Document 0qbxyV59aG1z2RaZ48LMw2YGk
Size-Selective Gravimetric Sampling in Dusty Industries
HOWARD E. AYER. GLEN W, SUTTON, and IRVING H. DAVIS*
,(trcupational Health Program. National Center for Crban and Industrial Health Cincinnati, Ohio 45202 and Dirtsion of Occupational Health, Michigan Depot tmeni of Public Health, Lansing, Michigan 489N
0 SfaccHKlectivc gnivwHilric Mrapira* wu conducted along with aaffitpUng by itnpingcr for dutt in 22 foundries.. Three-hour personal samples were taken with a
10-nun cyclone to remove nonrespirable dust, and with a polyvinyl chloride membrane filter to collect a dust sample for weighing. Respirable free silica was determined on samples passing a horizontal eiotriator. The evaluation of the potential silicosis hazard
by a gravimetric limit was not inconsistent with judgment of the hazard based on impinge; samples and the present ACGJH Threshold Limit Value. Size-selective gravimetric sampling is recommended as an alternative to imptnger sampling.
Introduction
the criterion suggested at a special meeting
THE USE of size-selective sampling and sponsored by the U. S. Atomic Energy Com" weight concentration of "respirable" dust mission (AECi in Los Alamos in 1961.'* in evaluating inhalation hazards has beenBeckmans5 has demonstrated mathematically
reviewed by Hatch and Gross1 and by Mor that, for typical industrial-dust size distribu
row.- The advantages of this technique in tions, weight fractions of respirable dust
clude the ability to sample over a full shift would be approximately the same under
or a major fraction thereof, automatic com either criterion. Laboratory and industrial
pensation by the size-selective device for shape, samplings by the V. S. Public Health Service
density, and degree of agglomeration of dust, Occupational Health Program confirm his
the ability to use personal samplers to obtain calculations.
truer "breathing-zone" exposures, the greater
Samplers using horizontal elutriators that
possibility as contrasted with optical count meet the MRC criterion are commercially
for standardizing weight determinations, and available. The 10-millimeter-diameter cy
a much lower cost per determination of clone described by Lipmann and Harris1'' was
weighted exposure to dust.
found by Sutton1 to approach the AEC cri
Two major criteria for selection of a "res terion at a flow of 2.0 liters per minute
pirable" fraction are the criterion adopted {1pm! and is readily available commercially.
by the British Medical Research Council Other devices said to approach this criterion
(MRC 'i and confirmed by the Pneumoconio at higher flow rates are also available, but
sis Conference in Johannesburg in 1959" and calibration by aerodynamic size has not yet
been reported.
A major deterrent to extensive use of size-
selective gravimetric sampling by industrial
*H. F. Aver and C. W. Suttcur arf with tbr National Center for Urban and Industrial Health. I, H. Davi> h with the Michigan Department of Public Health.
Mention of commercial concern?, or products does nor constitute endorsement by the Public Health Service or the
U. S. Department of Health. Education and Welfare.
hygienists has been the absence of a suggested hygienic limit for this sampling technique. Reno rt al.- reported a study in the Barre. Vermont, granite sheds which attempted to
336
!;can Industrial Hygtrnc Association Journal Amt
e
337
tapped nylon cap
!Om CYCLONE . DORR OLIVER No. 265*11 /4A VORTEX PlNOER , DORR OLIVER No 285*1 /*fl UlCITE CONNECTOR fCn*ntwf *> No 55 AEROSOL MONITOR WITH 37mrr MEMBRANE Ell TER ELASTIC BAND WITH CLOTHING CLIP 6-0 LUER TO "hOSE CONNECTOR, LH/L 52" {" 1.0, RUBBER TUBING
NYLON BAND WITH CLOTHING CLIP
BATTERY POWERED DIAPHRAGM PUMP (with Writ clip) ALUMINUM PLATE SPRING CONNECTORS (3)
Figure 1. Personal sampler for respirable mass samplin'*.
determine an equivalent for the 10 million particles per cubic foot (mppcfl suggested as a limit for Barre granite dust by Russell,8 Results of this study were inconclusive. Fur ther comparative sampling was conducted in
1966, The combined results of the 1965 and
1966 studies are said by Sutton and Reno11' to indicate that 10 mppcf of granite dust will give 0.1 milligram of free crystalline silica per cubic meter (mg/m3! in the respirable fraction. On the basis of this 0.1 mg of res pirable free silica per cubic meter, they sug gested a formula analogous to the dust count threshold limit value fTLVs of the Ameri can Conference of Governmental Industrial Hvgienists fACGIR' for mineral dust:
Resp. mg/m1 = I0/{%RFS + 2) where % RFS = percentage of free silica in the respirable fraction. The milligrams of respirable dust per cubic meter is measured by a size-selective sampler in accordance with
one of the criteria previously mentioned. It must be emphasized that the percentage of free silica is that in the respirable fraction, because in 1936 Hatch and Moke11 and in 1947 Holden et aid- reported that the per centage of quartz in the respirable fraction is much less than that in a gross sample of airborne foundry dust. Data reported herein confirm this fact.
Further causes for delay in the introduc tion of size-selective mass sampling include
338
July-August, }%a
jlmfrican Indust
the unavailability of suitable samplers until Survey Procedures
very recently, controversy over the merits of one size-selective criterion versus another, the previous unavailability of analytical methods for free silica in small samples, and the nat ural hesitation to reptace or supplement a familiar technique with an unfamiliar one.
The sampling reported here was designed to determine:
The size-selective sampling was conducted ap an adjunct to an impinger sampling SUJV
vey of a number of foundries by the Division of Occupational Health, Michigan Depart ment of Public Health. The personal, s;ze. selective gravimetric samples were taken for 2/2 to 3 hours: an impinger sample was taken in the same man's `breathing zone" for io
Foundry
I
s.
m
1. Whether commercially available equip minutes during this period. Similar pro.
ment (with minor modification) was eedurcs were used in surveys of two foun
suitable for personal size-selective samp dries in a neighboring state.
ling for dust concentration.
!,
Which equipment could be used for
The impinger samples were counted by the ACGIH procedure.'15 The filter mem
obtaining `(respirable" dust for free branes were weighed (usually twice) on a
silica determinations.
0.01-mg sensitivity single-pan analytical bal
3, Whether there were any unusual prob ance or on a Cahn "Gram'' electrobalance
lems associated with the use of such before sampling and twice after sampling on
equipment.
the same balance.
4. Whether inhalation hazard assessment by size-selective sampling and size-se lected free silica was generally consis tent with assessments by impinger samp ling and gross airborne free silica.
For personal sampling, a 10-mm nylon cy clone, a plastic, filter holder with 37-mm polyvinyl chloride membrane filters (nominal pore size 0.8 micron), and a battery-powered diaphragm pump were connected as shown in Figure 1.
Four different size-selective samplers were used to obtain samples for free silica deter mination.
The free silica samples were taken in the general area of the operations being sampled by impinger and persona! samplers. At some locations a shop cart was set up to take Aerotec "2.1' Unico 18, and 10-lpm hori zontal elutriator samples simultaneously. At each of these locations a gross airborne dust sample was taken, and gross airborne dust samples were also taken at a number of loca tions where no size-selected free silica samples were taken.
High-volume, gross airborne dust samples and Del cyclone-separated samples were an alyzed by an x-ray diffraction procedure.
Avii. through 17 47
number of ran
free silica in the from 1,3 to 13.7, determined from horizontal elutriatt
Correlation bed and 150- to 1B( samples for the er. poor. The ratios tides per cubic fo.
Aerotec "2" samples were analyzed by the
per cubic meter '
Sampler
Sampling Rate
Aeroter ll2i: cyclone*1
Unico 18 cyclone
Horizontal elutriator (according lo Hamilton and Walton'4)
Del electrostatic precipitator with 1*4-inch cyclone
35 cfm 18 Ipm 10 1pm
Maximum
Cellulose Ester
Membrane filter Size
8X10 inches 37 mm 3~ mm
Gross airborne dust samples for free silica were taken with a high-volume sampler and a 4-inch-diameter pleated cellulose paper filter.
phosphoric acid method of Talvitie.16 For horizontal elutriator samples and Unico 18 samples, the phosphoric acid method was used with the colorimetric silica method of Talvitie and Hvslop.17
Results
Two hundred and eighty-three respirable mass-impinger count sample pairs collected during the winter of 1966-1967 are reported herein. Fifty-five gross airborne samples and fourteen respirable samples were analyzed for free silica. The percentage of free silica in gross airborne dust samples ranged from 4 to 62 with a mean of 23%. The percentage of
mean of 8.2; the d standard geometric part of this variati
the fact that the in fifteenth or so of th pier was operating,
indeed, increase the the fact that the 28 standard geometric their geometric me the respirable mass geometric mean of
The samples wer as follows: (1) sane pouring, (3) hooko ing cleaning, and
July-August, 1968
pling was conducted linger sampling surdries by the Division , Michigan DepartThe personal, sizeiples were taken for ;er sample was taken uhing zone" for 10 riod. Similar prorvevs of two foun ts te.
5 were counted by * The filter memsually twice! on a -pan analytical balam" electrobalance * after sampling on
ere taken in the >ns being sampled samplers. At some is set up to take and 10-lpm horiimultaneouslv. At ;ross airborne dust ross airborne dust a number of locafree silica samples
ome dust samples samples were anaction procedure. analyzed bv the >f Taivitie.1* For es and Unico 18 1 method was used uethod of Talvitie
American Industrial Hygiene Association Journal
339
Foundry
ITable
Impinger Count and Respirable Mass Concentration by Operation Group and Establishment
Sand Muting Molding and Pouring Hfooko*Shakcout
Craning
ft* mppcf mf/m* n mppcf mg/m1 n tnppcf OTSf/fitt1 31
mg/m1 a
Core Room mppcf oj/'a*
1
I
6 S3
2.1 3 19
2.1 to 17
2.2 12 IS
2.5 2 81
2 64
1.2 3
15
14 7 26
3.8 4 39
1.7 1 25
3
S 15
1.7 1
12
0.8 10 13
2.0 3 19
2.0 --
--
4
2 14
3.9 3
13
2,0 2 12
2_2 4 9.4 3.0 3 7.8
5
2 21
3.0 2
9.2 1,6
6 14
i.T 5 13
2.0 --
--
6
4 13
1.7 4 47
1.0 1 24
1.5 3 IS
2.7 3 10
7
2 57
1.7 --
--
6 16
1.5 5 34
1.5
--
3
2 ti
1.4 4
5.2 0.9
7 16
2-2 4 15
3.1 --
--
9
2 340
1.6 3
4,6 0.7
5 16
i.i 2 7.8 1.8
--
10
1
4.6
2.0 --
--
----_
~~
5 29
2.1 -- --
11 12
-- *-- -- 2 4.1
3
6.8
1,8 1
23
i.a -- -- 2.6 9 5.5 2 2
2 3
2.5 31
0,6 2 1.9 --*
2.8
--
13
1 97
U 4 18
i.t 2 27
1.2 3 29
1.8 -- ~
14 t 1.7 IS 2 3.9 2.3 4 4.0 2.2 3 6,2 1.8 1 3.1
15
2 15
2.6 I
7.6 1.7 -- __
--
7 34
2.9 -- --
16
7 38
1.6 8
6.6 0.9
4
7.4 1.3 13
6.7 1,6 5
9.0
17
s 20
0.9 6 5.7 1.4 4 7.0 1.5 6 19
u 5 11
18
3,5 0.8
8 1.2
8 1.8
8 0.7
2
19
20 2[
13 94 350 4.3
26 1.4
6 0.4
6 0.8 10 2.2
-- ---
8 1.3 4.5 2.4
-- TM
18 0.7 20 1.5
2
-- --
22
11 1.9
12 5-4
4 1.3
7 4.1
--
. through 1 7 47 42
1.8 47
13
1.3 83
15
2.1 84 19
2.1 22 16
1,2 1.2
1.0
.--
1.0 -- --
-- 0.7
-- --
1.4
--
0.7 0.4 0.5 <0.3
-- --
--
0.8
^ number of
free silica in the respirable fraction ranged from 1.3 to 13.7, with a mean of 7,2Gb, as determined from samples taken with the horizontal elutriator.
Correlation between 10-minute impinger tnd 150- to 180-minute respirable mass ^tuples for the entire 283 sample pairs was Poor. The ratios of impinger million parhcles per cubic foot to respirable milligrams P*r cubic meter varied about a geometric mean of 8.2; the dispersion is indicated by a 'tandard geometric deviation of 3. At least Part of this variation might be attributed to , e ^act that the impinger sampled only one-
teenth or so of the time that the mass sam P was operating. That this time factor did,
Ifi ^ (ncrease the dispersion is suggested by e fact that the 283 impinger samples have a
th n^ai^ Seornetric deviation {jff} of 2.7 about ^e'r geometric mean of 10 mppcf, whereas
e respirable mass samples vary about their nrriC mean ^4 mg/m5 with ir, of 2.2.
he samples were divided into five groups ollows: (l) sand mixing, (2) molding and Pouring, (3) hookout and shakeout, (4) cast . cleaning, and (5) core room. Correla
tion within groups was also poor, and leastsquares lines did not appear applicable.
Mean values for the samples by groups are shown in Table I. Samples collected in 1965 at four foundries and a number of foundry samples collected by another State Health Department were combined with the samples from the 1966-67 survey. Numbers of sample pairs for the 1965 sampling are not given, as unequal numbers of samples of the two types were taken.
To compare the evaluations of these foun
dries by the impinger method and by the respirable mass methods, a TLV of 10 mppcf
fa rounded value from the mean gross air borne free silica) and a limit of 1.1 mg/m1 (from the suggested formula given here and the mean respirable free silica) were used. Those operations averaging less than -/i of the limit were judged "silicosis hazard un likely," those between -/s of the limit and 1'/) times the limit were judged "silicosis hazard possible," and those operations ex ceeding H4 times the limit were judged "silicosis hazard likely." The comparisons on this basis are shown in Figure 2. Of 90
340 July-August, 196#
QCftOlP i CI \ *1
*1
2 * 3 t
4
&
*
67
a
9
t10i
12 >3
14
IB
19
zzo\ 21 15 16 I?
. -LIKELY
SILICOSIS} t0 -"PUONSLSIKIEBLLYE
QftQUP 5 Ct l*t
**
*
* |,*
!
1
OO oo
* [**
o *o
Cf *
*?HOO
Wt. * RfSPWASLE MASS METHOD.
Ficvre 2. Silicosis hazard evaluation by two methods.
Tabs.z H
Percentage of Free Silica in Gross Airborne Dut( and Dust Passing Four Size-Selective Devices
Cross. Air
30 3? 33 24 26 31 24 25
Hwsifonlal Afrotoc "2" Umco IB Elutriator at 35 dm at 18 1pm
6.0 8.3 11.2
8.6 8.3 4.1 3.6
8.6 14.2 22 3 15.5 14.5
8.4
13.8
3.8 5.7
M
Dt| P-ycton,
lers shortly after the beginning of the shift usually at 7:00 a.m. Another set of samples could then be run after the lunch break.
Discussion
operations, 42 were judged equally hazardous by count and weight, 32 more hazardous by weight, and 16 more hazardous by coum. Of the 90, however, only 9 were judged '"safe" by one method and "hazardous'* by the other.
Results of comparative sampling with the fnour size-selective devices are shown in Table
The difference between gross airborne and respirable free silica is similar to that found by Hatch and Moke11 and bv Holden ct al?* In our study a difference in the percentage of free silica was also found between sireselective samplers with different selection characteristics. On six sample pairs, the per
centage of free silica in a sample passing the Aerotec "2" at 35 cfm averaged 1.7 times the percentage in a sample passing the hori zontal elutriator. In three sample pairs, the percentage of free silica in samples passing the horizontal elutriator averaged 1.9 times that passing a Unico yi-inch cyclone at 18 lpm.
There were no problems with worker ac ceptance of die personal samplers, and. in general, the equipment performed satisfac torily. It was found desirable for the in dustrial hygienist to start the personal samp-
The results from a few comparative sam ples for free silica using different size-selective devices are insufficient to draw firm conclu sions, However, even with only six and three pairs, respectively, the differences between the horizontal elutriator and the Aerotec "2" and between the horizontal elutriator and the Unico 18 were significant at the 95^. level. The size-selection characteristics for the hori zontal elutriators are well defined in compari son to the other size selectors used, as the former can be derived theoretically and have been extensively tested. The size-selection characteristics of the other three samplers are not derived theoretically: they have been determined by projected microscopic rather than aerodynamic size. Of the four samplers, only the horizontal elutriator has been shown
to pass a weight fraction of dust comparable to that passed by the 2-lpm cyclone used for personal sampling.
To select the respirable fraction for free silica analysis, the horizontal elutriator, with its more precise cutoff characteristic, would appear to be the instrument of choice. For collecting samples for analysis of respirable free silica, it is therefore suggested that only horizontal elutriators designed according to the MRC criteria be used until it can be shown that other instruments yield equivalent results. The two commercial!], available hori
American Industrial Hygiene Association journal
341
zontal elutriators sample at rates of 50 Ipm and 2-5 Ipm, respectively. The former will not collect samples large enough for routine x-ray diffraction procedures, and the latter requires use of the colorimetric free silica pro cedure, Further development of simple Held techniques for taking "respirable" dust sam ples for free silica analysts is obviously re quired.
The ideal in assessing silicosis hazard is an analysis for free silica of each personal sam ple. With present techniques, this is obviously impractical. The alternative, to pool a group of personal samples from a particular opera tion. is probably also not practical for most laboratories. A third method, one that will probably have to be used for some time, is to collect free silica samples at a central location which, it is hoped, will apply to several per sonal samples. Fortunately, it appears that the composition is less variable in the respir able fraction than in the gross airborne dust.
borne of the differences between hazard ratings by the count method and by the re spirable mass method undoubtedly wore caused by the small portion of the mass sample pe riod included in the imptnger sampling time; >tne are probably caused by the fact that the bee silica percentages used were averages and did not necessarily represent the particular eperation: and some, we fed, represent a more realistic treatment of the dust hazard by 'he size-selected gravimetric sampling, ft is interesting to note that somewhat similar dif ferences were seen by Lynch and Aver1 when they compared impinger count and membrane filter fiber counts front simultan eous adjacent samples in the asbestos textile industry f5CKc of the samples were in the same concentration group: UKP differed by more than one group; group boundaries dif fered by a factor of 2).
Conclusions
1- Size-selective personal sampling would e easier and cheaper, with results more re producible for most industrial hygiene units.
- In metal foundries, where the greatest number of dust exposures occur, silicosis haz ard evaluations delimited bv the formula
Resp. mg/mJ = iO/f!GrfRFS + 2)
where '> RFS = percentage of tree silica in the respirable fraction will generally be con sistent with evaluations using the current ACGIH threshold limit,
3. The 10-tnm cyclone is a suitable size selector for personal sampling, but for free silica analysis samples a horizontal clutriator designed according to the MRC criteria may be required until other instruments are de monstrated to be equivalent.
Acknowledgments
The field sampling, dust counting, and free silica analyses were performed by numerous staff members of the Division of Occupational Health, Michigan Department of Public Health, and the Occupational Health Pro gram, U. S. Public Health Service, Their contribution and suggestions are deeply ap preciated.
References
i- Hatch. T. IF., and P. Gross: Pulmonary Deposition
nnd Retention.
inhaled Aerosols, Academic Prewt*
Now Ymk ihjtvjr.
2. Morrow, P. .; Evaluation of Inhalation Hazards
8a><*d upon the Respirable Oust Concept and the
Htitamphy and Application of Selective Sampling, Amtr, hid. fixg. Anoc. j. 2J; 2if4 Mav-fune i%4t.
3. Orn*tkin, A- JL i Ed. \: Proceedings of the Pncuma* cofSiWs Conference, Johannesburg, /9o!9, J. Sc A. Church* til, Ltd.. Loudon j'i4.*60K
4. Repotted by Lippmvns, \t , and W. B, Harris, irt reference li.
5. fkeKNUNs. j. %{.: Correction Factor for Sise-Selective
pint* Remit* Based
a \>w Computed Alveolar
Curve. ,1**. (ht up, HVg, ft: 221 I July
fi. T.ipRM'tNv. M., ami W. 8. Harris; Suc-Seieeme Sam
pler* for KxtmuiHK "respirable1' Dust Concentrations. fftidih Phi-s, 8: 135 . t%2),
7, -Shttoy, (i. W.: Calibration of Aerodvnamic Size v.
Krtfedeucv for a Miniature Cyclone. Presented at the \*M attmiai meetbur, American Industrial Hygiene Asux-i.ition. PMtshurRh. Pennsylvania.
S. Rf.vq. S. j., H. B. Ashk. and B, T, H, (.f.vuiip.: A C^mpari-woi uf Count and Respirable Mass D>t Sam
pling Technique* in the Granite Industry. Presented at {he annual Uiertifur. American Industrial Ifv^ienc A*s*keiari<m, Pirtsi}rtfh, Pennsylvania.
1L Ri'ssril, A. .: Silicosis anti Other Dust Diseases, The Ifaroki S. Boqimt Second Annual Memorial Lecture
Iifivi'n at die ( nivrrutv of Minnesota, December 3,
10. SirrTO.v, C. W.. and S. J. Reno: Sampling in finrre, Vermont, {haiiite Sheds, TR-41), Occupational Health Pro-am. \CUH . April P367K
U. Hatch, f.< and C. 8. Moke: The MineraJogical Coratiovtkm of Airborne Foundry Dust. /. Ind. Hve. Toxwol IS: 91 (19361,
12. iTmncx, F, R.. W C. L. Herson. and F. C. Hv*tt: Appraisin* exposures to \ilic3 dust, /. Ind, H\g. To\ruoL -HJ: 265
13. ffs.RJt!i. W. R.. and \f. EtsNsrn: Oust Sampler Which Simulates Upper and Lower Lun* Detrition. ,LIM Arch. ind. Hvg. Oc<up. Med, 8? 446 <19531.
J4. Hvnii'Wi, R. f-. ami W. ff. WutnN: The Selective
Sampling nt Rcsnirahle Dust. In Inhaled Particles and
C,
vm).
Davies, ed. 5. Pertainon Press, London
'
15. Conintsitee on Standard Methods: Standard Imping*?