Document 10K4L4M3v0Ybz4OE444LzBg5j

technical catalog bulk API and AP packaged oil-fired boii hot water 4Mkl(, _:i r___ i WII-III 9U APT urtd AP bo ii'ers... cast iron, completely packaged tor fast installation The compact APT meets the need tor an oil-fired hot water boiler that can furnish, at low cost, both the su perior quality of hydronic heat and a dependable supply of domestic hot water. It comes completely packaged with an l=W=H rated tankless coil. If a tankless coil is not required, the same unit is available without heater as the AP boiler. Both the APT and AP boilers are avail able in 4, 5 and 6 section sizes--with l = 8=R approved ratings in the important 95,000 to 165,000 Btu/hr. range. Compactly packaged to easily Tit through a door way, the boilers come equipped with factory-mounted, pre-wired controls for fast, easy installation. Rugged cast iron sections, precision DH-5 oil burner, and ELIMINAIRE* design, guarantee durability, economy and efficiency in operation. For the finest in cast iron-and the fastest in installation-select the APT or AP boiler! to expansion- tank to system ELIMINAIRE* - a patented cost-saving American-Stand ard feature-is 1 ntegra I ly cast into the left hand end sec tion on all APT and AP boil ers. The ELIMINAIRE* baffle diverts rising air bubbles directly into the expansion tank through a special tap ping in the section. No ex ternal device is necessary to separate air and water. air eliminator baffle t-controls--combination light-sensing prim ary and triple immersion control is factorymounted, pre-wired on the APT. (The AP has separate limit and primary controls.) 2 2- water heater-provides ample supply of domestic hot water; |=w=H ratings. 3-- cast iron sections-multiple pin-type pro jections extract maximum heat from flue gases. Sections are tested at 2V2 times maximum working pressure. 4-- front cleanout panet--one-piece panel al lows full cleaning of all flue surfaces from the front-a big advantage in close clear ance installations -- without disturbing burner, controls and accessories. 5- jacket-smartly styled of sturdy steel in sparkling gray finish; fully insulated. 6-- model DH-5 oil burner-with quickconnect sling mount for simple hanging. Specifically designed for APT and AP boil ers. Easy-to-adjust EXACTAIRE control assures proper air-oil mixture for clean, economical firing. Special ceramic turbulator and stainless steel air tube assure long burner life. 7- insuiated steel base--firmly supports cast iron sections and encloses refractory com bustion chamber to keep jacket tempera tures low. EXACT-AIRE and ELIMINAIRE ara trademark* of AMEHICAN-STANDARP Inc. High-capacity Tankless Water Heater-is individually sized and factory installed as stand ard equipment on each APT packaged boiler. Specifically designed for forced circulation boilers, the copper coil fits into the extra large 5" nipple port at the top of the section. High l = W = H approved ratings have been con firmed by actual test in the boiler. and AP packaged oil-fired boile APT and AP ratinat tanklefi hegfer rgfin boiler number with leu tankless tankleu heater heater frou l-B = R output (Btu/hr) net l=B=R ratlnna (Btu/hr) l=B=R burner capacity* (gph) chimney size height (inches) (feet) water content (gallons) APT-95 APT-130 ' "APT-165 AP-95 AP-130 AP-165 95,000 130,000 165,000 82,600 113,000 143,500 0.95 1.25 1.60 8x8 8x8 8x8 15 9.6 15 11.7 15 13.7 Netl = B = R ratings shown sra based on s piping end pick up allowance of 1.15. American-Standard should b consultad bafora selecting a boiler for Installations having unusual piping and pick up requirements. Noma alias, gph, 60S, fumlihad with APT and AP packagad hot watar bdlarsi APT/AP-95, 0J6| APT/AP-1M, 1.23| APT/AP-165, lJO. (Baaad on oil at 140,000 Btu palr gallon.) bolltr number l=B=R burner capacity (gph) heatar numbar* l = W=H ratings (gpm)A pressure drop (pal) APT-95 0.95 218 244 APT-130 1.25 222 3V4 APT-165 1.60 230 344 7 12 22 a Oomastlc hot water connection alias for all haatars la W I.P.S. A Gallons of watar par mlnuta hastad from 40 F to 140 F with 200 F boiler water temperature. dimensions and tappings 1%*(, lfi%--* 2' flow boiler number size of tappings with tankless heater less tankless heater number of sections (inches) flow return dimensions (inehaa) A BC . APT-95 APT-130 APT-165 AP-95 AP-130 AP-165 4 5 6 2 144 21VSz 1444 6 2 1V4 2444 1744 6 2 144 28 2044 7 4544 side view *1 h--b--*1 front view craved dimensions boiler number with less tankless tankless heatar heatar APT-95 APT-130 APT-165 AP-95 AP-130 AP-165 dimensions (inches) H WL 4644 4644 4644 2144 2144 2144 2344 2744 3044 approximate shipping wt. (lbs.) APT AP 484 470 548 537 621 607 side new front view APT and AP packaged oil-fired boilers are designed and built to comply with the American Society of Mechanical Engineer's Code, and bear their approval symbol. Ratings have been approved by the Institute of Boiler and Radiator Manufacturers. The Model DH-5 Oil Burner Is listed by the Underwriters' Laboratories, Inc. for No. 1 and No. 2 fuel oil; complies with Com mercial Standard CS-75; and is approved by the New York City Board of Standards and Appeals, by the State Fire Marshal of the Commonwealth of Massachusetts, and by the Department of State Police, State of Connecticut. AMERICAN STANDARD and AP packaged oil-fired boilers near boiler piping /+ return \ relief valve expansion tank Procedure for filling lerfes loop Heatrim System: 1. Close all zone valves except zone to be purged. 2. Open trailer drain valve. 3. Open fill valve. 4. Close purge valve. 5. Vent air from boiler by manually opening relief valve. 6. Open second valve to be purged. Close first zone. After second zone Is purged, open third zone valve and close second zone. Repeat for as many zones as in system. (Note: Always have one zone vahro open.) 7. When all zones have been purged, close boiler drain cock. 8. When water appears at relief valve, release lever and allow to close. 9. Continue filling until pressure gauge reads approximately 12 Ibs./sq. in. Close fill valve. 10. Open purge valve. Note 1: Where multiple circuits are used without zone valves, sauare head cocks should be Installed for balancing. These square head cocks can be shut off to purge each circuit In turn. Note 2: For a single loop Hestrfm System, no additional vents, cocks, valves, drains, or other accessories ere requlred-wlth one exception, if tankless heater Is used and Heatrim is above the boiler outlet, a flow check valve must be installed to prevent gravity circulation. Form No. 738*? /Rev. 4/711 PLUMBING / HEATING P.O. BOX 2003. NEW BRUNSWICK. N. L 08903 i :.L.