Document 0qeO3q9MnD5dJ48xVVLZLDLzx
*""y--
--
1 ` l WoHPSotO
Internal Correspondence
Date: ApriMO, 1987 To: All Field Sales Offices and Distributors
SALES DEPARTMENT LETTER #87-7
Copy:
From: Paul S. Showalter
I :
Subject: Asbestos Update
. /"iO ' ,
___________________________________ ___ .______________________________;.....*...V..... ' i V
This is further update on the status of the asbestos friction materials use in some df-our products.
On June 20, 1986 OSHA put into effect amended rules regarding occupatiprial expo^ire to. asbes
tos (29 CFR Section 1910.1001). These new rules reduce the permissiblPS-hour, fim^weighted ex
posure limit from 2 fibers to 0.2 fibers per cubic centimeter and significantly change an employers
responsibilities
^
Sh *
'
\, ' }
A new "action level" of asbestos concentration was established.aLOi.l fibers- per.eublc centimeter,
if there is reason to believe that his employees are exposed .to. asbestps concentrations at or above
this level, then the employer is compelled to undertake a mpqitoring program to evaluate the actual
exposure levels, if this monitoring confirms that the ashestips'concentratibns exceed the "action
level", then the employer must institute employee training strict mfedica! surveillance programs at no.
cost to the employee.
. ; j'
if the asbestos concentrations exceed the newjower permissible exposure values, then the employer must take a number of additionaiact]6ps including1 posting signs warning of the asbestos
hazard, limiting access to the hazardous atea and following- specific requirements concerning protective clothing and the disposal of-.waste!' In addition the employer is compelled to initiate programs to reduce the exposure levelsby engineering controls such as exhaust ventilation and
use of respirators.
As we have previously indicated (see SaletrDept. Letter 86-04) it is Eaton's opinion that the amount of asbestos liberated into the erivironmerifby the normal operation of our products with asbestos friction material is quite small.-:-The likelihood of creating airborne fiber concentrations approaching the new "action level" appears to ^significant only if the customer grinds, sands or otherwise
machines the biocks.Cpfdf inappropriate methods (such as sweeping or blowing with compressed air instead of vacutimihg} are usedio clean up .any friction residue that may be created by the unit. However, we cariri6t.knowthe..specific application, environment, maintenance, clean up proce
dures, and presence of otherasbestos sources at a customers facility. The regulations place the responsjbiljtyTpr determining if the levels need to be monitored on the employer.
In order toTempve-Qf minimize the presence of asbestos as a problem in the workplace, we are proceeding to adopt rion-asbestos material as standard for all of our product lines. Over the past few months we have been depleting our inventory of asbestos friction materials by using it to fiil or ders where .the customer has not explicitly asked for non-asbestos materials. However, any orders received,after April 1,1987 for our CB, VC, E, EB, VE, DBA, DP and HD product lines for use in v -non-slip Applications will be shipped with non-asbestos friction only. As soon as our current order backlo'g is cleared, the balance of our asbestos inventory will be scrapped and we will no longer
provide asbestos linings for these products even if specifically requested by the customer.
. - As of this time, we have yet to find a suitable non-asbestos material for use in the CS, CSA and iCTE product lines nor a slip material for the VC, DP and HD product lines. While we continue our
1; search for appropriate materials, asbestos linings will continue to be used on these products. If we
do not come up with a new material in the next several months, other modifications may have to be made.
J
Paul Showalter
FAW 17190