Document 10aK67yjDjJoJd11mZ4G5g1mK
Heating Systems Boilers, Cast-Iron
R A D I AT
Member DEC. U. S. HIT. OFF.
R C O R P ORATION
II GENERAL OFFICE, DETROIT 31, MICH. BRANCHES AND SALES OFFICES IN PRINCIPAL CITIES
US-CAPITOL*
THINTUBE RADIATORS
3-Tube
' Heights Per Section In. Heating Surface
25 1.6SqFt
4 Tube ' 22 1.8 Sq Ft 25 2.0 Sq Ft
5-Tube 12 2.1 SqFt 25 2.4 Sq Ft
6-Tube 19 2.3 Sq Ft 25 3.0 Sq Ft 32 3.7 Sq Ft
*\% in. Centers.
US-SUNRAY RADIATORS
19 in. heigiht is standard, 21 in. and 22^ in- heights can be furnished by use of higher legs.
No. 5--Depth 5% in.
Hejfflilt Per Section In. Heating Surface
19 1.8 Sq Ft
No. 6--Depth
in.
Heights Per Section In. Heating Surface
19 1.8 Sq Ft
Boiler No.
A.GJL Rating
Sq Ft Water
A.OA. Output
Btu Per Hour
Direct C. 1. Radiator Load
Sq Ft 150 Btu Per
Sq Ft Emission
Direct C. I. Radiator Load Sq Ft of Water
Accelerated (200 Btu Per Sq Ft Emission)
Input Btu Per Hour
Water Inlets No. and Size
Water Flue Outlets Outlets
No. and No. and Size Size
Minimum
Chimney Size
Size of Main
Gas Valve
3-11 240
36.000
4-11 360
54.000
5-11 480
72.000
6-11 600
90.000
7-1! 720 108.000
8-11 840 126.000
155 230 310 385 470 550
115
45.000 2-2>/2` 2*2'// 1-4'
4'
175
67.500 2-2'// 2-2*// I-5*
5'
230
2-2VZ 2-2'// 1-5'
5'
290 112*500 2-21/1- 2-2'//
6'
350
135.000 2-21/1- 2-21// 1-7'
7'
410
157.500 2-21// 2-2W 1-7'
7'
-The Amount Allowed for Piping and Pickup Capacity for Each Boiler is Based on I-B-R Selection Factors.
i Va'
pa* PA*
1' 1' 1'
US-22 "COMFORT
LINE"
GAS BOILER
Data below
US-11 "COMFORT
LINE"
GAS BOILER
Data above
A.CA. A.C.A. Boiler Rating Rating
No. SqFt SqFt Steam Water
A.C.A. Output
Btu Per Hr
Direct C.l. Radiator Load
Sq Ft Steam
Sq Ft Water
Sq Ft of Water Accele rated
Input Btu Per Hr
Steam or
Water Inlets No. and Size
Steam or
Water Outlets No. and
Size
Flue Outlets No. and
Size Inches
Water 1 jne
Inches
Hue Size to Chim
ney Inches
Size of
Main Gas
Valve Inches
7-22 9-22 11-22 13*22 15-22 17-22 19-22 21-22 23-22 25-22 27-22
800 1120 1440 1760 2080
2400 2720 3040 3360 3680 4000
1280 1790 2300 2820 3330 3840 4350 4860 5370 5890 6400
192.000 268.800 345.600 422.400
499.200 576.000 652.800 729,600 806.400 '883.200 960.000
530 750 980 1210 1450 1690 1935 2170 2425 2675 2930
850 1200 1570 1940 2320 2710 3100 3470 3880 4280 4690
635 900 1175 1450 1740
2030 2320 2600 2910 3210 3520
240.000 336.000 432.000 528.000 624.000 720.000 816.000 912.000 1.008,000 1.104,000 1.200.000
2-3* 2-3' 2-3' 2-3' 2-3' 2-3* 2-3' 2-3' 2-3'
22--3y*
2-4'
2-4' 2-4' 2-4'
2-4' 2-4' 2-4' 2-4' 2-4*
2-4' 2-4'
1-9* 2-7' 2-8' 2-9* 2-10* 3_9*
3-9* . 3-10" 4-10* 4-10* 4-10*
34' 34' 34' 34' 34' 34' 34' 34' 34* 34'
34'
9" i y.'
10* i1/,'
12' '/}"
13' 15'
1w"
16* 2"
16' 2"
18' 2"
20" I'/i
20" ll/i
20" i/2
Based on I. B - R Piping and Pickup Allowances; Emission Btu per Sq Ft Steam 240, Water ISO, Water Accelerated 200.
1156
Healing Systems Boilerst Cast-Iron
GENERAL OFFICE, DETROIT 31, MICH. BRANCHES AND SALES OFFICES IN PRINCIPAL CITIES
US-2
j~;.CAPITOL SUNRAY
OIL FIRED BOILERjf.
'<e,
Boiler No.
2413 24)4 24)5 24)6
Net Sq Ft Direct Cast Iron Radiation
Steam Water
350 560 500 800 650 1040 800 1280
Net Btu Per Hr.
84,000 120,000 156.000 192.000
Gross Output
Btu Per Hr.
129.000 182.000 234,000 285.000
US-3 "THRIFT MODEL"
SUNRAY BOILER
Boiler Number
Sq Ft Direct Cast Iron Radiation Hand Fired Stoker Fired Oil Fired Steam Water Steam Water Steam Water
R43-S or W 300 480 400 640 400 640
R53-S or W 450 720 550 880 550 880 R63-S or W 600 960 700 1120 700 1120
RED TOP CAPITOL BOILERS
"A" Series--All Fuels
Boiler No.
A-7 A-8 . A-9 A-10 A-tl
Sq Ft Direct Cast Iron Radiation
Steam
340 440 540 640 740
Water
545 705 865 1025 1185
"B" Series--All Fuels
B-7 B-8 B-9
B-10 B-11 B-12 B-13
B-14
740 920 1110 1275
1440 1580 1730 1880
1180 1470 1770 2040
2300 2530 2770 3000
"C" Series--All Fuels
Boiler No.
C-12 C-14 C-16 C-18 C-20 C-22 C-24 C-26 C-28 C-30
Sq Ft Direct Cast Iron Radiator
Steam
2250 2715 3180 3645 4110 4575 5040 5450 5800 6110
Water
3600 4345 5090 5830 6575 7320 8065 8720 9280 9775
US-25
OIL FIRED BOILER
"DEEPFIRE"
HOT WATER SUPPLY BOILERS
COAL OR OIL '100 lb Working Pressure
Boiler No.
US-25-3 US-25-4 US-25-5 US-25-6 US-25-7
Net Sq Ft Direct Cast Iron
Radiation
Steam
545 905 1265 1625 1985
Water
875 1450 2025 2600 3175
Net Btu Per Hr.
131.000 217,000 304.000 390.000 476.000
Gross Output Per Hr.
197.000 320.000 439.000 555.000 669.000
Capacity--Gallons 100 rise in I Hour
Coal Fired
Oil Fired
Boiler No.
30 40 50 60
Gallons
132 252 360 450
Boiler No.
030 040 050 060
Gallons
115 165 215 265
1157