Document 10KJ7m6XNJR1jyJz3mL84nLYo
PLAINTIFF'S EXHIBIT
FK-126
CSI DIV
6 AIQ ISO
gypsum wallboard
products systems . ..
... are among the most versatile building materials on the market today, being used for construction of numerous types of walls, partitions and ceilings. Gypsum Boards consist of a gypsum core sandwiched between specially selected outer papers, giving them strength well in excess of that required by ASTM and Federal Specifications. Their universal accept ance stems from a relatively low cost, and excellent performance in providing fire pro tection for both wood and steel construction, and in preventing the transmission of unwanted sound through walls and ceilings. FLINTKOTE Gypsum Wallboards may be used in certain exterior locations, when special recom mendations are followed.
The "selector chart1' and descriptions to the right will, provide you with a quick picture of the range, types and characteristics of FLINTKOTE'S family of Gypsum Board Products.
Fire Resistance -- All FLINTKOTE Gypsum Wallboard Products are highly resistant to fire. FLINTKOTE Super FIRE-HALT Gypsum Wallboard Products are recom mended where one hour or greater fire resistance is required. See tabulation of basic data on pages 10 and 11 for construction fire ratings.
Insulation -- FLINTKOTE Insulating (Foil-Back) Gyp sum Wallboard with aluminum foil backing effectively helps to keep warm air indoors during the winter and hot air outdoors in the summer. It serves as an excel lent vapor barrier by preventing condensation from developing in the stud spaces of walls.
Decoration -- FLINTKOTE Gypsum Wallboard is an ex cellent base for decorative paints, wallpapers, texture finishes, fabrics and vinyl wall coverings. Attractive FLINTKOTE Vinyl-Covered and Wood Grain Gypsum Wallboards are available to meet the broad demands of the buying public to complement their decorating schemes for new construction and remodeling.
Application and Finishing -- Recommended application and finishing of FLINTKOTE Gypsum Wallboard Prod ucts are in. accordance with ANSI A97.1 and specifica tions of.The Flintkote Company.
Limitations -- FLINTKOTE Gypsum Wallboard Products are not recommended in locations exposed directly to water.
This catajog contains information for comparison and selection, as well as details and specifications. It can not, does not, answer your every question. It has been organized with you the user in mind.
If you need- answers, or additional information on the contents, we suggest you contact one of- the offices located-near you (see back cover for phone numbers), or contact the home office.
selector chart
--' 1
description
FLINTKOTE Gypsum Wallboard -- Plant fabricated large, light- . 1
weight panels serve many needs. Tapered edges permit
smooth joint treatment and concealment.'SMOOTH JOINT. ;
(SJ) wallboards have a tapered/beveled edge vto minimjze ridging and beading along the edges of board finished with .;' j
tape and joint compound.
; v"\X `
FLINTKOTE Insulating (Foil-Back) Gypsum Wallboard -- Af-
fords an insulation ("C") factor of 0.25 to 0.30.when used
with an air space for inside walls and a perm rating of less
than 0.3. (FHA requires foil-side to studs and minimum
air space.)
'
j
1
FLINTKOTE Gypsum Backing Board-- Especially designed '
for use in two-ply construction .(Double Wall) or as a base
for acoustical tile. Gray face paper permits easy lamination ,
of gypsum face panels to backing'board with' FLINTKOTE
if;1 ". . Laminating Compound.:,
..
FLINTKOTE Gypsum Sound Deadening Board -- Used as an
underlayment for V2" and
gypsumTwallboards for .good -
fire resistance and excellent- redtictiofi'irTsourid transmission.;
V4" thick,iv wide. ' !
' , :
FLINTKOTE Insulating (Foil-Back) :;Bac(ng Board -- Alumi-: . mum foil'is applied-,ti^ba^k:?c(fllrellfdlafr-^^um4)acking,boar(l^| , and;provides'an!effdctive vaporibarrierfancT excellent' insulat- .Ls*
. .in;g,(qua!|tie's-.\?;':;^j;--'
'TpNTKO.TE,;wpbd TGralnSGypsum'IWallbpard^-fl&vaila'ble ?in"Li'
several' rich` -top^;%!n3^il&'ti^^^^^^jn!;-'^aftenis `to en-f
hance decor or cdidr,fscheme:;0^any`room.
1 ' -.
f
i j. ^
FLINTKOTE Vinyl-Covered (Gypsum /WaUboard^ Decorative
viaI i boa rd' is distinguished: by its'rp.ure :,vi ny|]fa brie s urface and,,, 4*
.co'iiies.in a vast assofth^ent-of at&f^i^^flij'-^`nd-'|Bxtures.>.;!?!^l
. All aYe cqnipletejy washable.'^r^tfe^^Wtn-^jIa^ticjzersi^pig;
;.;rnen^-ahd'st^l}i7iz^re't6f,'l6ni'--iilfe.;Scuffrrelifita1it't^rl9<Von>,4$
chip or peel.
`f" "'r............... * '
FLINTKOTE STA-DRITM Gypsum }Wa|lboard -- Manu'factui;ed;ga
with a specially 'treated'^ate^rffn'o.i^tu^.'.resistanf^^^^^
core and green
backing for ce'ramV;1i^tail-and,-plasti^ir#^'i'tdcp,@g^tjt^^3
panels. Super Fi^E-HALT* STA-'BRr'<"ypil5nr5^i^i^^|l^^
or %!') is available for assemblies requinrigvadfed;WireSpilp-i:jS
tection. 1 . '*** -
''
G FLINTKOTE Super FIRE-HALT' Gypsum Walli^a^^eom^;t^
bines the advantages of xegular gypsum iwallbqardiwlth'extra ; : fire resistant characteristics. A specially -formuiabeli^Qre^l'f^; fords increased fire resistan`ce;ratings%6m":;l<hpur:tb''4,-hours when used in,recommended systems. . "S1-.-
FLINTKOTE Fire .Block Gypsum. Board -- Designed for use .over roof . rafters beneath fsheathibg/ipives feitt^iien[t|r^.isjt;^Lv,';
ance to.fire fromVwithput: QfTj^i^l^B^luef|?oSath^WPv.j?;.il sheathing and combustible'roof ;coverirfg^^^^^^^^^
FLINTKOTE GypsumiCdreboard ^-,Usea':asTthe'j,lb^^a^'&;
in solid, double .and triple sqjid .partitjOns. ^daitjOnal^layere,;;
of gypsum wallboard are ho'rmallydarhihated'ito coreboard to
complete assembly.
-:
FLINTKOTE FIRE-HALT; qypsum"..^h^ithing*Spgciaiiy
treated core and face;paper combine to'afford excellentwater
resistance. Large panels are applied .easily and
exterior sheathing. -'
. c/j.G? - ;
PRODUCT
Gypsum Wallboard
ASTM COMPLIANCE TYPE
FEOERAL COMPLIANCE SPECIFICATION SS-L-30C
GRADE cuss FORM
STYLE
THICKNESS
WIDTH
(D
LENGTH
(2)
EDGE
FINISH
C 36
III R
1
a
3
Vi", %" Vi", Ye"
4'
6'-16'
(4) Tapered
Manila Paper
Insulating (Foil-Back) Gypsum Wallboard (3)
C 36 III R
1
c
3 Ye", Vi", Ye" 4'
6'-16'
(4) Tapered
Manila Paper
Gypsum Backing Board
Ye", Vi", Ye" 4'
6'-12'
Square
(3)
C 442
IV
R
1
a1
Vi", Va"
2'
8'
Tongue & Groove
Gray Paper
Gypsum Sound Deadening Board
C 442 IV R 1 a 1
Vi" 4' 8' Square Gray Paper
1 Ye", Vi", %" 4'
6'-12' Square
Insulating (Foil-Back)
Backing Board
(3)
C 442
IV
R
1
c
2
Vi", Ye"
2'
8'
Tongue & Groove
Gray Paper
^ Wood Grain ^ Gypsum Wallboard (3)
. Printed
C 36
III R
3
a
4
Ye", Vi"
4' 8'-10' Beveled Simulated
Wood Grain
Vinyl-Covered Gypsum Wallboard
(3)
C 36
III R
3
a
4
!
Vi", Ye" 4'
8'-10' Beveled Vinyl-Covered
!
STA-DRI Gypsum Wallboard
(3)
C 630
II
W2
a
3
Vi", Ye"
Green Water 4' 8'-10'-12' Tapered Resistant
Paper
I Super FIRE-HALT ; Gypsum Wallboard
i
C 36 (Type X)
III
X
1
a
3
Vi", Ye"
4'
6'-16'
(4) Tapered
Manila Paper
1
i Fire Block Gypsum Board
1
i i
Gypsum Coreboard
w______________________
FIRE-HALT ; Gypsum Sheathing 1'
I i | i:I
C 442 IV X 1 a 1
Brown Water Vi" 2' 8**10' Square Resistant Face Paper
C442 IV R ' 1 a 2
1"
2'
8'-10'-12'
Tongue & Groove
Gray Paper
W2 a 2
C 79 II W2 a 1
Vi"
2'
8'
Tongue & Groove
Brown Water
Resistant
Vi"
4' 8'-9' Square
Paper
NOTES: (1) Other lengths available on special order. (2) Other edges available on special order.
(3) These products also available with a Super FIRE-HALT core formulation. (4) Available with (SJ) Tapered/Beveled edge.
3
attachment/application
nails -- The FLINTKOTE annular ring nail was developed to reduce or eliminate "nail pop ping." It is the shortest nail recommended with maximum holding power. This improved nail has greater holding ability than a cement coated nail of the same length. The annular ring nail's high carbon-steel content enables it to be driven fast. It meets the requirements of ASTM Designation C 380 "Nails for Appli cation of Gypsum Wallboard."
NOTE: All FLINTKOTE nails comply with the performance standards of the Gypsum Asso ciation. However, selection of the proper nail for each installation is most essential -- par ticularly for fire-rated constructions.
For nail sizes and spacing in fire and sound rated assemblies see "Guide to Fire Resist ance and Sound Transmission Ratings" pages 10 and. 11.
All wallboard must be drawn tightly against framing so there can be no movement of board on nail shank. In area adjacent to point of nailing, board must be held firmly against framing when nail is driven home. All nails shall be driven so that nailhead rests in a slight dimple formed by crowned head of driving tool without breaking paper.
screws -- FLINTKOTE Drywall Screws are spe cially designed for all types of gypsum wallboard applications, whether the framing is metal or wood or application is gypsum to gypsum. Made of high-strength carbon steel, FLINTKOTE screws drive fast. A phosphate over-coating serves as a rust-inhibitor. This avoids unsightly rust marks. The possibility of damaging the wallboard face paper is avoided by the bugle head. All depressions are uni form for easier spotting. FLINTKOTE screws designed for use with metal studs have a self tapping feature for rapid sure application.
NOTE: It is recommended that all screws be mechanically driven, for best results. Also, screws -- especially for fire-rated construc tions -- should be carefully selected and prop erly applied.
For screw lengths and spacing in fire and sound rated assemblies see "Guide to Fire Resistance and Sound Transmission Ratings" pages 10 and 11.
I i
i t
J
II I \
adhesive nail-on method -- This system of application pro vides for adhesive application of wallboard to wood framing with supplemental fastening. In addition to qualities provided by conventional fastening, the adhesive nail-on method:
Reduces fasteners about 50%, reduces incidence of loose board and minimizes nail or screw head concealment.
Because it provides a continuous area of contact between framing and wallboard, sturdier walls more resistant to sound transmission are to be expected.
A continuous bead of adhesive shall be applied to center of the face of all studs, joists, furring, etc. Where two adjacent pieces of wallboard join (ends or edges) on a framing mem ber, a serpentine or zigzag bead of adhesive shall be applied to provide proper bond. Size of adhesive bead shall be ap proximately %" by %" and cover at least 1" of framing member with Xt" thickness after wallboard is in place. For predecorated wallboard, parallel beads of a nonvolatile sol vent adhesive shall be applied along each edge of face of framing member where wallboard joints occur.
Nails shall be spaced no further than 16" o.c. on ceilings and 24" o.c. on sidewalls. Field nailing may be omitted on sidewalls if appropriate means (such as bracing or temporary nailing) are used to insure full contact of wallboard until ad hesive develops required bond strength.
A i 1
I
a.T^nj ozrlz'u
Suggested detail for horizontal bracing when required for steel stud partition.
TABLE 1 * -- Allowable Interior Partition Heights Based on Structural Properties of .022" (25 Gauge) Thick Galvanized Steel Studs to Bending Limits with 5 Lbs./ Sq. Ft. Horizontal Load.
STUB SPACINC
. 16"
j 24"
w 13'-1" 9'-3"
2W
15'-2" 12'-4"
STUD DEPTH
V/t"
354"
4"
6"
18'-0" 19'-5" 20'-10" 28'-0"
14'-8" 15'-10" 17'-0" 22'-8"
TABLE 2 s* -- Allowable Interior Partition Heights Based on Wallboard over .022" (25 Gauge) Thick Galvanized Steel Studs Acting as a Composite Section with a 5 Lbs./Sq. Ft. Horizontal Load and a Deflection Limit of 1/120 Height.
STUD DEPTH (In Inches)
1 STUD 'SPACING EACH SIDE 144" 2V4" 31/4" 344" r
r
: i6" Vi"-one-ply ll'-O" 14'-8" 17'-10" 19'-5" 20'-8" 18'-10"
; 24" ^"-one-ply lO'-O" 13'-5" 16'-0" 17'-3" 18'-5" 17'-8"
j 24" V2 "-two-ply 12'-4" 15'-10" 18'-3" 19'-5" 20'-8" 19'-0"
wall and ceiling systems
Development of the power driven self-tapping screw (Type S), Screw-On Studs, and Furring Channels has revolutionized application of gypsum wallboard for noncombustible construction.
Wallboard "stays put" when applied to metal framing members with Type S screws.
Versatility of the Screw-On System permits a range of choices in selecting economical fire and sound rated partition and ceiling assemblies to meet con struction requirements. Systems also provide effective fire-rated protection for columns and beams.
metal studs and track
Non-load bearing Screw-On Studsf and Track are roll formed from 0.0220" galvanized Grade A steel con forming to ASTM A 446-67 (hot dipped); or 0.0209" galvanized Grade C steel conforming to ASTM A 245-64 with electro galvanizing conforming to ASTM A 164-55 Type RS. Hot dipped galvanizing is recommended for areas of high humidity and salt air. Electro galvanizing is acceptable in all other areas.
Punch-outs are provided in web of stud to accommo date %" or iy2" stiffening channels, and they may be utilized in installing horizontal runs of electrical wiring or plumbing lines.
Screw-On Studs are available in widths of 1%", 2y2",
3%", 3%", 4", 6".
-) NOTE: Heavy Duty Studs of .0396 metal (20 gauge) are avail able. They are recommended for exterior walls and partitions of greater height limits than permitted for 25 gauge studs and for greater rigidity around door and window openings.
details
Metal or! Plastic Casing Bead
CEILING DETAIL
FLOOR DETAIL AND BASES
cYi rj
Suspended .Ceiling Tape and Joint Compound
TABLE 3 3 -- Allowable Partition Heights Based on General Accepted Performance.
STUD WIDTH
iy8" 2 Vi" 3W
STUD SPACING
16" o.c. 24" o.c.
16" o.c. 24" o.c.
16" o.c. 24" o.c.
LIMITING HEIGHT (1)
SINGLE LAYER D0U8LELAYER
(EACH SIDE)
(EACH SIDE)
8'-0" 8'-0"
lO'-O" 10'-0"
13'-0" 12'-0"
15'-0" 14'-0"
17'-0" 16'-0"
19'-0" 18'-0"
(1) Where studs are continuous through suspended ceilings to underside of floor or roof above, and ceiling adds stability to the partition, or studs are adequately braced from a point at or below specified limiting height, limiting heights may be increased 50%.
TABLE 4 0 -- Permissible Spans for .022" (25 Gauge) Thick Galvanized Steel Studs Used as Ceiling Joists Based on Stud Properties Only.
JOIST DEFLECTION SPACING LIMIT
STUD DEPTH
2Vi" : 3y" VM"
4"
G"
16" Bending 6'-ll" 9'-3" ll'-O" ll'-lO" 12'-9" 12'-10"
Span/ 5'-7" 7'-0" 8'-8" 9'-5" 10'-2" 14'-2" /360
O
oo
12" Bending 8'-ll"
12'-8" 13'-8" 14'-8" 17'-0"
r^.
LO
Span / /360
7'-9" 9'-6" 10'-4" ll'-2" 15'-7"
-Consult local code authority for governing criteria.
INTERSECTION
CORNER DETAIL
iii: on
The TRIMWALLTM Demountable Parti tion is a non progressive partition sys tem utilizing a steel framework, fire resistant gypsum wallboard and poly vinyl chloride receivers and batten strips. Anodized aluminum trims and door frames are available for various partitioning requirements.
. Demountability and re usability of the partition components are the system's outstanding features. Components not cut to special size can still be used after many relocations.
SOUND & FIRE RATINGS
f'j The TRIMWALL Partition is adaptable to full floor-to-ceiling height, cornice
" 1 height and rail partitions. Side lights and glass panels can be installed for special requirements.
The TRIMWALL Partition can be as sembled with FLINTKOTE Vinyl-Covered Gypsum Wallboard panels or FLINT KOTE Gypsum Wallboard to receive any type of decoration.
Erection can proceed with installation of the wallboard on one side alone to accommodate an immediate tenant. The opposite side can be finished later with FLINTKOTE Vinyl-Covered Wallboard to suit a future tenant.
Lab STC Ref
Construction
Fire Lab Rating Ref
35-39 CK
2V5" studs 24" o.c. V2" FLINTKOTE GWB
NA
-
1W studs 24" o.c.
14" FLINTKOTE
40-44 CK
GWB Mineral Fiber Insu
lation in stud
cavity
NA
-
2V5" studs 24" o.c. 35-39 CK Vs" Super FIRE- 45-min. EsL
HALT GWB
ZVi" studs 24" o.c.
44" Super FIRE-
40-44 CK
HALT GWB ' Mineral Fiber Insu
1 hour
uc 9/69
lation in stud
cavity
The framework of Screw-On Steel Studs permits easy installation of utility lines running vertically or horizontally.
LIMITATIONS -- Non-load bearing. Par tition height limit: 10'.
I
|
specifications
Materials -- TRIMWALL Aluminum Components are ex truded shapes -- minimum thickness of major components is .050". Finishes -- standard satin anodized. Available in Duronodic or equal finishes.
TRIMWALL Receiver #215 is a PVC extrusion designed to grip the flange of Screw-On Stud and provide a slot for the "T" Batten.
TRIMWALL "T" Batten #216 is a PVC extrusion designed to mate into the slot of the Receiver, hold the board tightly to the frame, and cover the joint. Finishes -- off-white, brown and black. Other colors on special order.
FLINTKOTE Gypsum Wallboard -- manila faced or vinyl sur
faced, beveled edge, y2" or s/a" thick, 48" width, standard
lengths.
Metal Studs and Track -- Non-load bearing Screw-On Studs and Track are roll formed from 0.0220" galvanized Grade A steel conforming to ASTM A 446-67 (hot dipped); or 0.0209" galvanized Grade C steel conforming to ASTM A 245-64 with electro galvanizing conforming to ASTM A 164-55 Type RS. Hot dipped galvanizing is recommended for areas of high humidity and salt air. Electro galvanizing is acceptable in all other areas.
SCREW -- Type S screws specially designed in point, thread, and head, for applying gypsum wallboard to metal studs.
Adhesive -- rubber or resin base -- H. B. Fuller Co., Miracle Adhesives Corp., Minnesota Mining Co., or equal. Do not use adhesives with solvent in applying vinyl surfaced wallboard.
General Framing -- Chalk lines locating partitions snapped on floor in accordance with plans. Partition intersections and openings marked.
Aluminum Ceiling Channel #201 secured with concrete nails, ackermann fasteners, toggle bolts or other acceptable fas teners, spaced 24" o.c.
2l/2" Screw-On Track secured with fasteners to floor 24" o.c.
Screw-On Studs, spaced 24" o.c., are friction-fitted in track and ceiling channel. (Note -- do not fasten studs to track except at openings.)
Headers over door or borrowed light openings made of track sections, cut to permit right angle bend.
Short Studs, friction-fitted in headers.
TRIMWALL Receiver #215 installed on stud at each wallboard joint.
Installation -- Initial panel fitted to existing wall with exposed edge plumb, slipped into ceiling channel and secured to bot tom track with 1" Type S screws, spaced 24" o.c.
TRIMWALL Receiver #215, applied to stud, positioned at edge of wallboard.
Intermediate Studs receive bead of adhesive.
TRIMWALL "T" Batten #216 driven into the Receiver with rubber mallet. Panel is drawn tight to framework. (Note -- If wallboard is to be painted, hold panel in place with 1" Type S screws at edges, mid height of panel. Apply TRIMWALL "T" Batten after the paint is dry.)
For One Hour Fire-Rated Partition: %" Super FIRE-HALT Gypsum Wallboard is applied with 1)4" Type S screws driven along the perimeter of the wallboard.
Prior to installation of second side of partition a 2Vi" thick, friction-fitting mineral fiber insulation batt is installed in stud cavity.
Door frames, glass railings and partition terminals are in stalled as detailed on opposite page.
Aluminum trim #209 or #210 may be used at ceiling inter section where metal ceiling track is installed.
Aluminum base #208 may be applied directly over the TRIMWALL ``T'' Batten.
6
details
wall and ceiling systems -]j j j <
ri ri
0^
ik
| tt.
T-
CEILING DETAIL
ALTERNATE CEILING DETAIL
~qm 1
T
209 1
210
-----------f-----------
DRIVE IN TRIM
m
203
Ja
204
TYPICAL MULLION
205
DOOR FRAME DETAIL
GLAZING DETAILS
BASE DETAIL
TYPICAL CORNER
207
DOOR HEADER DETAIL
? V
218
CASED OPENING DETAIL
7
gyp^T] 'tfaJJxjosrd panri:; :S
t
semi-solid/non-bearing, noncombustible
Narrow partition, speedily and economically erected. Semi
solid construction permits easy installation of electrical wiring
and reduces weight to approx. 6 Ibs./sq. ft. 1 hr. fire resist
ance rating with STC of 35 to 39. Allowable heights: 10' for
2V4" partition (1" rib +
GWB each side) and 2%" parti
tion (1%" rib + l/z" GWB each side), 12' for 2%" partition
(1%" rib + %" GWB each side).
specifications
Ail work shall be performed in strict accordance with plans and specifications. Partition application and procedures shall be in accordance with ANSI A97.1.
The three types of all-gypsum partitions shall be laminated constructions fastened to floor and ceiling by means of steel or wood runners. Wallboard face layers are laminated to either gypsum ribs (semi-solid partition) or to 1" gypsum coreboard (solid or double solid partitions). Partitions are considered noncombustible when ereeted with steel or fire retardant treated wood runners and combustible when erected with non-treated wood runners.
Runner Installation -- Floor and ceiling runners shall be in stalled with suitable fasteners spaced 24" o.c. (maximum). Use '`U" shaped steel runners (tracks) or wood runner with semi-solid partitions. Use "U" shaped steel runners (tracks), steel angle runner or wood runner for solid and double solid partitions. Note that a "U" shaped runner can only be used on the ceiling, or on the floor, but not for both locations.
PANEL ERECTION
Semi-Solid Partition -- Erect partitions with gypsum ribs (1" or 1%" x 6" of solid gypsum core or laminated wallboard) spaced 24" o.c. Partitions may be erected with pre-assembled panels (rib laminated to centerline of each panel), or ribs and panels may be erected individually. Panels shall be ver tically installed with joints staggered on opposite sides of
8
solid/non-bearing, noncombustible
Narrowest partition, speedily and economically erected. Solid partition (2" nominal) has a 2 hr. fire resistance rating and STC of 35 to 39. Approx. 8 Ibs./sq. ft. for 2" partition (1" coreboard + y2" GWB each side) and 9 Ibs./sq. ft. for 2%"
partition (1" coreboard + y8" GWB each side). Maximum
allowable heights with maximum 12' between restraints is 12' for 2" partition, 14' for 2%" partition.
4
iVj
partition. Laminate panels to ribs with sufficient adhesive to cover at least 75% of rib surface. If mastic type adhesive is used, apply serpentine bead of adhesive to ribs with crests %" from rib edges. Fasten panels to floor and ceiling track with l"'Type "S" screws 12" o.c. Supplement lamination to ribs with il/2" Type "G" screws driven 24" o.c. maximum along ribs.
Solid Partitions -- Erect partitions with solid base layer of 1" x 24" wide coreboard (solid gypsum with tongue and groove edges or laminated with ship-lap edges) vertically positioned and fastened to ceiling angle runner and floor runner or track with two 1%" Type "S" screws driven 4" from each panel edge. Laminate face layer panels vertically with recommended adhesives. Joints of face layer and coreboard shall be offset at least 6". Temporary bracing, or iy2" Type "G" screws may be used to maintain contact of face panels with coreboard until adhesive dries. Drive Type "G" screws a maximum of 36" o.c. along joints and vertical center lines. Fasten top and bottom of panel ends to floor and ceiling track with 1" Type "S" screws 12" o.c.
Double Solid Partitions -- Erect partitions with parallel rows of floor and ceiling angle runner or track, spaced as required for inclusion of services and ducts, or for desired sound rating. Erect coreboard and laminate face layer panels as specified for solid partitions. Allowable ceiling height may be increased by 2 ft. if horizontal internal stiffeners are added. Stiffeners may be single or spliced screw-on studs fastened to each coreboard layer with 1%" Type "S" screws 12" o.c.
i J
wall and ceiling systems
details
SEMI-SOLID
oint Compound i
i CORNER DETAIL
i Gypsum Rib
i
SOLID
PARTITION INTERSECTION
Finished
double solid/non-bearing, noncombustible
Provides expandable inner space for installation of service lines and ducts. Variation in double wail construction pro vides up to 3 hr. fire resistance rating and STC of 55 to 59. Partition weight is approximately 12V Ibs./sq. ft. Maximum allowable height with maximum 10' between restraints is 10' (12' with horizontal internal bracing).
ELECTRICAL SERVICE LINES Semi-Solid Partitions -- Install electrical conduit and boxes during panel installation. Provide for horizontal chases by cutting ribs short of floor or ceiling runners (maximum 6"). Vertical drops shall be made between ribs. Solid Partitions -- Cut electrical chases in coreboard layer just wide enough to install conduit. Where possible, make horizontal runs under or over partition. Do not disrupt con tinuity of-coreboard base layer any more than necessary. Double Solid Partitions -- Install electrical runs and wire drops in chase provided between coreboard layers.
RELIEF JOINTS Provision should be made at ceiling and intersecting walls when it is anticipated that partitions will be subjected to severe stresses from surrounding structural movement.
FINISHING Finish all joints and screw heads with the tape-joint system, in accordance with standard recommended and proven methods. For more detailed specifications refer to ANSI A97.1 for the Application and Finishing of Gypsum Wallboard or FLINTKOTE literature.
CORNER SECTION
FLOOR
PARTITION INTERSECTION
CORNER DETAIL
technical data
Fire and sound ratings were developed in stand ard A.S.T.M. tests at nationally recognized labora tories.
Sound Transmission Class (STC) performance of an assembly is given in terms of a range as various tests have produced slight variations. The integrity of the assembly must be maintained by sealing all openings, sealing perimeters, and treating joints.
Local code authorities should be consulted for fire and sound resistance requirements.
key to abbreviations:
CK Cedar Knolls Acoustical Laboratories
GH Geiger and Hamme Acoustical Laboratories
NBS National Bureau of Standards
ORC Ohio Research Corporation
/ OSU
Ohio State University Building Research Laboratories
RAL Riverbank Acoustical Laboratories
UL Underwriters' Laboratories, Inc.
UC University of California
INR Impact Noise Resistance
STC Sound Transmission Class
EST Estimate
FIRE HAZARD Classification
FLINTKOTE Gypsum Wallboard and Super FIRE-HALT Gypsum Wallboard
Flame spread: Fuel contributed: Smoke developed:
10-15 5-15 0
FIRE LAB NO. RATING REFERENCE
(concrete floor)
-
CONSTRUCTION ` ^ 1 i 1+) - 'vO At V '3 1 ''-Vi
|
2" concrete floor, 44" FLINTKOTE Super FIRE-HALT GWB nailed
l 1 hour
UL
with annular threaded nail spaced 6" o.c. to Vt" nailing channels at right angles spaced 16" o.c. attached to or suspended from
steel bar joists.
2" concrete floor, 25 gauge track fastened to opposing walls, or
2 1 hour
OSU
suspended. 25 gauge Screw-On Studs spaced 16" o.c., 44" FLINT KOTE Super FIRE-HALT GWB applied to studs (serving as joints)
with screws spaced 9" o.c. at end joints and 12" o.c. in the field.
3 1 Vi hr. UL
2" concrete floor, Vi" FLINTKOTE Super FIRE-HALT GWB applied with screws 12" o.c. to furring channels at right angles 24" o.c.
applied to or suspended from steel bar joists.
4 2 hour
UL
2Vz" concrete floor, V2" FLINTKOTE Super FIRE-HALT GWB applied with screws 12" o.c. to furring channels at right angles 24" o.c.
applied (0 or suspended from steel bar joists.
5 2 hour
UL
2W concrete floor, 44" FLINTKOTE Super FIRE-HALT GWB 2' x 2' Gypsum Drop-In Panels placed in fire-rated steel ceiling grid sus
pended from steel bar joists.
NO. v'-
1
2
3
FIRE RATING
LAB REFERENCE
??'iFlOsS'i?
1 hour
UL
1 hour
UL
SOUND STC (NR
LAB REFERENCE
|
ig ! c. i
-'5 b'W'- 11 u ,0;
35-39
-17
NBS
40-44 -6
EST
45-49 45-49 50-54
-4 +2 +15
CK CK CK
50-54
+2
2 hour
UL
50-54
+6
50-54
+20
EST
EST EST
CEILING CONSTRUCTION
|
W FLINTKOTE Super FIRE-HALT GWB applied with 5d nails 6" o.c.
Resilient Strips spaced 24" o.c. nailed at right angles to joist with 6d nails. 44" FLINTKOTE Super FIRE-HALT GWB fastened to Resilient Strips with screws 12" o.c.
Mineral Fiber Insulation installed between joists.
Wood floor surfaced with Cushioned Flooring.
Wood floor surfaced with carpet and pad.
44" FLINTKOTE Super FIRE-HALT GWB applied at right angles to joist with 8d nails 7" o.c. Resilient Metal Strips spaced 24" o.c. applied over first layer of wallboard at right angle to joist and- fastened to joists with 8d nails. A face layer of 44" FLINTKOTE Super FIRE-HALT GWB applied at right angles to strips and fastened with screws spaced 12" o.c.
Wood floor surfaced with Cushioned Flooring.
Wood floor surfaced with carpet and pad.
FIRE LAB NO. RATING , REFERENCE
5
i 1 hour
uc
SOUND
(STC)
LAB
WEIGHT PARTITION
RANGE REFERENCE LBS./SG. FT | THICKNESS
r ' jl* G/Aja, -L-
30-34
]i
EST 6-8 ; 2Ya"
CONSTRUCTION 44" FLINTKOTE Super FIRE-HALT GWB laminated to each side of 1" x 6" gypsum studs spaced 24" o.c.
2 1 hour
S2 J.3
OSU t
i
+++A Z.Z
50-54
ORC ; 9-10
'.i z.' 1 'lA-'A' . L A 2+
1 2 hour uc 35-39 EST
8-9
j 43A"
_1.
: a-
44" FLINTKOTE Super FIRE-HALT GWB laminated and screw attached to 44" FLINTKOTE Sound Deadening Board adhesively applied on both sides of 244" x 3" gypsum studs spaced 24" o.c.
r
1" FLINTKOTE Gypsum Coreboard fastened to top and bottom runners. 44" FLINT KOTE GWB adhesively applied to each side of Coreboard.
iI2~ is&di
_ +0. \
fn,
1 2 hour uc 45-49 RAL
n ; 4V4"
Parallel rows of 1" FLINTKOTE Gypsum Coreboard spaced minimum of 144" apart fastened to floor and celling runners. A face layer of 44" FLINTKOTE GWB ad hesively applied to outer side of both Coreboards.
2 3 hour
10
UL 50-55 EST
10-11
1
I1 _____________
1
5"
Parallel rows of floor and ceiling runners spaced 44" min. apart. Base layer of 44" Super FIRE-HALT GWB (or Backing Board) with 1" x 6" gypsum studs laminated . at 24" o.c. fastened to outside of each runner. A face layer of 44" Super FIREHALT GWB adhesively and mechanically applied with 144" Type G screws to base layer and to runner. Joints offset.
SOUND
FIRE LAB (STC) LAB WEIGHT PARTITION NO. RATING REFERENCE RANGE REFERENCE LBS./SQ. FT. THICKNESS
CONSTRUCTION t
.
.i (2" x 4" Wood Studs 16" o.c.. Except Where Noted)
. '
i 45 min. 1JL
30-34 NBS
5-6
4%"
Vi" FUNTKOTE Super FIRE-HALT GWB nailed to each side with 5d nails spaced 7" o.c.
2 1 hour UL 35-39 NBS
m
4%"
!
One layer FUNTKOTE Super FIRE-HALT GWB applied to each side with 6d nails spaced 7" o.c.
Resilient Strip applied horizontally 24" o.c. one side only. 54" FUNTKOTE Super
40-44 RAL
IVz
5y8"
FiRE-HALT GWB applied horizontally with 1" screws, 12" o.c. 54" FUNTKOTE Super FIRE-HALT GWB nailed to wood studs with 6d nails, spaced 8" o.c. on op
3 1 hour
uc
posite side.
45-49 RAL
4 1 hour OSU 45-49
GH
7% 5%" With Economy Mineral Fiber Batt Insulation in stud space.
| j
Base layer of 2" FUNTKOTE Sound Deadening Board applied vertically to each side with 5d nails, 24" o.c. at vertical edges and-16" o.c. at plate. Face layer of
10
5%"
W Super FIRE-HALT GWB adhesively applied (strips only) to each side and nailed with 8d nails around perimeter of wallboard, and at mid-height on inter
mediate studs.
5 1 hour OSU 35-39 NBS
i Base layer of 54" FLINTKOTE Gypsum Backing Board applied vertically on each
8,
5V4"
side with 4d nails 8" o.c. Face layer of 54" FLINTKOTE GWB applied on each side with 5d nails 8" o.c.
6 Wz hr. NBS
35-39
------------- 1--
7 2 hour OSU 45-49 _____ 1____ --L__ ---------------
NBS
11
5%"
Base layer of 2" FLINTKOTE GWB applied on each side with 5d nails 8" o.c. Face layer of 2" FLINTKOTE GWB applied on each side with 8d nails 8" o.c.
Base layer of Vs" FUNTKOTE Super FIRE-HALT GWB applied on each side with
CK
13
6 Vs"
'
6d nails 6" o.c. Face layer of Vs" FLINTKOTE Super FIRE-HALT GWB applied on each side with 8d nails 7" o.c.
-.......... .......... J --...... -J---- ------------------------ - ------------------------------------------ ---------
8 1 hour
--------
r~
!
NBS
1" Wood Drop with 11 gauge,
lSizdi"nglonogverroof2in"g
FLINTKOTE FIRE-HALT nails spaced 4" o.c.
Gypsum One layer
Sheathing nailed FLINTKOTE
10-11
53/4"
Super FIRE-HALT GWB applied with 6d nails 6" o.c. on inside surface. Mineral Fiber Siding or 1" minimum stucco cement piaster may be used in lieu of
wood drop siding.
9 2 hour
UL
38-40
10 Vs"
354" Brick Veneer with 1" air space over Vi' FLINTKOTE FIRE-HALT Gypsum Sheathing nailed with 11 gauge IV2" long roofing nails 6" o.c. Two layers of Vs" FLINTKOTE Super FIRE-HALT GWB applied to inside with 6d and 8d nails 8" o.c.
; g"
T
i 1 hour
o'. LULOI'i (Studs 24' o.c., Except Where Noted)
UC 35*39 RAL
One layer of Vs" FLINTKOTE Super FIRE-HALT GWB applied to each side of
5Vz
2%"
1Vs" metal studs with 1" Type S screws spaced 9" on edge of wallboard and 12" in field.
2 1 hour UC 45-49 RAL
5
3 Vi"
Omneetallasyteurds1/2w"ithFL1IN"TKTOypTeE
Super FIRE-HALT GWB S screws spaced 9" o.c.
applied to on edge of
each side wallboard
of 2Vi' and 12"
o.c. in field and 2" Mineral Fiber Insulation in stud cavity.
3 1 hour OSU 45-49 RAL
t~
45-49
EST
4 1 hour EST
Ode layer V2" FLINTKOTE Super FIRE-HALT GWB applied to each side of 2>/2"
5
3 Vi"
metal studs with aluminum batten strips fastened with 1" Type S screws spaced 12" o.c. and 2" Mineral Fiber insulation installed in stud cavity.
Two rows of lVa" metal studs spaced 254" apart, cross braced with 12" wide
6
7"
gypsum wallboard strips and 54" FLINTKOTE Super FIRE-HALT GWB applied to each outer face with 1" Type S screws spaced 9" o.c. at edges and 12" o.c.
in field.
50-54
RAL 6Vz
------------ ---------
With 1" Mineral Fiber Insulation in stud cavity of one row of studs.
5 1 hour UC 35-39 RAL
6
4%"
Vs" FLINTKOTE Super FIRE-HALT GWB fastened to each side of 354" nailable studs with nails spaced 8" o.c.
6 IVz hr. OSU
45-49
RAL
Two layers 54" FLINTKOTE Super FIRE-HALT GWB applied to one side 154"
8
4V4"
metal studs with t" Type S screws for base layer, and 154" Type S screws for face layer spaced 12" o.c. One layer 54" FLINTKOTE Super FIRE-HALT GWB ap
plied to other side with 1" Type S screws 9" o.c. on edge and 12" o.c. in field.
7 2 hour EST 50-54 RAL
Base layer of 54" FLINTKOTE GWB (or Backing Board) applied to each side of
354" metal studs with 1" Type S screws spaced 24" at the perimeter of the
9
5y8"
wallboard. A face layer of 54" FLINTKOTE Super FIRE-HALT GWB is applied with
154" Type S screws spaced 9" o.c. on edges and 12" o.c. in field. Mineral Fiber
Insolation in stud cavity.
8 2 hour UC
45-49
EST
' 50-54 RAL
Base layer of V2" FLINTKOTE Super FIRE-HALT GWB (or Backing Board) applied
9
3%"
to each side of 154" metal studs with 1" Type S screws spaced 12" o.c. A face layer of W FLINTKOTE Super FIRE-HALT GWB applied to each side with 154"
Type S screws spaced 12" o.c.
9V2
3%"
With 2" Mineral Fiber Insulation in stud cavity.
tJoint treatment NOT required for fire rating. Joint treatment IS required for sound rating.
FLINTKOTE
f" 'N * ' 1 `NM ` r!* ) ,
----- - --
'(>
'-k ? .'y
' `
. . . are manufactured to meet
exacting demands of all involved
in building construction
owner -- quality partitions and ceilings for a lifetime of use . . . fire and sound resistant.
architect -- a variety of systems providing fire and sound ratings to comply with Owner needs, and code requirements.
code authorities -- fire tested gypsum products and systems approved by accredited laboratories and properly identified to facilitate inspection.
builder -- competitive in cost, speed in construc tion, with a minimum of clean up time and interference with other crafts.
drywall contractor -- FLINTKOTE gypsum core is not only specifically designed to increase fire resistance ... it is resilient, adaptable to curved backing, may be fastened and handled with a minimum of damage ... it scores evenly and breaks clean.
decorator -- FLINTKOTE facing paper is designed to accept any type of decoration . . . texture, paint, wallpaper or vinyl decorator materials.
The specifications herein contain the best information we have relating to our products, and the recom mended uses of our products are based on tests be lieved to be reliable.
warranty
FLINTKOTE warrants that the products described here in are of merchantable quality BUT DOES NOT WAR RANT THEIR FITNESS FOR ANY PARTICULAR USE OR PURPOSE OR MAKE ANY OTHER WARRANTY, EX PRESS OR IMPLIED. This warranty may not be enlarged or extended by our sales representatives, written sales information or drawings.
Liability of FLINTKOTE under this warranty is limited to replacement of its products found to be defective or, at its option, a refund of the purchase price.
All advice given and structural specifications supplied by FLINTKOTE representatives shall be used at the sole risk of those receiving the same, and FLINTKOTE as sumes no responsibility for the design or construction of any structure in which its products are used. Any review or inspection of plans, buildings or product ap plications by FLINTKOTE representatives is not to be construed as approval thereof by FLINTKOTE.
These specifications supersede all previous issues and are subject to change without notice.
distribution center / flintkote supply co.
Dallas, Texas
214-241-3238
Houston, Texas
713-467-3411
Oklahoma City, Oklahoma
415-946-0581
GYPSUM PRODUCTS DIVISION
480 Central Avenue East Rutherford, N. J. 07073
Atlanta, Georgia
Boston, Massachusetts Camden, New Jersey (Philadelphia Area)
Charlotte, North Carolina
Chicago Heights, Illinois (Chicago Area) Detroit, Michigan Fremont, California (San Francisco Area)
Hershcy, Pennsylvania
Los Angeles, California
Lyndhurst, New Jersey (New York Metro Area) New Albany, Indiana
New Orleans, Louisiana Portland, Oregon Salt Lake City, Utah
St. Louis, Missouri
F-800-71
THE FLINTKOTE COMPANY
404-351-5355 617-326-8802 609-966-1234
704-334-1616 312-757-7000
313-837-1605 415-793-9100
717-533-3500 213-749-4242 201-438-2800
812-945-9161 504-944-0393 503-228-6411 801-322-2211 314-966-6977
i
Printed in U.S.A.