AmericanWaterWforks Association
ANSI / AWWA C402-77 (Revision of C402-7S)
AWWA STANDARD
for
ASBESTOS-CEMENT TRANSMISSION PIPE.
18 IN. THROUGH 42 IN.. FOR WATER
AND OTHER LIQUIDS
^
fAMERICAN NATIONAL] iiSTANDAROHP
| )
First approved by AWWA Board of Directors Jan. 26, 1975. This edition approved Jan. 30, 1977.
Approved by America,% National Standards Institute. Inc.. Nov. 28, 1977.
COMPLIMENTS OF
ATLAS PIPE
AMERICAN WATER WORKS ASSOCIATION
6666 West Quincy Avenue, Denver, Colorado 80235
CAPCO JEN 0019867
Committee Personnel
The Standards Committee on Asbestos-Cement Pressure Pipe, which reviewed and ap ved this standard, had the following personnel at the time of approval:
R. S. Bryant, Chairman J. L. Warden, Vice-Chairman T. R. Gillen, Secretary
Consumer Members
S. C. Baker, Naval Facilities Engineering Command, Alexandria, VA
P. J. Brady, Director of Utilities, Portsmouth, VA
(NAVFAC) (AWWA)
R. S. Bryant, Department of Water & Power, Los Angeles, CA (ASCE)
F. G. Denson, Works & Operations Department, Winnepeg, Manitoba
(AWWA)
J. R. Hendrick, Water Department, Fort Worth, TX
(AWWA)
J. E. Johnson,* U.S. Bureau of Reclamation, Denver, CO
(BUREC)
R. W. King, Water Utilities, San Diego, CA
(AWWA)
R. A. Marchand, Water Department, Warren, OH
(AWWA)
J. L. Warden, U.S. Bureau of Reclamation, Denver, CO
(BUREC)
General Interest Members
G. C. Anderson, Insurance Services Office, New York, NY R. A. Barrows, C. E. Maguire, Inc., Waltham, MA V. R. Bickel, Department of Environmental Health,
Albuquerque, NM S. L. Bishop,* Metcalf & Eddy, Boston, MA C. L. Frick,* Insurance Services Office, New York, NY R. S. Holmgren, Jr., James M. Montgomery, La Jolla, CA F. A. Obert, Metcalf & Eddy, Boston, MA J. S. Slicer, Factory Mutual Research, Norwood, MA M. R. Suchomel, Underwriters Laboratories, Northbrook, IL W. Taggart, Wright-McLaughlin Engineering, Denver, CO
(ISO) (NE-WWA)
(AF(WA) (NEWWA)
(ISO) (AWWA) (WPCF)
(FMR) (UL)
(ASCE)
Producer Members
A. E. Alpine, Cement Asbestos Products Co., Birmingham, AL F. T. Duffy, The Flintkote Company, Akron, OH T. R. Gillen, Johns-Manville Sales Corp., Denver, CO J. C. Jackson, Association of A/C Pipe Producers,
Washington, DC A. I. Leff,* Certain-Teed Products Corp., Valley Forge, PA W. R. Seipt, Certain-Teed Products Corp., Valley Forge, PA
(AWWA) (AWWA) (AWWA)
(AACPP) (AWWA) (AWWA)
Alternate.
Copyright 1977 by American Water Woilcs Assn. Printed in US
ii
CAPCO JEN 0019868
Table of Contents
SEC.
Foreword
I History of Standard .................. II Information Regarding Use of
This Standard........................... III Major Revisions...........................
Standard 1 General ............................... 1.1 Scope ................................................. 1.2 Definitions ......................................
1.3 Affidavit of Compliance ...........
2 Materials ............................ 2.1 Composition ................................... 2.2 Physical Requirements ............. 2.3 Chemical Requirements.............
3 Design............................... ............ 3.1 Pipe Classifications ....................
3.2 Pipe Diameters............................. 3.3 Pipe Lengths ................................. 3.4 Couplings ........................................ 3.5 Joints ............................................... 3.6 Wall Thickness.............................
4 Workmanship and Finish .,
4.1 Imperfections .......................
PAGE
.v
. vi . viii
.I .1 .1
.2
.2 .2 .2
.3
.3 .3 .3 .4 .4 .4 .4
.4 .4
SEC.
PACE
5 Inspection, Testing, and Rejection ..........................................
5.1 Inspection ................................................ 5.2 Physical Test Requirements........... 5.3 Retests (Physical) and Rejection .. 5.4 Test for Uncombined Calcium
Hydroxide ........................ '................ 5.5 Test Records............... -........................
6 5 5 7
7 9
6 Marking and Delivery.................. 6.1 Marking ................................................... 6.2 Preparation for Shipment ................
9 9 9
Tables F.l Asbestos-Cement Pipe Type
Recommended for Internal Water Aggressiveness ..................
vii
F.2 Aggressiveness of Nonsulfate Acidic Soils to Asbestos-Cement Pipe.................. vii
F.3 Asbestos-Cement Pipe
`\
Type-Designation Chemical}
Resistance to Nonacid Soluble
Sulfates in Water and Soilt.... viii
1 Pipe Classification...................... i.......... 2
2 Design External Load............../..... 3
3 VVall Thickness Tolerances ................ 4
4 Hydrostatic Tests .................................... 6
Figures 1 Crushing Test Assembly......................
6
iii
CAPCO JEN 0019869
Foreword
This foreword is for information only and is not a part of C402':
I--History ol Standard
A new pipe material consisting of an intimate mixture of Portland cement and asbestos fibers was introduced to the North American market in 1931 following a number of years of usage in other countries, particularly Italy.
In the ensuing years, this type of pipe gained popularity, and in 1949 AWWA established a committee on standard specifications for asbestos-ce ment pipe under the chairmanship of S. M. Clarke of Greeley and Hanson, Chicago.
The committee developed a standard for asbestos-cement water pipe, which was approved by the AWWA Board of Directors as a tentative standard, AWWA C400-53T, on May 15, 1953. In 1958, the committee was reactivated as Committee 8340D on Asbestos-Ce ment Pipe under the chairmanship of Roy H. Ritter, Whitman, Requardt and Assocs., Baltimore, to review sev eral suggested changes and to recom mend revisions to the standard. The committee produced a revised standard adopted by AWWA as C400-64T on Jan. 27, 1964. It was advanced to "standard" without revision on Jul. 2, 1965.
In early 1968, the committee was re activated as the Standards Committee on Asbestos-Cement Pipe to review and revise all of the AWWA stan dards on asbestos-cement pipe. The committee produced a revised standard
approved by the Board of Directors on Jan. 31, 1972, designated as "AWWA
Standard for Asbestos-Cement Pres
sure Pipe for Water and Other Liq uids, C400-72."
In the winter season of 1972-1973 the committee was reorganized and enlarged to include representation of national organizations having an inter est in the scope of the committee and wishing to participate in the work. The reorganized committee reaffirmed C400-72 without revision so that it could be presented to the American National Standards Institute for des ignation as an American' National Standard.
In 1975 the committee produced a revised standard approved by the AWWA Board of Directors Jan. 26, 1975, designated as AWWA C400-75, "Standard for Asbestos-Cement Pres sure Pipe, 4 in. Through 24 in. for Water and Other Liquids." At the same time a new standard was pro duced by the committee and Approved bv the AWWA Board of Direc ors des ignated as AWWA C402-75 "Stan dard for Asbestos-Cement T -ansmission Pipe, 18 in. Through 42 in., for Water and Other Liquids."
The asbestos-cement pipe manufac turers had developed a new series of pipe classifications that was larger and designed to give greater freedom of selection to design engineers. This is of particular significance for large di ameter pipeline projects where the sav ings in material cost can exceed the increased cost of more detailed design, better control of methods of installa tion, and provision of surge controls when justified.
The standard, AWWA C402-75,
was developed to provide the user
with a ready reference and specifica
tion for this type of pipe known as
transmission pipe.
CAPCO JEN 0019870
VJ A-C TRANSMISSION PIPE--18 IN. THROUGH 42 IN.
The possibility of confusion between the two standards. C400 and C402, was carefully reviewed by the commit tee. The result is this edition of C402, which maintains the sizes covered from 18 in. through 42 in. C400 has bean revised simultaneously and covers sizes 4 in. through 16 in. There is now no overlap in sizes.
II--Information Regarding Use of This Standard
II.A General. When ordering pipe covered by this standard, local instal lation and operating conditions should be considered to determine the classifi cation and type of pipe to specify. Also, certain other items must be specified to describe completely the pipe required.
It is recommended that, for large diameter pipeline projects, the pur chaser evaluate local installation and operating conditions, operating pres sures and surge pressures, trench loads, and surface loads when deter mining the strength classification to be used.
A proposed AWWA C403. "Stan dard Practice for the Selection of As bestos-Cement Transmission Pipe," is under consideration at the present time by the committee.
Note: The purchaser is referred to AWWA C401 (formerly AWWA H2). "Standard Practice for Selec tion of Asbestos-Cement Distribution Pipe," for guidance in designing trans mission pipe to fit his installation and operating conditions. Attention is di rected to the fact that selection curves and related data in the current edition of AWWA C401 are applicable to pipe covered by AWWA C400-77, "Asbestos-Cement Distribution Pipe,
4 in. Through 16 in., for Water and
Other Liquids." not to transmission
pipe covered by this standard. The
purchaser is advised to consult the
manufacturer pending the issuance of
the proposed AW\VA C403.
The purchaser is referred to AWWA
C603, "Installation of Asbestos-Ce
ment Pressure Pipe." for guidance in
the laying of the pipe.
II.B Flexural load test. Flexural
load tests are not required (Sec. 2.2.L
5.2.3). For large diameters, the wall
thicknesses increase to a point at which
the flexural strength is not a control
ling factor, and therefore routine test
ing is not required.
II.C Ty[>c of pipe.. The following
criteria are presented for determining
the type of pipe to be used under var
ious soil and water conditions. Each
condition should be considered sepa
rately even though each may exist in
combination with others.
These criteria are based on-expo
sures within the temperature range of
4Q-S0F (5-2SC). For pipe exposures
to temperatures beyond these Ijmits,
consult the manufacturer.
./
The following criteria are refer
enced as:
1. Internal water (Table F.l). 2. External water (Table F.2). 3. Xonacid soluble sulfates--in
ternal and external (Table F.3). 4. Acid soluble sulfates--internal and external.
II.C.l Internal water. Aggressive ness of water transported through as bestos-cement pipes is related to the type-designation of asbestos-cement pipe suitable for such use in Table F.l. Aggressiveness of water is de fined as follows:
CAPCO JEN 0019871
I
FOREWORD
vii
(a) Highly aggressive: pH + log (AH) < 10.0
(b) Moderately aggressive: pH + log (AH) = 10.0-11.9
(c) Nonaggressive: pH + log (AH) > 12.0
where
pH = Index of acidity (or alkalinity) of the water--standard pH units
A = Total alkalinity--ppm as CaCOj H = Calcium hardness--ppm as CaCOi
It should be recognized that water that has a pH + log (AH) less than or equal to 10 is an extremely aggres sive water and would be very corro sive to almost all materials found in a typical water system, including the plumbing in consumers' homes. Such waters should be treated to increase pH or hardness to protect the entire network of materials that make up the system. In the event such water treat ment is not to be undertaken, the man ufacturer of each item used in the water system should be consulted for recommendations regarding the use of his product in an extremely corrosive environment.
Note : The expression pH + log (AH) is a modification of the Langelier Index. It has been prepared so that the aggressiveness of the water may be determined easily. A reason able comparison of the two would be as follows:
pH + log (AH)
Langelier Index
Highly aggressive water
Moderately aggressive water
Nonaggressive water
<10.0
10.0 to 11.9 >12.0
< -- 2.0
--2.0 to --0.1 >0
TABLE F.l
Asbestos-Cement Pipe Type Recommended, for Internal Water Aggressiveness
Internal Water Aggressiveness
Highly aggressive Moderately aggressive Nonaggressive
Recommended Pipe Type*
t II I and II
* Type I--no limit on uncombined calcium hy droxide; Type II--1.0 per cent or leas uncombined
calcium hydroxide. t The serviceability of pipe for such applications
should be established by the purchaser in conjunction
with the manufacturer.
TABLE F.2
Aggressiveness of Nonsulfate Acidic Soils to Asbestos-Cement Pipe
Water Conditions Within the Soil Environment
Minimum pH of Acidic Soils When Using
Asbestos-Cement Pipe
Type I Type II
Essentially quiescent Mildly fluctuating Rapidly moving or
grossly cyclic
5.0 5.5
. 6.3
4.0 5.0
5.5
II.C.2 External water. A Jgressiveness of external water (water within the soil environment) in relation to as bestos-cement pipe as shown in Table F.2.
The guidelines for the use of as bestos-cement pipe in nonsulfate acidic soils are based upon minimum pH factors alone. Asbestos-cement pipe may or may not perform satisfactorily in acidic soil environments having pH values below those listed in Table F.2. To determine the suitability of asbes tos-cement pipe in soils having lower pH values, each situation should be evaluated individually, taking into con sideration all aspects of soil environ ment that affect asbestos-cement pipe corrosiveness.
CAPCO JEN 0019872
viii A-C TRANSMISSION PIPE--18 IN. THROUGH 42 IN.
Water
Soil
Sulfate Aggressiveness Classification
Water Soluble Sulfates--ppm SO,
Water Soluble Neutral Sulfates--ppm SO,
Nonaggressive Mildly aggressive Moderately aggressive Highly aggressive
150 and less 150-1500
1500-10 000 10 000 and greater
1000 and less 1000-2000
2000-20 000 20 000 and greater
II.C.3 Nonacid soluble sulfates-- internal and external. Aggressiveness of nonacid (pH > 7.0) soluble sulfates in water and soils is related to the type-designation of asbestos-cement pipe suitable for such use in Table F.3. Sulfate aggressiveness in water and soil can be classified as indicated above.
II.C.4 Acid soluble sulfates--inter nal and external. Aggressiveness of acid (pH < 7.0) soluble sulfate wa ters and soils to asbestos-cement pipe must be evaluated independently. Acid sulfate soils and waters, whether the acid is inorganic or organic, must be evaluated independently of the criteria and guidelines set forth in paragraphs II.C.2 and II.C.3 and must take into consideration soil permeability and other factors. For guidance, consult the manufacturer.
II.D Supplementary specifications.
The following information summarizes the conditions and items that the pur chaser should consider when prepar ing his supplementary specifications and lists the sections in the standard where they may be found.
1. The standard used; that is.
AWWA C402-77.
2. Affidavit of compliance, if re
quired (Sec. 1.3).
3. Type of pipe to be furnished
(Sec. 2.3 and Foreword II.C).
4. Classification of pipe (Sec. 3.1).
5. Nominal inside diameter (Sec.
3.2). 6. Lineal feet to be furnished in
standard and random lengths
(Sec. 3.3).
7. Number, size, type, classification,
lengths, and extent of machining
of special short lengths (Sec.
3.3.3).
8. Whether inspection by the pur
chaser (Sec. 5.1) and special
marking (Sec. 6.1.4) are-'re
quired.
|
III--Major Revisions
Major changes to the 1975 standard made in this revision are:
1, A more detailed description of aggressive soil and water criteria has been added in the Foreword, Sec. II.
TABLE F.3
Asbestos-Cement Pipe Type-Designation Chemical Resistance to Nonacid {pH = 7.0) Soluble Sulfates in Water and Soils
Type Designation I*
Chemical Resistance to Nonacid Soluble Sulfates in Water and Soils
Will be attacked in various degrees by all but the nonaggressive levels of sulfate concentrations in waters and soils.
II Resistant to all levels of soluble sulfates.
* The guideline criteria for sulfate resistance of Type I pipe were taken from the Concrete JManual. 8th edition. Bureau of Reclamation. 1974. Sulfate resistance here applies to alt soluble sulfates regardless of the cation.
CAPCO JEN 0019873
FOREWORD
IX
2. The lot definition of paragraph 1.2.3 has been revised to define more clearly the quantity of pipe manufactured by size versus time.
3. Paragraph 5.2.5 Machines for Testing defines the machines used
in the various physical tests and also allows couplings to be hy drostatically tested with a rubber bladder inside the coupling at ten times the classification of the coupling.
A
CAPCO JEN 0019874
AmericanWaterWxks Association
AWWA C402-77 (Revision of C402-75)
AWWA Standard tor
Asbestos-Cement Transmission Pipe, 18 in. Through 42 in., for Water and Other Liquids
Section 1--General
Sec. 1.1--Scope
This standard covers nine pressure classifications of Type I and Type II asbestos-cement pipe, 18-42 in. in di ameter. for water and other liquids, to be laid underground in public and pri vate rights-of-way.
1.1.1 Use. Asbestos-cement trans mission pipe is to be used in pipe sys tems having relatively predictable flows and few appurtenances, which permit reasonable hydraulic analyses, includ ing those for surge pressures.
Sec. 1.2--Definitions
Under this standard, the following definitions shall apply:
1.2.1 Inspection. Inspection of the pipe and the tests by the inspector.
1.2.2 Inspector. The authorized representative of the purchaser, en
trusted with the duty of inspect ng'pipe produced and tests performec under this standard.
1.2.3 Lot. A lot as used herein for pipe 20 in. in diameter and smaller is defined as all pipe of any one classifi cation, type, and size manufactured on any. one machine in 24 hr but not to exceed 300 lengths. A lot as used herein for pipe larger than 20 in. in diameter is defined as all pipe of any one classification, type, and size manu factured on any one machine during a period of consecutive working days not exceeding seven days but not to ex ceed 300 lengths.
1.2.4 Manufacturer. The person,
firm, or corporation that manufactures
the pipe. 1.2.5 Purchaser. The person, firm,
corporation, or government agency en
tering into a contract or agreement to
CAPCO JEN 0019875
2 A-C TRANSMISSION PIPE--18 IN. THROUGH 42 IN.
purchase pipe according to this stan dard.
Sec. 1.3--Affidavit of Compliance
The purchaser's supplemental spec ifications may require an affidavit of
compliance from the manufacturer, whether factory inspection has been required or not, to the effect that the materials furnished under the purchas er's order comply with all applicable requirements of this standard.
Section 2- Materials
Sec. 2.1--Composition
Asbestos-cement pipe shall be com posed of an intimate mixture of either: (1) portland cement or portland blast furnace slag cement and asbestos fiber with or without silica; or (2) portland pozzolana cement and asbestos fiber. Both (1) and (2) can be with or without the addition of curing agents. The pipe shall be formed under pressure and cured. The fin ished pipe shall be free from organic materials.
2.2.2 Bursting strength. Each length
of pipe and each coupling sleeve ishall have sufficient strength to withstand the design internal pressure indicated for its classification in Table 1 when subjected to the hydrostatic test pro cedure specified in this standard.
TABLE 1 Pipe Classification
Classification
Design Internal Pressure psi
Sec. 2.2--Physical Requirements
2.2.1 Flexural strength. Because only improperly bedded and improp erly installed small diameter pipe is susceptible to adverse flexural loading, there is no flexural requirement for
30 35 40 . 45 SO 60 70 80 90
300 350 400 450 500 600 700 800 900
large diameter pipes.
CAPCO JEN 0019876
SECTION 3--DESIGN
3
Pipe
in.
18 20 21 24 27 30 33 36 39 42
TABLE 2 Design External Lead*--Ib/Iineal ft
Classification
-
30
2 500 2 500 2 500 2 800 3 500 3 500 3 500 4000 4 200 4 300
35
3000 3 500 3 500 3 800 4 200 4 500 5 000 5000 5 300 5 TOO
40
4 000 4 500 4 500 5 000 5 500 6 000 6 500 7 000 7 500 8000
45
5 000 5 500 5 800 6 200 7 000 7 500 8 000 9000 9 700 10 500
50
6 500 7 100 7 300 8 100 8 800 9 700 10 500 11 200 12 000 13 000
60
8 500 9 500 9 700 11000 12 500 13 500 14 500 16 000 17 200 18 500
70
11000 12 000 12 500 15 000 16 500 18 000 19 500 21 000 22 500 24 000
80
14 000 15 000 16 000 19 000 20 500 22 500 24 500 26 000 28 000 30 000
90
18000 20 000 21 000 24 000 27 000 30 000 33 000 36 000 39 000 42 000
* It is necessary to apply a load factor to the above three-edge bearing loads in order to 'correlate them to the field loads. (See AWWA Standard C403.)
2.2.3 Crushing strength. Each length of pipe shall have sufficient strength to support the design external load indi cated for its classification in Table 2 when subjected to the crushing-test procedure specified in this standard. Sec. 2.3--Chemical Requirements
Pipe shall be designated as either Type I or Type II according to its
content of uncombined calcium hy droxide as determined by the test pro cedures in this standard for uncom bined calcium hydroxide. The require ments for each type are
Type I--no limit on uncombined cal
cium hydroxide
.J
Type II--1.0 per cent or {less un
combined calcium hydroxide; l
Section 3--Design
Sec. 3.1--Pipe Classifications
Pipe supplied under this standard shall be made in one or more of the classifications shown in Table 1. (The numerical value for each classification is equivalent to one tenth of the hy drostatic lot test pressure.)
Sec. 3.2--Pipe Diameters
Pipe shall be made with nominal in side diameters of 18, 20, 21, 24, 27, 30. 33. 36. 39. and 42 in. The average inside diameter of a standard or ran dom pipe length shall not be less than the nominal diameter by more than 1.5 per cent.
CAPCO JEN 0019877
4 A-C TRANSMISSION PIPE--18 IN. THROUGH 42 IN.
Sec. 3.3--Pipe Lengths
Pipe shall be produced in standard, random, and short lengths. At lea^. 90 per cent of the total footage of pipe of any classification, type, and size, excluding short lengths, shall be fur nished in standard lengths. The re maining 10 per cent may be in random lengths.
3.3.1 Standard length shall be 13 ft = 1 in.
3.3.2 Random lengths shall be cut from standard lengths and shall be not less than 7 ft long.
3.3.3 Short lengths for making con nections to valves, fittings, or struc tures, and for making closures shall be furnished as specified by the pur chaser.
Sec. 3.4--Couplings
A coupling shall consist of an as bestos-cement sleeve of the same type and classification as the pipe and two rubber rings or a device that has equal or better bonding characteristics, strength, and serviceability as that of an asbestos-cement coupling. The man ufacturer shall submit to the purchaser for approval, prior to manufacturing, specifications and drawings of alternate couplings.
TABLE 3 Wall Thickness Tolerances
Size of Pipe in.
18 20-24 27-30 33-36 39-42
Wall Thickness'Tolerance
in.
-0.12 -0.14 -0.17 -0.20 -0,23
3.4.1 One coupling of the same size and classification as the pipe shall be furnished with each standard and ran dom length of pipe.
3.4.2 Rubber rings shall 'conform to the requirements of the latest edition of ASTM D1869, "Rubber Rings for As bestos-Cement Pipe."
Sec. 3.5--Joints
Joints shall be capable of withstand
ing, without leakage, a hydrostatic
pressure test as defined in Section
S.2.2.1.
>]
Sec. 3.6--Wall Thickness j
The wall thickness of the mafchined portion of any length of pipe shall not be less than the manufacturer's stan dard by the listed tolerance in Table 3.
Section 4--Workmanship and Finish
Sec. 4.1--Imperfections
4.1.1 Interior surfaces. The inside surface of each length of pipe shall be free from bulges, dents, and tears that result in a variation in diameter of more than 0.20 in. from the diameter of adjacent unaffected portions of the surface.
4.1.2 Coupling areas. The coupling areas of the barrel of each length of pipe shall be free from dents and gouges that could cause leakage from
the joint. 4.1.3 Exterior surfaces. Flaking on
the exterior surface and edge of ma chined ends shall not extend back by
CAPCO JEN 0019878
SECTION 5--INSPECTION, TESTING, AND REJECTION
S
more than 0.500 in. from the end, have a depth of more than 0.125 in., and shall not extend around the perimeter for more than 0.500 in. at any one location.
4.1.4 Straightness. Each length of pipe shall not vary in straightness by
more than 0.05 in./ft of length when the variation is measured as follows:
Measure the maximum ordinate from the exterior surface of the pipe by placing a straightedge that exceeds the pipe length against the exterior surface and measure the maximum distance from the exterior pipe surface to the straightedge.
Section 5--Inspection, Testing, and Rejection
Sec. 5.1--Inspection
5.1.1 General. Inspection by the pur chaser shall not relieve the manufac turer of the responsibility to furnish material conforming in all respects to the requirements of this standard.
5.1.2 Notification. If inspection is specified under Sec. 5.1.4 by the pur chaser, the manufacturer shall notify the purchaser, in advance, of the date, time, and place of testing of the pipe, so that the purchaser may be repre sented at the test.
5.1.3 Access. The inspector shall have free access to those parts of the manufacturer's plant that are involved in work performed under this standard. The manufacturer shall afford the in spector, without charge, all reasonable facilities for determining whether the pipe meets the requirements of this standard.
5.1.4 Testing. If inspection is speci fied by the purchaser, the purchaser at
his option may witness any or all test phases. The pipe to be tested will have passed the routine inspection .aid test ing of this specification. The number of tests to be conducted for hydrostatic bursting strength (lot test) an&, when required, crushing strength shall be limited to one per each 300 standard lengths of each size, type, and classifi cation of pipe on the order. If uncom bined calcium hydroxide tests are re quired, the number of tests will be one for each size, type, and classification of pipe on the order. The purchaser or his authorized inspector may select the pipe to be tested. Retesting and re jection as shown in Sec. 5.3 shall apply.
Sec. 5.2--Physical Test Requirements
5.2.1 Test specimens. All pipes and couplings tested under this standard shall be in a normal, air-dried condi tion when tested.
CAPCO JEN 0019879
A-C TRANSMISSION PIPE--18 IN. THROUGH 42 IN.
TABLE 4 Hydrostatic Tests
pp
Classification
Proof Test
psi
Lot Test
psi
30 225 300
35 263 350
40 300 400
45 338 450
50 375 500
60 450 600
70 525 700
80 600 800
90
675 900
Tig. 1. Crushing Test Assembly
The diagram at the left shows a side
view of the test assembly; that at the
5.2.2 Hydrostatic tests: 5.2.2.1 Each standard, random, or short length of pipe and each coupling
right, an end view. P represents load; R, approximately OS in.--the radius of the bearings; D, the nominal diameter of the pipe; and C, the clear space between
sleeve shall be tested under an internal supports. C should be approximately
hydrostatic pressure as shown for the 1 in./ft of internal pipe diameter, but in
routine proof test in Table 4. All air
no case less than 1 in.
shall be expelled and the water pres
sure shall be increased to the test pres
sure at a uniform rate of not less than 5.2.4 Crushing tests. On lots >n-
100 psi/s. The test pressure shall be taining more than 100 lengths of ..etch
maintained for at least 5 s. Any pipe size and classification, one length ftbm
length or coupling sleeve that shows each 300 lengths or fraction thereof
leakage, sweating, or other defects shall shall be tested for crushing strength.
be rejected.
If inspection by the purchaser has been
5.2.2.2 From each lot that has specified, the length of pipe to be tested
passed the hydrostatic proof test, a 1-ft, may be selected by the inspector. From
or longer length of pipe shall be cut each selected length, one unmachined
from the unmachined portion of a pipe. length of pipe 1 ft long shall be cut.
The unmachined sample shall with This section shall be tested by the
stand the hydrostatic lot test shown in crushing-test method shown in Fig. 1.
Table 4 when tested in the manner After 75 per cent of the specified load
specified in paragraph 5.2.2.1 except has been reached, the loading shall be
that the test pressure need not be held applied at a uniform rate of approxi
for 5 s. If inspection by the purchaser mately 2 000 lb/min. The test section
has been specified, the length of pipe shall not fail until the total load applied
to be tested may be selected by the in meets or exceeds the applicable value
spector. Each length of pipe so tested shown in Table 2.
shall be retested in the manner and at 5.2.4.I For this test, the two lower
the pressure specified in paragraph ' bearings shall consist of two straight
5.2.2.I.
strips with vertical sides, each strip
5.2.3 Flexural testing. No flexural having its interior top edge rounded to
testing is required.
a radius of approximately 0.5 in. The
rtAPfiO .JFN noiqsso
SECTION 5--INSPECTION, TESTING, AND REJECTION
7
strips shall be of hardwood or metal; if Sec. 5.3--Retests (Physical) metal, a piece of leather belting 3/16 in. and Rejection
in thickness shall be laid over them. The strips shall be securely fastened to a rigid block, with the interior vertical faces parallel and a distance apart of approximately 1 in./ft of internal pipe diameter, but in no case less than 1 in. The upper bearing shall be a rigid wooden block, straight and true from end to end. The upper and lower bearings shall extend the full length of the test section.
5.2A.2 For those sizes and classifi cations where the specified crushing load exceeds 30 000 lb/linear ft, the test length may be less than 1 ft long. In those cases, the test load shall be such as to produce an equivalent speci fied loading per linear foot.
5.2.5Machines for testing. 5.2.5.1 The machines used for the
5.3.1 Crushing strength. The fail ure of any specimen tested'for crush ing strength to support 75 per cent of the crushing load required in Ta ble 2 shall be cause for rejection of the entire lot of that size and classifi cation manufactured during the same shift as the test specimen. If any spec imen tested for crushing strength sup ports more than 75 per cent but less than 100 per cent of the crushing load, two additional pipe sections - of the same size and classification, manufac tured during the same shift, shall be subjected to the crushing test. The additional lengths may be selected by the inspector, if inspection by the pur chaser has been specified. The failure of one of these additional specimens to meet the full crushing strength require
hydrostatic proof test shall have gas ment shall be cause for rejection of the
kets that seal the ends of the pipe, couplings, or pipe and coupling with factory-assembled joint, but exert no end pressure. Couplings also may be hydrostatically proof tested with a rub ber bladder inside of the coupling and, if so tested, each coupling shall have sufficient strength to withstand a test pressure of ten times the classification of the coupling. The machine used for
entire lot of that size and classification
manufactured during the same.shift as
the test specimen.
1
5.3.2 Hydrostatic tests. If'aliy pipe
subjected to the hydrostatic te4s spec ified in Sec. S.2.2.2 fails to withstand
the pressure specified in Table 4, two additional lengths of the same size and classification, manufactured during the
same shift, shall be subjected to the
same hydrostatic test. The additional
hydrostatic burst testing or lot test lengths may be selected by the inspec
shall have gaskets that seal against the tor, if inspection by the purchaser has
inside of the pipe at or near the ends been specified. The failure of one of
of the test specimen without materially counteracting the hydrostatic test pres sure.
5.2.5.2 The machine used for the crushing test shall be substantial and
these additional lengths to withstand the specified pressure shall be cause for rejection of the entire lot of that size and classification manufactured during the same shift as the test lengths.
rigid throughout so that the distribu Sec. 5.4--Test for Uncombined tion of the load will not be appreciably Calcium Hydroxide
affected by the deformation or yielding The manufacturer shall perform this
of any part of the machine.
test as often as necessary to ensure
CAPCO JEN 0019881
8 A-C TRANSMISSION PIPE--18 IN. THROUGH 42 IN.
compliance with the requirements for uncombined calcium hydroxide in Type II pipe.
5.4.1 Reagents. Phenolphthalein indicator. Dissolve 1.0 g of phenolphthalein in 100.0 ml of absolute ethanol.* Glycerol-ethanol solvent. Prepare a solution consisting of glycerol and an hydrous or absolute ethanol,* 1:2 by volume. To each litre of this solution, add 2.0 ml phenolphthalein indicator. Adjust the solvent to slightly basic with either dilute NaOH in absolute ethanol* or standard ammonium ac etate, depending upon the original pH. Strontium nitrate [Sr(N03)2]. Standard ammonium acetate solu tion. Dissolve 16.0 g dry crystalline ammonium acetate in 1 1 of absolute, or anhydrous, ethanol.* Standardize the ammonium acetate solution by titrating against pure CaO that has been freshly prepared by cal cining pure calcium carbonate or cal cium oxalate to constant weight in a platinum crucible at 1650-1830F (9001000C). When the calcined CaO has cooled in a desiccator, perform the following op erations in rapid succession. Grind it in an agate mortar. Then weigh out 0.05-0.06 g CaO into a clean, dry 250ml Erlenmeyer flask and add 60 ml of the glycerol-ethanol solvent and 2.0 g of anhydrous strontium nitrate to the flask. Place a TFE encapsulated mag netic stirring bar into the flask and attach a reflux condenser. Adjust the heating rate and stirring speed to ob tain a vigorous boiling and complete agitation. Titrate the hot solution with
* Specially denatured alcohol No. 30, 3a, or 2b, of the US Bureau of Internal Rev enue, or alcohol consisting of 95 per cent specially denatured alcohol No. 3a plus 5 per cent isopropanol, may be substituted.
standardized ammonium acetate solu tion every 5 min. The endpoint is reached when no further color, appears in the solution after 10 min of boiling. Titration is to be carried out only on a hot solution. Good titration proce dure is evidenced by a change to pink color upon cooling.
5.4.2 Procedure. Step 1. Brush representative pieces of the pipe free of dust and drill with a clean, sharp 0.25-in. carbide-tipped drill inward from the outer surface at a rate of penetration of approximately 1 ipm until the drill point emerges from the inside wall. Catch the drill ings on a clean sheet of glazed paper. Use a soft brush to collect all drillings. Screen through a 20-mesh screen im mediately, and place in a weighing bottle. Step 2. Place the bottle with top removed into a drying oven at 217F (105C) for 2 hr and then cool to room
temperature in a desiccator. : j Step 3. Weigh out 1 ~ 0.01Q g of
the dried sample to the nearest OfOOl g and place in a clean, dry 250-ml isrlen-
meyer flask, to which a TFE-encapsulated stirring bar, 60 ml of the glycerol-
ethanol solvent, and 2.0 g Sr(N03)2 have been added. Attach the flask to a water-cooled condenser (with a stan
dard 24/40 glass joint) and place on a hot plate with a magnetic stirrer. Boil the solution gently for 30 min,
stirring slowly. Then, remove the flask and filter the mixture, under vacuum, through a Buchner funnel. Bring the filtrate to a boil and titrate to a colorless endpoint with the stan
dardized ammonium acetate reagent. Determine the endpoint by comparing with a similar mixture containing no phenolphthalein indicator.
CAPCO JEN 0019882
SECTION 6--MARKING AND DELIVERY
9
5.4.3 Calculations:
Percentage uncombined Ca(OHi) ^ X100
,, lyCaO X 1.32
-------- va-----
where
E = the weight in grams of Ca(OH)2 per millilitre of standardized ammonium acetate solution
WCaO -- the weight in grams of CaO in the standardized ammonium acetate solution
Va = the volume in millilitres of standardized ammonium acetate used in titration of the solution.
where
V = the volume of- standardizeammonium acetate solution required by the sample, in millilitres
W = the weight of the sample in grams.
Sec. 5.5--Test Records
The results of all tests shall be re corded and retained for one year, and shall be available to the purchaser at the place of manufacture. .
%
Section 6--Marking and Delivery
Sec. 6.1--Marking
6.1.1 Standard and random lengths. Each standard or random length of pipe shall be clearly marked on the outside surface with the trade name, nominal inside diameter, classification, type, date, and shift of manufacture, and the word "Transmission."
6.1.2 Short lengths. Each short length of pipe shall be clearly marked on the outside surface with the nom inal inside diameter, the classification, the letter T to indicate that it has been hydrostatically tested, and the word "Transmission."
6.1.3 Couplings. All component parts of each coupling shall be clearly
marked for use with the pipe for which they are intended. Each coupling shall also be marked with the letter T to indicate that it has been hydrostatically tested.
6.1.4 Special markings. If factory inspection is made by the purchaser or his authorized inspector, each pipe and each coupling shall receive an addi tional special marking of no more than three letters, as specified by the pur chaser.
Sec. 6.2--Preparation for Shipment
All pipe and couplings, unless other wise specified, shall be prepared for standard commercial shipment.