Document 0qQqNQb6gg3kJejKLObZY6G4R
Internal Correspondence de: M. T. Case - 218-3
E. G. Lamprecht - 218-3 W. C. McCormick - 220-2E-02
V. Pothapragada - 236-3A R. A. Prokop - 236-2B L. D. W in ter - 236-2B
AR 7X-OIS5
To: From. Subject: Date:
E. G. GORTNER - RIKER - 218-3-3 T. R. MATHIS EN - COMMERCIAL CHEMICALS - 236-2B ANALYTICAL ANALYSES OF SUSPENSION OF FM-3924 A p r il 8, 1981
INTRODUCTION *
Reference: CCD A n a ly t ic a l Method #G-29-0381
Four samples o f corn o i l w ith suspended FM-3924 were re c e iv e d on March 16, 1981 from E. G. G o rtn e r. The fo u r samples la b e le d P la c e b o corn o i l , T-2999 COC 25 mg/kg/day FM-3924, T-2999 COC 2.5 mg/kg/day and T-2999 COC 0.25 mg/kg/day were subm itted f o r mg/ml c o n c e n tra tio n o f FM-3424, f o r use in a r a t fe e d in g stu d y . The samples were run by a GLC method usin g a methanol e x t r a c t io n and an in t e r n a l stan d ard .
GLC RESULTS:
Sample
Placebo Corn O il
T-2999 COC FM-3924 0.25 mg/kg/day
T-2999 COC FM-3924 2.5 mg/kg/day
T-2999 COC FM-3924 25 mg/kg/day
Mg/Ml FM-3924 No FM-3924 d e te cte d 0.0459 mg/ml FM-3924
0.4694 mg/ml FM-3924
5.136 mg/ml FM-3924
SUMMARY:
A l l samples were w it h in 102 o f t a r g e t and showed good r e p r o d u c i b i l i t y . The s o l u b i l i t y o f FM-3924 was found to be low . Standards used show s ig n s o f s a t u r a t io n a t 0 .5 mg/ml le v e l. I t was found th a t s o n if i c a t io n would d is s o lv e the FM-3924 in t o the corn o i l . But a f t e r s e v e ra l days th e 5 mg/ml stan d ard showed some c r y s t a l iz a t io n , bu t a f t e r s o n if i c a t io n i t would r e - s o lu b iliz e . The c r y s t a liz a t io n co u ld cause problems in the feeding study corn o i l .
TRM/hc
004330