Document 101p8QO8GN6pyVEDONLpzEY1d

American Society of Heating and Ventilating Engineers Guide, 1929 Screw pumps may be used with good economy for small capacities. Since the capacity and pressure at which screw pumps will operate is almost infinite, we can only give some idea of their capacity. Efficiencies range frcm 60 to 70 per cent. Table 1. Direct Acting Steam Driven Duplex Reciprocating Boiler Feed Pumps Dia. Dla. OF OF Steam Water Cyl. Cyl. in IN Inches Inches Length of Stroke in Inches No. OF . Strokes per Min. Discharge in Gallons Per Per Stroke Min. Equiva Boiler H. P. s ize Pipe , INCHXts lent Served Dia. of Single Cyl. Without Factor of Steam > Ex haust Suc Dis tion charge Pump Safety 3 iM s'H 6~ 7K 714 10 12 '2 2% 3H 4 4M 5 6 7 3 4 5 6 6 TO 10 12 70 0.04 5.6 2% 80 K K ik i 60 0.10 12.0 4 180 K K ik 1M 50 0.20 20.0 5 m50 0.33 33.0 3% 50 0.42 42.0 m300 K ik 2 i/4 480 1 214 2 600 IK 2 3 2K 40 0.85 68.0 7 1000 ik 2 3 2/4 40 1.22 97.6 8>4 1400 2 2K 4 3 35. 2.00 140.0 9Vs 2000 2K 3 5 4 Table 2. Horizontal Duplex Piston Packed Power Driven Boiler Feed Pumps for 100 Lb. Working Pressure Size of Pump Cylinders in Inches Dia. Stroke . No. of Revolu tions per Min. Displacement Gallons Per Rev. Per Min, 2\4 4 34 3H 5 46 8 10 30 : 0.34 30 0.49 30 0.83 25 1.30 20 8.69 10.2 14.7 24.9 32.5 173.8 Boiler H. P. Served Without Factor of Safety 148 213 361 471 2520 H. P. Required to Drive Pump 1.5 4.0 3.5 4.0 18:0 Pipe Sizes Inches Suction Discharge ik i K 2 2K 2 3 214 54 Table 3. Reciprocating Single Acting Power Driven Triplex Boiler Feed Pumps for 150 Lb. Working Pressure Size of Pump Cylinders in Inches Dia; Stroke No. of Revolu tions per Min. Displacement Gallons \ Per Rev. Per Min. Boiler H. P. Served Without Factor of Safety l\4 1M 2 2K 3 4 .. 4 5 6 8 2 214 3 4 4 4 6 8 8 10 50 0.045 2.25 50 0.078 3.90 40 0.122 4.88 30 0.255 7.65 30 0.367 11.01 30 0.652 19.56 25 0.978 24.45 20 2.041 40182 20 2.938 58.76 20 6.520 130.40 33 , 57 70 110 160 280 355 592 852 1891 H. P. Required to Drive Pump 0.40 0.65. 0.80 1.15 1.40 2.6 3.10 5.00 6.00 14.00 Pipe Sizes Inches . Suction Discharge .. k i iK ik ik 2 2H 3 314 4 ' 1K 1 IK' ` IK IK 2 2/4 3 3 Chapter XVIII--Pumps and. Traps for Heating and Ventilating Equipment CONDENSATION PUMPS Condensation return pumps are generally of one of the following two typos: (1) automatic pumps and receivers, (2) continuously operating non-automatic return pumps! Automatic Pumps and Receivers The volumetric capacity of receivers for electrically-driven pumps should be not less than three times the maximum minute volumetric flow of Fig. 1. For Selection of Size and Stage of Centrifugal Boiler Feed Pumps condensation to be handled, measured between the high and low water lines in the receiver. For direct acting steam-driven pumps the receiver capacity may be less than for electrically-driven pumps. The piston speed in feet per minute should not be more than 10 times the square root of the number of inches in the length of stroke. The volumetric displacement rate of water pistons should not be less than three times the maximum volumetric rate of the flow of condensate to be handled. The normal capacity of centrifugal pumps should not be less than twice the maximum rate of flow of the condensate to be handled. 289