Document 0qbr1yvdxvKr2G4e1xjeMrMRm

t r r intern. J. Environmental Studies, J9?0, Vol. 1, pp. }}>)4 (g> Gordon and Breach Science Publishers Lid. Primed in Exeter, England. THE DEPOSITION OF ASBESTOS PARTICLES IN THE HUMAN RESPIRATORY TRACT J. M. BEECKMANS 1 Faculty of Engineering Science, University of Western Ontario, London 72, Ontario, Canada IKerritvd May A, 1970) Tlic di'|\>siiu>n of asix'sios particles in Hie human respiratory tract was studied theoretically hy treating them as ellipsoids of revolution, in a modified version of the method previously used hy the author to study the deposition of spherical particles. The results show that as the eccentricity of the ellipsoids is increased at constant equatorial diameter, deposition is reduced in the diffusion-controlled particle-size region below about 0.2 y. In the particle- size region where sedimentation and impaction are the controlling mechanisms, an increase in the eccentricity of the ellipsoidal particle at constant equatorial diameter is equivalent to an appropriate increase in panicle density, and the deposition curves are displaced io the left. INTRODUCTION CHARACTERISTICS OF ASBESTOS DUST Microscopic asbestos fibres in the atmosphere Since the bulk of the world's production of asbestos represent a very real potential hazard to individuals is of the variety known as chrysolite, this form will occupationally exposed to such conditions. The be taken as the model in what follows. Chrysotilc assessment of the relative toxicity of a particular occurs in the form of needles with diameters be atmosphere containing asbestos includes a deter tween 150 A and 1000 A (0.015-0.1 y) having a mination of the chemical and physical properties of density of approximately 2.6 g/cc. However, when the dust, including its particle-size and particle- dispersed in the atmosphere chrysotilc fibres are shape distribution, and an estimate of what pro frequently agglomerated into fibre bundles up to portion of this dust may be expected to be deposited 0.5 y in diameter, and with lengths up to 60 times in the lower respiratory tract, where the dust is the diameter (Walter*). Other forms of asbestos potentially dangerous. This paper is concerned with occur as fibres having diameters up to 0.5 y. the latter aspect of the problem, which does not appear to have received adequate attention to date. The deposition of spherical particles in the respiratory tract is fairly well understood, and it has been the subject of many experimental and theo retical investigations. Since it is virtually impossible to measure the deposition of dust of controlled properties in the lower respiratory tract in humans, the deposition of spherical particles in this region DEPOSITION EQUATIONS The deposition of fibrous panicles was calculated by assuming that they behave approximately as prolate ellipsoids of revolution. A prolate ellipsoid of revolution is obtained by rotating an ellipse about its major axis. The mobility of such a panicle is given by Fuchs1 as follows: has been studied theoretically by a number of B *= C[2nya(2xi 4 Xa). () investigators (Findeisen,1 Landahl,*'* and Becckmans4, *). These same studies alto yielded curves for total deposition, as functions of particle size, particle density, and breathing pattern, which were in relatively good agreement with experimental data. This agreement naturally strengthens the validity of the calculated alveolar deposition where B is the mobility, defined as the ratio of the terminal velocity of a panicle to the applied force, C is a slip correction factor, a is the semi-minor axis of the ellipsoid, > is the fluid viscosity, and *, and xt art shape factors given by Xl -2.667(0' -1)/ curves. No such studies have been made in the case of elongated particles such as fibres, and it is the {^?l'ntf + '/5ir75+'i} objective of this paper to provide an assessment of the deposition behaviour of such particles in the respiratory tract, with particular reference to . n-UJJtf'-l/ -`H. asbestos dust . * it SCF-FA-6307 8000 1526 ' PRODUCED BY FORD M. beeckmans ji K ilu* eccentricity. defined us llie ratio or the major axis to the minor axis. The mobility equation:, for the ellipsoid was then iiwd to modify the deposition equations for spheres previously used by Beeckmans4 to calculate aerosol deposition in the respiratory tract, and the calcula tions were performed hy computer as described in that publication. For deposition by dilfusion, the equation for spheres may be written (Beeckmans4) as O', - I -\p (-- 7.31 Dt/2R\). (3) where O', is the probability that a particle is de posited during inspiration in region a, O is the particle diffusion coefficient, f, equals the time of passage through region o, and R, is the radius of region u. Equation (3) was used to calculate the deposition probability of an ellipsoidal panicle in region o of the respiratory tract by using the expression D = kTB for D, where k is the Boluniann eonstant. T is the absolute temperature, and }> is ihe.mobility as calculated by means of Eq. (1 j. (Each region of the respiratory tract .was approxi mated by a set of parallel cylinders, as outlined by Beeckmans4) For deposition by sedimentation, the correspond ing expression previously used by Beeckmans4 for spheres may be staled as Si I -- cxp( ~2l`T,/nR.). (4) where S', is the probability that a particle will be deposited by sedimentation in region a during inspiration, and p is the sedimentation velocity of the particle. The sedimentation velocity of an ellipsoid may be obtained from its mobility as follows. The mass of the ellipsoidal particle equals p/3, where p equals the density of the particle. This mass times the gravitational constant g equals the gravitational force on the particle. Hcncc, from the definition of /I, 0 the angle between the axes of airways (a -- 1) and a. The stopping distance of a sphere or of an ellipsoid is given by L = VMS!3. . C?) where Kis the initial velocity of the particle, and M equals its muss. Eqs. (I). (2), (6), and (7), together with the expression for the mass of the ellipsoid, are sufficient to allow calculation of /.'. The angle 9 was assumed to be equal to 30 in all calcula tions. - The slip correction factor C was calculated by means of an equation for spheres derived by Davies." Jt was applied to ellipsoidal particles, with the equatorial diameter of the ellipsoid substituted for the diameter of the sphere in Davies' equation, in default of a correct expression for slip in ellip soidal particles in the literature. This procedure seemed preferable to the alternative of not correct ing for slip, but it probably resulted in a slight overestimate of the mobility of particles in the lower size ranges. RESULTS The program was executed for a 1000 cm* tidal volume, and a 3-sce breathing cycle, with 0.3 see pauses at the end of inspiration and at the end of expiration. The functional residual capacity of-the p *= 4n/Ja*p/3 (5) Equations (If (3). (4), and'(5) together allow the calculation of SJ. The expression previously used by Beeckmans4 to calculate deposition by inertial impaction at the branching of the airways may be wriitten as n a/*.>/{ + iW). (6) where L equals the stopping distance of the particle travelling with an initial velocity p,_, tin 9, p,_t being the velocity of the particle in region (a -- I), FIGURE I Fraction of inhaled particles deposited in all regions of the respiratory tract, vs equatorial diameter of the panicle, for various values of f. &000 1527 ppnnnrpn dv ASULSTOS IN Till; HUMAN RESPIRATORY TRACT 33 MINOR DIAMETER (MICRONS) FIGURE 2 Fraction of inhaled panicles deposited in the lower (alveolated) region of the respiratory tract, vs equa torial diameter of the panicle, for various values of p. lung was taken as 2000 cm*. The total and alveolar deposition curves for p values of 1, 4, 16, and 64 are shown in Figures 1 and 2. The abscissa repre sents the equatorial diameter of the ellipsoidal particles, in microns. These results art perhaps most easily understood by considering the effect of increasing p on the panicle mobility. It is easily shown, using equations (1) and. (2), that 3Cln(fl Lim B 20np`P (8) Thus as p is increased indefinitely, B tends to 2ero. This accounts for the reduoed deposition of the elongated ellipsoids in the particle size range 0.02 (i to approximately 0.2 p, because diffusion is the predominant mechanism for deposition in this region, and the diffusion coefficient of a particle is proportional to its mobility. Thus the exponential factor in Eq. (3) will tend to zero as p increases indefinitely. :iml consequently /),' will nlsii tciul to zero. In the panicle-size region above 0.2 /> scdiiucutnlion and impaction are more importam mechanisms than diffusion. The exponential factor in the sedi mentation equation (Eq. 4) is proportional to the sedimentation velocity of the panicle, which in turn is proportional to piJ. This product becomes proportional to In P as P increases indefinitely. Consequently increasing P increases the sedimenta tion velocity, and increases the rale of deposition due to sedimentation. A similar argument for im paction shows that the slopping distance becomes proportional to In p as p increases indefinitely, and consequently the factor approaches unity. Now the equations for impaction and sedimentation both contain the factor ppB\ consequently an in crease in p at fixed p can be simulated as far as these two mechanisms are concerned by an appro priate increase in p at fixed p. In other words, the deposition behaviour of ellipsoids of a given density and of a given equatorial diameter is equal to that of spheres of equal diamater, but having a greater density such that (p?B) is equal for both classes of particles. This is true only in the particle size region where diffusion is insignificant. Landahl*-* and Beeckmans4, * had shown that as the density of spherical panicles is increased, the total and alveolar deposition curves are shifted towards the left, and the same can be seen in the results pre sented here as p is increased. Finally, it is peninent to ask if interception might not play a role in deposition for very elongated particles. Interception might be expected to be of significance when the polar diameter of the particle approaches the dimensions of the smaller airways. The respiratory tract model used in this study is due to Weibel,* who calculated a value of 0.041 cm for the diameter of the alveolar sacs, at a functional residual capacity of 4.8 liters. In the present study, the functional residuat capacity was 2 liters, and the tidal volume was 1 liter. Consequently the mean lung volume during the breathing cycle was 2.5 liters, and the corresponding alveolar diameter was 0.041 x (2 5/4.6) cm, or 349 /*. The longest par ticle for which calculations are reported here had a P value of 64 and an equatorial diameter of 3ji. Consequently its length was 192 p. Moreover, as can be seen from the figures, this type of particle is virtually completely deposited in the upper respiratory tract, and consequently inter ception in the lower respiratory tract, if it were to occur, would not be of significance. U I/I-- { I I lI t I i I > 8000 1528 PRODUCED BY FORD 34 J. M. BEECKMANS KCPCKENCES ). AV. Findciwn, Arch. Get. Phvtiol. 036. 367 (I93J). 0. H. D. UnJahl, Bui!. Math. Biophvs. JO. 43 (1930). 3. H. D. Landahl. BuIS Math. Biophys. 25.29 (1963). 4. J. Nl. Dccckmans, Can. J. Physiol. Pharmac. 43,137 (J965). 5. J. M. Bccckmans, Ann. Occup. Hygiene 2,221 (1965). 6. E. Walter. Slouh 27. 16 (1967). 7. N. A. Fuchs. The Mechanics of Aerosols (Per^amon New York. 1964). p. 37. ' 8. C. N. Davies, Proe. Phys. Soe. London 57,259 (1945). 9. E. R. Weibcl, The Morphometry of the Human Lung (Academic Press, New York, 1963). BDOO f 529 i ' PRODUCED BY FORD