Document 10zVN5EOM5vnj0wQVjdbyeX0d
Central Engineering Department Project Scope Report
Solid Aroclor Expansion CEA 2080
New 20 M lbs./year Plant Anniston, Alabama Plant
By: R. S. Yates Central Engineering Department January 14, 1969
072*6095
TOWOLDMONOQ48883
distribution
Organic Division 1. J. M. Smith 2. W. A. Kuhn 3. H. L. Williams 4. W. E. Voss
Central Engineering 1. R. M. Kountz 2. R. S. Yates 3. O. F. Bremer/P.K. Nunn
4. J. w. Campbell/B. W. Steketee/R. B. Degenhardt
5. L. R. Burchfield 6. F. J. Holzapfel 7. Central File 8. R. C. Herman 9. R. C. Herman 10. R. C. Herman 11. R. C. Herman
0726096
TOWOLDMONOQ48884
CEA 2080 Date: 1/16/69 By: R. S. Yates
TABLE OF CONTENTS
1.1 Project Scope Summary
1.11 Title 1.12 Synopsis and Project "Tone"
1.2 Process Technology
1.21 Process Description
1.211 Details of Process 1.212 Yields and Raw Material Usage
1.213 Process Documents
1.22 Raw Materials
1.221 Specifications 1.222 Sources
1.23 Products and By-Products
1.231 1.232 1.233 1.234
Quality Considerations Specifications By-Products Packaging and Shipping
1.24 Waste Streams
1.25 Personnel, Property and Public Hazards
1.3 ManufacturingFacilities
1.31 Description
1.311 General 1.312 Manufacturing Facilities
1.32 Design Capacity
1.33 Flexibility Requirements
1.34 Future Expansion
1.35 Physical Appearance
1.36 Storage and Shipping Requirements 1.4 Utilities
1.41 Utilities Summary
1.42 Utilities Facilities
Page No,
x
i \
3
3
3 3 4
4
4 5
5
5 5 6 6
7
7
9
9
9 9
10
10
11
11 11 12
12
12
0726097
TOWOLDMONOQ48885
Appendices A. Equipment Information Summary B. Process Flow Diagram C. Equipment Arrangement Study D. Building and Site Requirements E. Description of Work by Code of Accounts F. Preliminary Schedule G. Project Loss Prevention Report
0726098
TOWOLDMON0048886
Page 1
1,1 Project Scope Summary
1,11 Title
Aroclors - Increase Solid Aroclor Capacity - Organic Division at Anniston, Alabama Plant CEA 2080
1,12 Synopsis and Project "Tone"
The objectives of this project are to
a. provide new facilities to increase solid Arolor plant capacity from 9.6 M lbs./year to 29,6 M lbs./year.
b. Provide an overall production capacity for solid Aroclors of up to 30% more than indicated in the latest sales forecast.
c. Provide for an orderly expansion of the solid Aroclor facilities.
d. Complete these facilities by December, 1969.
New facilities to be added are:
1. Two batch chlorinator systems consisting of a single terphenyl feed tank, two chlorination tanks with heat removal systems and one inter mediate storage and blow tank.
2. An off-gas recovery system consisting of heat exchanger and surge tank to recover entrain ment lossss from both chlorinator systems.
3. One batch distillation system consisting of still pot, external circulating system through a gas-fired heater, condensing and receiving equipment, and a high vacuum ejector.
4. Sufficient piping tie-ins to insure good oper ating flexibility with the existing batch system.
5. Expand the existing control room to provide sufficient space for instrumentation for the new facility.
6. Expand the existing Therminol heating system to provide proper distribution of hot fluid to the new facility.
7. Add drowning facilities at the HCl plant to drown the extra HCl gas produced from the chlorinators.
0726099
TOWOLDMONOQ48887
Page 2
8. A new elevator in Building 27. 9. A flaker for Aroclor 1268.
Sales forecasts indicate that we will be out of solid Aroclor capacity in 1969. The plant is carrying out a debottlenecking program which will allow us to meet most of our 1969 requirements. The new facilities should be operational by December 1969 or earlier if possible. A preliminary schedule shows that if we can start definitive engineering in January, these new facilities will be available for start-up in December
1969.
Full design capacity will not be necessary until after 1973. It is divisional policy in certain product groups to provide excess capacity over and above sales forecasts and we are providing a 31% excess capacity in these new facilities for 1973 based on the sales forecast of December 6, 1968.
Low capital cost is important to this project, however, schedules must be met for a December 1969 or earlier start-up even at some increased capital cost. There are no items that could be deferred from this project to a later date.
It is estimated that the cost of these new facilities will be:
Capital Expense Total
$ 950,000 50,000
$1,000,000
0726100
TOWOLDMONOQ48888
Page 3
1.2 Process Technology
1.21 process Description
1.211 Details of Process
Aroclors are the reaction products formed by the chlorination of biphenyl and/or terphenyls using an iron catalyst. The by-product HC1 gas pro duced is absorbed in water to produce muriatic acid. Solid Aroclors are produced in chlorinator reaction vessels, air blown and distilled. They are drummed, flaked, or flaked and milled and packaged for shipment.
Distillation residues are discarded as waste or sold as Montars.
Aroclors, when used as plasticizers and that crystallize at ambient temperatures are con sidered solid Aroclors. Below is a list of the Aroclor grades that are considered solid Aroclors:
Aroclor
Starting
Designationi Raw Material
Chlorination
Level
Distilled
1268
Biphenyl
68%
Yes
2565
25% Santowax c
7 5% Biphenyl
6 5%
NO
4065
40% Santowax R 60% Biphenyl
6 5%
NO
446 5
40% Santowax R 60% Biphenyl
6 5%
Yes
5060
100% Santowax R
60%
No
5460
100% Santowax R
60%
Yes
5042
100% Santowax R
42%
No
5442
100% Santowax R
42%
Yes
We intend to make only Santowax R based Aroclors in this new equipment.
1.212 Yields and Raw Material Usage
Yields are calculated for both chlorine and Santowax and/or Biphenyl. Based on cost standards of January 1, 1969 these are (% theory to standard):
0726101
TOWOLDMONOQ48889
Page 4
Aroclor
On
On
On
On
Designation Chlorine Biphenyl Santowax C Santowax R
1268
73 73
2565
96 96.2 96.2
4465
73 73
73
5060
96
96
5460
82
85
5442
80.2
73
The yield on 5460 has not been demonstrated. Last year the standard yield on chlorine and Santowax R was 73.5%
Lime and Ferric chloride are added to all products as follows:
Lime Ferric Chloride
Lbs./lOO Lbs. Aroclor 1.000 0.020
1.213 Process Documents
"Standard Manufacturing Process for Aroclors Anniston Plant" September, 1966, M. J. Williams
"Standard Operating Instructions for Aroclors Anniston Plant" November, 1968, M. J. Williams
1.22 Raw Materails
1.221 Specifications
Raw material specifications, as listed below, are appended.
Material Code
Date
Material
33500
2/26/57 Ferric Chloride Anhydride
83601
11/18/65 Biphenyl
82910
3/9/66
Santowax "C"
82602
3/2/66
Santowax "R"
82638
8/31/66 Chlorine Gas
38800
7/20/66 Lime Hydrate
0726102
TOWOLDMONOQ48890
Page 5
1.222 Sources
Biphenyl
Biphenyl is stored in horizontal tanks in the Biphenyl Area and pumped on demand into the Terphenyl Mix Tank.
Ferric Chloride
Received from the warehouse in 100 lb. kegs.
Chlorine
Received from tank cars and the chlorine plant. In 1969 the chlorine plant will be shut down and the entire supply will be from 44, 55 or 90 ton tank cars shipped into the plant. Liquid chlorine will be vaporized and trans ferred as a gas to the department area.
Lime Hydrate
Received from the warehouse in 50 lb. bags loaded on palettes.
Santowax 11C"
Received from the continuous biphenyl stills on demand through a transfer line.
Santowax 11 R"
Received from a 50,000 gallon storage tank, heated west of the HB40 department, on demand, through a transfer line. Santowax " R" is ob tained from the continuous Santowax still in the Biphenyl refining area.
1.23 Products and By-Products
1.231 Quality Considerations
Aroclor 5460 has a color and softening point specification which because of the nature of the process gets out of control on occasion. Color is more of a problem than softening point.
1.232 Specifications
Finished goods specifications, as listed below, are appended.
0726103
TOWOLDMONOQ48891
Page 6
Product Code 82616 82618 82619 82620 82622 82621
Date 3/11/66 3/11/66 3/11/66 3/11/66 3/11/66 3/15/66
Product Aroclor 1268 Aroclor 2 56 5 Aroclor 4465 Aroclor 5060 Aroclor 5460 Aroclor 5442
1,233 By-Products
HCl gas is a by-product of the chlorination re action and can be absorbed in water to produce muriatic acid or sewered and neutralized with
limestone.
Residues from the distillation are drawn off to drums and sold as Montars or discarded. Listed
below are data on the Montars.
Montar No.
Aroclor
Softening Point Range
Calcium Oxide
5 5460 6 4465 7 1268 8 5442
155-195C 135-190C
200 C
1.6% 2.0%
The plant is considering the flakering of Montars in order to change the product form.
Latest sales forecast, November 27, 1968, in dicates sales requirements for the solid Montars
as follows for the year 1969:
Montar 5
180,000 lbs
Montar 5 crushed. dom. 400,000 lbs
Montar 5 crushed, inter,. 80,000 lbs
Montar 6
50,000 lbs
1.234 Packaging and Shipping
Material 1268 2505 4465 5060 5460 5442
Container Weights
Weight - lbs.
Container
200 41 gal. fibre drum
Form Flakes
50 and 500
5 and 40 gal. drums
Solid
50 and 500 50 and 100
5, 40 and 55 gal. drums Solid
paper bags
Flakes
50 and 100 50 and 450
paper bags 5 and 40 gal. drums
F1akes Solid
0726104
TOWOLDMONOQ48892
Page 7
1.24 Waste Streams
Approximately 2200 gallons of Montar 5 will be produced daily with an approximate composition as follows:
Chlorine Iron Calcium Oxide
57-59% 0.12% 1.6%
Some of this material is sold, the remainder is put in drums and taken to the toxic dump. The plant has a project to pump these waste materials to Cleghorn's lake, a sump used for residue disposal.
An additional 70,000 lbs. of HC1 gas will be produced daily from this new plant and will have to be absorbed and sewered at the acid plant. If additional absorption capacity is required, a separate project will be sub mitted.
1.25 Personnel. Property and Public Hazards
Chlorine Gas
Causes eye, skin and mucous membrane irritation. Maximum allowable concentration is 2 ppm. Concentra tions in the order of 15 ppm will cause throat irri tation. Cannister gas masks, Scott Air Paks or other similar equipment is required in strong concentra tions.
Biphenyl
A toxic organic chemical. Breathing fumes or vapors should be avoided. During processing the material is usually hot (100C or above) and can cause serious
thermal burns in contact with the skin. Protective garments should be worn go aboid contact. Flash point of biphenyl is 235 F.
Ferric Chloride
Not toxic but presents an eye hazard. Normal pre cautions of wearing safety glasses should be followed.
HC1 Gas
Fumes are toxic and hazardous to teeth, skin, eyes and mucuous membranes. In strong concentrations, rubber protective equipment should be worn. Maximum allowable concentration of HC1 gas in air is 10 ppm.
0726105
TOWOLDMONOQ48893
Page 8 Santowax R
Relatively non-toxic, however, the vapors are irritat ing to the bronchial tract. Prolonged breathing of vapors should be avoided. Material is generally hot (150C or above) and can cause serious thermal burns in contact with the skin. Crude Aroclors Crude Aroclors are hot since all are handled in Therminol heated jacketed lines. They can cause serious thermal burns in contact with the skin. Still Bottoms or Residue Fumes from still bottoms are toxic. They are ex tremely irritating to the mucous membranes, eyes and respiratory tract and should be avoided. They are hot (above 150C) and can cause serious thermal burns. Hydrated Lime Dust is irritating to the eyes and skin and any material on the skin should be washed off with water.
0726106
TOWOLDMONOQ48894
Page 9
1.3 Manufacturing Facilities
1.31 Description
1.311 General
The following information is included in the Appendix of this report:
Equipment Information Summary Process Flow Diagram Equipment Arrangement Study Building and Site Requirement Description of Work by Code of Accounts Preliminary Schedule Project Loss Prevention Report
1.312 Manufacturing Facilities
A 2000 gallon mix tank for terphenyls with charge lines and supported on a 40,000 lb. hopper scale. Two 3100 gallon chlorination tanks with circulation pumps and heat removal systems consisting of two shell and tube heat exchangers and a Therminol surge tank and pump. An off-gas system consisting of heat exchanger and 2000 gallon storage tank to recover entrain ment losses from the chlorinator off gases with tailings pump. A 6500 gallon batch intermediate storage and blow tank with scrubber and transfer pump. A 7300 gallon still pot, 3500 gallon receiver with entrainment separator, still condenser and ex ternal gas fired heater with submerged centrifugal pump. A condenser control system consisting of two shell and tube heat exchangers and a Therminol surge tank and pump. A three-stage ejector with intercondenser, and aftercondenser and catch tank and sump tank. Additions to the present control room to provide space for additional instrumentation. A two-stage HC1 gas drowning system. A new freight elevator for Building 27. Additions to the present Therminol system.
072.6107
TOWOLDMON0048895
Page 10
1,32 Design Capacity
Chlorination:
Basis OST Rate
Producing Aroclor 5060 6350 hrs./year 27,6 M lbs./year
Distillation:
Basis OST Rate
Producing Aroclor 5460 6350 hrs./year 20,0 M lbs./year
After these additions are complete, plant capacity will be as follows:
Present Capacity New Capacity Total Capacity
9.6 M lbs./year 20.0 M lbs./year 29.6 M lbs./year
Basis:
OST 6350 hrs./year OAY 73%
Based on the December 6, 1968 Sales Forecast, (HD to RY), excess capacity will be as follows:
New Capacity Required Excess Capacity Excess Capacity
1970 29.6 M lbs./yr. 17,1 M lbs./yr. 12.5 M lbs./yr.
73 %
1973 29.6 M lbs./yr. 22.6 M lbs./yr.
7.0 M lbs./yr. 31 %
1.33 Flexibility Requirements
Two complete and separate solid Aroclor systems will allow flexibility in our production runs. We will pro duce the larger volume requirement, Aroclor 5460 (82%) in the new units with the remaining solid Aroclors being produced in the smaller unit. Consideration will be given to incorporating the chlorinators into a continuous chlorination system at some future date. Both units will have the flexibility of being able to produce any of the solid Aroclor products. If fractionation is required to meet FDA standards, a separate distillation unit can be added to the existing system.
0726108
TOWOLDMONOQ48896
Page 11
1.34 Future Expansion The present expansion will occupy an 18 foot wide area directly to the north of Building 27. There is suf ficient area to the north of this expansion to provide for two additional chlorination-distillation systems. In the meantime, work should proceed toward developing a continuous chlorination system which long range should provide greater flexibility in labor and equipment.
1.35 Physical Appearance We propose to make the top roof deck concrete, a contin uation of the surface we installed to the west of Build ing 27 on project OEA 4-488. Additional weather protec tion will be provided in the form of a panel enclosure on the north wall of the structure.
1,36 Storage and Shipping Requirements No additional storage facilities are contemplated. Re cently completed project CEA 1430 provided a 5500 gallon day tank for finished solid Aroclors. In addition, a new 6900 lb./hr. flaker with a 5500 gallon flaker feed tank has also been installed in a separate flaking and packaging building. Raw material storage for Santowax R and Biphenyl are adequate.
0726109
TOWOLDMONOQ48897
Page 12
1.4 Utilities and Services 1.41 Utilities Summary The approximate utility requirements are as follows:
For ejector, lbs./hr.
450
For tracer and tankheating, lbs./hr. 250
Power, Installed HP
245
Cooling Tower Water, GPM
600
Potable Water, GPM
50
Natural Gas, Cu.Ft./hr.
2000
1.42 Utilities Facilities
No additional utility facilities are required for this project.
0726110
TOWOLDMONOQ48898
w *WMCimeMJMM|M ' > , W. O. KKUMM1U.CH WA** . ' *' RAW MATERIAL
^ SPECIFICATIPM-
ieeuie
FERRIC CHLORIDE AHHTOMDg
GNHCkl PORMVk*
*,`i4"is .
FeCl,
UHKRBWCIW _______ Hee_______
UWJ W UiLVIM '?..... -----------------
_ _ _ _ _ tstffs.. *.. maa.
UNCLASSIFIED INFORMATION
General Teuto (made only on rifuit)
Prprty
Appearance
Specification
Black powder or jrnnalna
Asaay
97.0%, MU.
- Soliatee
0.05%, Man.
- Ferrous Salts
Trace, Man.
Solubility.' 10:10 ol water
10:10 of Formula SO alcohol
Complete to allfiUly turbid. Max. Complete te alightly turbid,
Man.
WWFel>. 2b, 1957 .. STMUIK
VeAd-r____ la bLa v)
rsc 1*2.21
J.F.Q. MefiWdJWw^Pf! Ib-A
22-57* 120-m S-570-1 112-B
! *,
.: V;- Htt
'?
*A, f,
` V
. ?l $
ii
0726111
.
-.{. vi v* Xy, , ... .J
TOWOLDMONOQ48899
Monsanto Chemical Company
ORGANIC CMEMIC44-S 0IVIS40N
FINISHED PRODUCT SPECIFICATION
product fTradt nairttl Biphenyl
p roouc r (Oatmeal *mtt) Biphenyl
CHEMICAL FORMULA
MOOUCT COO*
nuia
MfTMOO lOSNTITY
*AL COO*
135-000-03-09
Tret
Technical
T*P
Technical
tuPEPtCOCi PC* OP 7/6/65
cub10
| MCIAt-JO* NO. (AMRl* POM ANAL VM* 1 1 X 16 os* can
Issued 5/5/61
Anniston Plant
*
By V. W. Klcaaer L
Revised to add typ 43
mol t. 154.20
u*c Salas
_
4P
cI
n I .| I
1
Characteriatica Routine teata Appearance
Crystallising Point* *C Color* Gardner
Halts
Vhite to pale yellow crystals 66.7 Min. 6 Mas.
General Teat (detsnalned only on request)
Biphenyl, X
Napthalene, X
3 * Methylbiphenyl, X
4 * Kethylbiphenyi, X
Unknown, X
Diatillation Range, *C let drop - Dry Point
Must Include 255*0
Tmical Values
Whit, crystal. 68.6
1.5
99.9 0.001 0.05 0.02 <0.03
ThU specification for internal uee only 0726112
TOWOLDMON0048900
Monsanto
FINISHED PRODUCT SPECIFICATION
'"OLoOION
1 J. Moodv /a/ 2-1-66
1 ALC
. ; . Ault /s/ 2-22-66
u r NLA t, 0(K*l6TlON
ture
. ' -S 7
' RICILD INFORMATION i Mrance i iing Point, *C ho Terphenyl, % * \ 3 Terphenyl, 7 i .,i-) Terphenyl, % . rerphenyl, X l.enyl, 7. i Point, C
M t ine, ppm . 1 :r, ppm
MOOUCT Santovax C SlAnV aAmnniston 3-9-66
eaoOuCT coot 829.10 **1.kk c6bl 7795-050-99-009
1 y.
utf Internal
hcaiAh^H ""
L. R. Stark /a/ 2-3-66 - M. McEven /s/ QUALITY CONTROL (Chft Chmilt>
O. E. Dolln /./ 2-1-66
CHBUICAL fOKMVLl
. ? -16
worn ANAtflii 2-1 Pint Cana
LIMIT*
**ue *v J. A. Llddlc 1-12-66
MCTMOO
Brown, waxy solic 350 Min. **10 **50 **26 **14 **0.1 **375 2.0 (Typical) 2.0 "
G-L
064 064 064 072 064 114
ribution of Isomers and quaterphenyls vary with operating condition.
Limited data la available; therefore, the Haiti given are typical values i i o characteristics.
r roduct is mainly used as a raw material for other finished products produced ir i on.
i- pecification is for internal use only.
MO i
iV Routine Analysis, All others Analysed by request Only
0726113
TOWOLDMONOQ48901
Monsanto
FINISHED PRODUCT SPECIFICATION
POODOCT ION
IXRL.CIG. Moodv /a/ 1-31-66 U. E. Ault />/ 2-22-66
oneiTioN
PMOOUC T SScaAnnItovax R BAinfni inatrotnifMi
aaooucf c'iol 826.02 liiiiii&i
^ Wll S.le
J
|OC r, 2
7793-000-11-009
A9viLI
**!**
l. R. St*rk // 2-3-66 - M. McEw.n /./ 2-22-66 OOAIvIT V CONTROL fChl*f ChumltO
0. E. Dolln // 1-25-66
CHtMICAk fORMUL*
Mixed Terphenyls
2-12-62 t u.HACTLRI.TIC
IAHRlI FOR ANlKIII 2 x 1 pint cent
UtMTI
wee v J. A. Llddle 1-11-66
MCTMOO
UNRESTRICTED INFORMATION (R) Appearance
(R) Color (liquid), NPA
(R) Upper Hold Point, C
(R) Lower Hold, *C
RESTRICTED INFORMATION
Distillation Range, C, 80% (Uncorrected)
Ortho terphenyl, % Meta terphenyl, % Para terphenyl, % Quaterphenyls, 7.
Yellow white noneryatalllne flaked solid
4.0 Max.
136 - 143
48-63
350 - 400
10.0 - Typical Value
54.0 - "
"
27.0 - "
"
9.0 - '
"
G-l
128 129 129
h h ,utm. In.
^ // olhr'S .<
d by rtque %i Only
07261X4
TOWOLDMONOQ48902
Monsanto
MAVKMIAL COOK
826.38
LANT
MATKMIAL
Chlorine Gas
UKIMK OKPTt.
RAW MATERIAL SPECIFICATION
Anniston 0atc errccnvc 8-31-66
84. 05. 27
m/mlKa
See below
AHODUCT ION
APPROVALS AMKAneM
R. G. Moody /./R. G. Moody - 8/11/66
MOCUItMINT
L. R. Stark /s/L. R. Stark 8/29/66
Quality conthol Kmw CMPM)
H. L. Phllllo. /./H. L. Phil1Id. - 8/15/66 O. E. Dolln /./O. E. Dolln - 8/10/66
QKNKNAL DKACAtPTtON
CMKMICAL KOAMULA
Greenish yellow gas
tUPINtIDIf *KC* Ol
Sept. 11 1957
C HAM AC T IRIIT1C
IAMPLK worn AMALVI* jGLCsaniln^contalne
LIMIT*
UNRESTRICTED INFORMATION
Materiel Supplied by Diamond Alkali Company
Assay, (Vol. 1)
Residual Gases (Vol. X) Moisture, ppm Non-volatile Matter, ppa
99.4 Min
0.5 Max. 40 Max. 40 Max.
Material Supplled by Depta. 56, 57 (Anniston)
Assay (Vol. X) H2 (Vol. X)
C02 (Vol. X) CO (Vol. X) N2 (Vol. X)
02 (Vol. X)
Mol. vt. 70.91
IMUIOIT
I J. A. Llddle - 5/16/66
Typical
MiTHoo
Value
113 113
85.5 - 93.5
1.5 - 2.5 (3 Max.) 0.5 - 1.0
Nil 3.0 - 8.0
1.2 - 3.0
113 113
113 113 113 113
(A/ Aoviln# Anilrili, All 01hart Anatynj by ffumat mnly.
0726115
TOWOLDMONOQ48903
Monsanto
MATCMIAi. COOC 38600
ULlllaltal OIHOyT6d.rate
R AW MATERIAL SPECIFICATION
Aimla ton 7-20-66
27. 28 WWXII* Alabaster Line Co.
.
.OOUCTION
APPROVALS BillAMCM
R. G. Moody /s/R. G. Moody 6/9/66 MOC U6IMINT
*. F. Mueller /a/B. F. Mueller 7/13/66 0ua4.it v eoMTMOi. rcMef camum)
H. L. Phllllsa /a/B. L. Phllllna 6/10/66
0. 1. DelIn /a/0. I. DelIn 6/8/66
CNCMCAL MPRIMM.A
White fine povder
Ca(0B)2
Sept. 11, 1957 CMAMACTtmanc
UNRESTRICTED IMFORHATIOM
AMAkC MOM ANAUVMt tz - 1 lb. can*
Typical Analyala
Mel. t. 74.10
TBuibit
J. A. Uddla - 3/16/66
C.0 a>
73.00
m*o <x>
1.20
SlOj (I)
0.36
ai2o3 (X)
0.60
Fe203 (X)
0.30
Ignition Loot (X)
24.04
C*(OB)2 (X Calculated)
97.50<l>
Screen Anelvala
Through 200 neah (X) Through 325 aaah (X)
99.8 94.5
120
Basis of Specification*! Supplier* typical analyst* of product (5/23/66) (l) Ca<0B)j X - 100X - [>(0(X) + S102 (X) + AljOj (X) + F.jOj (if]
<H) Rociln. Analytla, All othuf Amtv**4 Or hkmI ml?.
0726116
TOWOLDMONOQ48904
Monsanto
FINISHED PRODUCT SPECIFICATION
PNOOUCT ION
W. E. Ault // 3-2-66
6CNCA4- DCMIFTION
Mixture
PftOOuCT
lotFT.
meouct 4661
127-S ull T
A8T2164.1lo6os
Sales
3-11-66
1040-340-04-11-16 -009
AFFftOV AL
imfw---------------------------------------------------
L. R. Stark // 3-8-66 OUALITV CONTROL
O. E. Dolln // 12-29-65 CMKMICAL. FORMULA
MOU WT.
uptpicoii ipici. of
4-25-61 C HAM AC 1 IP ll T (C
IAUFLI FOA ANA|.VI*
wsvsaav
~
1 x 16 oz. Can or W.M. Bottle J. A. Liddle 11-30-65
UMT*
MCTMOO
UNRESTRICTED INFORMATION
(R) Appearance and color Color. Gardner
White to off-white powder 6 Max.
(R) Hold Point, *C
150 - 170
(R) Acid No., mg KOH
0.05 Max.
RESTRICTED INFORMATION
Screen Test, X retained on
No. 16 mesh
0.1 Hex.
No. 20 mesh
10 Max.
Specific Gravity @ 25/25*C., Pycnometer
1.804 - 1.811
Loss @ 163C., 7.
0.15 - 0.24
G-l 119 116
120
K R . i i in... > '.'. { 11 i tht r f Anoly ted by requt st Only
--------------
072611?
TOWOLDMONOQ48905
Monsanto
FINISHED PRODUCT SPECIFICATION
PRODUCTION
R. G. Moodv Is! 12-29-65
ULlt
w. Ault III 3-2-66
Mixture
PROOUCT
Aroclor 2565
PRODUCT cook
joPT.
I27-S
.
BWMMreTivi
826,18 mu coos
Salea__________ ____ _
1040-390-04-009 approval
nirrorrs-----------------------------------------------------------------------------------------------------
L. R. Stark // 3-8-66
QUALITY CONTROL fCAiPl ChnmltO
3. E. Dolin hi 12-29-65
CMKMICAL FORMULA
IU(MEDII P*C. OF 4-25-61 CHU4C1 KRIITiC
UNRESTRICTED INFORMATION
(R) Appearance and Color
(R) Softening Point, *C
(R) Acid No., mg KOH/g
AMPlK FOR ANAivIII
lUutD ------------------------------------------
1 x 16 01. Cm or W.M. Bottle J. A. Ltddle 11-30-65
LIMIT*
MKfHOO
Black, brittle reeln 66 - 72 1.6 Hex.
G-l 115 116
'R/ Routmt Anaiys h, All o(htrt Anolyted by rtquett Only
0726118
TOWOLDMONOQ48906
Monsanto OROANIC c NiMiC AL OlVItlON
FINISHED PRODUCT SPECIFICATION
ORODUCTION
ULII
W. E. Ault /./ 3-2-66
Mixture
PRODUCT
Aroclor 4465
Anniaton
3-11*66
imsv ali
dur 1
826.19
ull
Sale*
|oFT. 127-S
......
1040-430-04-11-16-009
L. R. Stark /a/ 3-8-66
QUALITY CONTROL {Chief ChtmltO
0. E. Dolln // 12-29-65
CMBMICAL FORMULA
iupemioii setci, OF 4-25-61 CHARACTER,.T,C
UNRESTRICTED INFORMATION
(R) Appearance and Color
(R) Color, NPA, Molten
(R) Softening Point, *C
Acid No., mg KOH/g
IAMFLI FOR ANAkTM
SIuiSTv----------------------------------------
L x 16 oil Can or W.M. Bottle J. A. Liddle 11-30-65
LIMIT*
MCTHOO
Clear, light yellow reain 2 Max. 60 - 66 0.05 Max.
G-l G-4 115 116
R Routint -I r > i > s i >, 4 11 others A noly ted by re flue st Only
0726U9
TOWOLDMONOQ48907
Monsanto
FINISHED PRODUCT SPECIFICATION
R. G. Moodv /a/ I2r.lfl.-6i_ W. E, Ault /a/ 3-2-66
4 DESCRIPTION Mixture
>*OL "TlUPCPAIDCt tPICt. OP
4-2S-6L
UNRESTRICTED INFORMATION (R) Appearance and Color (R) Softening Point, *C (R) Acid No. mg KOH/g
PRODUCT
Aroclor 5060
SL*Nf
Anniston
PRODUCT COOC
826.20
SALII (Ul
_______________ 1040-450-04-009
APPftOV A LI
TuKIUTm-----------------------------------------
L. R. Stark /./ 3-8-66___
QUALITY CONTROL (ChM ChemltO
0. E. Polio /a/ 12-29-65
Sales
lofPT.
1 2 7-S
AMPLt POD ANAl.r*l
1 x 16 oi. Cm or W.M. Botel* J. A. Liddie 11-30-65
LIMY*
MCTMOO
Black, brittle rasin 105 - 115 0.5 Max.
G-l 115 116
R Ro{.r>r ir.jiyMs. ill oihtis Ariiilt led by request Only
0726120
TOWOLDMONOQ48908
Monsanto
PflOOuCT
Aroclor 5460 (High Soluble Grade)
sun?
HAMT <i6l
nil
|o*T.
127-S
FINISHED PRODUCT SPECIFICATION
I'M ODUC 1 ION
SALE!
Anniaton
DATS IffbcVIVI
826.22
lltll CW(
3-11-66__________ 1040-480-04-009
APPIIOV ALI
hltliUH
-----------
L. R. Stark // 3-6-66
QUALITY CONTROL few*/ Chal*U
S.lti
--------------------
W. E. Ault /a/ 3-2-66__________ !--------------------- O. E. Doll. /./ 12-29-65--------------------------------------
Mixture
4-21-61
l4M*kl DM 4NAITIII
Mule v
1 x 16 os. Can or W.M. Bottle J. A. Liddle 11-30-65
LIMIT*
MCTMOO
UNRESTRICTED INFORMATION
(R) Appearance and Color
Clear, yellow to amber brittle reein or flakee
(R) Color, NPA, Molten
2 Max.
(R) Softening Point, *C
98 - 105
(R) Solubility (25 g In 25 g. Acetone @ 25*C.)
3 hour, Min.
Acid No., Mg KOH/gm.
0.05 Max.
Chlorine, X
58.5 - 60.6
RESTRICTED INFORMATION
Hydrolysis Stability, ppn Cl
300 Max.
G-l G-4 115 117 116 093
092
RR
An<ily ltd by
()nly
0726121
TOWOLDMONOQ48909
Monsanto
FINISHED PRODUCT SPECIFICATION
PNOOUCT ION
R. G. Moodv /b/ 12-29-65
inn
w. t. Ault // 3-2-66
t. C NlHlv DCECPIPTiOn
Mixture
PROOUCT Aroclor 5442 fTiW*" *^m '
PRODUCT COO*
jotPT. . i 27-S___ ufl----------------------------
Anniston BYflnFFRV IVK
826J1 ' BALI*COOK
Soles
MfrM______________ 1040-470-06-009-----------------------------------------APPROVAL* umiwea------------------------------------------------------------------------
L. R. Stark // 3-11-66 DUALITY CONTROL fChUt ChmmtlO
0. E. Dolln // 12-29-65
CHtMlCAL PORMUI
lUI'EKIEOEl IPtCI. OR 4-25-61 ': 64IUC T E1RI* TIC
UNRESTRICTED INFORMATION
(R) Appearance and Color
(R) Color, NPA, Molten
(R) Softening Point, eC
Acid No., mg. KOH/g
AMPLC POR ANALT*I*
MfVSO
1 x 16 oa. Can or W.M. Bottli J. A. Llddle 11-30-65
LIMIT*
MtTMOO
Clear, yellow atlcky realn 2 Max. 46 - 52 0.05 Max.
G-l G-4 115 116
0726122
TOWOLDMONOQ48910
CtNIRAi (. NC.lNfc LRING DEDARTMtNT
EQUIPMENT INFORMATION SUMMARY
/ I/
/-r
CIML QIJIl'Mt NT l( NT II K AT ION
NUMIH '
/-//
//
nt sc inn ion o> 1 QUlPMENT ITEM
.'/ v
Si 7 E RAT INC. - MODEL. ETC
v/"- - TS X
CONSTRUCTION -A,.- , V,.
IPERATlNC. WEIGHT POUNDSI
REMARKS
f. ESTIMATED if It
.. 17. . <
- A'
sf.'f -
%6:. w/.
/r.-'. fi /-
//V a* / '/! " 'fTt/H'/i* OF
/-/o/-oo/ /-/'- -1 ..
7k>f/y
/ - iEH? /7*b XW
/
. ,,v- * V
Tire
V
/-/cV-.V
/)*- '/*r.^ , ,r> a'// / / Y v-,v <.
/h , :
. . -. . .
/ %6 '?/A Xae <uf &/jt // <5 8/a*>s~
fieri ~/2E/?r#
/ 4ooa. - nf
C- - ^ - * r /V
-v v./. , / - .A/y
J
Av /-
0724123
TOWOLDMONOQ48911
Cf.NlHAl ENGINEERING DEPARTMENT /. .
EQUIPMENT INFORMATION SUMMARY 411
r"
1 t> 1 OUH'Ml NT me nt iru *i ion
NUMUtK
or sc mm ion o t OLHOMfNT IT EM
SIZE BATING MODEL ETC
M AT EBl AL Of CONSTRUCTION
. ' r- I /
' ' 4 _'5'
/
IB EB AT l NO POUNOSI
REM ABK 5
-V . /*'
/- /
i * i
ESTIMATED
PRICE 'Si
71,.,../), // * / r. V //VO-
Ay' i . -/T
hu - -
*/<'
<- *
~tj O it >-
/-/Or -On/
fia. '>/' / S//f- //*, /.' r
rror
A/
/-/Or
-./--iK/A,/ v. /*4 /r.'
/ 5'v^r V (t>A*
<s.,t w O'rr-< 470 , - t/A'*" r/uC: A
S4 "67> C.cA**-
/V \r. 71*
'At <t> Aav f.** <t\ r/Ai
fy
6/'// , - T/y/A
fit* 7' ' - ../ O, / ' o.
/-/,
... / ..
/ z/o 6 /. //- - - /J,
/}/ /
A .
//
0'L , .
. /L ; `-
-_
/; -
A
0726124
TOWOLDMONOQ48912
CINIRAl ENGINEERING DEDARTMENT /
EQUIPMENT INFORMATION SUMMARY
/j V "O' *._y
a ..
`
y -,.rr
/ a - //./'
POUNOS
RCMARKS
/A.. . ,
?y ' *-r / k/*Z />.. . - /
a/v- >' - ' LA.,-
A zr> /
<Vy- C*A' /''&<! Crt.
Acr/'f
%.-.rA Asit - \/K 'V*K Un,*
/)r V 3rm W//+ A/-
zh*> 7 '
A//Ajt
7?.v>
>
<5A' . '
,
A rV ~y,r
-A o // `"'fr/
^47*; V Ac .
v'
/* s /
.^>7-
A /V rA- - -'
kvV * y- y"
?*>*> V-
A , .c
0726125
TOWOLDMONOQ48913
CENTRA! ENGINEERING DEPARTMENT
EQUIPMENT INFORMATION SUMMARY / . Y
GO n `
/
(. 1. I) l Ollll*MF N T NOMUCI'
Df SCRIPT ION OF e ouipment new
/'/"
Crt vv!.-
QT v
SI Z. RAT INC MODEL ETC
/ ?C0C 'G/t-
MATERIA!. OF CONSTRUCTION
A/V * K -C-rrS..
TPERATlNC WEIGHT pounos)
HFMAMKS
kj'v ' Y,v.
`too--/ A'/-/ -
"
-VV,~ A-'*
i ESTIMATED price
i 1 >1
k
/;.*
- r' C
7 Ay >.- '
4;o - tK.'
A A... / A.
/-//6
As/4--~ //oh/r- CiA/T/iv/v^u
/ /CO 6PM/So`Pi 0utrtL.&. /f\c, P/C
,v//VC: . /Izc*- /a.
/-HO -DO* rfo70>C //.*<.. A^4`` / >a //ft: T V y*
/'///
, CUrc* T/,'
/ 3 'a / i. Ct<Kt' '
Ac .1 * v4>//*;//
rrrc
A'
-C/r k //
< -y
/!x
. /'?'
A v
' / . , . /?/' - .
/t
0726126
TOWOLDMONOQ48914
CfNT/Ml f:NGINfERING DEdARTMn7
/.'"'V-.o EQUIPMENT INT0RMATION SUMMARY
,.r
/
/ >/ , l I ll fQUITMtNl lilt NT 11 1C *1 ION
NUMHlR
/l A*- v .- cU.O A. or.sc ript ion oe EQUIPMENT ITEM
QT V
SI ZE. RATING MODE-. ETC
T OF CONSTRUCTION
>PRA7/NG WEIGHT .POUNDS)
REMARK, j
A A- A / A
J-tiZ
A/ r.
/?,,,, l`K'fK-'' '<+*-
/ '5b />/>,-75''Hi
/}<
JO
A-V
4 4 \ /-A/,
//
hi/..
- /%. 0\. , T/->> f /. ..
/
7/y <
A,
t-n?
TH ^n) i/t/C L she.i Z>'
/ /ZSob1 H* /hf< CooiH/> J&:> a a j/p~f
5m.
f~Jt3 -<?,?/
/tft/a/i, 7Ha. *)//*: i.
&><*' />>*
1-lH
7Hts.ro/*v,;. tv/i',/
/ ZHP/s/6o fm
/
3oo tZ/u.
&Ki'C* ^TJCCi
AZ'dAx^/'i/XH
/-//./ n'
a. /-'A./ /-/*/' Lr*/Tii // . a-
v&hon:
a; V/- f.'/i.
/ for'A* hi Jjf Tt. ` /a /)v;
/ j?y /''"//in 4 P"
' W //>'JL r/ &4.AO' yV A&rv>A? >fJ'k^roK /S6 >
rrre ////
yV '
h//o*i t~'*r\r* A* V
//''/>/* Cof*-
( '**>) ..
/itv
a *.-
&/r " *r.-.r, - ~ 9-BS/B s
fv/z's,*'- a " 4//. .
At.-* '-'Iv.- -> ,> As//
A''
/?
A
A,,
072AIZJ
TOWOLDMONOQ48915
CINTKAi [ NGlNf f RtNG DFDARTMENT I' /. .
EQUIPMENT INFORMATION SUMMARY
7'`'`" . .
< t:
/
.11.1 Ol.H'Ml NT NUMH[ II
DESCRIPT ION C f EQUIPMENT ITEM
MODEL ETC
CONST RUCTION
IPERATING .POUNDS!
A //('
7tfZr.rO/A/oK ^s-viAa,
/ />'}/.
*['/
737 - i / -
t- ir// .
7c4\ :. .
'*/ . ~v*.
. ..........(
2P*l`A - ZO.^
-/
.. 1 . S % . I ^
ESTimTECj l Si
V
/ - n~7 /-/!8 / //<? -c '
^Wx/W.'////*'.is. A/'~> //
C/tf.-'*C ft./Ar* i'Sr/J/.r(
> A.
/ A-/ V ,v '<?$ '/</*S'
7>r/v.
/ 6/Wi/7s'tdh &>
S/T
A. <
S4/-
- for, -
$A1f -* /V.. A/
4rv-/, Wf Tor , r..
tf
A/e* /vav sr/t. V
Tcri Av. v` / . /- .
/>'' '
tf
/- // J
-Itf. v ' . (/ i.r/.
/
"
dtv " Mr
\-;Y
* 7 T'
/ '/Mntf rr
//. < ' V V/.
y, A .
- .
Y/.. 7V-
. 7:.. /
' ^7 y 4^ . / *>,;>
/ A-.A' . /
Z9 ..
>
/
l tLOf TH'
V1
/> .
072612a
TOWOLDMONOQ48916
CENTRA! 1. NCTINE ERING DEPARTMENT
EQUIPMENT INFORMATION SUMMARY /
i tot' OUlf'MC H ' lljf NT II 1C. A T ION
NUMHHI
//:
/
EQUIPMENT ITEM rff.-T" t 'A' 'A/s> ' - /*-.
/- A. /
Ifrc/^/h '/yo.* * >';`v f 7?>mk
OT \ Si 2 E . RATING MODEL. ETC
/ 4iS AC -'r' /}t /-s': `c
MATERiAl 0 1 CONST RuCTlON
=M - 'A ... .
5rfr.-
a, "
k-`.r
/ SOO
'7i'. cV//
4Z*,J *//,.-.TA
'RFRATING .POUNDSI
REMARKS
l
U/r-,. r -
^/// ' 7, '
Z2: 6 \ *,"s - -
V.- .3 r '
A
A,
Pit
*"
foe /*,'<. * v- y
i
K /'V/tt:*r
/- n..
/ /v.z~o t
7/V/\,rri/A-t J. fv/WS*
/ Sol 6,>'6f/i 'HD /\SI' r/*"*,
/V SxU-)3
/iO!v Z/Zi&Xwciyvr*'' /
7Hrjn)'mi ^ <T *2
/
ZnHr/,,,
tr. /,4a? v '
OfA 6 , ^
75 7 D&rj ?D"OM yiODT
7/l/<V />,fKr w>A, A /'O '
/r7~c.1
* ^ *&f' V /j/Ws rr~ /, /: / -... f />,-> - A-f-,' *^rpjjrtr
,v
----- _________
_____
0726129
TOWOLDMONOQ48917
CINTRAL ENGINEERING DE DAR TME N T
EQUIPMENT INFORMATION SUMMARY
/:y. - \
1 [II F Qllll-MC NT NUMUCN
A/:.*
/>r:.uc DESCRiPT ION OF EQUIPMENT ITEM
t/*:>> a;
OT Y
SIZE. RATING MOOEL ETC
MATERIAl. OF CONSTRUCTION
/ ?CC- AC FA!
YSa ooa-
A- /or'-* '
; y. - - X'rf,
\l ' /A ; . ;",v
.POUNDSI
RLMA/IK5
^ /^. T /'A' . y /
1 A
11
/`fo'orf /J.'K
/ /s/zs//*>- i>
TFC
A/
/ -tur
fy. dW `fj T/its'K
/ SOO /20HO6*/*O"
i-nr f-t' /
ft* .. ^V ` A , . ^T/y /. <f *
v. v ..................
/ /2>~*>>,/31' /V. 3ri-S6
/ sWy/i/- : *
fr.&o
A//3u/Fa*C 7_
V4*5 /*/?* /VTi>4 f``f/ MJ -48'/>**
* Vsv^-i
/*/?7/ /'/* 3 /#/ A/y* vr
tfdJV./V'
V
TA x
/O r-S: rv's
>- FS: *" '' -* /
......
/ivc. //t'--
A
A '"> ".y ^A*V
.*
7?V -
/,
IVHI CHI V
0726130
TOWOLDMONOQ48918
ciNiRAi engineering DEdar7mcnt
EQUIPMENT INFORMATION SUMMARY /. *' /- '
Vr *
/ -VC t (1 [OUll'MI I O [ N T I ri c * 1
NIIMHI'K
So/**
/-// 7
O/
' .Pm , Of*
Z3CJ/it.r: A-"
6'A// M*'r .--A r^-r
fif'vl 6
/ ,V 4*
lPERATcS.' WEIGHT .POUNDS
/ /
? . /S /-/' `6 /
/- /za
Jtih Af,
A/cfiiCri
. <
A 3co.o^*& Owe;,* rzt./. \/4ooo
sroc W '$,/ x Ss'/Oi*
Cfc t So %
WI
^AtTM -* Sso '
Y~//\CO tv/T*
/'/!<*- so,
St/u. A/, S fit, P*,7n :/
CrPS d/S'f**
/-/?/
Sr/n Pj~
S
'/scr i/u.
/Si "OS <r /<r
Of/Co'p/ <k-WW.
A//-%rf.r\ /p*` M y*ti. a : w a . Viet S*tp- / v l^va* />/+'''
\Ja,s ' A/c, * .*" /ZOO' .F.
0V26J31
TOWOLDMONOQ48919
CIN7RAI iNGtNBERING DETRIMENT
,, .EQUIPMENT INFORMATION SUMMARY /, > /
/ /O - /S
( t U 1 OuipmE ni IDE NT 1 F ir *1 ION
NUMH E t` /-/SO
/-/Si
Ilf SCRIPT ION or E QUIPME NT ITEM Cyci 3/y/ ^r/'/Vi'/y rc/
QT V
SIZE RATING MODEL. ETC
/ l/A - CC //VO Cd*/E- ^'6 '
-* - 4'6 `
MATERIAL O' CONST BUCT 10 N C/W c v 6?rr*
TPERATiNG POUNDS
/ REMARKS
% X
ESTIMATED
PRICE 1 S>
'/*t- W Sf/.U */,C . A, Vi*' //,t he/ - -t
?c if
STU-. /Vo S /oA/i'Z/V^Ar. /
.t bOOCCC A *.
Stfdi. 'k/ut-Z.
460
/r
Zo"&a < /
LA>. C , / ,1 7r S/IEi./ * 6HUM.-
2 /uHC C
4ZOO
*" '&A "/i at- v
x/4f .-v : & XT Xl/wf O PaCI ow TV*/ &/? J*/Si// / m. r Ju6l~
/A/sn AfazrT r'/OO iS
/~/32 /-/S 3
Srui M> S //cltvrn /
C^/K TaC/vISC A -A//1' Hof.) !* . (*C*j }/C/ fU.- /*-
/
3SOO 6AI
("/Hie# Crea
/0'Pt>*/ZO"/i>6H
/SO 'rt> f^CTU-/-~ // ')// /h: 3. - -/</
E^coo ,W/u/'S-\ ~ Xu& <y
///(l JA/St/*S'*Ait c
bi/'rr ik/jr-ior <SfGOJ.ec
k/SOrysl 2" , /* r .v
/r/ti A>cc>}:>- '/.> /0,ui
jAr-^z C'a\ a
//
/-/$ ~/r> /
/*/;'>*. , A CvK 7a/A. r * / a?j/': o
-<`/J v-
' `*
/V/ 2
//
f I l> Wl'l 6>< 1 Hi Leu !> NORMAL (ON'iNHOK ' tl MATERIAL UMlCMtVC# IS l'HVH
/<* ! .f / .
_________ 1
0726132
TOWOLDMONOQ48920
CENTRAl INGINEERING DC DAR TME NT
EQUIPMENT INFORMATION SUMMARY
/* `A y.
IDCNTNiUfM1CftAfTRION
/- /:*4
"'US / ' ` >A
FQUIPMENT ITEM
A/o S V/ror/c*/
QTV SIZMEODREALT.INETGC ZOO <$r
/or '/si 7/ipS/ Z/j>V!
/pr
CMOANTSETRRIUACLTOIO'N
Crzsj
/- /3+ -On/ /lotUK &t<~ A/., Cwcoir-''H* si asp
/ ec/fp/ /&a- ///>.
9-2/-6 *
IT
1 t 1/
"//
/s
/' SO - 6 /
.POUNDS' i
aJ
Tr.-
A/
/- /3/r
.o?cm 7?)u<
//>#// x/
SCO G/U
Ok 6"i* Ct/t/ S27S
yS/'/SrtP
'V CS
sc** w'sct'*'
WOvPn /P-
_/S/jvPrt*. ~ s*ta
A-/S6
Still A/n Sjcrrort
/ 6t?#rt*/rc
a;W/TH /A!TOP.
CoAJbtA/r. /
A/je*i..z- , /&({.-.*.A-AJ
rifrzK Zf*i&r A/?/\ A*:. :*'*.
/AiZ
"*/-/S: - Co/ Anth Cobb"*
./ /o ` cw-err' t;.\ t > ILL
faot{TH'*/4 *r * a/ * S'Sz 'PZ Z&rJrtfS 0-i
>?b * */o C A.> -/A>*/. - \M///1S7in*sv
P3i0O<<w/.C/a*/*--
c-fi
___ 1
0726133
TOWOLDMONOQ48921
CENTRAL ENGINEERING DEDARTMENT
&////.
. ... /*
*>*.*
EQUIPMENT INFORMATION SUMMARY
"r
-r.
C to t OUll'Mf Hi IDEM IF i. *1 ION
NUMBER
/- /3 7
r*,\-r
.
. 0/0 ,
OESCRlPT ION OF EQUIPMENT ITEM f/A/l./''V ACjLuCT"
OTY
Si 2 E RATING MODEL. ETC
/ SbQO
MATERIAL OF CONSTRUCTION . t >*/ v
'PERATING WEIGHT
.POUNDS)
*r.
/
/%
'
7 //c-s /
REMARKS
% A *
'* it''* y\j>/'.'>r
PHu't 1
/- /?9
(!/ /' *.-7;
7/ K Mi**/*- P/Ta, rA
/ tZ'' S.//\ 'rt /!>,. S'**-A*
Sumur A c A/
l/isj
Ttictim'V'j- Sv/?6 Thu* /
Soo S/L.
ClHSoN C'f
4z"a/)*S/` />;<-
*7
b/S/A/A/tTi C&U
`K*
/^fi, /* *. A/* / S<sHt`v + " J.CA -
TZt'iBc
/-/JO
THZAjn) NIL fZfiT'
/- /40-co/
rfc ir. , The A.AMNC l
/ /OOdPftl/rS'Hi; 'i)vtruc 7#*n A*c K-/o
/ 7/i#0//l>
A`. 1 k /*. - />
72TAC
/V
/-///
Tnc\ f </, ' i f'o - -r'
b~J / 6(yco'
JHesj. V T-r/ 2*\ . , -- -
'" - '
?/>*.<, C-rOf-L
W 7Cr/' ' iV '' . v /
V
A" e'*~r ' ' /V v/,f A' . . -
/>/ ' >u:.*V"' /<*
-
0726134
TOWOLDMONOQ48922
CENTRAL ENGINEERING DEDARTMENT
EQUIPMENT INFORMATION SUMMARY
/ `"0 .. x.-r
CEO E QUU-MENT IDENTir 1C A1 lON
NUMBER
/- /je
OESCRIEM ION 0` E QUIPMENT 1 T EM
^jJTCTO'i 77*/VA'
OTV
SI ZE. RATING. MODEL. ETC
MAT ERIAL Of CONSTRUCTION
/:!?- *: -J /
'PERAT INC. POUNOS1
REMARKS
/
7800 7% ' 0/> *4S /*/</>
Tfio, 6 5A- STIC;
/eao
/>>;?/>`A>*/r.!, *> at-
&OC * 4^".
/-/" - / EST IMATED
ii* PRICE
V
/- Af.9
//.OJA'' IK.
/ .'s, fif -
/V
/-/4.^-orl /'forvfC , &Cv/i rotsL
rb "<
OvfA'Ai * Mr/-y^r
ss'<o '
c 7y, r
/ SoAf/'dbofr.y
/-/44 /-/4r
/-/4r,
%'*)/>aY SfA'fP
* <V -r'ca.
`V '
.
Sc?'<*:/* -V*
/ '. */4. AC! fityeztfa- it
'ft tA
'
/ ' 4A ", 34' Oh/S.-'.-A. ' /7&Sk<$//*/:
/ f- *
re:a :>
/-M7
aV^V^,'// '.''CA 'st- t C\.
/ a>~ , 3-r -> . :i.vA Trr.
rrre
V kV
4f A/
i ioi "ti : N-NCn
c [ n' ins
>. 10 ac mlocitcd
ll'IMl'ir, >11(11! * u L tO Bll M NORMA! CON T EN1 OR '**1 MATERIAL
0726135
TOWOLDMONOQ48923
CENTRAL ENGINEERING DETRIMENT
EQUIPMENT INFORMATION SUMMARY
I<DEL1>NTi:mOuelPAMT fIONNT
NUMBER
A/V *
DESCRIPTION OF EQUIPMENT ITEM
QT V
SI ZE. RAT iNG MODEL ETC
f/rA/7EK
/
MATERIAL OF CONSTRUCTION
T > A -
/
/-/c -6 /
.POUNDSI
REMARKS
/.y ... A-T
id i
ESTIMATED PRICE
( SI
V
7f/'/Cn;-f* . hsis*. /' 7/ja/K
/ /'/ro /44
OfrJr > /'r.r*
/- /Sr,
77tc<C/>, /s'/ />.-r
/
CjCa, 7K,;vS'/i--
/-/So-or,J S'fare*a, , 7//C* * 7A/ -
/
<ryi /oz ` rpa foc'C*? //&tvy'
2X>7y
t/s/gr/Sl
Szrs/.
A/.'.V/V A ^
4/
fiswf./
4
rrre
A/
/-/s/
/2C *
/-/St-t/ / /&' firmer
/ 24*Of
364 S'* *ns-
/A*#
M /, r: . - .... r-
/ +&SS S.'fif
T/rc
V V
. /. .i
0726136
TOWOLDMONOQ48924
CENTRAL. CNGINEERING DEARTMENT
EQUIPMENT INFORMATION SUMMARY
cr. D t QlllPMf NT IDENTlFIC A1 ION
NUMBER
77 <s<
3CC0 V
`
s*' . r-
/
/-LL-C f
'PEBATlNC
WEIGHT .POUNDS'
3
77-Cr^ V*r~ <
which EVE" UHMVItn
072613?
TOWOLDMONOQ48925
Aoa/h/ia /icu. Afr
5A*/rowAx 'A' C/e H/4 230-2
/saa/c Cmu>*- Ae C/s /4Z-Z
Ghloa/a/s
C/k
70'?
A/a //yoAOes# Me
Zf'O z-o
&vt>* Sb60 CmM Z/C/
3-~
6**
Afo#)* 74./
S4SO
%/hd/e *74-e
/fa/TAA. S'
7AU./A/6S
TStal ***/&*
Sm /<**
0,/t/SX <&`/4`A'/6
<5P/1- /lA*
ttscos/rr- CA Tt,,r K /kesss/te-Arri
/ woo
Z-
at
//Zoo /s /330
9-4 /o /iO /
3 4 sT 4 7 6 9 /O //
//ZOO
//ZOO
/r /S /s
32400 as- SO
924oo 2S
3SCO 3Soo 7000
3St>0 3b0
/OO /OO ZOO
/OO /OO
zsjoo
Y742S 548SG zso
I74ZS
94S ft*
7SS
94S 74S
9fS >2/60 36CCO Z/99S 42/00 26/6S /Z/60 96C00 &f?s
f-r /4S0
2/60 /4SO
100800 33/680 4112St
/coioo 33/080
/oo /ZS
2SO /2S
/oo /z-r
zso /zs
/O as /oo ze
m*. tyL /<? / 8-4 rjs^n /z 2.6
A90 /60 /s~ 2SO
2S0 MO /s zso
/ / A3S /3S /as / / /-3S /3S
0726138
TOWOLDMONOQ48926
Ag" /3 >7.... AT /6 /7
/y 20 2/ 22 23 24 ~~ '"1
/r 30
30
~2S
3&0 /oo"|
<*0 ;**? ao
5590
11_____ 300
I_____ ; .
_____ !
ir
2^X3
S/BOO
Tmzs
300
4oo
""
57f/0 SO 37900
/OO 37600 37600
1 (3?oo
/*#> aaw WW 300 8oo S/630 * 379SQ so 37900 *f330 /oo Titoo 37800
!
1 1 > *5
! 1V
1
<o :
I4l
I'S <
sj * O* l.
2/60
4/eo
33/490 _____ ! 462/60 Z?/0 //7S0 _____ j
izJ zd25P |
ZSO !
4& 3030 //OO
3060 3020
4tecax>
/4S0 /ZS
-j
/zr
Wd /2-0 /z-s 13 m, /IS /ZS
|5
*S 1!J 5
n'J^
>5
1Ij * s
!] 0
<2
69-9b/\
'Jo
mh ft WM WM |H
I eja 2SO
\7s j /oo | zoo
[Tar / [TjF\/-3S / '\t
/zo 4o
ggr w /60 370
033 ,003 .0/97 /
/zo /so /60
<49? /
/ZO 760
/
6 1
II 1i* S!4 H &
1 1
iVf1
/)pp
8
0726139
TOWOLDMONOQ48927
^7>-i
a
A
Stress Cfo.Q*/AZA/Tkt dru*
0MGO Sh*rOM/4X
77** -/V-CS O-SO
/soo /# icoo * 3e * SstfiT r
7Sr/9t.
AOO
($^>
/OO
?.oo
o-so
/ OO #4s
/font/ Snu. Crtue
'TiM&e5ru (^> o-so
/far t/fi Oanu. Otprr
@> @>
2-00 &-SO /OO
TbrAt-
/2-00ZZKS
0726140
TOWOLDMONOQ48928
fastML Ct/*c/rY* tes/ffirc// * Afrw/y/r * 6Ae4*r/<t #**. fO.OOO.CoO r 37,860/43/8*1*#* C#e &trt#//*&>* 3 * S3J~0#A3
r-/vsa
SO oo SO 00 007/X3
I/~M>S?\ f/UAL
fidAij/tura
ti/iPA*/ y
CntrtAL.&&##/** &r#isrtor#r
Sr^oo/s,
CKSAA/tC
| /ufUHTOtJ /iAMT
Atoce&s //<*/ i/A*K#t B/KiKXAU.4$ua/c#-
JcifD /fiQCU>A kPA*3/Q#
&?AW#
~W--------- Are fSYmico Ho-tf
/}&p
0726141
TOWOLDMONOQ48929
N
5CAU*. r mo'-o" 0726142
TOWOLDMONOQ48930
1
p,\Sl=_____
3( )'
fiROUND L&VfcL (E1V. *741-rt'}
ScfcLR t`lsl0`-o"
jWfKWT ARRAv*t He<->r yrvo
gouo ARPCkRR. g*P.KM'M
CEA.-J.oeo
5ca*-e- r=)o-o"
!3* H<P.dl>#4'n**v ^ '/'->Ai
'Wf 1 -fz
/ypp c
0726143
TOWOLDMONOQ48931
N
Third Le.VE.1 SCAUt I"*! O'-C/'
0726144
TOWOLDMONOQ48932
>V
-c
ai>\P.#t*r ARRAMggHBtJT 5TTJP/ SOLID A.ROCLOI8. EyfAf-^lOKJ
C&S-14&0
SOJLt I" - *o'-o"
Im *VlA
rtet 1 of JL
0726145
TOWOLDMONOQ48933
Appendix D
Building and Site Requirement
A. Building Size
Number of Floors - Three (includes ground and roof level)
Area per floor - 15D0 sq/ft.
Bay Size
- 20' X 18' - 2 required
- 30' X 18' - 1 required
- 12' X 18' - 1 required
B. Type of Construction
1. Structure - Open steel structure.
Roof to be reinforced concrete.
North wall to be enclosed with Monsanto Lustra span panels or equal.
Second level floor to be grating.
Finish on steel to be coating standard No. 502 or equal.
One stair at the east end of the structure.
2. Rooms
Control room ceiling will be acoustical tile.
Control room floor will be terrazzo to conform to existing floor.
Walls will be painted concrete block.
3. Personnel Service Facilities
None required.
4. Elevators
A freight elevator for moving bags of lime and rework to the operating floor is required. Capacity - 5000 lbs. Only one floor is served.
5. Heating and Ventilating
None required.
C. Electrical
There are no flammable materials handled in the immediate oper ating area. Classification is water resistant.
Normal grounding requirements.
Lighting requirements - Allow sufficient lighting for opera tions at the ground, operating and roof level.
0726146
TOWOLDMONOQ48934
Provide two welding receptacles at each operating level, six required. Provide two small tool outlet receptacles at each operating level, six required.
D. Maintenance Provisions
The coil in the furnace, Item 1-128, has to be accessible for repair. The submerged pump. Item 1-134, in the still pot. Item 1-129, must be installed so that it is readily removable.
E. Drainage
No spacial materials are required for drainage. Drainage ditches will be constructed in the ground level concrete pad and a curb installed around three sides of the entire pad.
F. Communications
None required.
G. Safety
No safety showers or eye wash fountains are required. No explosion barricades are required. No blow out panels are required.
H. Fire Protection
No sprinkler systems are required. No fire wall, fire hose stations, fire alarms, or foam systems are required. No building steel fireproofing is required.
I. Walks and Roads
None required.
J. Railroads
None required.
K. Parking Lots
None required.
L. Fences
None required. M. Dock Facilities
072A147
None required.
TOWOLDMONOQ48935
N. Facilities to be Relocated The control room wi11 be expanded and the existing chlorinator panel will be relocated into this new control roomTaMition.
O. Grading and Excavation The area to the north of Building 27 is a filled area and good soil is available at 12 to 15 feet from the surface.
P. Site Covering Rock covering in the areas around the site location.
0726146
TOWOLDMONOQ48936
Appendix E
Solid Aroclor Expansion Scope of Work
01 - Equipment
See Equipment Information Summary
02 - Instrument Items
See Instrument List and Summary
03 - Setting and Testing Equipment
Area accessible for truck and train unloading. High lift can be used to set larger units. The new elevator will be in stalled in Building 27.
04 - Setting and Testing Instruments
An addition to the present control room will be required to make space available for setting instruments. The new addi tion will be 20 ft. X 30 ft.
05 - Piling
None required.
06 - Excavation
For operating floor 100 ft. X 22 ft. X 1 ft.
2200 cu.ft.
For elevator pit
360 cu.ft.
6 ft. X 10 ft. X 6 ft
For structural piers
7700 cu.ft
Mfg. Area 7 piers X 8 ft. X 8 ft. X 12 ft. 5400 - 5400
Control Room 3 piers X 8 ft. X 8 ft. X 12 ft. * 2300
Backfill required
5000 cu.ft.
Remove spoil - Sheet piling may be required for shoring.
0726149
TOWOLDMONOQ48937
07 - Foundations
For Structural Steel
10 pads X 6 ft. square X 1.2 deep with 12 ft. column 1.5 ft. square
700 cu.ft.
Floor Slab - Reinforced Concrete
1100 cu.ft.
24 ft. X 90 ft. X 6" thick
Equipment Pads
120 cu.ft.
10 items X 6" Thick X 6 ft, X 4 ft.
Concrete Basin Within Floor Slab for drainage
450 cu.ft.
2 ft. wide X 1-1/2 ft. deep X 6" thick X 90 ft. long, 2 required
08 - SuoDorts, Platforms and Structures
Equipment Supports
55 tons
Grating Requirement
2000 sq.ft.
Handrails
400 ft.
Toeplate
400 ft.
Misc. Structural Supports
8 tons
Stair Requirement
One complete stairway for two levels
Control Room Building Frame
10 tons
Control Room Floor
300 cu.ft.
30 ft. X 20 ft. X 6*' thick
09 - Oth.r Building items
Floor Covering for Control Room
600 sq.ft.
30 ft. X 20 ft. terrazzo to conform to existing floor
Acoustical Ceiling for Control Room
600 sq.ft.
Windows for control Room - Four Units
5 ft. x 4 ft.
Doors for Control Room - Two Hollow Steel Units
3 ft. X 7 ft.
0726150
TOWOLDMON0048938
10 - Sprinklers
None required.
11 PiEjna
Item Service Material Size
1-101 Sant R
C.S.
2" X3"
Biphenyl C.S. 2''
Vent
C.S.
3"X4"
To It.103 Misc.
C.S. C.S.
3" X4" 3" X4"
Misc.
C.S. 2"X3"
Misc.
C.S.
2"X3"
Therm.Ret. Steam Cond.
C.S. C.S. C.S.
1" 1*5" 1"
Rmks. Jacketed Traced Jacketed
Jacketed Jacketed
Hose Jacketed
Hose Jacketed
Hose -
Length 75 ft. 75 ft. 35 ft.
30 ft. 2 ft.
2 ft.
2 ft.
50 ft. 40 ft . 40 ft.
Insul. Valves 1" 2 - Jctd, 1" 2 - CD3 1" 1 - Jctd, Vent 1" i - Jctd, --
-
-
1" 3 - FA37 1" 1" -
1-103 Chlor. Charge
C.S. 3" X4" Jacketed 100 ft.
1*5" 1 - Jctd,
1-104 Relief
C.S.
2"
Relief
C.S.
3"
Chlorine C.S. 3"
To It. 105 C.S. 3" X4" Jkt.
S.. S.Inner
Traced -
Jacketed
50 ft. 50 ft. 60 ft. 30 ft.
- 1 - CA46 -- 4 - DE411 2" 1 Jctd,
1-105 To It. C..S.Jkt. 3"X4"
106
S., S. Inner
To It. 125 C.S.
3"X4"
Sample
C.S. 2"X3"
Jacketed
Jacketed Jacketed
50 ft.
25 ft. 30 ft.
1-106 To It. C..S.Jkt. 3 " X4 "
104
S.. S.inner
To It. 116 C.S. 4"
Jacketed -
25 ft. 25 ft.
2" 2 - Jctd 2" 1 - Jctd 2" 1 - Jctd
2" No 2 - FA42
0726151
TOWOLDMONOQ48939
Item Service Material Size
Rmks Length Insul. Valves
1-107 To It. 108
c.s.. 4" 2 tracers 50 ft. 1*5" i - CA46
To HC1 Line C.S.. 4" 2 tracers 50 ft. 1*5" 2 - CA46
To It. 109 C.S..
4"
2 tracers 30 ft.
1*5"
1 - CA46
1-108 To It. 113
c.s,.
3"
- 20 ft. 1"
-
To It. 109 c.s,. 4" 2 tracers 15 ft. 1*5"
-
Drain
c.s..
1"
- 20 ft.
i - FA42
1-109 Vent Relief 200 psig steam In. Cond. Out
To It. 110
c.s,.
c.s,. c.s,.
c.s . c.s .
2"X3" Jacketed
2" -
1"
25 ft. 25 ft. 50 ft.
1" - 50 ft.
2" X3" Jacketed 30 ft.
1*5"
-
1*5"
1*5" 2"
i _ Jctd, -
2 - FA37
2 - FA37 i - Jctd
1-110 To It. 101
1-111 Vent Therm.In Therm.Out To It. 112
c.s,.
c.s . c.s . c.s . c.s .
2" X3" Jacketed 70 ft. 2"
2" _ 20 ft. _ 1*5" - 40 ft. 1*5" 1*5" - 40 ft. 1*5" 3" - 25 ft. 1"
2 - Jctd
_
2 - FA37 2 - FA37 i - FA4 2
1-112 To It.
108
1-113 To It.
Ill
c.s .
3"
c.s .
3"
- 50 ft. 1" i - FA42
- 50 ft. 1"
-
1-117 Relief Relief Chlorine
To It.118
c.s . 2" Traced
c.s .
3"
-
c.s .
3"
-
c.s. Jkt.3" X4" s.s.:Inner
-
50 ft. 50 ft. 100 ft. 30 ft.
-
-
2"
i - CA46 -
4 - DE41I i - Jctd
0726152
TOWOLDMONOQ48940
Item Service Material Size
Rmks.
1-118 To It. 119
C.S.Jkt. 3" X4" Jacketed S.S.Inner
To It. 123 C.S.
3"X4" Jacketed
Sample
C.S.
2"X3" Jacketed
Length 50 ft.
25 ft. 30 ft.
Insul. Valves. 2" 2 - Jctd
2" 1 - jctd 2" 1 - Jctd
1-119 To It. C..S. Jdt. 117 S.. S.Inner
To It. 123 C.S.
3"X4" Jacketed 4" -
25 ft. 25 ft.
2" . NO 2 - FA42
1-120 TO It. 108
To HC1 Line
C.S. C.S.
4" 2 Tracers 50 ft. 4" 2 Tracers 50 ft.
IV 1 _ CA46
-1*5" 2 CA46
1-121 Vent To It. 122 Steam In Steam Out
C.S. C.S. C.S. C.S.
4" 4" 1*5" 1*5"
Traced
-
30 ft . 30 ft. 50 ft. 50 ft.
1-122 To It. 119
To It. 123
C.S. C.S.
4" 4"
Traced 70 ft. Traced 30 ft.
1-123 To It. 121
TW In
TW Out
C.S.
C.S. C.S.
4" Traced 40 ft .
6", 3" - 50 ft. 6",3" - 50 ft.
-No 2 - FA42 i" i" -
NO 3 _ FA42
NO 1 - FA42
No 1 _ FA42
- 1 - EA46 - 1 - EA46
1-114 Vent
C.S.
4"
- 30 ft.
to It. 115 C.S.
4"
Traced 30 ft.
Steam In
C.S.
1*5"
- 50 ft.
Steam In
C.S.
IV
- 50 ft.
1-115 To It. 106
To It. 116
C.S. C.S.
4" 4"
Traced Traced
70 ft. 30 ft.
--
NO 2 _ FA4 2 1" -
i" -
NO 3 __ FA42
NO 1 - FA4 2
0726153
TOWOLDMONOQ48941
Item Service 1-116 TO It.
114
TW In
TW Out
Material C.S.
C.S. C.S.
Size 4"
6", 3" 6" 3"
Rmks. Traced
-
Length Insul. Valves 40 ft. No 1 - FA4 2
50 ft. 50 ft.
-
1 - EA46 1 - EA46
1-124 To It. 125
C.S.
2"
-
60 ft.
-
-
1-125 Steam In C.S.
IV
-
60 ft.
2
2 - FA37
Steam Out C.S.
IV
-
60 ft.
2
2 - FA37
Vent
Saran Lined Steel
6"
Traced 50 ft.
No
To It. 126 C.S.
3" X4" Jacketed 30 ft.
2
2 - Jctd.
1-126 To It. 129
1-127 Vent Drain
1-128 To It. 129
Gas In
C.S.
3"X4" Jacketed 75 ft.
2
2 - Jctd.
P.E.
Saran Lined Steel
6" 3"
_
50 ft.
_
50 ft.
-
C.S. 3"X4" Jacketed 30 ft. 2" 2 - Jctd.
C.S.
IV
-
50 ft.
"
2 - CD3
1-129 To It.
C.S.
18"
-
-
130
2" -
To It. 134 C.S. 3" X4" Jacketed 40 ft. 2" 2 - Jctd.
1-130 To It.
C.S.
16"
-
30 ft.
2"
-
131
To It. 129 C.S. 2" X3" Jacketed 10 ft. 2" Site Glass
To It. 141 C.S.
2"
- 30 ft.
1-131 To It. 132
C.S. 3"X4" Jacketed 20 ft. 2" 2 - Jctd. Site Glass
To It, 141 C.S.
2"
-
40 ft.
-
2 - FA37
0726154
TOWOLDMONOQ48942
Item Service Material
1-132 Vent
C.S.
Relief
C.S.
To It. 135 C.S.
To It. 133 C.S.
Steam In
C.S.
Steam Out
C.S.
Size
Rmks.
3"X4" Jacketed
4" -
3"X4" Jacketed 3" X4" Jacketed 1*5" -
1*5" -
Length 30 ft. 30 ft. 40 ft. 30 ft. 60 ft. 60 ft.
Insul. 2" 2" 2" 211 2"
Valves 1 - Jctd.
2 - Jctd. 2 - Jctd. 2 - FA37 2 - FA37
1-133 To It. 137
-
1-134 To It. 128
-
3"X4" Jacketed 110 ft. 2" 2 - Jctd, 3"X4" Jacketed 40 ft. 2" 2 - Jctd.
1-135 To It. 136
Steam In
Steam Out Water In
Water Out
-
-
3"X4" Jacketed 30 ft. 2" 2 - Jctd.
1"
-
30 ft.
1"
-
1"
-
50 ft.
1"
-
1"
-
50 ft.
1"
-
1"
-
50 ft.
1"
-
1-136 Steam In C.S.
Water In C.S.
Water Out C.S. Aftercond.
Water Out C.S. Intercond.
Vent
C.S.
2" 2" 2"
2"
3"
_
30 ft.
1*5"
-
-
30 ft.
-
-
-
40 ft.
-
-
-
40 ft.
"
-
-
20 ft.
-
-
1-139 Steam In C.S.
1*5"
-
50 ft.
-
-
Steam Out C.S.
1*5"
-
50 ft.
-
-
Vent
C.S.
3"
-
20 ft.
-
-
To It. 140 C.S.
2"
- 30 ft. 1" 2 - FA42
1-140 To It. 131
1-141 To It. 139
C.S. C.S.
2" 2"
-
70 ft.
-
2 - FA42
-
50 ft.
1"
-
072.6155
TOWOLDMONOQ48943
Item Service Material
Misc. Therm 14 Conn. In
C.S.
Therm 14 Conn.
Out
c.s.
Therm
C.S.
Sire IV
1*5"
6"
Rmks. -
Length Insul. Valves 500 ft. IV 30 - FA37
** 500 ft. IV 30 - FA37
- 500 ft. - 4 - FA37
12 - Ductwork
A 6 ft. X 6 ft. cabinet will be required for housing drums for draw-off of residue product for still pot.
13 - Electrical
Motors to be installed and wired:
Number
Horsepower
12 55 1 7*s 2 10 3 15 2 20 1 25 1 30 1 50
Allow for remote pushbuttons and alarms for 10 motors.
Lighting required in operating area:
Ground Area, Operating Area, Roof Area,
18 ft. X 18 ft. X 18 ft. X
82 ft. 82 ft. 82 ft.
1476 ft2 1476 ft2 1476 ft2
14 - Site Preparation
None required.
15 - Sewers
1. 50 ft. of 4" permanite sewer pipe with one tie-in to exist ing 8" sewer which runs west of Building 27.
2. 150 ft. of 304 S.S. guttering around the top of the new structure with 3-4" downspouts, each 30 ft. long
0726156
TOWOLDMONOQ48944
16 - Underground Mains
None required.
17 - Yards. Roads and Fencing
None required.
18 - Railroads
None required.
19 - Insulation
Piping - Refer to Code 11
Equipment - As below - material Standard #100 Weatherproof, Std. #65
Item
1-101 1-104 1-107 1-109 1-111 1-117 1-120 1-125 1-129 1-130 1-132 1-139 10 Pumps
Area
250 ft2 200 ft2
50 ft2 250 ft2
80 ft2 200 ft2
50 ft2 550 ft2 550 ft2 150 ft2 350 ft2
80 ft2
Thickness
2" 2" i" 2" iv 2" 1" 2" 4" 3" 2" IV 2"
20 - Painting
Coating Standard #502, Epoxy System.
All uninsulated piping, air, water, gas.
Supports for Items 106, 113, 116, 119, 123, 128, 141, 142, 132, 135.
0726157
TOWOLDMON0048945
21 - Walls, fasonrv, Roos and Roofing
Concrete roof deck for mfg. area - reinforced concrete, 20 ft. X 90 ft. X 5" thick
Concrete roof for control room - reinforced concrete, 20 ft. X 35 ft. X 5" thick
Concrete wall for control room - concrete block, 3 walls, total feet - 70 ft. X 15 ft. high
Concrete enclosure for elevator - concrete block, 4 walls, total feet - 30 ft. X 25 ft. high
Built up 4-ply roof for control room, 20 ft. X 35 ft.
North wall of mfg. structure will have Monsanto Lustra Span panels for a distance of 80 ft. and height of 12 ft. in each level.
750 cu.ft. 290 cu.ft. 1050 sq.ft. 750 sq.ft. 700 sq.ft. 1920 sq.ft.
90 - Dismantling
1. North wall of Building 27, approximately 1500 sq. ft. of brick wall.
2. South wall of present control room, 450 sq.ft, of concrete block wall.
3. Shed to south of present control room, approximately 600 sq.ft, of transite roof and steel platforms inside shed.
4. Biphenyl heater on Still No. 1. This is a unit heater in the shed.
92 - Repairs Expense
Replace existing head on Item 535. This is a 2000 gallon vessel and requires a new 78" O.D. carbon steel head.
93 - Relocation and Modification Expense
1. Remove and relocate Item 205, a 14` dia. X 10' high storage tank with coil and agitator.
2. Remove and relocate stairway to the north of Building 27.
3. Remove and relocate 10 ton stand-up tube air-conditioner which is now in the south section of the control room.
4. Remove and relocate a 20 ft. chlorinator panel from its existing position in the present control room to the new control room.
5. Remove the present 1268 flaker (24" X 48" unit) and replace with a new unit. This unit will be relocated to an area just east of the present flaker.
0726158
TOWOLDMONOQ48946
APPENDIX E - Amendment No. 1 Scope of Work - CEA 2080
07 - Foundations
For Elevator Pit (Reinforced Concrete)
150 cu. ft
Supports, Platforms and Structures
Equipment Support For Item 152
6 tons
Grating Requirement For Item 152
225 sq.ft
Handrails
60 ft.
Toeplate
60 ft.
Stair Requirement
One Stairway For One Level
11 - Piping
Item 1-152
Service Material Size
Charge
c.s. 3,,X4"
Charge
c.s. 2" X3"
Therminol c.s.
1*5"
Vent
c.s. 3"X4"
Overflow c.s.
3"X4"
Outlet
c.s. 2" X3"
Rmks. Length Insul. Valves
Jacketed 125 Ft. 2"
1 - Jctd
Jacketed 125 Ft. 2"
1 - Jctd
-
200 Ft. IV
2 - FA5
Jacketed 30 Ft. -
-
Jacketed 30 Ft. 1*5"
-
Jacketed 50 Ft. 1*5"
1 - Jctd
12 - Ductwork
A 6 ft. X 8 ft. X 10 ft. hopper will be required under the new flaker.
13 - Electrical
Use PVC coated conduit.
19 - Insulation
Item 1-152
Area 320 ft2
Thickness 2"
90 - Dismantling 2
A section of floor in Building 27 - Area 400 ft for 1268 flaker.
072A159
TOWOLDMONOQ48947
92 - Repairs Expense 5. Repair or replace section of floor at new 1268 flaker.
93 - Relocation and Modification Expense Remove Item (5) from original scope and replace with the following: 5. Relocate 18" I beam to south of control room. This beam is 40 ft. long and will be moved south approximately one foot. 6. Relocate 2 - 6" IPS tower water lines to south of control room - Total feet = 100. 7. Relocate miscellaneous 2" IPS pipe to south of control room - Total feet = 100.
0726160
TOWOLDMONOQ48948
2 ae
\ r*T
/a /7 2 4 _ ~roZ2Z T*4Tt Y 1
/i /
\____ LrH
^--Li--J\2--iF^--`
f--L
P<CO(S.S
$U/P.
_TTUC T.
Or/i/rv _ fz/AO7J>Kl
P/ P/UOr /A/suiAr>OAj
/*J3 T*.
c*c.
<
-
p 1 _JV
a/6>!
< 6*J
< <i U/A. A*
(Qua **Cri A*J/a.
?^r !--<s ?------
\
/ >- 1 i
>-- i i
X if li i i 11
\ 1 ii 2tevt iLOA Pt/*
X nAuUa/t
HAJT 06.K-I
&J
\ \ oa TAiK 1 ~T7
5
(L_
1 / V\ Pac '/JA.% dU/A Mu T
1 1,
1 1i j A ttc U.
</
A *<rV
VU
PATA
Pe. 'tecA fSk L/V6 i s. AP CP. AAAI
>s
L Tcctr Y i
r
sret* : r<ri/v
'1 1 1
y
/ \ J? TUCl
1 \rftu C.T.
rr rqX ------( )z>*.
I ,c i II
P, STttL ------ \
/ 4$l"i1^r\2S\'tiSt/
P i
rcoo*
n
ItA rA/.
>r L.
\
"1Au i Ptu
/------ i ^
rs
Co a/STi UCT
\f&r AJ. Att
\j3l_ ycr. r OTA/S
\e.a
1 l 1j
1 U-
/UA
-<
\P/P. y
PC*
2
WAS/ ----- ^
/
1
?/e.cCr iouu
ice. Joe. 1 cy <aIlo
La /
Qlac
-< X"1
>-A
*S
>-- ?-- \ ^ 1 1 11
.Mol L t
0, '/ASj 'cffL, \ ^ A P/p/. U& 3
1
11 l1
1
< J P/o /AJeTr
I1^ 1 1 .Pu.
1|
11
i / P \f/)a1 \ //V IT/Zb MtJ r >> -S'** Po etcPa S. /
a.
i 1 -X it ---< ^l- / }.S /A srte /M. jr m e'piA/ '/je-r
1 .hci ff l1
our LC rrr/Ai sre.. Oust fOA DC
. ,
1)1/ L
< )-- >=t=_j --<1 i1
1
>
i1
1
~<L_ _1_
s L& CTZt AL teste A/* / 'u&C SAJa '-------
Is 1 P as. ^ > .ll/STA 'l I
V ilc TtC l n vJG'S. f
1 fA.C C.
f P Mvv l/JCr \ ------<s
_
0726161
TOWOLDMONOQ48949
0726162
TOWOLDMONOQ48950
Monsanto
General Offices - St. Louis
January 24, 1969
Project Loss Prevention Report 69-7 CEA 2080
Mr. R. S. Yates
cc R. E. Howard G. O. Hunt P. K. Ward - Anniston S&PP Project File S&PP Location File
COPIES TO THOSE PRESENT
R. J. Green W. B. Howard R. M. Kountz W. E. Voss - Anniston R. S. Yates
DATE AND PLACE OF MEETING Missouri.
January 23, 1969, Creve Coeur,
CEA 2080 Alabama.
Expand Solid Arochlors, Anniston Plant, Anniston,
This project is increasing the plant capacity for manufacture of solid arochlors from 9.6 to 29.6M ppy. The project capital is approximately $1.03M. Completion target is December 15, 1969.
PERSONNEL
1. Chlorinated Biphenyl Content of Product
An overall
project objective is to minimize chlorinated biphenyl
content in the solid arochlor 5460. This is needed for
FDA approval of the material, since it is used in hot-
melt adhesives in food packaging. It is also used in
plasticizers.
2. Elevator
It is planned to install an elevator to
handle both freight and passengers. The elevator will
have the capacity for 5000 pounds and will likely be
hydraulically operated. It was agreed that the project
manager will review the elevator design and safety con
trols with Mr. George Gorbell.
3. Lime Addition
Lime is added to the still pot from
50 pound bags. This size bag is considered safe for
personnel handling.
0726163
TOWOLDMONOQ48951
R. S. Yates
2 January 24, 1969
MECHANICAL
An external gas-fired heater is used for the
still pot. Combustion safeguards are planned by the project;
these will include a Honeywell protecto-glow unit. There will
also be a pilot interlock. The combustion safeguards should
be reviewed with Mr. George Ostroot when the heater design is
further along.
In addition, some process safety provisions will be incorporated
in the heater. A high temperature sensing unit on the process
material coming out of the furnace will shut down the burner
.
on high temperature. If the circulation through the heater
stops, an alarm will sound. Standard instrumentation will be
employed for these functions.
PROCESS
1. Alarms and Interlocks
The operation of the chlorinators
will be sequence controlled. Chlorination starts at a
temperature of about 150C. As the batch progresses the
sequence controller steps the temperature upward so that,
at the conclusion of chlorination of a batch, the tempera
ture is in the range of 250-255C. The temperature will
be recorded in the chlorinator; an alarm will be actuated
at high temperature. It was agreed that the project will
consider use of a differential temperature alarm, based
on the desired temperature at any stage of the batch, rather
than a high temperature alarm which must function at a
temperature higher than the maximum batch temperature. It
was believed that this type of alarming would be a better
investment of money than the addition of a second high
temperature alarm on the reactor, and located in the vapor
discharge from the reactor.
There will also be temperature detection in the arochlor circulating line on the chlorinator. A high temperature in this line will give an alarm and will also close the chlorine supply valve. The complete closure of the chlorine supply valve will not be possible because chlorine will come from tank cars rather than from the chlorine unit.
If flow should cease in the arochlor circulating line there will be an alarm and the chlorine valve will be closed.
There will also be an alarm if the therminol circulation should stop.
0726164
TOWOLDMONOQ48952
R. S. Yates
3 January 24, 1969
Other alarms include the following: a scale alarm to prevent overcharge of the weigh tank; a low temperature alarm on the chlorinator at 120C; water coolant to the
therminol cooler to prevent too low a water temperature;1 a signal when the batch is 80% chlorinated in order to signal the time to initiate sampling; high (80C) and low (60c) temperature on the circulating therminol. The project is also considering installation of a nuclear instrument on the process circulating line at the chlorinator to determine density; it is hoped that this density figure can be correlated with softening point. If the correlation works out on a present plant test, the equipment will be
installed.
2. Operating Time
The operating time of the present unit
is only about 74%. Downtime on a chlorine plant has been
a part of the problem; the new purchased chlorine arrange
ment should help this. Another part of the problem has
been maintenance. It is also hoped that this can be im
proved in order to improve the on-stream factor.
3. HCl Scrubber
In order to minimize the HCl venting to
the atmosphere the project will add equipment for improved
HCl absorption and scrubbing.
4. Gas Fired Heater Operation
The firing rate on the heater
is manually indexed on a flow controller on the gas to the
burner. This type of control has proved adequate with the
present plant installation and is believed to be adequate
for the new heater. The project will also try to design
the heater coils in such a manner as to simplify coil re
moval for the furnace. The furnace coils can be expected
to burn out approximately annually. This is considered a
normal maintenance item and presents no major problems.
5. Residue Removal
If the residue is removed from the
system in the manner used at present, the fume hood venting
provisions will be improved over those at present. The
project also plans to try to develop a system for flaking
the residue.
BUILDING AND FIRE PROTECTION
An 181 x 90' x 2 level bay
will be erected adjacent to the north wall of Building No. 27.
The construction will be open steel frame with reinforced fiber
glass polyester wind-breaks, concrete slab roof and steel grate
flooring at the first level above ground level.
Hydrant #13 with hose house and hydrant #19 with attached monitor nozzle are adequate fire protection. No sprinklers or fire proofing are needed.
0726165
TOWOLDMONOQ48953
R. S. Yates
4 January 24, 1969
A 20' x 30' extension to the existing control room will be erected at the 16 ft. level. The construction will be con crete block walls and non-combustible roof. No fire protection is needed.
LOSS EXPOSURE
The maximum probable loss was considered to
come from loss of the heater for the still pot as a result of
explosion in the fire box. It was considered that approximately
six days will be required to re-brick and repair the heater. A
spare coil will be kept in stock.
It was estimated that the repairs would cost about $10M. Six days were estimated to be sufficient for the repairs. The business interruption loss during this period of time would be approximately $45M.
LOSS PREVENTION REVIEW CHECK LIST
Attached to R. S. Yates'
copy of this report is a copy of Form G-1425, Loss Prevention
Review Check List, which can be used as a safety check list
for this project.
LOSS PREVENTION REVIEW BY PLANT
The S&PP Branch of CED can
not review design prints and construction steps in detail as
this project progresses. S&PP requests plant personnel, in cluding plant safety personnel, to hold additional safety
reviews at the plant, to follow the development of design prints, and to check the progress of construction in order to
make maximum contributions from their experience with these operations to the CED personnel involved in execution of this
project.
SAFETY MANAGER
G. 0. Hunt will be Safety Manager for this
project. Please contact him for additional safety reviews
needed during design.
R. J. Green
bjr Attachment
:
W. B. Howard 0726166
TOWOLDMONOQ48954