Document 101p8QO8GN6pyVEDONLpzEY1d
American Society of Heating and Ventilating Engineers Guide, 1929
Screw pumps may be used with good economy for small capacities.
Since the capacity and pressure at which screw pumps will operate is almost infinite, we can only give some idea of their capacity. Efficiencies range frcm 60 to 70 per cent.
Table 1. Direct Acting Steam Driven Duplex Reciprocating Boiler Feed Pumps
Dia.
Dla.
OF OF
Steam Water
Cyl.
Cyl.
in IN
Inches Inches
Length
of Stroke in Inches
No. OF .
Strokes
per Min.
Discharge in Gallons
Per Per Stroke Min.
Equiva
Boiler
H. P.
s ize Pipe , INCHXts
lent
Served
Dia. of Single
Cyl.
Without Factor
of
Steam
> Ex haust
Suc Dis tion charge
Pump
Safety
3
iM s'H 6~
7K 714
10 12
'2
2% 3H 4
4M 5 6 7
3 4
5
6 6 TO 10 12
70 0.04 5.6 2%
80 K K ik i
60 0.10 12.0 4
180 K K ik 1M
50 0.20 20.0 5
m50 0.33 33.0 3%
50 0.42 42.0
m300 K ik 2
i/4
480 1
214 2
600 IK 2
3
2K
40 0.85 68.0 7
1000 ik 2
3
2/4
40 1.22 97.6 8>4 1400 2
2K 4
3
35. 2.00 140.0 9Vs 2000 2K 3
5
4
Table 2. Horizontal Duplex Piston Packed Power Driven Boiler Feed Pumps for 100 Lb. Working Pressure
Size of Pump Cylinders
in Inches
Dia. Stroke .
No. of Revolu
tions per Min.
Displacement Gallons
Per Rev. Per Min,
2\4 4 34
3H 5 46
8 10
30 : 0.34 30 0.49 30 0.83 25 1.30 20 8.69
10.2 14.7 24.9 32.5 173.8
Boiler
H. P.
Served Without
Factor of Safety
148 213 361 471 2520
H. P.
Required to
Drive Pump
1.5 4.0 3.5 4.0 18:0
Pipe Sizes Inches
Suction Discharge
ik i K 2
2K 2
3 214 54
Table 3. Reciprocating Single Acting Power Driven Triplex Boiler Feed Pumps for 150 Lb. Working Pressure
Size of Pump Cylinders
in Inches
Dia; Stroke
No. of
Revolu
tions per Min.
Displacement Gallons
\
Per Rev. Per Min.
Boiler
H. P.
Served
Without
Factor
of Safety
l\4
1M 2 2K
3 4 .. 4 5 6 8
2
214 3 4 4 4
6
8 8
10
50 0.045
2.25
50 0.078
3.90
40 0.122
4.88
30 0.255
7.65
30 0.367 11.01
30 0.652 19.56
25 0.978 24.45
20 2.041 40182
20 2.938 58.76
20 6.520 130.40
33 , 57 70
110
160 280 355 592 852 1891
H. P.
Required to
Drive Pump
0.40 0.65. 0.80 1.15 1.40
2.6
3.10 5.00
6.00
14.00
Pipe Sizes Inches .
Suction Discharge
.. k
i
iK ik ik
2
2H 3
314 4 '
1K 1 IK' `
IK
IK
2
2/4 3
3
Chapter XVIII--Pumps and. Traps for Heating and Ventilating Equipment CONDENSATION PUMPS
Condensation return pumps are generally of one of the following two typos: (1) automatic pumps and receivers, (2) continuously operating non-automatic return pumps! Automatic Pumps and Receivers
The volumetric capacity of receivers for electrically-driven pumps should be not less than three times the maximum minute volumetric flow of
Fig. 1. For Selection of Size and Stage of Centrifugal Boiler Feed Pumps
condensation to be handled, measured between the high and low water lines in the receiver. For direct acting steam-driven pumps the receiver capacity may be less than for electrically-driven pumps.
The piston speed in feet per minute should not be more than 10 times the square root of the number of inches in the length of stroke.
The volumetric displacement rate of water pistons should not be less than three times the maximum volumetric rate of the flow of condensate to be handled.
The normal capacity of centrifugal pumps should not be less than twice the maximum rate of flow of the condensate to be handled.
289