Document 0qRyjaV3Dnx5y1bd50d3Xd0QR
RECEIVED
Interoffice Communication
OCT 24 1975
To From
Distribution Douglas Michels
- j/beActe***-
Date October 22, 1975
Subject VCM Emissions From Sweco Under Non-Stripping Conditions
Last night two large reactor batches, one a 5505 and the other a 5425, were dropped without steam stripping. The recovery procedure used a 20 minute hold period at a 20 inch vacuum condition to remove as much VCM as possible prior to dump. The non-stripped batches were produced at the request of Ponca City to supply material for testing the Goodrich stripping process.
During the dumps of these batches I monitored the Honeywell readings at the Sweco to identify the concentrations of VCM which exist when dumping a nonstripped batch. As a comparison September data under stripping conditions showed 4.1% readings in excess, of 1 ppm and 0.5% above 5 ppm.
The concentrations during dump of the 5505 batch ranged from 5-25 ppm with the average of 6 readings being 10 ppm. Concentrations above 1 ppm persisted until about 10 minutes into chem 'wash.
Hie concentrations during dump of the 5425 batch ranged from 4-13 ppm with the average of 5 readings being Sppm. Again concentrations above 1 ppm persisted until about 10 minutes into chem wash.
This data points out the value of in-reactor stripping in reducing potential exposures in the Sweco, chem wash and reactor areas. If Conoco adopts an external stripping process such as Goodrich tnese OSTIA problems as we 11 as the related ePA problems will need attention. Possibly both in reactor and external stripping will be necessary.
Douglas Michels Chief Process Engineer
c: PAD, GWP, RKS, JVU, ELK, JWH, DHS,
WFR
SAL 000107709