Document 10aK67yjDjJoJd11mZ4G5g1mK

Heating Systems Boilers, Cast-Iron R A D I AT Member DEC. U. S. HIT. OFF. R C O R P ORATION II GENERAL OFFICE, DETROIT 31, MICH. BRANCHES AND SALES OFFICES IN PRINCIPAL CITIES US-CAPITOL* THINTUBE RADIATORS 3-Tube ' Heights Per Section In. Heating Surface 25 1.6SqFt 4 Tube ' 22 1.8 Sq Ft 25 2.0 Sq Ft 5-Tube 12 2.1 SqFt 25 2.4 Sq Ft 6-Tube 19 2.3 Sq Ft 25 3.0 Sq Ft 32 3.7 Sq Ft *\% in. Centers. US-SUNRAY RADIATORS 19 in. heigiht is standard, 21 in. and 22^ in- heights can be furnished by use of higher legs. No. 5--Depth 5% in. Hejfflilt Per Section In. Heating Surface 19 1.8 Sq Ft No. 6--Depth in. Heights Per Section In. Heating Surface 19 1.8 Sq Ft Boiler No. A.GJL Rating Sq Ft Water A.OA. Output Btu Per Hour Direct C. 1. Radiator Load Sq Ft 150 Btu Per Sq Ft Emission Direct C. I. Radiator Load Sq Ft of Water Accelerated (200 Btu Per Sq Ft Emission) Input Btu Per Hour Water Inlets No. and Size Water Flue Outlets Outlets No. and No. and Size Size Minimum Chimney Size Size of Main Gas Valve 3-11 240 36.000 4-11 360 54.000 5-11 480 72.000 6-11 600 90.000 7-1! 720 108.000 8-11 840 126.000 155 230 310 385 470 550 115 45.000 2-2>/2` 2*2'// 1-4' 4' 175 67.500 2-2'// 2-2*// I-5* 5' 230 2-2VZ 2-2'// 1-5' 5' 290 112*500 2-21/1- 2-2'// 6' 350 135.000 2-21/1- 2-21// 1-7' 7' 410 157.500 2-21// 2-2W 1-7' 7' -The Amount Allowed for Piping and Pickup Capacity for Each Boiler is Based on I-B-R Selection Factors. i Va' pa* PA* 1' 1' 1' US-22 "COMFORT LINE" GAS BOILER Data below US-11 "COMFORT LINE" GAS BOILER Data above A.CA. A.C.A. Boiler Rating Rating No. SqFt SqFt Steam Water A.C.A. Output Btu Per Hr Direct C.l. Radiator Load Sq Ft Steam Sq Ft Water Sq Ft of Water Accele rated Input Btu Per Hr Steam or Water Inlets No. and Size Steam or Water Outlets No. and Size Flue Outlets No. and Size Inches Water 1 jne Inches Hue Size to Chim ney Inches Size of Main Gas Valve Inches 7-22 9-22 11-22 13*22 15-22 17-22 19-22 21-22 23-22 25-22 27-22 800 1120 1440 1760 2080 2400 2720 3040 3360 3680 4000 1280 1790 2300 2820 3330 3840 4350 4860 5370 5890 6400 192.000 268.800 345.600 422.400 499.200 576.000 652.800 729,600 806.400 '883.200 960.000 530 750 980 1210 1450 1690 1935 2170 2425 2675 2930 850 1200 1570 1940 2320 2710 3100 3470 3880 4280 4690 635 900 1175 1450 1740 2030 2320 2600 2910 3210 3520 240.000 336.000 432.000 528.000 624.000 720.000 816.000 912.000 1.008,000 1.104,000 1.200.000 2-3* 2-3' 2-3' 2-3' 2-3' 2-3* 2-3' 2-3' 2-3' 22--3y* 2-4' 2-4' 2-4' 2-4' 2-4' 2-4' 2-4' 2-4' 2-4* 2-4' 2-4' 1-9* 2-7' 2-8' 2-9* 2-10* 3_9* 3-9* . 3-10" 4-10* 4-10* 4-10* 34' 34' 34' 34' 34' 34' 34' 34' 34* 34' 34' 9" i y.' 10* i1/,' 12' '/}" 13' 15' 1w" 16* 2" 16' 2" 18' 2" 20" I'/i 20" ll/i 20" i/2 Based on I. B - R Piping and Pickup Allowances; Emission Btu per Sq Ft Steam 240, Water ISO, Water Accelerated 200. 1156 Healing Systems Boilerst Cast-Iron GENERAL OFFICE, DETROIT 31, MICH. BRANCHES AND SALES OFFICES IN PRINCIPAL CITIES US-2 j~;.CAPITOL SUNRAY OIL FIRED BOILERjf. '<e, Boiler No. 2413 24)4 24)5 24)6 Net Sq Ft Direct Cast Iron Radiation Steam Water 350 560 500 800 650 1040 800 1280 Net Btu Per Hr. 84,000 120,000 156.000 192.000 Gross Output Btu Per Hr. 129.000 182.000 234,000 285.000 US-3 "THRIFT MODEL" SUNRAY BOILER Boiler Number Sq Ft Direct Cast Iron Radiation Hand Fired Stoker Fired Oil Fired Steam Water Steam Water Steam Water R43-S or W 300 480 400 640 400 640 R53-S or W 450 720 550 880 550 880 R63-S or W 600 960 700 1120 700 1120 RED TOP CAPITOL BOILERS "A" Series--All Fuels Boiler No. A-7 A-8 . A-9 A-10 A-tl Sq Ft Direct Cast Iron Radiation Steam 340 440 540 640 740 Water 545 705 865 1025 1185 "B" Series--All Fuels B-7 B-8 B-9 B-10 B-11 B-12 B-13 B-14 740 920 1110 1275 1440 1580 1730 1880 1180 1470 1770 2040 2300 2530 2770 3000 "C" Series--All Fuels Boiler No. C-12 C-14 C-16 C-18 C-20 C-22 C-24 C-26 C-28 C-30 Sq Ft Direct Cast Iron Radiator Steam 2250 2715 3180 3645 4110 4575 5040 5450 5800 6110 Water 3600 4345 5090 5830 6575 7320 8065 8720 9280 9775 US-25 OIL FIRED BOILER "DEEPFIRE" HOT WATER SUPPLY BOILERS COAL OR OIL '100 lb Working Pressure Boiler No. US-25-3 US-25-4 US-25-5 US-25-6 US-25-7 Net Sq Ft Direct Cast Iron Radiation Steam 545 905 1265 1625 1985 Water 875 1450 2025 2600 3175 Net Btu Per Hr. 131.000 217,000 304.000 390.000 476.000 Gross Output Per Hr. 197.000 320.000 439.000 555.000 669.000 Capacity--Gallons 100 rise in I Hour Coal Fired Oil Fired Boiler No. 30 40 50 60 Gallons 132 252 360 450 Boiler No. 030 040 050 060 Gallons 115 165 215 265 1157