Document 0qbO0Qzz34N1JJo6Mx1Vkzpgb

HEATINC VENTILATING AIR CONDITIONING CUIDE 1944 room application. The criterion of a well controlled installation is one which has neither too few nor too many controls'. (See Chapter 34). With the expansion of cities during the past decade", the problem of water supply has become a costly and ever present problem6. Con sequently, laws are appearing designed to restrict the usage of water wherever possible, particularly when substitute means are available. Evaporative condensers and cooling towers (described in Chapters 25 and ' 27) are means devised to save large quantities of water in this connection. Most manufacturers furnish equipment designed for use in combination . with these water savers. Municipal plumbing, heating, electrical and refrigeration codes, as well as fire underwriter restrictions, are likewise having their effects on the application of unit air conditioners. Meeting municipal and national code requirements should be an important item in connection with the installation of any unit equipment. Ratings There are two codes governing the rating and testing of unit air con ditioners. The first code, Standard Method of Rating and Testing Air Conditioning Equipment6, covers all types of air conditioning units except the self-contained type. The latter is covered by .the second code, The Standard Method of Rating and Testing Self-Contained Air Conditioning Units for Comfort Cooling7. The two codes are necessary because of the basic difference caused by the heat given up by the self-contained units. The standard rating conditions for self-contained unit air conditioners, as given in the code, are set forth in Table 1. The standard rating of a self-contained unit for the conditions specified in Table 1 include all items which apply to the function of a unit as: (1) name of unit, (2) functions which unit performs, (3) data on cooling, (4) data on heating, (5) data on air flow, and (6) data on humidification. The standard rating conditions for unit air conditioners, other than the self-contained type, are identical to those in Table 1 except the entering wet-bulb temperature, for cooling is expressed as 5fl per .cent relative humidity (66.7 F wet-bulb) instead of 67 F wet-bulb temperature. In addition, the saturated suction refrigerant temperature for comfort cooling is specified at 40 F. This condition is omitted from Table 1 for. self-contained units as immaterial in the rating of a unit that includes the evaporator and condensing unit. UNIT AIR COOLERS This type of unit is primarily intended to perform the main function of cooling air, with humidity control a secondary function within the limita tions of the design. The main application of this equipment is in process' and product refrigeration such as cold storage warehousing, fruit and `Concerning Conservation of Underground Water with Suggestions for Control, by Noel E. Porter (A.S.H.V.E. Transactions. Vol. 47. 1941. p. 309). Loc. Cit. Note L . T-oc. Cit. Note 2. ' 438 CHAPTER 23. UNIT AIR CONDITIONERS, UNIT AIR COOLERS, ATTIC FANS Table 1. Standard Rating Basis for Self-Contained Air Conditioning Units Functions Types op Units Item Rating Condition Description Value All Cooling All a Water-Cooled, Air-Cooled and Evapora- tively Cooled Condensers b c Water-Cooled d Condensers e Barometric Pressure 29.92 in. Hg. Unit Ambient and Air Entering Room---Air Inlet (1) Dry-Bulb (2) Wet-Bulb 80 F 67 F Ventilation Air See Note Water Temperature Entering Unit 75 F Water Temperature Leaving Unit 95 F Air-Cooled f Air Entering Outside Air Inlet and Evapora- (1) Dry-Bulb tively Cooled (2) Wet-Bulb Condensers 95 F 75 F Heating s Unit Ambient and Total Air Enter ing Unit 70 F All Types Provided h Heating Medium, Pressure or with Heating Function Temperature (1) Dry Saturated Steam 16.7 lb per sq in. abs. (2) Water In ,(3) Water Out 180 F 160 F . All Types i Unit Ambient Provided with Humidifying Humidifying j Total Air Entering Unit. Function (1) Dry-Bulb (2) Wet-Bulb 70 F 70 F 53 F Air Circulation All . k Filters , New and Clean- Note: Rating be based on both ventilation and recirculated room air entering'at 80 F diy-bulb and 67 F wet-bulb temperature. (The Note as given in the code has been condensed in order to remove material not pertinent to this chapter). vegetable packing, in breweries, and in wholesale and retail food markets;1 although some comfort cooling may be obtained by the use of a unit similar in design to this type of unit as previously explained and as illustrated by Fig- 6. Application of the unit method of air cooling with mechanical circu lation is comparatively recent, being an improvement over the pipe or finned coil, which depended on gravity for circulation. Bunkers were sometimes constructed around the coils to. direct the air flow and some times fans were used for forcing air over the coils. The location of the unit air cooler is usually within the refrigerated area, but the larger,, blower/type models may be remotely located. 439