J. M. Smith 2. W. A. Kuhn 3. H. L. Williams 4. W. E. Voss Central Engineering 1. R. M. Kountz 2. R. S. Yates 3. O. F. Bremer/P.K. Nunn 4. J. w. Campbell/B. W. Steketee/R. B. Degenhardt 5. L. R. Burchfield 6. F. J. Holzapfel 7. Central File 8. R. C. Herman 9. R. C. Herman 10. R. C. Herman 11. R. C. Herman 0726096 TOWOLDMONOQ48884 CEA 2080 Date: 1/16/69 By: R. S. Yates TABLE OF CONTENTS 1.1 Project Scope Summary 1.11 Title 1.12 Synopsis and Project "Tone" 1.2 Process Technology 1.21 Process Description 1.211 Details of Process 1.212 Yields and Raw Material Usage 1.213 Process Documents 1.22 Raw Materials 1.221 Specifications 1.222 Sources 1.23 Products and By-Products 1.231 1.232 1.233 1.234 Quality Considerations Specifications By-Products Packaging and Shipping 1.24 Waste Streams 1.25 Personnel, Property and Public Hazards 1.3 ManufacturingFacilities 1.31 Description 1.311 General 1.312 Manufacturing Facilities 1.32 Design Capacity 1.33 Flexibility Requirements 1.34 Future Expansion 1.35 Physical Appearance 1.36 Storage and Shipping Requirements 1.4 Utilities 1.41 Utilities Summary 1.42 Utilities Facilities Page No, x i \ 3 3 3 3 4 4 4 5 5 5 5 6 6 7 7 9 9 9 9 10 10 11 11 11 12 12 12 0726097 TOWOLDMONOQ48885 Appendices A. Equipment Information Summary B. Process Flow Diagram C. Equipment Arrangement Study D. Building and Site Requirements E. Description of Work by Code of Accounts F. Preliminary Schedule G. Project Loss Prevention Report 0726098 TOWOLDMON0048886 Page 1 1,1 Project Scope Summary 1,11 Title Aroclors - Increase Solid Aroclor Capacity - Organic Division at Anniston, Alabama Plant CEA 2080 1,12 Synopsis and Project "Tone" The objectives of this project are to a. provide new facilities to increase solid Arolor plant capacity from 9.6 M lbs./year to 29,6 M lbs./year. b. Provide an overall production capacity for solid Aroclors of up to 30% more than indicated in the latest sales forecast. c. Provide for an orderly expansion of the solid Aroclor facilities. d. Complete these facilities by December, 1969. New facilities to be added are: 1. Two batch chlorinator systems consisting of a single terphenyl feed tank, two chlorination tanks with heat removal systems and one inter mediate storage and blow tank. 2. An off-gas recovery system consisting of heat exchanger and surge tank to recover entrain ment lossss from both chlorinator systems. 3. One batch distillation system consisting of still pot, external circulating system through a gas-fired heater, condensing and receiving equipment, and a high vacuum ejector. 4. Sufficient piping tie-ins to insure good oper ating flexibility with the existing batch system. 5. Expand the existing control room to provide sufficient space for instrumentation for the new facility. 6. Expand the existing Therminol heating system to provide proper distribution of hot fluid to the new facility. 7. Add drowning facilities at the HCl plant to drown the extra HCl gas produced from the chlorinators. 0726099 TOWOLDMONOQ48887 Page 2 8. A new elevator in Building 27. 9. A flaker for Aroclor 1268. Sales forecasts indicate that we will be out of solid Aroclor capacity in 1969. The plant is carrying out a debottlenecking program which will allow us to meet most of our 1969 requirements. The new facilities should be operational by December 1969 or earlier if possible. A preliminary schedule shows that if we can start definitive engineering in January, these new facilities will be available for start-up in December 1969. Full design capacity will not be necessary until after 1973. It is divisional policy in certain product groups to provide excess capacity over and above sales forecasts and we are providing a 31% excess capacity in these new facilities for 1973 based on the sales forecast of December 6, 1968. Low capital cost is important to this project, however, schedules must be met for a December 1969 or earlier start-up even at some increased capital cost. There are no items that could be deferred from this project to a later date. It is estimated that the cost of these new facilities will be: Capital Expense Total $ 950,000 50,000 $1,000,000 0726100 TOWOLDMONOQ48888 Page 3 1.2 Process Technology 1.21 process Description 1.211 Details of Process Aroclors are the reaction products formed by the chlorination of biphenyl and/or terphenyls using an iron catalyst. The by-product HC1 gas pro duced is absorbed in water to produce muriatic acid. Solid Aroclors are produced in chlorinator reaction vessels, air blown and distilled. They are drummed, flaked, or flaked and milled and packaged for shipment. Distillation residues are discarded as waste or sold as Montars. Aroclors, when used as plasticizers and that crystallize at ambient temperatures are con sidered solid Aroclors. Below is a list of the Aroclor grades that are considered solid Aroclors: Aroclor Starting Designationi Raw Material Chlorination Level Distilled 1268 Biphenyl 68% Yes 2565 25% Santowax c 7 5% Biphenyl 6 5% NO 4065 40% Santowax R 60% Biphenyl 6 5% NO 446 5 40% Santowax R 60% Biphenyl 6 5% Yes 5060 100% Santowax R 60% No 5460 100% Santowax R 60% Yes 5042 100% Santowax R 42% No 5442 100% Santowax R 42% Yes We intend to make only Santowax R based Aroclors in this new equipment. 1.212 Yields and Raw Material Usage Yields are calculated for both chlorine and Santowax and/or Biphenyl. Based on cost standards of January 1, 1969 these are (% theory to standard): 0726101 TOWOLDMONOQ48889 Page 4 Aroclor On On On On Designation Chlorine Biphenyl Santowax C Santowax R 1268 73 73 2565 96 96.2 96.2 4465 73 73 73 5060 96 96 5460 82 85 5442 80.2 73 The yield on 5460 has not been demonstrated. Last year the standard yield on chlorine and Santowax R was 73.5% Lime and Ferric chloride are added to all products as follows: Lime Ferric Chloride Lbs./lOO Lbs. Aroclor 1.000 0.020 1.213 Process Documents "Standard Manufacturing Process for Aroclors Anniston Plant" September, 1966, M. J. Williams "Standard Operating Instructions for Aroclors Anniston Plant" November, 1968, M. J. Williams 1.22 Raw Materails 1.221 Specifications Raw material specifications, as listed below, are appended. Material Code Date Material 33500 2/26/57 Ferric Chloride Anhydride 83601 11/18/65 Biphenyl 82910 3/9/66 Santowax "C" 82602 3/2/66 Santowax "R" 82638 8/31/66 Chlorine Gas 38800 7/20/66 Lime Hydrate 0726102 TOWOLDMONOQ48890 Page 5 1.222 Sources Biphenyl Biphenyl is stored in horizontal tanks in the Biphenyl Area and pumped on demand into the Terphenyl Mix Tank. Ferric Chloride Received from the warehouse in 100 lb. kegs. Chlorine Received from tank cars and the chlorine plant. In 1969 the chlorine plant will be shut down and the entire supply will be from 44, 55 or 90 ton tank cars shipped into the plant. Liquid chlorine will be vaporized and trans ferred as a gas to the department area. Lime Hydrate Received from the warehouse in 50 lb. bags loaded on palettes. Santowax 11C" Received from the continuous biphenyl stills on demand through a transfer line. Santowax 11 R" Received from a 50,000 gallon storage tank, heated west of the HB40 department, on demand, through a transfer line. Santowax " R" is ob tained from the continuous Santowax still in the Biphenyl refining area. 1.23 Products and By-Products 1.231 Quality Considerations Aroclor 5460 has a color and softening point specification which because of the nature of the process gets out of control on occasion. Color is more of a problem than softening point. 1.232 Specifications Finished goods specifications, as listed below, are appended. 0726103 TOWOLDMONOQ48891 Page 6 Product Code 82616 82618 82619 82620 82622 82621 Date 3/11/66 3/11/66 3/11/66 3/11/66 3/11/66 3/15/66 Product Aroclor 1268 Aroclor 2 56 5 Aroclor 4465 Aroclor 5060 Aroclor 5460 Aroclor 5442 1,233 By-Products HCl gas is a by-product of the chlorination re action and can be absorbed in water to produce muriatic acid or sewered and neutralized with limestone. Residues from the distillation are drawn off to drums and sold as Montars or discarded. Listed below are data on the Montars. Montar No. Aroclor Softening Point Range Calcium Oxide 5 5460 6 4465 7 1268 8 5442 155-195C 135-190C 200 C 1.6% 2.0% The plant is considering the flakering of Montars in order to change the product form. Latest sales forecast, November 27, 1968, in dicates sales requirements for the solid Montars as follows for the year 1969: Montar 5 180,000 lbs Montar 5 crushed. dom. 400,000 lbs Montar 5 crushed, inter,. 80,000 lbs Montar 6 50,000 lbs 1.234 Packaging and Shipping Material 1268 2505 4465 5060 5460 5442 Container Weights Weight - lbs. Container 200 41 gal. fibre drum Form Flakes 50 and 500 5 and 40 gal. drums Solid 50 and 500 50 and 100 5, 40 and 55 gal. drums Solid paper bags Flakes 50 and 100 50 and 450 paper bags 5 and 40 gal. drums F1akes Solid 0726104 TOWOLDMONOQ48892 Page 7 1.24 Waste Streams Approximately 2200 gallons of Montar 5 will be produced daily with an approximate composition as follows: Chlorine Iron Calcium Oxide 57-59% 0.12% 1.6% Some of this material is sold, the remainder is put in drums and taken to the toxic dump. The plant has a project to pump these waste materials to Cleghorn's lake, a sump used for residue disposal. An additional 70,000 lbs. of HC1 gas will be produced daily from this new plant and will have to be absorbed and sewered at the acid plant. If additional absorption capacity is required, a separate project will be sub mitted. 1.25 Personnel. Property and Public Hazards Chlorine Gas Causes eye, skin and mucous membrane irritation. Maximum allowable concentration is 2 ppm. Concentra tions in the order of 15 ppm will cause throat irri tation. Cannister gas masks, Scott Air Paks or other similar equipment is required in strong concentra tions. Biphenyl A toxic organic chemical. Breathing fumes or vapors should be avoided. During processing the material is usually hot (100C or above) and can cause serious thermal burns in contact with the skin. Protective garments should be worn go aboid contact. Flash point of biphenyl is 235 F. Ferric Chloride Not toxic but presents an eye hazard. Normal pre cautions of wearing safety glasses should be followed. HC1 Gas Fumes are toxic and hazardous to teeth, skin, eyes and mucuous membranes. In strong concentrations, rubber protective equipment should be worn. Maximum allowable concentration of HC1 gas in air is 10 ppm. 0726105 TOWOLDMONOQ48893 Page 8 Santowax R Relatively non-toxic, however, the vapors are irritat ing to the bronchial tract. Prolonged breathing of vapors should be avoided. Material is generally hot (150C or above) and can cause serious thermal burns in contact with the skin. Crude Aroclors Crude Aroclors are hot since all are handled in Therminol heated jacketed lines. They can cause serious thermal burns in contact with the skin. Still Bottoms or Residue Fumes from still bottoms are toxic. They are ex tremely irritating to the mucous membranes, eyes and respiratory tract and should be avoided. They are hot (above 150C) and can cause serious thermal burns. Hydrated Lime Dust is irritating to the eyes and skin and any material on the skin should be washed off with water. 0726106 TOWOLDMONOQ48894 Page 9 1.3 Manufacturing Facilities 1.31 Description 1.311 General The following information is included in the Appendix of this report: Equipment Information Summary Process Flow Diagram Equipment Arrangement Study Building and Site Requirement Description of Work by Code of Accounts Preliminary Schedule Project Loss Prevention Report 1.312 Manufacturing Facilities A 2000 gallon mix tank for terphenyls with charge lines and supported on a 40,000 lb. hopper scale. Two 3100 gallon chlorination tanks with circulation pumps and heat removal systems consisting of two shell and tube heat exchangers and a Therminol surge tank and pump. An off-gas system consisting of heat exchanger and 2000 gallon storage tank to recover entrain ment losses from the chlorinator off gases with tailings pump. A 6500 gallon batch intermediate storage and blow tank with scrubber and transfer pump. A 7300 gallon still pot, 3500 gallon receiver with entrainment separator, still condenser and ex ternal gas fired heater with submerged centrifugal pump. A condenser control system consisting of two shell and tube heat exchangers and a Therminol surge tank and pump. A three-stage ejector with intercondenser, and aftercondenser and catch tank and sump tank. Additions to the present control room to provide space for additional instrumentation. A two-stage HC1 gas drowning system. A new freight elevator for Building 27. Additions to the present Therminol system. 072.6107 TOWOLDMON0048895 Page 10 1,32 Design Capacity Chlorination: Basis OST Rate Producing Aroclor 5060 6350 hrs./year 27,6 M lbs./year Distillation: Basis OST Rate Producing Aroclor 5460 6350 hrs./year 20,0 M lbs./year After these additions are complete, plant capacity will be as follows: Present Capacity New Capacity Total Capacity 9.6 M lbs./year 20.0 M lbs./year 29.6 M lbs./year Basis: OST 6350 hrs./year OAY 73% Based on the December 6, 1968 Sales Forecast, (HD to RY), excess capacity will be as follows: New Capacity Required Excess Capacity Excess Capacity 1970 29.6 M lbs./yr. 17,1 M lbs./yr. 12.5 M lbs./yr. 73 % 1973 29.6 M lbs./yr. 22.6 M lbs./yr. 7.0 M lbs./yr. 31 % 1.33 Flexibility Requirements Two complete and separate solid Aroclor systems will allow flexibility in our production runs. We will pro duce the larger volume requirement, Aroclor 5460 (82%) in the new units with the remaining solid Aroclors being produced in the smaller unit. Consideration will be given to incorporating the chlorinators into a continuous chlorination system at some future date. Both units will have the flexibility of being able to produce any of the solid Aroclor products. If fractionation is required to meet FDA standards, a separate distillation unit can be added to the existing system. 0726108 TOWOLDMONOQ48896 Page 11 1.34 Future Expansion The present expansion will occupy an 18 foot wide area directly to the north of Building 27. There is suf ficient area to the north of this expansion to provide for two additional chlorination-distillation systems. In the meantime, work should proceed toward developing a continuous chlorination system which long range should provide greater flexibility in labor and equipment. 1.35 Physical Appearance We propose to make the top roof deck concrete, a contin uation of the surface we installed to the west of Build ing 27 on project OEA 4-488. Additional weather protec tion will be provided in the form of a panel enclosure on the north wall of the structure. 1,36 Storage and Shipping Requirements No additional storage facilities are contemplated. Re cently completed project CEA 1430 provided a 5500 gallon day tank for finished solid Aroclors. In addition, a new 6900 lb./hr. flaker with a 5500 gallon flaker feed tank has also been installed in a separate flaking and packaging building. Raw material storage for Santowax R and Biphenyl are adequate. 0726109 TOWOLDMONOQ48897 Page 12 1.4 Utilities and Services 1.41 Utilities Summary The approximate utility requirements are as follows: For ejector, lbs./hr. 450 For tracer and tankheating, lbs./hr. 250 Power, Installed HP 245 Cooling Tower Water, GPM 600 Potable Water, GPM 50 Natural Gas, Cu.Ft./hr. 2000 1.42 Utilities Facilities No additional utility facilities are required for this project. 0726110 TOWOLDMONOQ48898 w *WMCimeMJMM|M ' > , W. O. KKUMM1U.CH WA** . ' *' RAW MATERIAL ^ SPECIFICATIPM- ieeuie FERRIC CHLORIDE AHHTOMDg GNHCkl PORMVk* *,`i4"is . FeCl, UHKRBWCIW _______ Hee_______ UWJ W UiLVIM '?..... ----------------- _ _ _ _ _ tstffs.. *.. maa. UNCLASSIFIED INFORMATION General Teuto (made only on rifuit) Prprty Appearance Specification Black powder or jrnnalna Asaay 97.0%, MU. - Soliatee 0.05%, Man. - Ferrous Salts Trace, Man. Solubility.' 10:10 ol water 10:10 of Formula SO alcohol Complete to allfiUly turbid. Max. Complete te alightly turbid, Man. WWFel>. 2b, 1957 .. STMUIK VeAd-r____ la bLa v) rsc 1*2.21 J.F.Q. MefiWdJWw^Pf! Ib-A 22-57* 120-m S-570-1 112-B ! *, .: V;- Htt '? *A, f, ` V . ?l $ ii 0726111 . -.{. vi v* Xy, , ... .J TOWOLDMONOQ48899 Monsanto Chemical Company ORGANIC CMEMIC44-S 0IVIS40N FINISHED PRODUCT SPECIFICATION product fTradt nairttl Biphenyl p roouc r (Oatmeal *mtt) Biphenyl CHEMICAL FORMULA MOOUCT COO* nuia MfTMOO lOSNTITY *AL COO* 135-000-03-09 Tret Technical T*P Technical tuPEPtCOCi PC* OP 7/6/65 cub10 | MCIAt-JO* NO. (AMRl* POM ANAL VM* 1 1 X 16 os* can Issued 5/5/61 Anniston Plant * By V. W. Klcaaer L Revised to add typ 43 mol t. 154.20 u*c Salas _ 4P cI n I .| I 1 Characteriatica Routine teata Appearance Crystallising Point* *C Color* Gardner Halts Vhite to pale yellow crystals 66.7 Min. 6 Mas. General Teat (detsnalned only on request) Biphenyl, X Napthalene, X 3 * Methylbiphenyl, X 4 * Kethylbiphenyi, X Unknown, X Diatillation Range, *C let drop - Dry Point Must Include 255*0 Tmical Values Whit, crystal. 68.6 1.5 99.9 0.001 0.05 0.02 <0.03 ThU specification for internal uee only 0726112 TOWOLDMON0048900 Monsanto FINISHED PRODUCT SPECIFICATION '"OLoOION 1 J. Moodv /a/ 2-1-66 1 ALC . ; . Ault /s/ 2-22-66 u r NLA t, 0(K*l6TlON ture . ' -S 7 ' RICILD INFORMATION i Mrance i iing Point, *C ho Terphenyl, % * \ 3 Terphenyl, 7 i .,i-) Terphenyl, % . rerphenyl, X l.enyl, 7. i Point, C M t ine, ppm . 1 :r, ppm MOOUCT Santovax C SlAnV aAmnniston 3-9-66 eaoOuCT coot 829.10 **1.kk c6bl 7795-050-99-009 1 y. utf Internal hcaiAh^H "" L. R. Stark /a/ 2-3-66 - M. McEven /s/ QUALITY CONTROL (Chft Chmilt> O. E. Dolln /./ 2-1-66 CHBUICAL fOKMVLl . ? -16 worn ANAtflii 2-1 Pint Cana LIMIT* **ue *v J. A. Llddlc 1-12-66 MCTMOO Brown, waxy solic 350 Min. **10 **50 **26 **14 **0.1 **375 2.0 (Typical) 2.0 " G-L 064 064 064 072 064 114 ribution of Isomers and quaterphenyls vary with operating condition. Limited data la available; therefore, the Haiti given are typical values i i o characteristics. r roduct is mainly used as a raw material for other finished products produced ir i on. i- pecification is for internal use only. MO i iV Routine Analysis, All others Analysed by request Only 0726113 TOWOLDMONOQ48901 Monsanto FINISHED PRODUCT SPECIFICATION POODOCT ION IXRL.CIG. Moodv /a/ 1-31-66 U. E. Ault />/ 2-22-66 oneiTioN PMOOUC T SScaAnnItovax R BAinfni inatrotnifMi aaooucf c'iol 826.02 liiiiii&i ^ Wll S.le J |OC r, 2 7793-000-11-009 A9viLI **!** l. R. St*rk // 2-3-66 - M. McEw.n /./ 2-22-66 OOAIvIT V CONTROL fChl*f ChumltO 0. E. Dolln // 1-25-66 CHtMICAk fORMUL* Mixed Terphenyls 2-12-62 t u.HACTLRI.TIC IAHRlI FOR ANlKIII 2 x 1 pint cent UtMTI wee v J. A. Llddle 1-11-66 MCTMOO UNRESTRICTED INFORMATION (R) Appearance (R) Color (liquid), NPA (R) Upper Hold Point, C (R) Lower Hold, *C RESTRICTED INFORMATION Distillation Range, C, 80% (Uncorrected) Ortho terphenyl, % Meta terphenyl, % Para terphenyl, % Quaterphenyls, 7. Yellow white noneryatalllne flaked solid 4.0 Max. 136 - 143 48-63 350 - 400 10.0 - Typical Value 54.0 - " " 27.0 - " " 9.0 - ' " G-l 128 129 129 h h ,utm. In. ^ // olhr'S .< d by rtque %i Only 07261X4 TOWOLDMONOQ48902 Monsanto MAVKMIAL COOK 826.38 LANT MATKMIAL Chlorine Gas UKIMK OKPTt. RAW MATERIAL SPECIFICATION Anniston 0atc errccnvc 8-31-66 84. 05. 27 m/mlKa See below AHODUCT ION APPROVALS AMKAneM R. G. Moody /./R. G. Moody - 8/11/66 MOCUItMINT L. R. Stark /s/L. R. Stark 8/29/66 Quality conthol Kmw CMPM) H. L. Phllllo. /./H. L. Phil1Id. - 8/15/66 O. E. Dolln /./O. E. Dolln - 8/10/66 QKNKNAL DKACAtPTtON CMKMICAL KOAMULA Greenish yellow gas tUPINtIDIf *KC* Ol Sept. 11 1957 C HAM AC T IRIIT1C IAMPLK worn AMALVI* jGLCsaniln^contalne LIMIT* UNRESTRICTED INFORMATION Materiel Supplied by Diamond Alkali Company Assay, (Vol. 1) Residual Gases (Vol. X) Moisture, ppm Non-volatile Matter, ppa 99.4 Min 0.5 Max. 40 Max. 40 Max. Material Supplled by Depta. 56, 57 (Anniston) Assay (Vol. X) H2 (Vol. X) C02 (Vol. X) CO (Vol. X) N2 (Vol. X) 02 (Vol. X) Mol. vt. 70.91 IMUIOIT I J. A. Llddle - 5/16/66 Typical MiTHoo Value 113 113 85.5 - 93.5 1.5 - 2.5 (3 Max.) 0.5 - 1.0 Nil 3.0 - 8.0 1.2 - 3.0 113 113 113 113 113 113 (A/ Aoviln# Anilrili, All 01hart Anatynj by ffumat mnly. 0726115 TOWOLDMONOQ48903 Monsanto MATCMIAi. COOC 38600 ULlllaltal OIHOyT6d.rate R AW MATERIAL SPECIFICATION Aimla ton 7-20-66 27. 28 WWXII* Alabaster Line Co. . .OOUCTION APPROVALS BillAMCM R. G. Moody /s/R. G. Moody 6/9/66 MOC U6IMINT *. F. Mueller /a/B. F. Mueller 7/13/66 0ua4.it v eoMTMOi. rcMef camum) H. L. Phllllsa /a/B. L. Phllllna 6/10/66 0. 1. DelIn /a/0. I. DelIn 6/8/66 CNCMCAL MPRIMM.A White fine povder Ca(0B)2 Sept. 11, 1957 CMAMACTtmanc UNRESTRICTED IMFORHATIOM AMAkC MOM ANAUVMt tz - 1 lb. can* Typical Analyala Mel. t. 74.10 TBuibit J. A. Uddla - 3/16/66 C.0 a> 73.00 m*o <x> 1.20 SlOj (I) 0.36 ai2o3 (X) 0.60 Fe203 (X) 0.30 Ignition Loot (X) 24.04 C*(OB)2 (X Calculated) 97.50<l> Screen Anelvala Through 200 neah (X) Through 325 aaah (X) 99.8 94.5 120 Basis of Specification*! Supplier* typical analyst* of product (5/23/66) (l) Ca<0B)j X - 100X - [>(0(X) + S102 (X) + AljOj (X) + F.jOj (if] <H) Rociln. Analytla, All othuf Amtv**4 Or hkmI ml?. 0726116 TOWOLDMONOQ48904 Monsanto FINISHED PRODUCT SPECIFICATION PNOOUCT ION W. E. Ault // 3-2-66 6CNCA4- DCMIFTION Mixture PftOOuCT lotFT. meouct 4661 127-S ull T A8T2164.1lo6os Sales 3-11-66 1040-340-04-11-16 -009 AFFftOV AL imfw--------------------------------------------------- L. R. Stark // 3-8-66 OUALITV CONTROL O. E. Dolln // 12-29-65 CMKMICAL. FORMULA MOU WT. uptpicoii ipici. of 4-25-61 C HAM AC 1 IP ll T (C IAUFLI FOA ANA|.VI* wsvsaav ~ 1 x 16 oz. Can or W.M. Bottle J. A. Liddle 11-30-65 UMT* MCTMOO UNRESTRICTED INFORMATION (R) Appearance and color Color. Gardner White to off-white powder 6 Max. (R) Hold Point, *C 150 - 170 (R) Acid No., mg KOH 0.05 Max. RESTRICTED INFORMATION Screen Test, X retained on No. 16 mesh 0.1 Hex. No. 20 mesh 10 Max. Specific Gravity @ 25/25*C., Pycnometer 1.804 - 1.811 Loss @ 163C., 7. 0.15 - 0.24 G-l 119 116 120 K R . i i in... > '.'. { 11 i tht r f Anoly ted by requt st Only -------------- 072611? TOWOLDMONOQ48905 Monsanto FINISHED PRODUCT SPECIFICATION PRODUCTION R. G. Moodv Is! 12-29-65 ULlt w. Ault III 3-2-66 Mixture PROOUCT Aroclor 2565 PRODUCT cook joPT. I27-S . BWMMreTivi 826,18 mu coos Salea__________ ____ _ 1040-390-04-009 approval nirrorrs----------------------------------------------------------------------------------------------------- L. R. Stark // 3-8-66 QUALITY CONTROL fCAiPl ChnmltO 3. E. Dolin hi 12-29-65 CMKMICAL FORMULA IU(MEDII P*C. OF 4-25-61 CHU4C1 KRIITiC UNRESTRICTED INFORMATION (R) Appearance and Color (R) Softening Point, *C (R) Acid No., mg KOH/g AMPlK FOR ANAivIII lUutD ------------------------------------------ 1 x 16 01. Cm or W.M. Bottle J. A. Ltddle 11-30-65 LIMIT* MKfHOO Black, brittle reeln 66 - 72 1.6 Hex. G-l 115 116 'R/ Routmt Anaiys h, All o(htrt Anolyted by rtquett Only 0726118 TOWOLDMONOQ48906 Monsanto OROANIC c NiMiC AL OlVItlON FINISHED PRODUCT SPECIFICATION ORODUCTION ULII W. E. Ault /./ 3-2-66 Mixture PRODUCT Aroclor 4465 Anniaton 3-11*66 imsv ali dur 1 826.19 ull Sale* |oFT. 127-S ...... 1040-430-04-11-16-009 L. R. Stark /a/ 3-8-66 QUALITY CONTROL {Chief ChtmltO 0. E. Dolln // 12-29-65 CMBMICAL FORMULA iupemioii setci, OF 4-25-61 CHARACTER,.T,C UNRESTRICTED INFORMATION (R) Appearance and Color (R) Color, NPA, Molten (R) Softening Point, *C Acid No., mg KOH/g IAMFLI FOR ANAkTM SIuiSTv---------------------------------------- L x 16 oil Can or W.M. Bottle J. A. Liddle 11-30-65 LIMIT* MCTHOO Clear, light yellow reain 2 Max. 60 - 66 0.05 Max. G-l G-4 115 116 R Routint -I r > i > s i >, 4 11 others A noly ted by re flue st Only 0726U9 TOWOLDMONOQ48907 Monsanto FINISHED PRODUCT SPECIFICATION R. G. Moodv /a/ I2r.lfl.-6i_ W. E, Ault /a/ 3-2-66 4 DESCRIPTION Mixture >*OL "TlUPCPAIDCt tPICt. OP 4-2S-6L UNRESTRICTED INFORMATION (R) Appearance and Color (R) Softening Point, *C (R) Acid No. mg KOH/g PRODUCT Aroclor 5060 SL*Nf Anniston PRODUCT COOC 826.20 SALII (Ul _______________ 1040-450-04-009 APPftOV A LI TuKIUTm----------------------------------------- L. R. Stark /./ 3-8-66___ QUALITY CONTROL (ChM ChemltO 0. E. Polio /a/ 12-29-65 Sales lofPT. 1 2 7-S AMPLt POD ANAl.r*l 1 x 16 oi. Cm or W.M. Botel* J. A. Liddie 11-30-65 LIMY* MCTMOO Black, brittle rasin 105 - 115 0.5 Max. G-l 115 116 R Ro{.r>r ir.jiyMs. ill oihtis Ariiilt led by request Only 0726120 TOWOLDMONOQ48908 Monsanto PflOOuCT Aroclor 5460 (High Soluble Grade) sun? HAMT <i6l nil |o*T. 127-S FINISHED PRODUCT SPECIFICATION I'M ODUC 1 ION SALE! Anniaton DATS IffbcVIVI 826.22 lltll CW( 3-11-66__________ 1040-480-04-009 APPIIOV ALI hltliUH ----------- L. R. Stark // 3-6-66 QUALITY CONTROL few*/ Chal*U S.lti -------------------- W. E. Ault /a/ 3-2-66__________ !--------------------- O. E. Doll. /./ 12-29-65-------------------------------------- Mixture 4-21-61 l4M*kl DM 4NAITIII Mule v 1 x 16 os. Can or W.M. Bottle J. A. Liddle 11-30-65 LIMIT* MCTMOO UNRESTRICTED INFORMATION (R) Appearance and Color Clear, yellow to amber brittle reein or flakee (R) Color, NPA, Molten 2 Max. (R) Softening Point, *C 98 - 105 (R) Solubility (25 g In 25 g. Acetone @ 25*C.) 3 hour, Min. Acid No., Mg KOH/gm. 0.05 Max. Chlorine, X 58.5 - 60.6 RESTRICTED INFORMATION Hydrolysis Stability, ppn Cl 300 Max. G-l G-4 115 117 116 093 092 RR An<ily ltd by ()nly 0726121 TOWOLDMONOQ48909 Monsanto FINISHED PRODUCT SPECIFICATION PNOOUCT ION R. G. Moodv /b/ 12-29-65 inn w. t. Ault // 3-2-66 t. C NlHlv DCECPIPTiOn Mixture PROOUCT Aroclor 5442 fTiW*" *^m ' PRODUCT COO* jotPT. . i 27-S___ ufl---------------------------- Anniston BYflnFFRV IVK 826J1 ' BALI*COOK Soles MfrM______________ 1040-470-06-009-----------------------------------------APPROVAL* umiwea------------------------------------------------------------------------ L. R. Stark // 3-11-66 DUALITY CONTROL fChUt ChmmtlO 0. E. Dolln // 12-29-65 CHtMlCAL PORMUI lUI'EKIEOEl IPtCI. OR 4-25-61 ': 64IUC T E1RI* TIC UNRESTRICTED INFORMATION (R) Appearance and Color (R) Color, NPA, Molten (R) Softening Point, eC Acid No., mg. KOH/g AMPLC POR ANALT*I* MfVSO 1 x 16 oa. Can or W.M. Bottli J. A. Llddle 11-30-65 LIMIT* MtTMOO Clear, yellow atlcky realn 2 Max. 46 - 52 0.05 Max. G-l G-4 115 116 0726122 TOWOLDMONOQ48910 CtNIRAi (. NC.lNfc LRING DEDARTMtNT EQUIPMENT INFORMATION SUMMARY / I/ /-r CIML QIJIl'Mt NT l( NT II K AT ION NUMIH ' /-// // nt sc inn ion o> 1 QUlPMENT ITEM .'/ v Si 7 E RAT INC. - MODEL. ETC v/"- - TS X CONSTRUCTION -A,.- , V,. IPERATlNC. WEIGHT POUNDSI REMARKS f. ESTIMATED if It .. 17. . < - A' sf.'f - %6:. w/. /r.-'. fi /- //V a* / '/! " 'fTt/H'/i* OF /-/o/-oo/ /-/'- -1 .. 7k>f/y / - iEH? /7*b XW / . ,,v- * V Tire V /-/cV-.V /)*- '/*r.^ , ,r> a'// / / Y v-,v <. /h , : . . -. . . / %6 '?/A Xae <uf &/jt // <5 8/a*>s~ fieri ~/2E/?r# / 4ooa. - nf C- - ^ - * r /V -v v./. , / - .A/y J Av /- 0724123 TOWOLDMONOQ48911 Cf.NlHAl ENGINEERING DEPARTMENT /. . EQUIPMENT INFORMATION SUMMARY 411 r" 1 t> 1 OUH'Ml NT me nt iru *i ion NUMUtK or sc mm ion o t OLHOMfNT IT EM SIZE BATING MODEL ETC M AT EBl AL Of CONSTRUCTION . ' r- I / ' ' 4 _'5' / IB EB AT l NO POUNOSI REM ABK 5 -V . /*' /- / i * i ESTIMATED PRICE 'Si 71,.,../), // * / r. V //VO- Ay' i . -/T hu - - */<' <- * ~tj O it >- /-/Or -On/ fia. '>/' / S//f- //*, /.' r rror A/ /-/Or -./--iK/A,/ v. /*4 /r.' / 5'v^r V (t>A* <s.,t w O'rr-< 470 , - t/A'*" r/uC: A S4 "67> C.cA**- /V \r. 71* 'At <t> Aav f.** <t\ r/Ai fy 6/'// , - T/y/A fit* 7' ' - ../ O, / ' o. /-/, ... / .. / z/o 6 /. //- - - /J, /}/ / A . // 0'L , . . /L ; `- -_ /; - A 0726124 TOWOLDMONOQ48912 CINIRAl ENGINEERING DEDARTMENT / EQUIPMENT INFORMATION SUMMARY /j V "O' *._y a .. ` y -,.rr / a - //./' POUNOS RCMARKS /A.. . , ?y ' *-r / k/*Z />.. . - / a/v- >' - ' LA.,- A zr> / <Vy- C*A' /''&<! Crt. Acr/'f %.-.rA Asit - \/K 'V*K Un,* /)r V 3rm W//+ A/- zh*> 7 ' A//Ajt 7?.v> > <5A' . ' , A rV ~y,r -A o // `"'fr/ ^47*; V Ac . v' /* s / .^>7- A /V rA- - -' kvV * y- y" ?*>*> V- A , .c 0726125 TOWOLDMONOQ48913 CENTRA! ENGINEERING DEPARTMENT EQUIPMENT INFORMATION SUMMARY / . Y GO n ` / (. 1. I) l Ollll*MF N T NOMUCI' Df SCRIPT ION OF e ouipment new /'/" Crt vv!.- QT v SI Z. RAT INC MODEL ETC / ?C0C 'G/t- MATERIA!. OF CONSTRUCTION A/V * K -C-rrS.. TPERATlNC WEIGHT pounos) HFMAMKS kj'v ' Y,v. `too--/ A'/-/ - " -VV,~ A-'* i ESTIMATED price i 1 >1 k /;.* - r' C 7 Ay >.- ' 4;o - tK.' A A... / A. /-//6 As/4--~ //oh/r- CiA/T/iv/v^u / /CO 6PM/So`Pi 0utrtL.&. /f\c, P/C ,v//VC: . /Izc*- /a. /-HO -DO* rfo70>C //.*<.. A^4`` / >a //ft: T V y* /'/// , CUrc* T/,' / 3 'a / i. Ct<Kt' ' Ac .1 * v4>//*;// rrrc A' -C/r k // < -y /!x . /'?' A v ' / . , . /?/' - . /t 0726126 TOWOLDMONOQ48914 CfNT/Ml f:NGINfERING DEdARTMn7 /.'"'V-.o EQUIPMENT INT0RMATION SUMMARY ,.r / / >/ , l I ll fQUITMtNl lilt NT 11 1C *1 ION NUMHlR /l A*- v .- cU.O A. or.sc ript ion oe EQUIPMENT ITEM QT V SI ZE. RATING MODE-. ETC T OF CONSTRUCTION >PRA7/NG WEIGHT .POUNDS) REMARK, j A A- A / A J-tiZ A/ r. /?,,,, l`K'fK-'' '<+*- / '5b />/>,-75''Hi /}< JO A-V 4 4 \ /-A/, // hi/.. - /%. 0\. , T/->> f /. .. / 7/y < A, t-n? TH ^n) i/t/C L she.i Z>' / /ZSob1 H* /hf< CooiH/> J&:> a a j/p~f 5m. f~Jt3 -<?,?/ /tft/a/i, 7Ha. *)//*: i. &><*' />>* 1-lH 7Hts.ro/*v,;. tv/i',/ / ZHP/s/6o fm / 3oo tZ/u. &Ki'C* ^TJCCi AZ'dAx^/'i/XH /-//./ n' a. /-'A./ /-/*/' Lr*/Tii // . a- v&hon: a; V/- f.'/i. / for'A* hi Jjf Tt. ` /a /)v; / j?y /''"//in 4 P" ' W //>'JL r/ &4.AO' yV A&rv>A? >fJ'k^roK /S6 > rrre //// yV ' h//o*i t~'*r\r* A* V //''/>/* Cof*- ( '**>) .. /itv a *.- &/r " *r.-.r, - ~ 9-BS/B s fv/z's,*'- a " 4//. . At.-* '-'Iv.- -> ,> As// A'' /? A A,, 072AIZJ TOWOLDMONOQ48915 CINTKAi [ NGlNf f RtNG DFDARTMENT I' /. . EQUIPMENT INFORMATION SUMMARY 7'`'`" . . < t: / .11.1 Ol.H'Ml NT NUMH[ II DESCRIPT ION C f EQUIPMENT ITEM MODEL ETC CONST RUCTION IPERATING .POUNDS! A //(' 7tfZr.rO/A/oK ^s-viAa, / />'}/. *['/ 737 - i / - t- ir// . 7c4\ :. . '*/ . ~v*. . ..........( 2P*l`A - ZO.^ -/ .. 1 . S % . I ^ ESTimTECj l Si V / - n~7 /-/!8 / //<? -c ' ^Wx/W.'////*'.is. A/'~> // C/tf.-'*C ft./Ar* i'Sr/J/.r( > A. / A-/ V ,v '<?$ '/</*S' 7>r/v. / 6/Wi/7s'tdh &> S/T A. < S4/- - for, - $A1f -* /V.. A/ 4rv-/, Wf Tor , r.. tf A/e* /vav sr/t. V Tcri Av. v` / . /- . />'' ' tf /- // J -Itf. v ' . (/ i.r/. / " dtv " Mr \-;Y * 7 T' / '/Mntf rr //. < ' V V/. y, A . - . Y/.. 7V- . 7:.. / ' ^7 y 4^ . / *>,;> / A-.A' . / Z9 .. > / l tLOf TH' V1 /> . 072612a TOWOLDMONOQ48916 CENTRA! 1. NCTINE ERING DEPARTMENT EQUIPMENT INFORMATION SUMMARY / i tot' OUlf'MC H ' lljf NT II 1C. A T ION NUMHHI //: / EQUIPMENT ITEM rff.-T" t 'A' 'A/s> ' - /*-. /- A. / Ifrc/^/h '/yo.* * >';`v f 7?>mk OT \ Si 2 E . RATING MODEL. ETC / 4iS AC -'r' /}t /-s': `c MATERiAl 0 1 CONST RuCTlON =M - 'A ... . 5rfr.- a, " k-`.r / SOO '7i'. cV// 4Z*,J *//,.-.TA 'RFRATING .POUNDSI REMARKS l U/r-,. r - ^/// ' 7, ' Z2: 6 \ *,"s - - V.- .3 r ' A A, Pit *" foe /*,'<. * v- y i K /'V/tt:*r /- n.. / /v.z~o t 7/V/\,rri/A-t J. fv/WS* / Sol 6,>'6f/i 'HD /\SI' r/*"*, /V SxU-)3 /iO!v Z/Zi&Xwciyvr*'' / 7Hrjn)'mi ^ <T *2 / ZnHr/,,, tr. /,4a? v ' OfA 6 , ^ 75 7 D&rj ?D"OM yiODT 7/l/<V />,fKr w>A, A /'O ' /r7~c.1 * ^ *&f' V /j/Ws rr~ /, /: / -... f />,-> - A-f-,' *^rpjjrtr ,v ----- _________ _____ 0726129 TOWOLDMONOQ48917 CINTRAL ENGINEERING DE DAR TME N T EQUIPMENT INFORMATION SUMMARY /:y. - \ 1 [II F Qllll-MC NT NUMUCN A/:.* />r:.uc DESCRiPT ION OF EQUIPMENT ITEM t/*:>> a; OT Y SIZE. RATING MOOEL ETC MATERIAl. OF CONSTRUCTION / ?CC- AC FA! YSa ooa- A- /or'-* ' ; y. - - X'rf, \l ' /A ; . ;",v .POUNDSI RLMA/IK5 ^ /^. T /'A' . y / 1 A 11 /`fo'orf /J.'K / /s/zs//*>- i> TFC A/ / -tur fy. dW `fj T/its'K / SOO /20HO6*/*O" i-nr f-t' / ft* .. ^V ` A , . ^T/y /. <f * v. v .................. / /2>~*>>,/31' /V. 3ri-S6 / sWy/i/- : * fr.&o A//3u/Fa*C 7_ V4*5 /*/?* /VTi>4 f``f/ MJ -48'/>** * Vsv^-i /*/?7/ /'/* 3 /#/ A/y* vr tfdJV./V' V TA x /O r-S: rv's >- FS: *" '' -* / ...... /ivc. //t'-- A A '"> ".y ^A*V .* 7?V - /, IVHI CHI V 0726130 TOWOLDMONOQ48918 ciNiRAi engineering DEdar7mcnt EQUIPMENT INFORMATION SUMMARY /. *' /- ' Vr * / -VC t (1 [OUll'MI I O [ N T I ri c * 1 NIIMHI'K So/** /-// 7 O/ ' .Pm , Of* Z3CJ/it.r: A-" 6'A// M*'r .--A r^-r fif'vl 6 / ,V 4* lPERATcS.' WEIGHT .POUNDS / / ? . /S /-/' `6 / /- /za Jtih Af, A/cfiiCri . < A 3co.o^*& Owe;,* rzt./. \/4ooo sroc W '$,/ x Ss'/Oi* Cfc t So % WI ^AtTM -* Sso ' Y~//\CO tv/T* /'/!<*- so, St/u. A/, S fit, P*,7n :/ CrPS d/S'f** /-/?/ Sr/n Pj~ S '/scr i/u. /Si "OS <r /<r Of/Co'p/ <k-WW. A//-%rf.r\ /p*` M y*ti. a : w a . Viet S*tp- / v l^va* />/+''' \Ja,s ' A/c, * .*" /ZOO' .F. 0V26J31 TOWOLDMONOQ48919 CIN7RAI iNGtNBERING DETRIMENT ,, .EQUIPMENT INFORMATION SUMMARY /, > / / /O - /S ( t U 1 OuipmE ni IDE NT 1 F ir *1 ION NUMH E t` /-/SO /-/Si Ilf SCRIPT ION or E QUIPME NT ITEM Cyci 3/y/ ^r/'/Vi'/y rc/ QT V SIZE RATING MODEL. ETC / l/A - CC //VO Cd*/E- ^'6 ' -* - 4'6 ` MATERIAL O' CONST BUCT 10 N C/W c v 6?rr* TPERATiNG POUNDS / REMARKS % X ESTIMATED PRICE 1 S> '/*t- W Sf/.U */,C . A, Vi*' //,t he/ - -t ?c if STU-. /Vo S /oA/i'Z/V^Ar. / .t bOOCCC A *. Stfdi. 'k/ut-Z. 460 /r Zo"&a < / LA>. C , / ,1 7r S/IEi./ * 6HUM.- 2 /uHC C 4ZOO *" '&A "/i at- v x/4f .-v : & XT Xl/wf O PaCI ow TV*/ &/? J*/Si// / m. r Ju6l~ /A/sn AfazrT r'/OO iS /~/32 /-/S 3 Srui M> S //cltvrn / C^/K TaC/vISC A -A//1' Hof.) !* . (*C*j }/C/ fU.- /*- / 3SOO 6AI ("/Hie# Crea /0'Pt>*/ZO"/i>6H /SO 'rt> f^CTU-/-~ // ')// /h: 3. - -/</ E^coo ,W/u/'S-\ ~ Xu& <y ///(l JA/St/*S'*Ait c bi/'rr ik/jr-ior <SfGOJ.ec k/SOrysl 2" , /* r .v /r/ti A>cc>}:>- '/.> /0,ui jAr-^z C'a\ a // /-/$ ~/r> / /*/;'>*. , A CvK 7a/A. r * / a?j/': o -<`/J v- ' `* /V/ 2 // f I l> Wl'l 6>< 1 Hi Leu !> NORMAL (ON'iNHOK ' tl MATERIAL UMlCMtVC# IS l'HVH /<* ! .f / . _________ 1 0726132 TOWOLDMONOQ48920 CENTRAl INGINEERING DC DAR TME NT EQUIPMENT INFORMATION SUMMARY /* `A y. IDCNTNiUfM1CftAfTRION /- /:*4 "'US / ' ` >A FQUIPMENT ITEM A/o S V/ror/c*/ QTV SIZMEODREALT.INETGC ZOO <$r /or '/si 7/ipS/ Z/j>V! /pr CMOANTSETRRIUACLTOIO'N Crzsj /- /3+ -On/ /lotUK &t<~ A/., Cwcoir-''H* si asp / ec/fp/ /&a- ///>. 9-2/-6 * IT 1 t 1/ "// /s /' SO - 6 / .POUNDS' i aJ Tr.- A/ /- /3/r .o?cm 7?)u< //>#// x/ SCO G/U Ok 6"i* Ct/t/ S27S yS/'/SrtP 'V CS sc** w'sct'*' WOvPn /P- _/S/jvPrt*. ~ s*ta A-/S6 Still A/n Sjcrrort / 6t?#rt*/rc a;W/TH /A!TOP. CoAJbtA/r. / A/je*i..z- , /&({.-.*.A-AJ rifrzK Zf*i&r A/?/\ A*:. :*'*. /AiZ "*/-/S: - Co/ Anth Cobb"* ./ /o ` cw-err' t;.\ t > ILL faot{TH'*/4 *r * a/ * S'Sz 'PZ Z&rJrtfS 0-i >?b * */o C A.> -/A>*/. - \M///1S7in*sv P3i0O<<w/.C/a*/*-- c-fi ___ 1 0726133 TOWOLDMONOQ48921 CENTRAL ENGINEERING DEDARTMENT &////. . ... /* *>*.* EQUIPMENT INFORMATION SUMMARY "r -r. C to t OUll'Mf Hi IDEM IF i. *1 ION NUMBER /- /3 7 r*,\-r . . 0/0 , OESCRlPT ION OF EQUIPMENT ITEM f/A/l./''V ACjLuCT" OTY Si 2 E RATING MODEL. ETC / SbQO MATERIAL OF CONSTRUCTION . t >*/ v 'PERATING WEIGHT .POUNDS) *r. / /% ' 7 //c-s / REMARKS % A * '* it''* y\j>/'.'>r PHu't 1 /- /?9 (!/ /' *.-7; 7/ K Mi**/*- P/Ta, rA / tZ'' S.//\ 'rt /!>,. S'**-A* Sumur A c A/ l/isj Ttictim'V'j- Sv/?6 Thu* / Soo S/L. ClHSoN C'f 4z"a/)*S/` />;<- *7 b/S/A/A/tTi C&U `K* /^fi, /* *. A/* / S<sHt`v + " J.CA - TZt'iBc /-/JO THZAjn) NIL fZfiT' /- /40-co/ rfc ir. , The A.AMNC l / /OOdPftl/rS'Hi; 'i)vtruc 7#*n A*c K-/o / 7/i#0//l> A`. 1 k /*. - /> 72TAC /V /-/// Tnc\ f </, ' i f'o - -r' b~J / 6(yco' JHesj. V T-r/ 2*\ . , -- - '" - ' ?/>*.<, C-rOf-L W 7Cr/' ' iV '' . v / V A" e'*~r ' ' /V v/,f A' . . - />/ ' >u:.*V"' /<* - 0726134 TOWOLDMONOQ48922 CENTRAL ENGINEERING DEDARTMENT EQUIPMENT INFORMATION SUMMARY / `"0 .. x.-r CEO E QUU-MENT IDENTir 1C A1 lON NUMBER /- /je OESCRIEM ION 0` E QUIPMENT 1 T EM ^jJTCTO'i 77*/VA' OTV SI ZE. RATING. MODEL. ETC MAT ERIAL Of CONSTRUCTION /:!?- *: -J / 'PERAT INC. POUNOS1 REMARKS / 7800 7% ' 0/> *4S /*/</> Tfio, 6 5A- STIC; /eao />>;?/>`A>*/r.!, *> at- &OC * 4^". /-/" - / EST IMATED ii* PRICE V /- Af.9 //.OJA'' IK. / .'s, fif - /V /-/4.^-orl /'forvfC , &Cv/i rotsL rb "< OvfA'Ai * Mr/-y^r ss'<o ' c 7y, r / SoAf/'dbofr.y /-/44 /-/4r /-/4r, %'*)/>aY SfA'fP * <V -r'ca. `V ' . Sc?'<*:/* -V* / '. */4. AC! fityeztfa- it 'ft tA ' / ' 4A ", 34' Oh/S.-'.-A. ' /7&Sk<$//*/: / f- * re:a :> /-M7 aV^V^,'// '.''CA 'st- t C\. / a>~ , 3-r -> . :i.vA Trr. rrre V kV 4f A/ i ioi "ti : N-NCn c [ n' ins >. 10 ac mlocitcd ll'IMl'ir, >11(11! * u L tO Bll M NORMA! CON T EN1 OR '**1 MATERIAL 0726135 TOWOLDMONOQ48923 CENTRAL ENGINEERING DETRIMENT EQUIPMENT INFORMATION SUMMARY I<DEL1>NTi:mOuelPAMT fIONNT NUMBER A/V * DESCRIPTION OF EQUIPMENT ITEM QT V SI ZE. RAT iNG MODEL ETC f/rA/7EK / MATERIAL OF CONSTRUCTION T > A - / /-/c -6 / .POUNDSI REMARKS /.y ... A-T id i ESTIMATED PRICE ( SI V 7f/'/Cn;-f* . hsis*. /' 7/ja/K / /'/ro /44 OfrJr > /'r.r* /- /Sr, 77tc<C/>, /s'/ />.-r / CjCa, 7K,;vS'/i-- /-/So-or,J S'fare*a, , 7//C* * 7A/ - / <ryi /oz ` rpa foc'C*? //&tvy' 2X>7y t/s/gr/Sl Szrs/. A/.'.V/V A ^ 4/ fiswf./ 4 rrre A/ /-/s/ /2C * /-/St-t/ / /&' firmer / 24*Of 364 S'* *ns- /A*# M /, r: . - .... r- / +&SS S.'fif T/rc V V . /. .i 0726136 TOWOLDMONOQ48924 CENTRAL. CNGINEERING DEARTMENT EQUIPMENT INFORMATION SUMMARY cr. D t QlllPMf NT IDENTlFIC A1 ION NUMBER 77 <s< 3CC0 V ` s*' . r- / /-LL-C f 'PEBATlNC WEIGHT .POUNDS' 3 77-Cr^ V*r~ < which EVE" UHMVItn 072613? TOWOLDMONOQ48925 Aoa/h/ia /icu. Afr 5A*/rowAx 'A' C/e H/4 230-2 /saa/c Cmu>*- Ae C/s /4Z-Z Ghloa/a/s C/k 70'? A/a //yoAOes# Me Zf'O z-o &vt>* Sb60 CmM Z/C/ 3-~ 6** Afo#)* 74./ S4SO %/hd/e *74-e /fa/TAA. S' 7AU./A/6S TStal ***/&* Sm /<** 0,/t/SX <&`/4`A'/6 <5P/1- /lA* ttscos/rr- CA Tt,,r K /kesss/te-Arri / woo Z- at //Zoo /s /330 9-4 /o /iO / 3 4 sT 4 7 6 9 /O // //ZOO //ZOO /r /S /s 32400 as- SO 924oo 2S 3SCO 3Soo 7000 3St>0 3b0 /OO /OO ZOO /OO /OO zsjoo Y742S 548SG zso I74ZS 94S ft* 7SS 94S 74S 9fS >2/60 36CCO Z/99S 42/00 26/6S /Z/60 96C00 &f?s f-r /4S0 2/60 /4SO 100800 33/680 4112St /coioo 33/080 /oo /ZS 2SO /2S /oo /z-r zso /zs /O as /oo ze m*. tyL /<? / 8-4 rjs^n /z 2.6 A90 /60 /s~ 2SO 2S0 MO /s zso / / A3S /3S /as / / /-3S /3S 0726138 TOWOLDMONOQ48926 Ag" /3 >7.... AT /6 /7 /y 20 2/ 22 23 24 ~~ '"1 /r 30 30 ~2S 3&0 /oo"| <*0 ;**? ao 5590 11_____ 300 I_____ ; . _____ ! ir 2^X3 S/BOO Tmzs 300 4oo "" 57f/0 SO 37900 /OO 37600 37600 1 (3?oo /*#> aaw WW 300 8oo S/630 * 379SQ so 37900 *f330 /oo Titoo 37800 ! 1 1 > *5 ! 1V 1 <o : I4l I'S < sj * O* l. 2/60 4/eo 33/490 _____ ! 462/60 Z?/0 //7S0 _____ j izJ zd25P | ZSO ! 4& 3030 //OO 3060 3020 4tecax> /4S0 /ZS -j /zr Wd /2-0 /z-s 13 m, /IS /ZS |5 *S 1!J 5 n'J^ >5 1Ij * s !] 0 <2 69-9b/\ 'Jo mh ft WM WM |H I eja 2SO \7s j /oo | zoo [Tar / [TjF\/-3S / '\t /zo 4o ggr w /60 370 033 ,003 .0/97 / /zo /so /60 <49? / /ZO 760 / 6 1 II 1i* S!4 H & 1 1 iVf1 /)pp 8 0726139 TOWOLDMONOQ48927 ^7>-i a A Stress Cfo.Q*/AZA/Tkt dru* 0MGO Sh*rOM/4X 77** -/V-CS O-SO /soo /# icoo * 3e * SstfiT r 7Sr/9t. AOO ($^> /OO ?.oo o-so / OO #4s /font/ Snu. Crtue 'TiM&e5ru (^> o-so /far t/fi Oanu. Otprr @> @> 2-00 &-SO /OO TbrAt- /2-00ZZKS 0726140 TOWOLDMONOQ48928 fastML Ct/*c/rY* tes/ffirc// * Afrw/y/r * 6Ae4*r/<t #**. fO.OOO.CoO r 37,860/43/8*1*#* C#e &trt#//*&>* 3 * S3J~0#A3 r-/vsa SO oo SO 00 007/X3 I/~M>S?\ f/UAL fidAij/tura ti/iPA*/ y CntrtAL.&&##/** &r#isrtor#r Sr^oo/s, CKSAA/tC | /ufUHTOtJ /iAMT Atoce&s //<*/ i/A*K#t B/KiKXAU.4$ua/c#- JcifD /fiQCU>A kPA*3/Q# &?AW# ~W--------- Are fSYmico Ho-tf /}&p 0726141 TOWOLDMONOQ48929 N 5CAU*. r mo'-o" 0726142 TOWOLDMONOQ48930 1 p,\Sl=_____ 3( )' fiROUND L&VfcL (E1V. *741-rt'} ScfcLR t`lsl0`-o" jWfKWT ARRAv*t He<->r yrvo gouo ARPCkRR. g*P.KM'M CEA.-J.oeo 5ca*-e- r=)o-o" !3* H<P.dl>#4'n**v ^ '/'->Ai 'Wf 1 -fz /ypp c 0726143 TOWOLDMONOQ48931 N Third Le.VE.1 SCAUt I"*! O'-C/' 0726144 TOWOLDMONOQ48932 >V -c ai>\P.#t*r ARRAMggHBtJT 5TTJP/ SOLID A.ROCLOI8. EyfAf-^lOKJ C&S-14&0 SOJLt I" - *o'-o" Im *VlA rtet 1 of JL 0726145 TOWOLDMONOQ48933 Appendix D Building and Site Requirement A. Building Size Number of Floors - Three (includes ground and roof level) Area per floor - 15D0 sq/ft. Bay Size - 20' X 18' - 2 required - 30' X 18' - 1 required - 12' X 18' - 1 required B. Type of Construction 1. Structure - Open steel structure. Roof to be reinforced concrete. North wall to be enclosed with Monsanto Lustra span panels or equal. Second level floor to be grating. Finish on steel to be coating standard No. 502 or equal. One stair at the east end of the structure. 2. Rooms Control room ceiling will be acoustical tile. Control room floor will be terrazzo to conform to existing floor. Walls will be painted concrete block. 3. Personnel Service Facilities None required. 4. Elevators A freight elevator for moving bags of lime and rework to the operating floor is required. Capacity - 5000 lbs. Only one floor is served. 5. Heating and Ventilating None required. C. Electrical There are no flammable materials handled in the immediate oper ating area. Classification is water resistant. Normal grounding requirements. Lighting requirements - Allow sufficient lighting for opera tions at the ground, operating and roof level. 0726146 TOWOLDMONOQ48934 Provide two welding receptacles at each operating level, six required. Provide two small tool outlet receptacles at each operating level, six required. D. Maintenance Provisions The coil in the furnace, Item 1-128, has to be accessible for repair. The submerged pump. Item 1-134, in the still pot. Item 1-129, must be installed so that it is readily removable. E. Drainage No spacial materials are required for drainage. Drainage ditches will be constructed in the ground level concrete pad and a curb installed around three sides of the entire pad. F. Communications None required. G. Safety No safety showers or eye wash fountains are required. No explosion barricades are required. No blow out panels are required. H. Fire Protection No sprinkler systems are required. No fire wall, fire hose stations, fire alarms, or foam systems are required. No building steel fireproofing is required. I. Walks and Roads None required. J. Railroads None required. K. Parking Lots None required. L. Fences None required. M. Dock Facilities 072A147 None required. TOWOLDMONOQ48935 N. Facilities to be Relocated The control room wi11 be expanded and the existing chlorinator panel will be relocated into this new control roomTaMition. O. Grading and Excavation The area to the north of Building 27 is a filled area and good soil is available at 12 to 15 feet from the surface. P. Site Covering Rock covering in the areas around the site location. 0726146 TOWOLDMONOQ48936 Appendix E Solid Aroclor Expansion Scope of Work 01 - Equipment See Equipment Information Summary 02 - Instrument Items See Instrument List and Summary 03 - Setting and Testing Equipment Area accessible for truck and train unloading. High lift can be used to set larger units. The new elevator will be in stalled in Building 27. 04 - Setting and Testing Instruments An addition to the present control room will be required to make space available for setting instruments. The new addi tion will be 20 ft. X 30 ft. 05 - Piling None required. 06 - Excavation For operating floor 100 ft. X 22 ft. X 1 ft. 2200 cu.ft. For elevator pit 360 cu.ft. 6 ft. X 10 ft. X 6 ft For structural piers 7700 cu.ft Mfg. Area 7 piers X 8 ft. X 8 ft. X 12 ft. 5400 - 5400 Control Room 3 piers X 8 ft. X 8 ft. X 12 ft. * 2300 Backfill required 5000 cu.ft. Remove spoil - Sheet piling may be required for shoring. 0726149 TOWOLDMONOQ48937 07 - Foundations For Structural Steel 10 pads X 6 ft. square X 1.2 deep with 12 ft. column 1.5 ft. square 700 cu.ft. Floor Slab - Reinforced Concrete 1100 cu.ft. 24 ft. X 90 ft. X 6" thick Equipment Pads 120 cu.ft. 10 items X 6" Thick X 6 ft, X 4 ft. Concrete Basin Within Floor Slab for drainage 450 cu.ft. 2 ft. wide X 1-1/2 ft. deep X 6" thick X 90 ft. long, 2 required 08 - SuoDorts, Platforms and Structures Equipment Supports 55 tons Grating Requirement 2000 sq.ft. Handrails 400 ft. Toeplate 400 ft. Misc. Structural Supports 8 tons Stair Requirement One complete stairway for two levels Control Room Building Frame 10 tons Control Room Floor 300 cu.ft. 30 ft. X 20 ft. X 6*' thick 09 - Oth.r Building items Floor Covering for Control Room 600 sq.ft. 30 ft. X 20 ft. terrazzo to conform to existing floor Acoustical Ceiling for Control Room 600 sq.ft. Windows for control Room - Four Units 5 ft. x 4 ft. Doors for Control Room - Two Hollow Steel Units 3 ft. X 7 ft. 0726150 TOWOLDMON0048938 10 - Sprinklers None required. 11 PiEjna Item Service Material Size 1-101 Sant R C.S. 2" X3" Biphenyl C.S. 2'' Vent C.S. 3"X4" To It.103 Misc. C.S. C.S. 3" X4" 3" X4" Misc. C.S. 2"X3" Misc. C.S. 2"X3" Therm.Ret. Steam Cond. C.S. C.S. C.S. 1" 1*5" 1" Rmks. Jacketed Traced Jacketed Jacketed Jacketed Hose Jacketed Hose Jacketed Hose - Length 75 ft. 75 ft. 35 ft. 30 ft. 2 ft. 2 ft. 2 ft. 50 ft. 40 ft . 40 ft. Insul. Valves 1" 2 - Jctd, 1" 2 - CD3 1" 1 - Jctd, Vent 1" i - Jctd, -- - - 1" 3 - FA37 1" 1" - 1-103 Chlor. Charge C.S. 3" X4" Jacketed 100 ft. 1*5" 1 - Jctd, 1-104 Relief C.S. 2" Relief C.S. 3" Chlorine C.S. 3" To It. 105 C.S. 3" X4" Jkt. S.. S.Inner Traced - Jacketed 50 ft. 50 ft. 60 ft. 30 ft. - 1 - CA46 -- 4 - DE411 2" 1 Jctd, 1-105 To It. C..S.Jkt. 3"X4" 106 S., S. Inner To It. 125 C.S. 3"X4" Sample C.S. 2"X3" Jacketed Jacketed Jacketed 50 ft. 25 ft. 30 ft. 1-106 To It. C..S.Jkt. 3 " X4 " 104 S.. S.inner To It. 116 C.S. 4" Jacketed - 25 ft. 25 ft. 2" 2 - Jctd 2" 1 - Jctd 2" 1 - Jctd 2" No 2 - FA42 0726151 TOWOLDMONOQ48939 Item Service Material Size Rmks Length Insul. Valves 1-107 To It. 108 c.s.. 4" 2 tracers 50 ft. 1*5" i - CA46 To HC1 Line C.S.. 4" 2 tracers 50 ft. 1*5" 2 - CA46 To It. 109 C.S.. 4" 2 tracers 30 ft. 1*5" 1 - CA46 1-108 To It. 113 c.s,. 3" - 20 ft. 1" - To It. 109 c.s,. 4" 2 tracers 15 ft. 1*5" - Drain c.s.. 1" - 20 ft. i - FA42 1-109 Vent Relief 200 psig steam In. Cond. Out To It. 110 c.s,. c.s,. c.s,. c.s . c.s . 2"X3" Jacketed 2" - 1" 25 ft. 25 ft. 50 ft. 1" - 50 ft. 2" X3" Jacketed 30 ft. 1*5" - 1*5" 1*5" 2" i _ Jctd, - 2 - FA37 2 - FA37 i - Jctd 1-110 To It. 101 1-111 Vent Therm.In Therm.Out To It. 112 c.s,. c.s . c.s . c.s . c.s . 2" X3" Jacketed 70 ft. 2" 2" _ 20 ft. _ 1*5" - 40 ft. 1*5" 1*5" - 40 ft. 1*5" 3" - 25 ft. 1" 2 - Jctd _ 2 - FA37 2 - FA37 i - FA4 2 1-112 To It. 108 1-113 To It. Ill c.s . 3" c.s . 3" - 50 ft. 1" i - FA42 - 50 ft. 1" - 1-117 Relief Relief Chlorine To It.118 c.s . 2" Traced c.s . 3" - c.s . 3" - c.s. Jkt.3" X4" s.s.:Inner - 50 ft. 50 ft. 100 ft. 30 ft. - - 2" i - CA46 - 4 - DE41I i - Jctd 0726152 TOWOLDMONOQ48940 Item Service Material Size Rmks. 1-118 To It. 119 C.S.Jkt. 3" X4" Jacketed S.S.Inner To It. 123 C.S. 3"X4" Jacketed Sample C.S. 2"X3" Jacketed Length 50 ft. 25 ft. 30 ft. Insul. Valves. 2" 2 - Jctd 2" 1 - jctd 2" 1 - Jctd 1-119 To It. C..S. Jdt. 117 S.. S.Inner To It. 123 C.S. 3"X4" Jacketed 4" - 25 ft. 25 ft. 2" . NO 2 - FA42 1-120 TO It. 108 To HC1 Line C.S. C.S. 4" 2 Tracers 50 ft. 4" 2 Tracers 50 ft. IV 1 _ CA46 -1*5" 2 CA46 1-121 Vent To It. 122 Steam In Steam Out C.S. C.S. C.S. C.S. 4" 4" 1*5" 1*5" Traced - 30 ft . 30 ft. 50 ft. 50 ft. 1-122 To It. 119 To It. 123 C.S. C.S. 4" 4" Traced 70 ft. Traced 30 ft. 1-123 To It. 121 TW In TW Out C.S. C.S. C.S. 4" Traced 40 ft . 6", 3" - 50 ft. 6",3" - 50 ft. -No 2 - FA42 i" i" - NO 3 _ FA42 NO 1 - FA42 No 1 _ FA42 - 1 - EA46 - 1 - EA46 1-114 Vent C.S. 4" - 30 ft. to It. 115 C.S. 4" Traced 30 ft. Steam In C.S. 1*5" - 50 ft. Steam In C.S. IV - 50 ft. 1-115 To It. 106 To It. 116 C.S. C.S. 4" 4" Traced Traced 70 ft. 30 ft. -- NO 2 _ FA4 2 1" - i" - NO 3 __ FA42 NO 1 - FA4 2 0726153 TOWOLDMONOQ48941 Item Service 1-116 TO It. 114 TW In TW Out Material C.S. C.S. C.S. Size 4" 6", 3" 6" 3" Rmks. Traced - Length Insul. Valves 40 ft. No 1 - FA4 2 50 ft. 50 ft. - 1 - EA46 1 - EA46 1-124 To It. 125 C.S. 2" - 60 ft. - - 1-125 Steam In C.S. IV - 60 ft. 2 2 - FA37 Steam Out C.S. IV - 60 ft. 2 2 - FA37 Vent Saran Lined Steel 6" Traced 50 ft. No To It. 126 C.S. 3" X4" Jacketed 30 ft. 2 2 - Jctd. 1-126 To It. 129 1-127 Vent Drain 1-128 To It. 129 Gas In C.S. 3"X4" Jacketed 75 ft. 2 2 - Jctd. P.E. Saran Lined Steel 6" 3" _ 50 ft. _ 50 ft. - C.S. 3"X4" Jacketed 30 ft. 2" 2 - Jctd. C.S. IV - 50 ft. " 2 - CD3 1-129 To It. C.S. 18" - - 130 2" - To It. 134 C.S. 3" X4" Jacketed 40 ft. 2" 2 - Jctd. 1-130 To It. C.S. 16" - 30 ft. 2" - 131 To It. 129 C.S. 2" X3" Jacketed 10 ft. 2" Site Glass To It. 141 C.S. 2" - 30 ft. 1-131 To It. 132 C.S. 3"X4" Jacketed 20 ft. 2" 2 - Jctd. Site Glass To It, 141 C.S. 2" - 40 ft. - 2 - FA37 0726154 TOWOLDMONOQ48942 Item Service Material 1-132 Vent C.S. Relief C.S. To It. 135 C.S. To It. 133 C.S. Steam In C.S. Steam Out C.S. Size Rmks. 3"X4" Jacketed 4" - 3"X4" Jacketed 3" X4" Jacketed 1*5" - 1*5" - Length 30 ft. 30 ft. 40 ft. 30 ft. 60 ft. 60 ft. Insul. 2" 2" 2" 211 2" Valves 1 - Jctd. 2 - Jctd. 2 - Jctd. 2 - FA37 2 - FA37 1-133 To It. 137 - 1-134 To It. 128 - 3"X4" Jacketed 110 ft. 2" 2 - Jctd, 3"X4" Jacketed 40 ft. 2" 2 - Jctd. 1-135 To It. 136 Steam In Steam Out Water In Water Out - - 3"X4" Jacketed 30 ft. 2" 2 - Jctd. 1" - 30 ft. 1" - 1" - 50 ft. 1" - 1" - 50 ft. 1" - 1" - 50 ft. 1" - 1-136 Steam In C.S. Water In C.S. Water Out C.S. Aftercond. Water Out C.S. Intercond. Vent C.S. 2" 2" 2" 2" 3" _ 30 ft. 1*5" - - 30 ft. - - - 40 ft. - - - 40 ft. " - - 20 ft. - - 1-139 Steam In C.S. 1*5" - 50 ft. - - Steam Out C.S. 1*5" - 50 ft. - - Vent C.S. 3" - 20 ft. - - To It. 140 C.S. 2" - 30 ft. 1" 2 - FA42 1-140 To It. 131 1-141 To It. 139 C.S. C.S. 2" 2" - 70 ft. - 2 - FA42 - 50 ft. 1" - 072.6155 TOWOLDMONOQ48943 Item Service Material Misc. Therm 14 Conn. In C.S. Therm 14 Conn. Out c.s. Therm C.S. Sire IV 1*5" 6" Rmks. - Length Insul. Valves 500 ft. IV 30 - FA37 ** 500 ft. IV 30 - FA37 - 500 ft. - 4 - FA37 12 - Ductwork A 6 ft. X 6 ft. cabinet will be required for housing drums for draw-off of residue product for still pot. 13 - Electrical Motors to be installed and wired: Number Horsepower 12 55 1 7*s 2 10 3 15 2 20 1 25 1 30 1 50 Allow for remote pushbuttons and alarms for 10 motors. Lighting required in operating area: Ground Area, Operating Area, Roof Area, 18 ft. X 18 ft. X 18 ft. X 82 ft. 82 ft. 82 ft. 1476 ft2 1476 ft2 1476 ft2 14 - Site Preparation None required. 15 - Sewers 1. 50 ft. of 4" permanite sewer pipe with one tie-in to exist ing 8" sewer which runs west of Building 27. 2. 150 ft. of 304 S.S. guttering around the top of the new structure with 3-4" downspouts, each 30 ft. long 0726156 TOWOLDMONOQ48944 16 - Underground Mains None required. 17 - Yards. Roads and Fencing None required. 18 - Railroads None required. 19 - Insulation Piping - Refer to Code 11 Equipment - As below - material Standard #100 Weatherproof, Std. #65 Item 1-101 1-104 1-107 1-109 1-111 1-117 1-120 1-125 1-129 1-130 1-132 1-139 10 Pumps Area 250 ft2 200 ft2 50 ft2 250 ft2 80 ft2 200 ft2 50 ft2 550 ft2 550 ft2 150 ft2 350 ft2 80 ft2 Thickness 2" 2" i" 2" iv 2" 1" 2" 4" 3" 2" IV 2" 20 - Painting Coating Standard #502, Epoxy System. All uninsulated piping, air, water, gas. Supports for Items 106, 113, 116, 119, 123, 128, 141, 142, 132, 135. 0726157 TOWOLDMON0048945 21 - Walls, fasonrv, Roos and Roofing Concrete roof deck for mfg. area - reinforced concrete, 20 ft. X 90 ft. X 5" thick Concrete roof for control room - reinforced concrete, 20 ft. X 35 ft. X 5" thick Concrete wall for control room - concrete block, 3 walls, total feet - 70 ft. X 15 ft. high Concrete enclosure for elevator - concrete block, 4 walls, total feet - 30 ft. X 25 ft. high Built up 4-ply roof for control room, 20 ft. X 35 ft. North wall of mfg. structure will have Monsanto Lustra Span panels for a distance of 80 ft. and height of 12 ft. in each level. 750 cu.ft. 290 cu.ft. 1050 sq.ft. 750 sq.ft. 700 sq.ft. 1920 sq.ft. 90 - Dismantling 1. North wall of Building 27, approximately 1500 sq. ft. of brick wall. 2. South wall of present control room, 450 sq.ft, of concrete block wall. 3. Shed to south of present control room, approximately 600 sq.ft, of transite roof and steel platforms inside shed. 4. Biphenyl heater on Still No. 1. This is a unit heater in the shed. 92 - Repairs Expense Replace existing head on Item 535. This is a 2000 gallon vessel and requires a new 78" O.D. carbon steel head. 93 - Relocation and Modification Expense 1. Remove and relocate Item 205, a 14` dia. X 10' high storage tank with coil and agitator. 2. Remove and relocate stairway to the north of Building 27. 3. Remove and relocate 10 ton stand-up tube air-conditioner which is now in the south section of the control room. 4. Remove and relocate a 20 ft. chlorinator panel from its existing position in the present control room to the new control room. 5. Remove the present 1268 flaker (24" X 48" unit) and replace with a new unit. This unit will be relocated to an area just east of the present flaker. 0726158 TOWOLDMONOQ48946 APPENDIX E - Amendment No. 1 Scope of Work - CEA 2080 07 - Foundations For Elevator Pit (Reinforced Concrete) 150 cu. ft Supports, Platforms and Structures Equipment Support For Item 152 6 tons Grating Requirement For Item 152 225 sq.ft Handrails 60 ft. Toeplate 60 ft. Stair Requirement One Stairway For One Level 11 - Piping Item 1-152 Service Material Size Charge c.s. 3,,X4" Charge c.s. 2" X3" Therminol c.s. 1*5" Vent c.s. 3"X4" Overflow c.s. 3"X4" Outlet c.s. 2" X3" Rmks. Length Insul. Valves Jacketed 125 Ft. 2" 1 - Jctd Jacketed 125 Ft. 2" 1 - Jctd - 200 Ft. IV 2 - FA5 Jacketed 30 Ft. - - Jacketed 30 Ft. 1*5" - Jacketed 50 Ft. 1*5" 1 - Jctd 12 - Ductwork A 6 ft. X 8 ft. X 10 ft. hopper will be required under the new flaker. 13 - Electrical Use PVC coated conduit. 19 - Insulation Item 1-152 Area 320 ft2 Thickness 2" 90 - Dismantling 2 A section of floor in Building 27 - Area 400 ft for 1268 flaker. 072A159 TOWOLDMONOQ48947 92 - Repairs Expense 5. Repair or replace section of floor at new 1268 flaker. 93 - Relocation and Modification Expense Remove Item (5) from original scope and replace with the following: 5. Relocate 18" I beam to south of control room. This beam is 40 ft. long and will be moved south approximately one foot. 6. Relocate 2 - 6" IPS tower water lines to south of control room - Total feet = 100. 7. Relocate miscellaneous 2" IPS pipe to south of control room - Total feet = 100. 0726160 TOWOLDMONOQ48948 2 ae \ r*T /a /7 2 4 _ ~roZ2Z T*4Tt Y 1 /i / \____ LrH ^--Li--J\2--iF^--` f--L P<CO(S.S $U/P. _TTUC T. Or/i/rv _ fz/AO7J>Kl P/ P/UOr /A/suiAr>OAj /*J3 T*. c*c. < - p 1 _JV a/6>! < 6*J < <i U/A. A* (Qua **Cri A*J/a. ?^r !--<s ?------ \ / >- 1 i >-- i i X if li i i 11 \ 1 ii 2tevt iLOA Pt/* X nAuUa/t HAJT 06.K-I &J \ \ oa TAiK 1 ~T7 5 (L_ 1 / V\ Pac '/JA.% dU/A Mu T 1 1, 1 1i j A ttc U. </ A *<rV VU PATA Pe. 'tecA fSk L/V6 i s. AP CP. AAAI >s L Tcctr Y i r sret* : r<ri/v '1 1 1 y / \ J? TUCl 1 \rftu C.T. rr rqX ------( )z>*. I ,c i II P, STttL ------ \ / 4$l"i1^r\2S\'tiSt/ P i rcoo* n ItA rA/. >r L. \ "1Au i Ptu /------ i ^ rs Co a/STi UCT \f&r AJ. Att \j3l_ ycr. r OTA/S \e.a 1 l 1j 1 U- /UA -< \P/P. y PC* 2 WAS/ ----- ^ / 1 ?/e.cCr iouu ice. Joe. 1 cy <aIlo La / Qlac -< X"1 >-A *S >-- ?-- \ ^ 1 1 11 .Mol L t 0, '/ASj 'cffL, \ ^ A P/p/. U& 3 1 11 l1 1 < J P/o /AJeTr I1^ 1 1 .Pu. 1| 11 i / P \f/)a1 \ //V IT/Zb MtJ r >> -S'** Po etcPa S. / a. i 1 -X it ---< ^l- / }.S /A srte /M. jr m e'piA/ '/je-r 1 .hci ff l1 our LC rrr/Ai sre.. Oust fOA DC . , 1)1/ L < )-- >=t=_j --<1 i1 1 > i1 1 ~<L_ _1_ s L& CTZt AL teste A/* / 'u&C SAJa '------- Is 1 P as. ^ > .ll/STA 'l I V ilc TtC l n vJG'S. f 1 fA.C C. f P Mvv l/JCr \ ------<s _ 0726161 TOWOLDMONOQ48949 0726162 TOWOLDMONOQ48950 Monsanto General Offices - St. Louis January 24, 1969 Project Loss Prevention Report 69-7 CEA 2080 Mr. R. S. Yates cc R. E. Howard G. O. Hunt P. K. Ward - Anniston S&PP Project File S&PP Location File COPIES TO THOSE PRESENT R. J. Green W. B. Howard R. M. Kountz W. E. Voss - Anniston R. S. Yates DATE AND PLACE OF MEETING Missouri. January 23, 1969, Creve Coeur, CEA 2080 Alabama. Expand Solid Arochlors, Anniston Plant, Anniston, This project is increasing the plant capacity for manufacture of solid arochlors from 9.6 to 29.6M ppy. The project capital is approximately $1.03M. Completion target is December 15, 1969. PERSONNEL 1. Chlorinated Biphenyl Content of Product An overall project objective is to minimize chlorinated biphenyl content in the solid arochlor 5460. This is needed for FDA approval of the material, since it is used in hot- melt adhesives in food packaging. It is also used in plasticizers. 2. Elevator It is planned to install an elevator to handle both freight and passengers. The elevator will have the capacity for 5000 pounds and will likely be hydraulically operated. It was agreed that the project manager will review the elevator design and safety con trols with Mr. George Gorbell. 3. Lime Addition Lime is added to the still pot from 50 pound bags. This size bag is considered safe for personnel handling. 0726163 TOWOLDMONOQ48951 R. S. Yates 2 January 24, 1969 MECHANICAL An external gas-fired heater is used for the still pot. Combustion safeguards are planned by the project; these will include a Honeywell protecto-glow unit. There will also be a pilot interlock. The combustion safeguards should be reviewed with Mr. George Ostroot when the heater design is further along. In addition, some process safety provisions will be incorporated in the heater. A high temperature sensing unit on the process material coming out of the furnace will shut down the burner . on high temperature. If the circulation through the heater stops, an alarm will sound. Standard instrumentation will be employed for these functions. PROCESS 1. Alarms and Interlocks The operation of the chlorinators will be sequence controlled. Chlorination starts at a temperature of about 150C. As the batch progresses the sequence controller steps the temperature upward so that, at the conclusion of chlorination of a batch, the tempera ture is in the range of 250-255C. The temperature will be recorded in the chlorinator; an alarm will be actuated at high temperature. It was agreed that the project will consider use of a differential temperature alarm, based on the desired temperature at any stage of the batch, rather than a high temperature alarm which must function at a temperature higher than the maximum batch temperature. It was believed that this type of alarming would be a better investment of money than the addition of a second high temperature alarm on the reactor, and located in the vapor discharge from the reactor. There will also be temperature detection in the arochlor circulating line on the chlorinator. A high temperature in this line will give an alarm and will also close the chlorine supply valve. The complete closure of the chlorine supply valve will not be possible because chlorine will come from tank cars rather than from the chlorine unit. If flow should cease in the arochlor circulating line there will be an alarm and the chlorine valve will be closed. There will also be an alarm if the therminol circulation should stop. 0726164 TOWOLDMONOQ48952 R. S. Yates 3 January 24, 1969 Other alarms include the following: a scale alarm to prevent overcharge of the weigh tank; a low temperature alarm on the chlorinator at 120C; water coolant to the therminol cooler to prevent too low a water temperature;1 a signal when the batch is 80% chlorinated in order to signal the time to initiate sampling; high (80C) and low (60c) temperature on the circulating therminol. The project is also considering installation of a nuclear instrument on the process circulating line at the chlorinator to determine density; it is hoped that this density figure can be correlated with softening point. If the correlation works out on a present plant test, the equipment will be installed. 2. Operating Time The operating time of the present unit is only about 74%. Downtime on a chlorine plant has been a part of the problem; the new purchased chlorine arrange ment should help this. Another part of the problem has been maintenance. It is also hoped that this can be im proved in order to improve the on-stream factor. 3. HCl Scrubber In order to minimize the HCl venting to the atmosphere the project will add equipment for improved HCl absorption and scrubbing. 4. Gas Fired Heater Operation The firing rate on the heater is manually indexed on a flow controller on the gas to the burner. This type of control has proved adequate with the present plant installation and is believed to be adequate for the new heater. The project will also try to design the heater coils in such a manner as to simplify coil re moval for the furnace. The furnace coils can be expected to burn out approximately annually. This is considered a normal maintenance item and presents no major problems. 5. Residue Removal If the residue is removed from the system in the manner used at present, the fume hood venting provisions will be improved over those at present. The project also plans to try to develop a system for flaking the residue. BUILDING AND FIRE PROTECTION An 181 x 90' x 2 level bay will be erected adjacent to the north wall of Building No. 27. The construction will be open steel frame with reinforced fiber glass polyester wind-breaks, concrete slab roof and steel grate flooring at the first level above ground level. Hydrant #13 with hose house and hydrant #19 with attached monitor nozzle are adequate fire protection. No sprinklers or fire proofing are needed. 0726165 TOWOLDMONOQ48953 R. S. Yates 4 January 24, 1969 A 20' x 30' extension to the existing control room will be erected at the 16 ft. level. The construction will be con crete block walls and non-combustible roof. No fire protection is needed. LOSS EXPOSURE The maximum probable loss was considered to come from loss of the heater for the still pot as a result of explosion in the fire box. It was considered that approximately six days will be required to re-brick and repair the heater. A spare coil will be kept in stock. It was estimated that the repairs would cost about $10M. Six days were estimated to be sufficient for the repairs. The business interruption loss during this period of time would be approximately $45M. LOSS PREVENTION REVIEW CHECK LIST Attached to R. S. Yates' copy of this report is a copy of Form G-1425, Loss Prevention Review Check List, which can be used as a safety check list for this project. LOSS PREVENTION REVIEW BY PLANT The S&PP Branch of CED can not review design prints and construction steps in detail as this project progresses. S&PP requests plant personnel, in cluding plant safety personnel, to hold additional safety reviews at the plant, to follow the development of design prints, and to check the progress of construction in order to make maximum contributions from their experience with these operations to the CED personnel involved in execution of this project. SAFETY MANAGER G. 0. Hunt will be Safety Manager for this project. Please contact him for additional safety reviews needed during design. R. J. Green bjr Attachment : W. B. Howard 0726166 TOWOLDMONOQ48954