hopper, feeder, crusher, bucket etevoior end belt conveyor unloaded and raised coal to the bunkers. In the new plant, complete new handling equipment is not being installed now. The existing hopper, crusher and elevator ire used, and an additional cross-conveyor and belt conveyor Installed to deliver coal to the new bunkers. Over the bunkers the conveyor b equipped with a selfpropelled tripper. When additional boilers ore Installed, a new hopper, crusher and elevator can be added to this coal-handling equipment and placed at the opposite end of the building. The old equip ment will then be abandoned and the belt-conveyor drive changed to permit feeding it from the new elevator. Bunkers of about 30-hr storage ca pacity are built with- hopper bottoms ond flat reinforced-concrete sides. Con struction is somewhat more expensive than a suspended design, but it elimi nates dead pocket*. This advantage to important with high sulphur-content coal, which is apt to catch hre from spontaneous combustion if left in stor age very long. From the bunker open ings, eosl discharges through auto matic scales to the pulveriser feeders on the operating floor. Ash Hoadlleg. Ashes, from furnace bottoms, boiler's last-pass hopper, ond from dust-collector storage bins, are handled by a pneumatic conveyor sys tem, discharging to a 100-ton tile stor age tank. A steam ejector produces the vacuum. A mechanical blower was considered but the higher initial expense and maintenance costs would more than offset its lower operating cost. Pushbutton stations, conveniently near the ash intakes, control a valve in the exhauster steam line of the con veyor system. Its operation Is simple, clean and convenient Food Pomps. Two high-pressure feed pumps, one turbine- and one motordriven, have sufficient eapaeity each to supply both boilers. The turbinedriven unit normally operates when available on 170-psl steam and exhausts at 25 psi. The motor-driven pump op erates to start the plant or when the turbine-driven unit is out (or repairs. Two low-pressure feed pumps in the new plant both motor-driven, supply water to the old boilers. During lowpressure operation of the new boilers, the turbine-driven high-pressure pump was also used, operated at reduced speed. All feed pumps are in the base ment directly under the deaerator. A story of the feedwater-treating system will be published In an early Issue. 3ASH-HAN0UNG SYSTEM. Ashm from the fumoco bottoms, the boiler's loitpou hoppers ond from the dust-collector itorooe bins ore handled by a pneumotlc conveyor system, which discharge* to a 100*ton storoQO tonk mode of tile Turbins Generetor. Built in Switzer land, the turbine-generator is an im pulse-reaction backpressure unit, rated at 3500 kw at 600-psi 700-F Inlet-steam conditions and 170-psi exhaust. Power is generated at 6600 v, 3-phase, 60 cycles. . The governing system Is interesting. A pump geared to the turbine shaft end equipped with a spring-loaded re lief valve supplies control and lubricat ing oil at constant pressure. A-pressure connection, from the pump discharge through an adjustable orifice, goes to individual piston operators on the steam-inlet valves. A bleed valve, op erated directly by the governor weights, controls pressure in this line. A drop in speed closes this bleed valve, thereby allowing pressure et the inlet valves to build up and open them. These doubleseated, balanced valves are spring- loaded so they open in sequence as oil pressure rises. The entire system is simple ond free of mechanical linkages. The turbine shaft is sealed where it passes through the casing with laby rinth glands, through which an appre ciable quantity of steam is permitted to pass. This steam is piped to a small surface condenser in the treated-water line where most of the heat b re covered. TTie generator has a closed air-cooling system in which raw water is used in the air cooler. Meters and Controls. As the di agram on p 67 shows, a fairly complete system of steam-flow meters was in stalled. Consideration was given, to this in making the piping layouts to provide suitable ori6ce locations. The boilers have automatic control. As mentioned, the old plant Included a steam accumulator, connected be- M I3901 POWER July 1940 tween the 170- and 25-psi mains. By absorbing temporary surpluses of 170psi steam and moking up deficiencies la the supply of 2S-psi steam, the ac cumulator served to iron out fluctua tions in the total process demand. This permitted operating the old stoker-fired boilers at fairly constant load, an im portant (actor in their performance, hut less so with the new installation. But the accumulator was useful enough to warrant continuing it in service, whieh required a alight departure from nortQal operation. With the accumulator in service the boilers can operate at constant load. It Is necessary, however, to eel the load fnanuaily by adjustment of the master elector valve. Pressure in the 600-psi header U then controlled by the 600Ond 170-psl reducing valves, which op- *rate from a pressure controller con- nected to their inlet side. Pressure in the 170-psi system is under control of the accumulator, which automatic ally accepts steam from the 170-psi line or delivers it to the 25-psi line to maiatain constant pressure. When the accumulator is out of serv ice provision U made for conventional operation--that is, with the 600-psi pressure controlled from a master pres sure controller operating on the boiler firing rate. Reducing valves then con trol the 170-psi pressure through o pressure controller connected to their outlet side- Electrical equipment. All motors of 1-hp reting and over are operated on 550-v &phase current, amoller motors on 220-v 3-phase. Ail 550-v motor starters,: except for the high-pressure feed pump, are combination fusible type, located in a single room. Besides providing convenient maintenance, com bination magnetic contactors with fused disconnect switches proved economical since they serve to limit short-circuit currents to values that fuses eon handle safely. The starters are divided between two buses, each supplied by two feeders from the main bus. A fifth feeder sup plies the motor on the bigh-presiure feed pump. Motors for Induced-draft Ians, forced-draft fans, pulverizers and eosl feeders are interlocked so they must start in the order named. Failure of one motor automatically stops those succeeding it in the sequence given. Auxiliary equipment is divided be tween the two buses so o fault on one bus will not cause a complete plant shutdown. An oil circuit breaker of 250,000- pOW|R j,,|y m8 f3911 hi